Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Seasonal and spatial variations in phytoplanktonic chlorophyll in eutrophic Mono Lake, California, measured with the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS)

The principal problem with application of airborne imaging spectrometers to lakes is the weak upwelling signal, especially when narrow spectral bands with high spatial resolution are sought. Furthermore, atmospheric path radiance dominates the signal received from dark targets such as lakes. Once atmospheric effects have been removed from the radiance received at the sensor, semi-empirical relationships can be developed to extract information about phytoplankton pigment concentrations for different underwater optical conditions. In lakes where concentrations of dissolved organics and suspended detritus may not co-vary with phytoplankton pigments, the many spectral channels of an imaging spectrometer such as AVIRIS are likely to be required to distinguish the various aquasols. The objectives of our study are to: (1) estimate the chlorophyll content of a lake with hundred-fold seasonal ranges in chlorophyll concentration using atmospherically corrected upwelling radiances derived from AVIRIS imagery, and (2) to examine spatial patterns in chlorophyll after reduction of the coherent noise in the imagery by filtering techniques.

Melack, John M.↗

JPL activities on development of acousto-optic tunable filter imaging spectrometer

Recent activities of JPL in the development of a new type of imaging spectrometers for earth observation and planetary exploration are reported. This instrument uses the acousto-optic tunable filter (AOTF) as high resolution and fast programmable bandpass filter. AOTF operates in the principle of acousto-optic interaction in an anisotropic medium. This filter can be tuned in sequential, random, and multiwavelength access modes, providing observational flexibility. The diffraction process in the filter generates two diffracted monochromatic beams with polarization orthogonal to each other, creating a unique capability to measure both polarimetric and spectral properties of the incoming light simultaneously with a single instrument. The device gives wide wavelength operations with reasonably large throughput. In addition, it is in a compact solid-state structure without moving parts, providing system reliability. These attractive features give promising opportunities to develop a new generation of airborne/spaceborne and ground, real-time, imaging spectrometer systems for remote sensing applications.

Cheng, Li-Jen↗

MinMap: An imaging spectrometer for high resolution compositional mapping of the Moon

MinMap has been selected by the Lunar Scout program to characterize and map the mineral composition of the Moon. The instrument will be built as a collaborative effort between Brown University, SETS Technology Inc., and Ball Aerospace Corp. MinMap is a visible to near-infrared imaging spectrometer that contains 192 spectral channels from 0.35-2.4 microns with signal to noise greater than 200 and 256 cross-track spatial elements. The spectrometer design has a 6 deg field of view (FOV) and utilizes grating dispersive elements and two dimensional detectors (no moving parts). An 'image cube' of data is produced that contains two dimensions of spatial information and one dimension of spectral information. All spectral channels and cross-track spatial elements are recorded simultaneously with spacecraft motion scanning the second spatial dimension. The high spectral resolution and continuous spectral range of MinMap are designed to measure the diagnostic absorption features of principal lunar minerals and their lithologic mixtures. Since the optical properties of lunar materials change in a regular manner upon exposure to the space environment, this spectral range is also quite sensitive to variations in exposure history (soil maturity). Nominal measurement stragegy is to obtain full global data of the Moon at 180 m/pixel from a 450 km polar orbit during the first month or two of operation. A 100 km orbit is anticipated for the remaining part of a 1 year mission allowing higher resolution data (approx. 80 m/pixel) to be obtained for targeted regions. MinMap exceeds LE x SWG's measurement recommendations and will provide the highest spatial resolution compositional map of lunar rocks and soils currently planned for orbital missions. Since all spectral channels are co-registered and obtained simultaneously, 'image cube' data swaths will be available for analysis almost immediately.

Pieters, C. M.↗

Low power, CMOS digital autocorrelator spectrometer for spaceborne applications

A 128-channel digital autocorrelator spectrometer using four 32 channel low power CMOS correlator chips was built and tested. The CMOS correlator chip uses a 2-bit multiplication algorithm and a full-custom CMOS VLSI design to achieve low DC power consumption. The digital autocorrelator spectrometer has a 20 MHz band width, and the total DC power requirement is 6 Watts.

