Detection of multi-modal Doppler spectra – Part 1: Establishing characteristic signals in radar moment data

Vertically pointing millimeter-wavelength radars provide a wealth of information about cloud and precipitation particle properties. Doppler spectral data can inform on how particles of varying vertical velocities contribute to the total backscattered power observed. It is more computationally cost effective to process moment data instead of spectra data, but doing so leaves valuable information on the cutting room floor. To confidently identify a multi-modal spectra event, in which two or more modes are present within a layer, Doppler spectral data are essential. This means long-term identification of layers featuring multi-modal spectra can be cost prohibitive. To address this, we explore three multi-modal spectra cases from winter precipitation events to determine characteristic signatures of these layers in the moment data averaged over short time periods (∼ 145 s) and explore how these layers differ from the rest of the vertical profiles. We find that the mean spectrum width and the standard deviation of mean Doppler velocity can be used to determine whether or not a layer is multi-modal. In particular, multi-modal layers in mixed-phase and ice clouds feature larger mean spectrum width (exceeding 0.17 m s −1 ) and smaller standard deviation of the mean Doppler velocity (below 0.1 m s −1 ). In Part 1 of this study, the identification criteria and methods are described. In Part 2 (Wugofski and Kumjian, 2025), we perform a verification of the method for three years of vertically pointing radar data, and explore the meteorological conditions associated with identified multi-modal spectral events.

Wugofski, Sarah [Pennsylvania State Univ., Univers↗

Phenomena Identification and Ranking Table (PIRT) for Fluoride High-Temperature Reactor (FHR) Neutronics

The deployment of Fluoride (salt-cooled) High Temperature Reactors (FHRs) has many potential benefits such as improved safety, improved economics, and a diversification of the energy portfolio because of its capability to supply industrial process heat. However, significant challenges remain before this class of reactors can be deployed, mostly related to its technology readiness. A recent study identified several areas in need of further development in order to advance the technology. These include the verification and validation of neutronics and thermal hydraulics modeling and simulation tools in support of design, safety analysis and licensing. The focus of this paper is to summarize the issues for verification and validation of neutronics tools. Current tools for neutronics analysis of LWRs are inadequate for the simulation of salt cooled reactors. The methodologies developed for the high temperature gas cooled reactors (HTGRs) have some relevance for FHRs because of the similarities between the two reactors such as graphite block structure, encapsulated fuel particles, and high operating temperatures. However, they are not sufficient for the accuracy desired of a code for licensing as they have a number of important differences neutronically, such as the use of liquid salt containing beryllium as a coolant and their unique fuel configuration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Phenomena Identification and Ranking Table (PIRT) for Fluoride High-Temperature Reactor (FHR) Neutronics

The deployment of Fluoride (salt-cooled) High Temperature Reactors (FHRs) has many potential benefits such as improved safety, improved economics, and a diversification of the energy portfolio because of its capability to supply industrial process heat. However, significant challenges remain before this class of reactors can be deployed, mostly related to its technology readiness. A recent study identified several areas in need of further development in order to advance the technology. These include the verification and validation of neutronics and thermal hydraulics modeling and simulation tools in support of design, safety analysis and licensing. The focus of this paper is to summarize the issues for verification and validation of neutronics tools. Current tools for neutronics analysis of LWRs are inadequate for the simulation of salt cooled reactors. The methodologies developed for the high temperature gas cooled reactors (HTGRs) have some relevance for FHRs because of the similarities between the two reactors such as graphite block structure, encapsulated fuel particles, and high operating temperatures. However, they are not sufficient for the accuracy desired of a code for licensing as they have a number of important differences neutronically, such as the use of liquid salt containing beryllium as a coolant and their unique fuel configuration. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation Tests of the Gamma Library of the ARC Software Package (Rev.1)

