Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A stochastic downscaling approach for generating high-frequency solar irradiance scenarios

Solar power is increasingly cost viable with solar photovoltaic (PV) installations becoming commonplace. PV planning and operational studies, however, require high-frequency solar irradiance scenarios to understand potential electric grid impacts due to the variability and uncertainty of the underlying solar resource. Existing remote sensing solar data products are often available over large spatial domains, but are limited in temporal resolution. For example, the global horizontal irradiance (GHI) component contained within the National Solar Radiation Database (NSRDB) is available at time resolution of 30 min on an approximately four-kilometer grid. In contrast, substantial solar variability is present at finer time scales and this article describes an algorithm to stochastically generate one-minute GHI from widely available sub-hourly NSRDB. A generalized linear modeling (GLM) framework is proposed, which includes non-Gaussian mixtures, and extends the literature involving the synthesis of GHI data. The model is trained on a set of sample locations around Oregon, USA, and validated across the USA using both the Surface Radiation Budget Network (SURFRAD) dataset and Solar Radiation Monitoring Laboratory (SRML) network. Simulated ensembles show good coverage properties and temporal correlation structure. The resulting downscaled ensembles allow for understanding the unpredictable variability inherent in GHI at locations without direct measurements. Here, future work can leverage the algorithm as part of a stochastic optimization of electric grid operations with high-penetration PV systems.

14 SOLAR ENERGY↗

5 kHz thermometry in a swirl-stabilized gas turbine model combustor using chirped probe pulse femtosecond CARS. Part 2. Analysis of swirl flame dynamics

We have performed a detailed analysis of the temperature field in a turbulent swirl flame operating with a self-excited thermo-acoustic instability. The temperature field was measured using 5 kHz chirped-probe-pulse (CPP) femtosecond (fs) coherent anti-Stokes Raman scattering (CARS). The measurements are described in detail in the part 1 companion article. In this paper, part 2, a detailed analysis of the time-resolved temperature measurements and simultaneous pressure measurements is performed to provide insight into the dynamics and structure of the swirl-stabilized flame. Here this work is the first to capture the dynamics of the flame, flow, and coupled flow-flame processes using high-fidelity, spatially- and temporally-resolved thermometry in a flame of practical relevance. The time-averaged contour plot of the temperature field indicates that the flame is very flat and stabilizes approximately 10 mm downstream of the burner face. In this region, there are very significant temperature fluctuations indicating a very high level of unsteadiness. The temperature probability distribution functions (PDFs) are clearly bimodal in this region near the injector face. A Fourier analysis of the temperature time series revealed multiple coherent oscillatory modes. The strongest oscillation was found to be coherent and in-phase with an acoustic resonance at 314 Hz, as expected from the Rayleigh criteria for the unstable flame. An analysis of the phase-conditioned average temperature fields clearly shows an axial pumping of low-temperature reactants, which are consumed after a convective delay and result in a spike in the global heat-release rate. Continued analysis also revealed a 438 Hz oscillation that was found to correspond with the dynamics of convective transport by a helical precessing vortex core (PVC). The structure of the PVC, and its interaction with the flame, were studied based on the presence of this characteristic frequency in the power spectral densities computed throughout the flow. The precision and time-resolution of the CPP fsCARS measurements was also sufficient to enable computation of the integral time-scales as well as the PDFs of the temporal temperature gradients. A sample of state space trajectories were used to provide insight into the nature of coupling between the narrowband acoustic resonance and the broadband spectrum of turbulent flame processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Femtosecond all-optical synchronization of an X-ray free-electron laser

Many advanced applications of X-ray free-electron lasers require pulse durations and time resolutions of only a few femtoseconds. To generate these pulses and to apply them in time-resolved experiments, synchronization techniques that can simultaneously lock all independent components, including all accelerator modules and all external optical lasers, to better than the delivered free-electron laser pulse duration, are needed. Here we achieve all-optical synchronization at the soft X-ray free-electron laser FLASH and demonstrate facility-wide timing to better than 30 fs r.m.s. for 90 fs X-ray photon pulses. Crucially, our analysis indicates that the performance of this optical synchronization is limited primarily by the free-electron laser pulse duration, and should naturally scale to the sub-10 femtosecond level with shorter X-ray pulses.

