At least 703 records · Page 39

Addressing energy storage needs at lower cost via on-site thermal energy storage in buildings

Cost-effective energy storage is a critical enabler for the large-scale deployment of renewable electricity. Significant resources have been directed toward developing cost-effective energy storage, with research and development efforts dominated by work on lithium ion (Li-ion) battery technology. Though Li-ion batteries have many attractive qualities, it is not clear whether they can provide an affordable levelized cost of storage (LCOS) for certain applications, such as buildings. Buildings consume most of the world's electricity, and as much as 50% of their consumption goes toward meeting thermal loads. Thermal energy storage (TES) can provide a cost-effective alternative to Li-ion batteries for buildings; however, two questions remain to be answered. First, how much of total building energy storage requirements can be met via thermal storage for building loads? Second, can the LCOS for TES be favorable compared with Li-ion batteries? In this perspective, using the United States as a case study, we show that the total requirement for TES in buildings is in the range of ~1200–4500 electrical GW h, depending on the fraction of solar versus wind in the generation mix. Furthermore, we show that with at least 25% wind generation, all of the storage needed by buildings to support the grid can be met by TES. We also introduce a framework to calculate LCOS for on-site TES in buildings to enable a direct comparison with electrical storage technologies such as Li-ion batteries. This is not trivial, because the input energy type for TES (electricity) differs from the output energy type (thermal energy), and the efficiency can depend on ambient conditions. Our LCOS analysis shows that in many situations, TES can be more cost-effective for buildings than Li-ion batteries. We conclude our perspective by discussing future research and development opportunities that can significantly advance the deployment of TES for buildings to help enable a renewable electricity-dependent grid.

25 ENERGY STORAGE↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

Characterization of wind conditions and impact on wind loading at an operational parabolic trough concentrating solar power plant using LiDAR observations

Wind loading is a major factor influencing the structural design costs of Concentrating Solar Power (CSP) collector systems, including heliostats and parabolic troughs. Traditionally, these designs have been based on wind-tunnel data, which often fail to accurately represent the dynamic effects experienced at full scale. This study presents a first-of-its-kind experimental characterization of wind conditions within an operational parabolic-trough CSP power plant focusing specifically on using lidar observations. The lidar observations give a unique opportunity to provide insights into wind flow conditions deep within the trough arrays. Our results suggest that (1) after being blocked by the first few rows, the wind speed above the troughs recovers to 73% of its inflow magnitude as it flows further over the trough field due to enhanced turbulent mixing and (2) due to the wind speed recovery, troughs in the interior field will likely experience higher shear-induced turning moments compared those at the front. The conclusions from this work stress the importance of better understanding the wind patterns and interior wind loads when designing solar collectors and highlights the need for more interior load measurements in the future field campaigns.

17 WIND ENERGY↗

An analysis of physics limited dispatch of nuclear renewable integrated energy systems using deep reinforcement learning and dynamic modeling

Previous approaches to dispatching nuclear integrated energy systems (NIES) have focused on the profitability and flexibility of these systems to operate on energy grids with highly variable pricing. However, due to the complexity involved in modeling and designing these systems, there has been less emphasis on ensuring that these dispatch strategies are physically achievable. It is imperative to develop methods that allow the system to remain within the desired NIES operating conditions and perform this based on realistic limited forecasted information. This research employs next generation artificial intelligence, namely deep reinforcement learning (DRL), and a dynamic system model written in Modelica to find a safe and profitable dispatch strategy for a solar nuclear hybrid design. The DRL agent is shown to find a novel dispatch strategy that manages both power ramping and power levels while respecting operational limits. This DRL-based dispatch is compared to other dispatching strategies including an optimal design solution from mixed integer linear programming (MILP). It is found that incorporating the physics of such a tightly coupled NIES limits the profitability of the MILP-based dispatch strategy. As a result, the MILP solution overestimates the design’s generated revenue. In contrast, DRL significantly reduces the number of breaches of safe operational conditions during energy arbitrage while maintaining profitability. Furthermore, this work paves the way for a more detailed assessment of NIES profitability and could be used to aid operator decisions on future NIES projects.