As part of the verification and validation (V&V) efforts of the Argonne Reactor Code (ARC) software system to support the Versatile Test Reactor (VTR) project of the U.S. Department of Energy (DOE), work has been performed to verify and validate the gamma (or photon) library of the multigroup cross section generation code MC 2 -3 of the ARC system, which is the essential part of the coupled neutron and gamma heating calculations to determine the heat generation rate or power distribution in the core. This V&V study was carried out in three steps: 1) review of the procedures and utility programs for generating the MC 2 -3 gamma library, 2) verification tests of cross sections and KERMA factors by comparing the total heat generation rate of coupled neutron and gamma calculation with that obtained with reaction Q values under the assumption of local gamma energy deposition and by comparing the prompt heat generation rate with that calculated with the MCNP6.2 code, and 3) validation tests of cross sections and KERMA factors by analyzing the ZPPR-15D gamma dose data measured with thermoluminescent dosimeters (TLD).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation Of Human Body Radiation Using Phantom Model On Beam lowbar nrc And Verification On Dosxyz lowbar nrc

The optimum dose can be produced by measuring and analysis of the dose distribution from the source. The energy of the source must be maximum for the target cell, and must minimum for the tissues that surround the target cell. In this study, the phantom model has a cylindrical shape with 20 cm radius and 19 cm depth. The calculation is done where photon beam energy is 6 MeV with 3 different radius beam; 0.3 cm, 5 cm, and 15 cm. The verification was done with a model cube film which was arranged by element voxel which made by Mylar and Ag. The results of this simulation shows the difference dose distribution for radius beam 0.5 cm, 3 cm, and 15 cm that is caused by particle density and penumbra effect. And for all beam radiuses, the maximum dose (100%) happens in 1.5-2 mm depth from film model.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental verification of the Kruskal-Shafranov stability limit in line-tied partial-toroidal plasmas

The stability properties of partial-toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., q{sub a} = 1).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

We underestimate uncertainties in our predictions.

Prediction is defined in the American Heritage Dictionary as follows: 'To state, tell about, or make known in advance, especially on the basis of special knowledge.' What special knowledge do we demand of modeling and simulation to assert that we have a predictive capability for high consequence applications? The 'special knowledge' question can be answered in two dimensions: the process and rigor by which modeling and simulation is executed and assessment results for the specific application. Here we focus on the process and rigor dimension and address predictive capability in terms of six attributes: (1) geometric and representational fidelity, (2) physics and material model fidelity, (3) code verification, (4) solution verification, (5) validation, and (6) uncertainty quantification. This presentation will demonstrate through mini-tutorials, simple examples, and numerous case studies how each attribute creates opportunities for errors, biases, or uncertainties to enter into simulation results. The demonstrations will motivate a set of practices that minimize the risk in using modeling and simulation for high-consequence applications while defining important research directions. It is recognized that there are cultural, technical, infrastructure, and resource barriers that prevent analysts from performing all analyses at the highest levels of rigor. Consequently, the audience for this talk is (1) analysts, so they can know what is expected of them, (2) decision makers, so they can know what to expect from modeling and simulation, and (3) the R&D community, so they can address the technical and infrastructure issues that prevent analysts from executing analyses in a practical, timely, and quality manner.

97 MATHEMATICS AND COMPUTING↗

In-Situ MVA of CO 2 Sequestration Using Smart Field Technology

Capability of underground carbon dioxide storage to confine and sustain injected CO 2 for a long period of time is the main concern for geologic CO 2 sequestration. If a leakage from a geological CO 2 sequestration site occurs, it is crucial to find the approximate amount and the location of the leak, in a timely manner, in order to implement proper remediation activities. An overwhelming majority of research and development for storage site monitoring has been concentrated on atmospheric, surface or near surface monitoring of the sequestered CO 2 . This study aims to monitor the integrity of CO 2 storage at the reservoir level. This work proposes developing in-situ CO 2 Monitoring and Verification technology based on the implementation of Permanent Down-hole Gauges (PDG) or “Smart Wells” along with Artificial Intelligence and Data Mining (AI&DM). The technology attempts to identify the characteristics of the CO 2 leakage by de-convolving the pressure signals collected from Permanent Down-hole Gauges (PDG). Citronelle field, a saline aquifer reservoir, located in the U.S. was considered as the basis for this study. A reservoir simulation model for CO 2 sequestration in the Citronelle field was developed and history matched. PDGs were installed, and therefore were considered in the numerical model, at the injection well and an observation well. Upon completion of the history matching process, high frequency pressure data from PDGs were generated using the history matched numerical model using different CO 2 leakage scenarios. Since pressure signal behaviors were too complicated to de-convolute using any existing mathematical formulations, a Machine Learning-based technology was introduced for this purpose. An Intelligent Leakage Detection System (ILDS) was developed as the result of this effort using the machine learning and pattern recognition technologies. The ILDS is able to detect leakage characteristics in a short period of time (less than a day from its occurrence) demonstrating the capability of the system in quantifying leakage characteristics subject to complex rate behaviors. The performance of ILDS is examined under different conditions such as multiple well leakages, cap rock leakage, availability of an additional monitoring well, presence of pressure drift and noise in the pressure sensor and uncertainty in the reservoir model.