43 PARTICLE ACCELERATORS↗

Multifrequency-resolved Hanbury Brown–Twiss effect

The Hanbury Brown–Twiss (HBT) effect holds a pivotal place in intensity interferometry and gave a seminal contribution to the development of quantum optics. To observe such an effect, both good spectral and timing resolutions are necessary. Most often, the HBT effect is observed for a single frequency at a time due to its limitations in dealing with multifrequencies simultaneously, halting and limiting some applications. Here, we report a fast and data-driven spectrometer built with a one-dimensional array of single-photon-sensitive avalanche diodes. We report observing the HBT effect for multiple frequencies at the same time. In particular, we observe the HBT effect for up to five lines of the Ne spectrum, but this can be improved upon to include more lines. Our work represents a major step in making spectral binning and multifrequency HBT more widely available. The technology we present can benefit both classical and quantum applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultrafast formation of domain walls of a charge density wave in SmTe 3

We study ultrafast x-ray diffraction on the charge density wave (CDW) of SmTe 3 using an x-ray free-electron laser. The high momentum and time resolution afforded by the x-ray laser enabled capturing fine wave-vector and time-dependent features of the CDW that originate from fast (in time) and sharp (in real space) variations of the CDW lattice distortion, which we attribute to an inversion of the order parameter. These domain inversions occur near the surface and are caused by the short penetration depth of the near-infrared pump with the wavelength centered at 800 nm, resulting in CDW domain walls perpendicular to the sample surface. These domain walls break the CDW long-range order on the scale of the x-ray probe depth, controlled experimentally by the x-ray incidence angle and suppress the diffraction intensity of the CDW for times much longer than the ~1–ps recovery of the electronic gap observed in time and angle-resolved photoemission spectroscopy. We model the spatial and temporal dependences of the order parameter using a simple Ginzburg-Landau model with all the parameters obtained from the published literature. We find reasonable agreement between the calculated and the measured diffraction across the momentum, time, fluence, and incidence angle dependence without adjusting any parameters. In conclusion, we reconstruct the spatial and temporal dependences of the lattice order parameter and find that at long times, depending on the pump fluence, multiple domain walls remain at distances of a few nanometers from the surface.

36 MATERIALS SCIENCE↗

Calibration and Performance of the ICARUS Detector at Fermilab

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. Precise detector calibration is essential for reliable energy reconstruction and for maximizing the physics reach of the experiment. In this talk, I will describe the energy and timing calibration procedures developed at ICARUS. Thanks to the abundant flux of cosmic ray muons at the surface, the TPC response to ionization charge has been equalized across the detector, removing non-uniformities and in-transparency effects. A novel data-driven procedure has been used to tune the simulation of ionization signals and electronics noise yielding close agreement between Monte Carlo and data with minimal residual bias in reconstructed charge. In addition, the light detection system has been calibrated to sub-nanosecond timing resolution. This precision enables efficient cosmic background rejection and accurate synchronization of neutrino interactions with the time structure of both the Booster Neutrino Beam (BNB) and Neutrinos at the Main Injector (NuMI) beam. Together, these efforts demonstrate the robust performance of the detector and provide critical experience for future large LArTPCs, such as DUNE.

Vicenzi, Matteo [Brookhaven]↗

Millisecond time variations in hard X-ray solar flares

The results of a search for fast spikes in 2830 hard X-ray solar flares as observed with the hard X-ray burst spectrometer on the Solar Maximum Mission (SMM) are presented. Hundreds of fast spikes with durations of less than 1 sec have been detected at time resolutions of 128 msec and 10 msec. Fast spikes have been detected with rise and decay times as short as 20 msec and with widths as short as 45 msec. They are the fastest hard X-ray variations yet seen from the sun. The observations of such fast variations place new constraints on the physical nature of the source, and these observations and constraints are discussed in terms of nonthermal and thermal models of flares.