14 - SOLAR ENERGY↗

Exchange-correlation functional challenges in modeling quaternary chalcogenides

The development of next-generation quaternary chalcogenides, such as Cu2ZnSnS4 (CZTS) and Cu2ZnGeS4 (CZGS), for solar energy and thermoelectric applications hinges upon both careful experimentation and accurate quantum mechanical modeling. To address the latter, many have turned to density functional theory (DFT), which offers several choices for the approximate treatment of electron exchange and correlation (XC). Popular XC functionals include the Perdew-Burke-Ernzerhof (PBE) generalized gradient approximation (GGA) and the recently developed strongly constrained and appropriately normed (SCAN) meta-GGA. Extensions of DFT functionals, such as adding a Hubbard U correction and introducing a fraction of the Fock exchange (hybrid functionals), have been used widely to model systems containing 3d metal ions. However, no studies yet have compared comprehensively PBE(+U) and SCAN(+U) in the quality of their predictions of the bulk and defect thermodynamics of quaternary chalcogenides, which play a critical role in device fabrication and performance. Hence, here we calculate the (i) 0 K formation energies of bulk Ge compounds and (ii) neutral defect formation energies including charge-balanced (e.g., CuZn + ZnCu) and charge-imbalanced (e.g., CuSn) combinations of antisites and vacancies in CZTS and CZGS using the PBE, PBE +U, SCAN, SCAN +U, and the hybrid Heyd-Scuseria-Ernzerhof XC frameworks. We find that the formation energies of charge-imbalanced defects are more sensitive to the choice of the XC functional than those of charge-balanced defects, which can be explained by the differences in the extent of penalization of defect-generated delocalized electrons/holes by PBE, PBE +U, SCAN, and SCAN +U. Additionally, our results show that SCAN systematically underbinds Ge-containing compounds, thus highlighting the need for even further improvement of XC functionals. Based on our findings, we recommend the use of SCAN for modeling quaternary chalcogenides because its errors are systematic, and it has the firmest theoretical underpinning. Our work provides guidance for future modeling of quaternary chalcogenides.

14 SOLAR ENERGY↗

Low-Cloud Feedbacks from Cloud-Controlling Factors: A Review

Abstract The response to warming of tropical low-level clouds including both marine stratocumulus and trade cumulus is a major source of uncertainty in projections of future climate. Climate model simulations of the response vary widely, reflecting the difficulty the models have in simulating these clouds. These inadequacies have led to alternative approaches to predict low-cloud feedbacks. Here, we review an observational approach that relies on the assumption that observed relationships between low clouds and the “cloud-controlling factors” of the large-scale environment are invariant across time-scales. With this assumption, and given predictions of how the cloud-controlling factors change with climate warming, one can predict low-cloud feedbacks without using any model simulation of low clouds. We discuss both fundamental and implementation issues with this approach and suggest steps that could reduce uncertainty in the predicted low-cloud feedback. Recent studies using this approach predict that the tropical low-cloud feedback is positive mainly due to the observation that reflection of solar radiation by low clouds decreases as temperature increases, holding all other cloud-controlling factors fixed. The positive feedback from temperature is partially offset by a negative feedback from the tendency for the inversion strength to increase in a warming world, with other cloud-controlling factors playing a smaller role. A consensus estimate from these studies for the contribution of tropical low clouds to the global mean cloud feedback is 0.25 ± 0.18 W m −2 K −1 (90% confidence interval), suggesting it is very unlikely that tropical low clouds reduce total global cloud feedback. Because the prediction of positive tropical low-cloud feedback with this approach is consistent with independent evidence from low-cloud feedback studies using high-resolution cloud models, progress is being made in reducing this key climate uncertainty.

58 GEOSCIENCES↗

Status Quo and Gap Analysis of Heliostat Field Deployment Processes for Concentrating Solar Tower Plants

In this study, deployment of the solar field of a concentrating solar power plant is one of many factors that are integral to the success of a project. Knowledge transfer from outside the industry is limited due to the unique nature of heliostats, which redirect sunlight to a receiver with high precision while maintaining a high level of reflectivity. Moreover, learning from project to project can be limited due to the site-specific nature of projects, as the market includes several developers, each with their own unique design. In this paper, we discuss the state of the art in heliostat field deployment. We cover all the key aspects of deployment from project assessment to a fully functioning system, which include site selection, layout development, supply chain, assembly, site preparation and construction, calibration, and operations and maintenance. We then perform a gap analysis on field deployment and recommend priorities for future research.