Chandra, Kumar↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

Planetary Instrument Definition and Development Program (PIDDP). Instrument for future planetary flight missions: A visible-infrared imaging spectrometer for planetary missions

The objective of this project is to develop and prove a small, light-weight, efficient imaging spectrometer design to cover the VIS/NIR spectral range for applications particularly but not exclusively to NASA inner solar system space missions. A design and a brassboard prototype will be developed and tested. Progress over the first year of this project includes design specification, optical design layout, grating specifications, infrared detector selection, and mechanical design. Mechanical and grating manufacturing drawings were begun. We developed an agreement in principle to cooperate with the German space group, DLR, to apply some of their electronics microminiaturization technology to this imaging spectrometer project, mostly or entirely at their expense. Funds from NASA for the second year of this effort have been received and the effort is on track. Release of funds for the third year of this award will be requested later this year in order to accelerate this work and bring it to a conclusion in time for new NASA missions considerations as well as to make effective use of the DLR contributions.

Mccord, Thomas B.↗

JPL Fourier transform ultraviolet spectrometer

The Fourier Transform Ultraviolet Spectrometer (FTUVS) is a new high resolution interferometric spectrometer for multiple-species detection in the UV, visible and near-IR. As an OH sensor, measurements can be carried out by remote sensing (limb emission and column absorption), or in-situ sensing (long-path absorption or laser-induced fluorescence). As a high resolution detector in a high repetition rate (greater than 10 kHz) LIF system, OH fluorescence can be discriminated against non-resonant background emission and laser scatter, permitting (0, 0) excitation.

Cageao, R. P.↗

Solar measurements from the Airglow-Solar Spectrometer Instrument (ASSI) on the San Marco 5 satellite

The analysis of the solar spectral irradiance from the Airglow-Solar Spectrometer Instrument (ASSI) on the San Marco 5 satellite is the focus for this research grant. A pre-print copy of the paper describing the calibrations of and results from the San Marco ASSI is attached to this report. The calibration of the ASSI included (1) transfer of photometric calibration from a rocket experiment and the Solar Mesosphere Explorer (SME), (2) use of the on-board radioactive calibration sources, (3) validation of the ASSI sensitivity over its field of view, and (4) determining the degradation of the spectrometers. We have determined that the absolute values for the solar irradiance needs adjustment in the current proxy models of the solar UV irradiance, and the amount of solar variability from the proxy models are in reasonable agreement with the ASSI measurements. This research grant also has supported the development of a new solar EUV irradiance proxy model. We expected that the magnetic flux is responsible for most of the heating, via Alfen waves, in the chromosphere, transition region, and corona. From examining time series of solar irradiance data and magnetic fields at different levels, we did indeed find that the chromospheric emissions correlate best with the large magnetic field levels.

Woods, Thomas N.↗

Airborne astronomy with a 150 micrometer - 500 micrometer heterodyne spectrometer

This report summarizes work done under NASA Grant NAG2-254 awarded to the University of California. The project goal was to build a far-infrared heterodyne spectrometer for NASA's Kuiper Airborne Observatory (KAO), and to use this instrument to observe atomic and molecular spectral lines from the interstellar medium. This goal was successfully achieved; the spectrometer is now in routine use aboard the KAO. Detections of particular note have been the 370 micrometers line of neutral atomic carbon, the 158 micrometers transition of ionized carbon, many of the high-J rotational lines of 12CO and 13CO between J=9-8 and J=22-21, the 119 micron ground-state rotational line of OH, and the 219 micron ground-state rotational line of H2D(+). All of these lines were observed at spectral resolutions exceeding 1 part in 10(exp 6), thereby allowing accurate line shapes and Doppler velocities to be measured.