Kiplinger, A. L.↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limiting noise fraction in PDV measurements

The limiting frequency resolution of a PDV measurement is: σf = $\sqrt\frac{6 η}{fsτ^3π}$ where f s is the sample rate, τ is the analysis time duration, and 11 is the noise fraction. Although T is a strong lever for reducing uncertainty, this parameter must be kept small to preserve time resolution. Consider a PDV measurement with sampled at 80 GS/s and analyzed in 1 ns durations. A 1% noise fraction corresponds to 0.87 MHz of frequency uncertainty, which at 1550 nm works out to 0.68 m/s. A 10% noise fraction has a limiting velocity resolution of about 7 m/s; for comparison, a VISAR system with similar response time (0.5 ns delay, 532 m/s fringe constant) would have a limiting uncertainty of 5-6 m/s. Noise fractions of 10-20% or less are desirable for measurements at this time scale.

42 ENGINEERING↗

The High Resolution Spectrograph for the Space Telescope

The High Resoltuion Spectrograph (HRS) in conjunction with the Space Telescope (ST), extends ultraviolet astronomical spectroscopy to higher spectra, spatial, and time resolutions than previously achieved, as well as to fainter and more distant celestial objects. Other significant advances inherent in the instrument are high photometric accuracy and efficient operation via exposure meter control and real time rejection of bad data. These capabilities are provided to accomplish the scientific programs of the HRS investigation definition team, which concern the interstellar medium, stellar winds, and evolutionary aspects of stellar atmosphere studies; the determination of chemical abundances relevant to stellar evolution; the investigation of quasars and Seyfert galaxy nuclei; and the analysis of the atmospheres of solar system objects, including comets.

Brandt, J. C.↗

Large Observatory for X-ray Timing (LOFT-P): A Probe-Class Mission Concept Study

LOFT-P is a mission concept for a NASA Astrophysics Probe-Class (less than $1B) X-ray timing mission, based on the LOFT M-class concept originally proposed to ESA's M3 and M4 calls. LOFT-P requires very large collecting area, high time resolution, good spectral resolution, broadband spectral coverage (2-30 keV), highly flexible scheduling, and an ability to detect and respond promptly to time-critical targets of opportunity. Many of LOFTP's targets are bright, rapidly varying sources, so these measurements are synergistic to imaging and high-resolution spectroscopy instruments, addressing much smaller distance scales than are possible without very long baseline X-ray interferometry, and using complementary techniques to address the geometry and dynamics of emission regions. LOFT-P was presented as an example mission to the head of NASA's Astrophysics Division, to demonstrate the strong community support for creation of a probe-class, for missions costing between $500M and $1B. We submitted a white paper4 in response to NASA PhysPAG's call for white papers: Probe-class Mission Concepts, describing LOFT-P science and a simple extrapolation from the ESA study costs. The next step for probe-class missions will be input into the NASA Astrophysics Decadal Survey to encourage the creation of a probe-class opportunity. We report on a 2016 study by MSFC's Advanced Concepts Office of LOFT-P, a US-led probe-class LOFT concept.