14 SOLAR ENERGY↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

Electrolyte Immersion Increases Photoconductivity in a Model Polymer Photocathode

Immersing polymer solar cells in aqueous electrolyte for photoelectrochemical (PEC) hydrogen production is likely to cause photophysical changes that could present both challenges and opportunities for engineering functional and durable devices. Herein we study the bulk heterojunction blend poly(4,8-bis(5-(2-ethylhexyl)thiophen-2-yl)benzo[1,2-b:4,5-b']dithiophene-2,6-diyl)-alt-(2-(((2-ethylhexyl)oxy)carbonyl)-3-fluorothieno[3,4-b]thiophene-4,6-diyl):poly(N,N'-di(2-octyldodecyl)naphthalene-1,8:4,5-bis(dicarboximide)-2,6-diyl)-alt-(2,2-bithiophene-5,5'-diyl) (PTB7-Th:N2200) excited-state dynamics in electrolyte from femtosecond to millisecond time scales using pump-probe microwave conductivity and absorption spectroscopy. While the blend swells very little, electrolyte exposure increases the microwave-frequency mobility and possibly the yield of photogenerated charges while also decreasing crystallinity. These results indicate an enhancement in key performance metrics, implying that any limitations on the performance of PEC test devices do not arise from active layer-electrolyte interactions. For the PTB7-Th:N2200 blend or similar photocathode systems, our results indicate that improving the interfacial kinetics and/or the carrier lifetime should be prioritized, not protecting the active layer from the electrolyte. Since this observation may not be universal to all polymer systems, future research should focus on identifying their limiting photophysical processes. electrolyte.

14 SOLAR ENERGY↗

Membranes in Solar-Driven Evaporation: Design Principles and Applications

In this study, solar-driven evaporation process brings exciting opportunities to recover clean water and resources in a sustainable way from diverse sources like seawater and wastewater. Separation membranes, as a vital material in many environmental and energy applications, can contribute significantly to this process owing to their structural features. However, the unique roles of membranes in solar evaporator construction and process design are seldom recognized and not summarized yet from scientific principles and application demands, which forms the motivation of this review. Herein, the roles of membranes in different processes based on solar-driven evaporation are focused and the design principles of membrane materials and devices to meet the requirements of these applications are discussed. Fabrication strategies for photothermal membranes are introduced primarily, followed by a discussion on how to design membrane materials, devices, and processes to pursue optimal performance and realize advanced functions accompanied by evaporation. Furthermore, the future of this field is forecast with both challenges and opportunities.

14 SOLAR ENERGY↗

Investigations of water/oxide interfaces by molecular dynamics simulations

Water/oxide interfaces are ubiquitous on earth and show significant influence on many chemical processes. For example, understanding water and solute adsorption as well as catalytic water splitting can help build better fuel cells and solar cells to overcome our looming energy crisis; the interaction between biomolecules and water/oxide interfaces is one hypothesis to explain the origin of life. However, knowledge in this area is still limited due to the difficulty of studying water/solid interfaces. As a result, research using increasingly sophisticated experimental techniques and computational simulations has been carried out in recent years. Although it is difficult for experimental techniques to provide detailed microscopic structural information, molecular dynamics (MD) simulations have satisfactory performance. In this report, we discuss classical and ab initio MD simulations of water/oxide interfaces. Generally, we are interested in the following questions: How do solid surfaces perturb interfacial water structure? How do interfacial water molecules and adsorbed solutes affect solid surfaces and how do interfacial environments affect solvent and solute behavior? Finally, we discuss progress in the application of neural network potential based MD simulations, which offer a promising future because this approach has already enabled ab initio level accuracy for very large systems and long trajectories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

States of Cybersecurity: Electricity Distribution System Discussions

State and local entities that oversee the reliable, affordable provision of electricity are faced with growing and evolving threats from cybersecurity risks to our nation's electricity distribution system. All-hazards system resilience is a shared responsibility among electric utilities and their regulators or policy-setting boards of directors. Cybersecurity presents new challenges and should be a focus for states, local governments, and Native American tribes that are developing energy-assurance plans to protect critical infrastructure. This research sought to investigate the implementation of governance and policy at the distribution utility level that facilitates cybersecurity preparedness to inform the U.S. Department of Energy (DOE), Office of Energy Policy and Systems Analysis; states; local governments; and other stakeholders on the challenges, gaps, and opportunities that may exist for future analysis. The need is urgent to identify the challenges and inconsistencies in how cybersecurity practices are being applied across the United States to inform the development of best practices, mitigations, and future research and development investments in securing the electricity infrastructure. By examining the current practices and applications of cybersecurity preparedness, this report seeks to identify the challenges and persistent gaps between policy and execution and reflect the underlying motivations of distinct utility structures as they play out at the local level. This study aims to create an initial baseline of cybersecurity preparedness within the distribution electricity sector. The focus of this study is on distribution utilities not bound by the cybersecurity guidelines of the North American Electric Reliability Corporation (NERC) to examine the range of mechanisms taken by state regulators, city councils that own municipal utilities, and boards of directors of rural cooperatives.