Betz, A. L.↗

Airborne tunable diode laser spectrometer for trace-gas measurement in the lower stratosphere

This paper describes the airborne tunable laser absorption spectrometer, a tunable diode laser instrument designed for in situ trace-gas measurement in the lower stratosphere from an ER-2 high-altitude research aircraft. Laser-wavelength modulation and second-harmonic detection are employed to achieve the required constituent detection sensitivity. The airborne tunable laser absorption spectrometer was used in two polar ozone campaigns, the Airborne Antarctic Ozone Experiment and the Airborne Arctic Stratospheric Expedition, and measured nitrous oxide with a response time of 1 s and an accuracy not greater than 10 percent.

Podolske, James↗

Ground based NO2 and O3 measurements by visible spectrometer at Syowa Base (69 deg S), Antarctica

The column amounts of NO2 and ozone have been measured using visible spectroscopy at Syowa Base (69 deg S) since March 1990. Ozone was also measured at the same location with a Dobson spectrometer as well as ozonesondes being flown regularly. The characteristic features of the seasonal and diurnal variations of NO2 are presented. The column ozone values from the visible spectrometers are compared with the Dobson data. The very low values of NO2 in midwinter and early spring are consistent with the conditions predicted to be needed for heterogeneous ozone destruction in early spring. In late spring and summer of 1991, NO2 amounts were considerably smaller than in 1990, presumably due to the effect of Mt. Pinatubo eruption.

Kondo, Y.↗

Measurements of stratospheric composition using a star pointing spectrometer

Measurements of stratospheric composition have been made with a novel star-pointing spectrometer. The instrument consists of a telescope that focuses light from stars, planets, or the moon onto a spectrometer and two dimensional CCD array detector. Atmospheric absorptions can be measured, from which atmospheric columns of several gases can be determined. The instrument was deployed in Abisko, 69 deg N, during the European Arctic Stratospheric Ozone Experiment (EASOE). The instrument has the potential for measuring O3, OClO, NO2, and NO3. In this paper, a method for the retrieval of vertical columns is described, and some examples of ozone measurements given.

Fish, Deb J.↗

Radiative transfer code based estimation of atmospheric parameters for inversion of imaging spectrometer measured radiance to apparent surface reflectance

Surface reflectance is required to quantitatively investigate molecular absorption and particle scattering properties of materials on the Earth's surface. Atmospheric aerosol optical depth, surface pressure and water vapor are required to constrain a radiative transfer code for the inversion of measured spectral radiance to apparent surface reflectance. A suite of algorithms using nonlinear least squares fitting techniques are described that directly estimate these atmospheric parameters from spectral radiance measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The derived atmospheric parameters are used to constrain a radiative transfer code for the inversion of the imaging spectrometer radiance to apparent reflectance. The derived apparent reflectance is validated with respect to in situ measurement on the same target.

Green, Robert O.↗

Recovery of reflectance from imaging spectrometer measured radiance using a radiative transfer code

Radiance data were acquired over part of the Clark Mountain Range, California in 1990 by the Airborne Visible Infrared Imaging Spectrometer (AVIRIS). From these calibrated radiance data, the lateral distribution of water vapor in precipitable mm was recovered through analysis of the 940 nm water absorption. Surface pressure height was calculated from the 760 nm oxygen absorption band in the AVIRIS data. Surface slopes are estimated from relative elevations derived from the equivalent water vapor elevation for a standard atmosphere. Atmospheric optical depths measured at the Mountain Pass site in these data are extended to the entire region and varied based on the calculated surface pressure elevation. These parameters, derived from every AVIRIS spatial element, are used to constrain the LOWTRAN 7 radiative transfer code for the recovery of surface reflectance. Once transformed to reflectance, the imaging spectrometer data may be analyzed quantitatively for determination of surface composition, and compared with reflectance measurements acquired from different locations, times, and instruments.