x-ray↗

CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from 8.2% (1 × 1 × 1 mm{sup 3}) to 58.6% (10 × 10 × 10 mm{sup 3}) and decreases applying a photon detection threshold of 5/10/20 photons to 6.3%/4.3%/0.7% and 49.3%/30.4%/2.8%, respectively. The detection rate in the six photodetectors is uniform due to the nearly isotropic cone emission. Most cones originated after a photoelectric effect interaction, with two dominating peaks for the kinetic energy of the electron at 422.99 and 441.47 keV. The detection distance between same-event photons defines the spatial resolution of the detector required for individual photon recognition, with 20% of the detected photons having their closest neighbor within a distance of 5% of the length of the cube. Same-event photons are detected within a time window whose width is determined by the crystal size, with values of 30 and 150 ps for a 1 × 1 × 1 mm{sup 3} and a 10 × 10 × 10 mm{sup 3} cube, respectively. The DOI reconstruction has an accuracy of approximately 23% of the length of the cube, with an average value of 2.2 mm for a 10 × 10 × 10 mm{sup 3} CHERENCUBE. Conclusions: The proposed concept requires a detector with high photodetection efficiency. The structure of the sensitive surface of the detector should be a two dimensional array of microcells, able to provide individual detection coordinates and time stamps. The microcell size determines the ability to recognize individual photons, influencing detection efficiency. The 3D DOI recognition relies on the accuracy of the time stamps and detection coordinates, without the need for a recognition of the projected patterns of photons. The refractive index of the material defines a detector intrinsic energy-based rejection of scattered PET events at the cost of reduced sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UWB Tracking System Design for Free-Flyers

This paper discusses an ultra-wideband (UWB) tracking system design effort for Mini-AERCam (Autonomous Extra-vehicular Robotic Camera), a free-flying video camera system under development at NASA Johnson Space Center for aid in surveillance around the International Space Station (ISS). UWB technology is exploited to implement the tracking system due to its properties, such as high data rate, fine time resolution, and low power spectral density. A system design using commercially available UWB products is proposed. A tracking algorithm TDOA (Time Difference of Arrival) that operates cooperatively with the UWB system is developed in this research effort. Matlab simulations show that the tracking algorithm can achieve fine tracking resolution with low noise TDOA data. Lab experiments demonstrate the UWB tracking capability with fine resolution.

Ni, Jianjun↗

Time Evolving Fission Chain Theory and Fast Neutron and Gamma-Ray Counting Distributions

Here, we solve a simple theoretical model of time evolving fission chains due to Feynman that generalizes and asymptotically approaches the point model theory. The point model theory has been used to analyze thermal neutron counting data. This extension of the theory underlies fast counting data for both neutrons and gamma rays from metal systems. Fast neutron and gamma-ray counting is now possible using liquid scintillator arrays with nanosecond time resolution. For individual fission chains, the differential equations describing three correlated probability distributions are solved: the time-dependent internal neutron population, accumulation of fissions in time, and accumulation of leaked neutrons in time. Explicit analytic formulas are given for correlated moments of the time evolving chain populations. The equations for random time gate fast neutron and gamma-ray counting distributions, due to randomly initiated chains, are presented. Correlated moment equations are given for both random time gate and triggered time gate counting. There are explicit formulas for all correlated moments are given up to triple order, for all combinations of correlated fast neutrons and gamma rays. The nonlinear differential equations for probabilities for time dependent fission chain populations have a remarkably simple Monte Carlo realization. A Monte Carlo code was developed for this theory and is shown to statistically realize the solutions to the fission chain theory probability distributions. Combined with random initiation of chains and detection of external quanta, the Monte Carlo code generates time tagged data for neutron and gamma-ray counting and from these data the counting distributions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Astrophysical applications of high angular resolution array-telescopes

The air shower array-telescopes which are currently being used to search for and study point sources of UHE gamma-rays have angular resolution similar to 1 deg, limited by either the small total area of particle detectors or poor timing resolution. As the signal to noise ratio depends sensitively on the angular resolution, it seems certain that this figure will quickly be surpassed when second generation instruments come into operation. Since the trajectories of galactic cosmic rays with E 100,000 GeV are practically straight lines on scales of 1 A.U. or less, these new instruments will be able to observe a shadow cast by the Moon (angular diameter 0.5 deg). Although the angular diameter of the Sun is practically the same, its shadow will be more complex because of its magnetic field. Thus, high angular resolution observations of the Sun afford a means of investigating the solar magnetic field, and also the charge composition of cosmic rays, including the ratio of antiprotons to protons.