14 SOLAR ENERGY↗

Task 2 Report - A GIS-Based Technical Potential Assessment of Domestic Energy Resources for Electricity Generation

The purpose of this report is to support the Lao Ministry of Energy and Mines (MEM) in assessing the technical potential of domestic energy resources for utility scale electricity generation in the Lao PDR. Specifically, this work provides assessments of technical potential, and associated maps of developable areas, for energy technologies of interest. This report details the methodology, assumptions, and datasets employed in this analysis to provide a transparent, replicable process for future analyses. The methodology and results presented are intended to be a fundamental input to subsequent decision making and energy planning-related analyses. This report is the second output of the Energy Alternatives Study for the Lao PDR (Energy Alternatives Study), a collaboration led by MEM and the United States Agency for International Development under the auspices of the Smart Infrastructure for the Mekong program.1 The Energy Alternatives Study is composed of five successive tasks that collectively support the project’s goals as shown in FIGURE ES-1. This work is focused on Task 2 – Assess technical potential of domestic energy resources for electricity generation . The work was carried out by a team from the U.S. Department of Energy’s National Renewable Energy Laboratory (NREL) in collaboration with MEM and other Lao power sector stakeholders. This work concentrates on domestic energy resources for utility-scale electricity generation and considers solar photovoltaic (PV), wind, biomass, and coal resources. This work does not consider potentially imported energy resources (e.g., natural gas) or domestic energy resources that are not present in sufficient quantity for utility-scale generation (e.g., geothermal resources). A technical potential assessment of hydropower resources is currently not feasible due to the absence of required data including site-level assessments of multiple characteristics (e.g., geology environment and access) as well as spatial data on estimated non-exploited hydropower resources (Lee et al. 2018). Previous studies estimated total hydropower resource potential to be between 23,000 and 26,000 MW, of which approximately 3,894 MW has been developed (IES and MKE 2016; MEM 2015b, 2011). MEM and Électricité du Laos have gained significant experience in the evaluation and development of hydropower resources and expect to develop close to 10,034 MW of additional capacity by 2025 (MEM 2017).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Closed-loop pressure retarded osmosis draw solutions and their regeneration processes: A review

Pressure-Retarded Osmosis (PRO) is an osmotic process that has been used to harvest energy from salinity gradients using a semi permeable membrane. A comparison between open-loop PRO (OLPRO) and closed-loop PRO (CLPRO) was made regarding their performance and costs. In CLPRO, where the diluted draw solution is re-concentrated in the regeneration system to be reutilized in the process, has recently received an intensive focus as the most viable configuration for a standalone power plant. The choice of the PRO draw solution in CLPRO is crucial to garner a high osmotic pressure as the key for the feasibility of the process. Here, in this review, the draw solutions are critically evaluated in the literature in terms of energy output as well as the method of regeneration used to recirculate them. A set of practical criteria has been suggested to appraise the adequacy of the solution for CLPRO application. It was concluded that NH 3 – CO 2 theoretically can produce 170 W/m 2 of power density. Inorganic draw solutes such as NaCl can generate high power density up to 87 W/m 2 . Organic draw solutes with their remarkably low reverse salt flux (RSF) have promising potential for future application in PRO. Similarly, the regeneration systems of the diluted draw solutions have also been reviewed and discussed. How the energy consumption of the regeneration process affects the feasibility of CLPRO is explained. For the specific case of osmotic heat engines (OHEs), when the energy of the regeneration process is supplied by heat waste, the range of applicability of the heat waste in CLPRO in terms of efficiency is defined and compared to Organic Rankine Cycle (ORC). The results showed that CLPRO has better efficiency than ORC for temperatures T < 80 °C, which makes it a promising process or low-grade heat energy recovery. In addition, a PRO-RO hybrid system coupled with solar power can reduce the net specific energy consumption (SEC) to 0.39 kWh/m 3 . The conditions that regeneration processes should operate under to make PRO viable are discussed in the last section. Overall, the study indicates the key factors for optimizing the performance of CLPRO process.

42 ENGINEERING↗

Continuous Purification of Molten Chloride Salt: Electrochemical Behavior of MgOHCl Reduction

We present a study on the electrochemical behavior of magnesium hydroxide (MgOH + ) reduction on a tungsten (W) cathode in molten chloride salt (MgCl 2 -KCl-NaCl) across the temperature range of 475 °C–525 °C. MgOH + , which forms within the salt upon exposure to moisture, is a leading cause of corrosion. Corrosion is a major barrier to deployment of chloride salts across a number of applications, including concentrating solar power plants and nuclear power plants. While pre-purification protocols have been developed to ensure MgOH + is removed from molten chloride salts prior to deployment, MgOH + forms in situ during operation of chloride-salt based plants. Thus, methods for continuous purification during plant operation are needed. Continuous electrochemical purification via electrolysis using a Mg anode and W cathode has been proposed, but little has been done to assess scalability. Here, we assess fundamental properties of electrochemical removal of MgOH + to enable future scale up of this method.