Green, Robert O.↗

Field observations using an AOTF polarimetric imaging spectrometer

This paper reports preliminary results of recent field observations using a prototype acousto-optic tunable filter (AOTF) polarimetric imaging spectrometer. The data illustrate application potentials for geoscience. The operation principle of this instrument is different from that of current airborne multispectral imaging instruments, such as AVIRIS. The AOTF instrument takes two orthogonally polarized images at a desired wavelength at one time, whereas AVIRIS takes a spectrum over a predetermined wavelength range at one pixel at a time and the image is constructed later. AVIRIS does not have any polarization measuring capability. The AOTF instrument could be a complement tool to AVIRIS. Polarization measurement is a desired capability for many applications in remote sensing. It is well know that natural light is often polarized due to various scattering phenomena in the atmosphere. Also, scattered light from canopies is reported to have a polarized component. To characterize objects of interest correctly requires a remote sensing imaging spectrometer capable of measuring object signal and background radiation in both intensity and polarization so that the characteristics of the object can be determined. The AORF instrument has the capability to do so. The AOTF instrument has other unique properties. For example, it can provide spectral images immediately after the observation. The instrument can also allow observations to be tailored in real time to perform the desired experiments and to collect only required data. Consequently, the performance in each mission can be increased with minimal resources. The prototype instrument was completed in the beginning of this year. A number of outdoor field experiments were performed with the objective to evaluate the capability of this new technology for remote sensing applications and to determine issues for further improvements.

Cheng, Li-Jen↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Recent improvements to the sensor

AVIRIS is a NASA-sponsored Earth-looking imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory. Spectral, radiometric and geometric characteristics of the data acquired by AVIRIS are given in Table 1. AVIRIS has been operational since 1989, however in each year since 1989 major improvements have been completed in most of the subsystems of the sensor. As a consequence of these efforts, the capabilities of AVIRIS to acquire and deliver calibrated imaging spectrometer data of high quality have improved significantly over those in 1989. Improvements to AVIRIS prior to 1992 have been described previously (Porter et al., 1990, Chrien et al., 1991, & Chrien et al., 1992). In the following sections of this paper we describe recent and planned improvements to AVIRIS in the sensor task.

Chrien, Thomas G.↗

ASCA solid state imaging spectrometer observations of O stars

We report ASCA Solid State Imaging Spectrometer (SIS) x-ray observations of the O stars delta Ori and lambda Ori. The energy resolution of the SIS allows us to resolve features in the O star x-ray spectra which are not apparent in spectra obtained by x-ray spectrometers with lower energy resolution. SIS spectra from both stars show evidence of line emission, suggesting the thermal nature of the x-ray source. However, the observed line strengths are different for the two stars. The observed stellar x-ray spectra are not well described by isothermal models although absorbed thermal emission models with two or more temperatures can provide an adequate fit to the data. For both stars we present evidence of absorbing columns significantly larger than the known ISM columns, indicative of absorption by a circumstellar medium, presumably the stellar winds. In addition, the lambda Ori spectrum shows the presence of emission at energies greater than 3 keV which is not seen in the delta Ori spectrum.

Corcoran, M. F.↗

STS-46 plasma composition measurements using the EOIM-3 mass spectrometer

One of the active instruments incorporated into the Evaluation of Oxygen Interactions with Materials - 3 experiment was a quadrupole mass spectrometer. The primary objectives for this instrument, which was built by the Air Force Phillips Laboratory and was a veteran of the STS-4 flight in 1982, were to quantify the flux of atomic oxygen striking the test surfaces in the EOIM-3 payload and to detect surface reaction products from the materials in the carousel. Other speakers in this session have covered the results of these experiments. Prior to the 40-hour-long dedicated EOIM-3 mission segment at the end of the STS-46 flight, the authors used the mass spectrometer to make measurements of ion and neutral gas composition in the shuttle environment. About 25 hours of data were collected during a variety of mission events, including Eureca deployment at high altitude and many tethered satellite system operations.

Hunton, Donald E.↗