Linsley, J.↗

SGR J1550-5418 Bursts Detected with the Fermi Gamma-Ray Burst Monitor during Its Most Prolific Activity

We have performed detailed temporal and time-integrated spectral analysis of 286 bursts from SGR J1550-5418 detected with the Fermi Gamma-ray Burst Monitor (GBM) in 2009 January, resulting in the largest uniform sample of temporal and spectral properties of SGR J1550-5418 bursts. We have used the combination of broadband and high time-resolution data provided with GBM to perform statistical studies for the source properties.We determine the durations, emission times, duty cycles, and rise times for all bursts, and find that they are typical of SGR bursts. We explore various models in our spectral analysis, and conclude that the spectra of SGR J15505418 bursts in the 8-200 keV band are equally well described by optically thin thermal bremsstrahlung (OTTB), a power law (PL) with an exponential cutoff (Comptonized model), and two blackbody (BB) functions (BB+BB). In the spectral fits with the Comptonized model, we find a mean PL index of -0.92, close to the OTTB index of -1. We show that there is an anti-correlation between the Comptonized E(sub peak) and the burst fluence and average flux. For the BB+BBfits, we find that the fluences and emission areas of the two BB functions are correlated. The low-temperature BB has an emission area comparable to the neutron star surface area, independent of the temperature, while the high temperature BB has a much smaller area and shows an anti-correlation between emission area and temperature.We compare the properties of these bursts with bursts observed from other SGR sources during extreme activations, and discuss the implications of our results in the context of magnetar burst models.

bursts↗

Compact field programmable gate array-based pulse-sequencer and radio-frequency generator for experiments with trapped atoms

We present a compact field-programmable gate array (FPGA) based pulse sequencer and radio-frequency (RF) generator suitable for experiments with cold trapped ions and atoms. The unit is capable of outputting a pulse sequence with at least 32 transistor-transistor logic (TTL) channels with a timing resolution of 40 ns and contains a built-in 100 MHz frequency counter for counting electrical pulses from a photo-multiplier tube. There are 16 independent direct-digital-synthesizers RF sources with fast (rise-time of ∼60 ns) amplitude switching and sub-mHz frequency tuning from 0 to 800 MHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Return flows from beaver ponds enhance floodplain-to-river metals exchange in alluvial mountain catchments

River to floodplain hydrologic connectivity is strongly enhanced by beaver- (Castor canadensis) engineered channel water diversions. The hydroecological impacts are wide ranging and generally positive, however, the hydrogeochemical characteristics of beaver-induced flowpaths have not been thoroughly examined. Using a suite of complementary ground- and drone-based heat tracing and remote sensing methodology we characterized the physical template of beaver-induced floodplain exchange for two alluvial mountain streams near Crested Butte, Colorado, USA. A flowpath-oriented perspective to water quality sampling allowed characterization of the chemical evolution of channel water diverted through floodplain beaver ponds and ultimately back to the channel in 'beaver pond return flows'. Subsurface return flow seepages were universally suboxic, while ponds and surface return flows showed a range of oxygen concentration due to in-situ photosynthesis and atmospheric mixing. Median concentrations of reduced metals: manganese (Mn), iron (Fe), aluminum (Al), and arsenic (As) were substantially higher along beaver-induced flowpaths than in geologically controlled seepages and upstream main channel locations. The areal footprint of reduced return seepage flowpaths were imaged with surface electromagnetic methods, indicating extensive zones of high-conductivity shallow groundwater flowing back toward the main channels and emerging at relatively warm bank seepage zones observed with infrared. Multiple-depth redox dynamics within one focused seepage zone showed coupled variation over time, likely driven by observed changes in seepage rate that may be controlled by pond stage. High-resolution times series of dissolved Mn and Fe collected downstream of the beaver-impacted reaches demonstrated seasonal dynamics in mixed river metal concentrations. Al time series concentrations showed proportional change to Fe at the smaller stream location, indicating chemically reduced flowpaths were sourcing Al to the channel. Overall our results indicated beaver-induced floodplain exchanges create important, and perhaps dominant, transport pathways for floodplain metals by expanding chemically-reduced zones paired with strong advective exchange.

58 GEOSCIENCES↗