14 SOLAR ENERGY↗

Comparison of Minority Carrier Lifetime Measurements in Superstrate and Substrate CdTe PV Devices

We discuss typical and alternative procedures to analyze time-resolved photoluminescence (TRPL) measurements of minority carrier lifetime (MCL) with the hope of enhancing our understanding of how this technique may be used to better analyze CdTe photovoltaic (PV) device functionality. Historically, TRPL measurements of the fast recombination rate (t{sub 1}) have provided insightful correlation with broad device functionality. However, we have more recently found that t{sub 1} does not correlate as well with smaller changes in device performance, nor does it correlate well with performance differences observed between superstrate and substrate CdTe PV devices. This study presents TRPL data for both superstrate and substrate CdTe devices where both t{sub 1} and the slower TRPL decay (t{sub 2}) are analyzed. The study shows that changes in performance expected from small changes in device processing may correlate better with t{sub 2}. Numerical modeling further suggests that, for devices that are expected to have similar drift field in the depletion region, effects of changes in bulk MCL and interface recombination should be more pronounced in t{sub 2}. Although this technique may provide future guidance to improving CdS/CdTe device performance, it is often difficult to extract statistically precise values for t{sub 2}, and therefore t{sub 2} data may demonstrate significant scatter when correlated with performance parameters.

14 SOLAR ENERGY↗

Impact of form factor uncertainties on interpretations of coherent elastic neutrino-nucleus scattering data

The standard model coherent elastic neutrino-nucleus scattering (CEνNS) cross section is subject to nuclear form factor uncertainties, mainly driven by the root-mean-square radius of the neutron density distribution. Motivated by COHERENT phases I-III and future multi-ton direct detection dark matter searches, we evaluate these uncertainties in cesium iodide, germanium, xenon and argon detectors. We find that the uncertainties become relevant for momentum transfers q≳20 MeV and are essentially independent of the form factor parameterization. Consequently, form factor uncertainties are not important for CEνNS induced by reactor or solar neutrinos. Taking into account these uncertainties, we then evaluate their impact on measurements of CEνNS at COHERENT, the diffuse supernova background (DSNB) neutrinos and sub-GeV atmospheric neutrinos. We also calculate the relative uncertainties in the number of COHERENT events for different nuclei as a function of recoil energy. For DSNB and atmospheric neutrinos, event rates at a liquid argon detector can be uncertain to more than 5%. Finally, we consider the impact of form factor uncertainties on searches for nonstandard neutrino interactions, sterile neutrinos and neutrino generalized interactions. We point out that studies of new physics using CEνNS data are affected by neutron form factor uncertainties, which if not properly taken into account may lead to the misidentification of new physics signals. The uncertainties quantified here are also relevant for dark matter direct detection search

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wind load analysis of a new linear Fresnel receiver assembly design

A linear Fresnel collector includes a low-profile reflector array and a receiver assembly with one or more absorber tubes and an optional secondary reflector. This combined optical system concentrates sunlight and converts it into thermal energy. The design of a receiver assembly is critical to the performance of a linear Fresnel collector. A position deviation of a few centimeters for the receiver assembly can result in notably reduced performance, thus leading to a direct loss in revenue associated with thermal power production. Wind load is one of the most significant environmental factors that can alter the optical - and therefore thermal - performance of a solar power system due to displacements after installation. At the same time, an over-designed receiver assembly may add unnecessary construction cost to a typically high-cost-constrained system. Thus, wind load analysis is particularly important when considering optimal engineering design of a receiver assembly and its supporting structure to cost-effectively mitigate the impacts of wind. In this study, a detailed computational fluid dynamics (CFD) model is adopted to derive the wind load of a commercial linear Fresnel receiver assembly. This wind load is then used as a reference to optimize the detailed engineering design. The CFD model is first carefully developed and benchmarked within a critical regime toward turbulence. The drag force, lift force, and vortex-shedding frequencies are derived at both the operating and survival wind-speed limits for target project deployment locations. The wind load analysis results provide a valuable reference for future engineering design and prototyping.

17 WIND ENERGY↗