54 ENVIRONMENTAL SCIENCES↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SAM Co-Development to Support Fluoride-salt-cooled High-temperature Reactor Design and Licensing (CRADA 2018-18177 Final Report)

This project aims to raise the SAM code's technical and commercial maturity level to enable the Kairos Power ("Kairos") to use SAM to support its KP-FHR design analysis and licensing application. Argonne National Laboratory ("Argonne") has actively developed and maintained SAM, a modern system-level analysis tool for advanced nonlight water reactors safety analysis. Kairos is currently actively pursuing development of an FHR design and associated technology, and consequently requires a pedigreed safety analysis tool. The purpose of this project is to increase the maturity of the SAM code for the modeling and simulation of the KP-FHR design, thus enabling its use in safety analyses that support licensing application. Argonne will primarily be responsible for software design, development, and testing; while Kairos will be responsible for software requirements, assessment of software capabilities, needs, gaps, and priorities, and development of proprietary models. The research and development activities for the joint SAM development project include: a series of identification and prioritization studies on design characteristics, event sequences, relevant phenomena, and software capabilities; SAM capability enhancements for specific KP-FHR systems and components; performing code verification and validations; integrating uncertainty quantification (UQ), model calibration, and sensitivity analysis (SA) techniques in safety analyses; and raising the software quality rigor level for commercial-grade applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ExacTrac Snap Verification: A New Tool for Ensuring Quality Control for Lung Stereotactic Body Radiation Therapy

Purpose: The intrafraction verification provided by ExacTrac X-ray 6D Snap Verification (ET-SV) allows the tracking of potential isocenter displacements throughout patient position and treatment. The aims of this study were (1) to measure the intrafraction variations of the isocenter position (random errors); (2) to study the amplitude of the variation related to the fraction duration; and (3) to assess the impact of the table movement on positioning uncertainties. Methods and Materials: ET-SV uses images acquired before or during treatment delivery or both to detect isocenter displacement. Twenty patients treated with stereotactic body radiation therapy (SBRT) for lung tumors underwent SV before or during each beam. Noncoplanar beams were sometimes necessary. The time between the setup of the patient and each SV was noted, and values of deviations were compiled for 3 SV time groups: SV performed at {<=}10 min (group 1), between 11 and 20 min (group 2), and {>=}21 min (group 3). Random errors in positioning during the use of noncoplanar fields were noted. Results: The mean isocenter deviation {+-}SD was 2 {+-} 0.5 mm (range, 1-8 mm). The average deviations {+-}SD increased significantly from 1.6 {+-} 0.5 mm to 2.1 {+-} 0.8 mm and 2.2 {+-} 0.6 mm for groups 1, 2, and 3 (P=.002), respectively. Percentages of deviation {>=}3 mm were 7.06%, 22.83%, and 28.07% and 1.08%, 4.15%, and 8.4% for {>=}5 mm (P<.0001). For 11 patients, table rotation was necessary. The mean isocenter deviation {+-}SD increased significantly from 1.9 {+-} 0.5 mm before table rotation to 2.7 {+-} 0.5 mm (P=.001) for the first beam treated after rotation. Conclusions: SV detects isocenter deviations, which increase in amplitude and frequency with the fraction duration, and enables intrafraction verification for SBRT (taking into account clinical condition and technical issues). SV gives accurate targeting at any time during irradiation and may raise confidence to escalate the dose. SV appears to be an important tool for ensuring the quality control of SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of the multigroup cross section library for the CASL neutronics simulator MPACT: Verification

The MPACT neutronics module of the Consortium for Advanced Simulation of Light Water Reactors (CASL) core simulator is a 3D whole core transport code being developed for the CASL toolset, known as the Virtual Environment for Reactor Analysis (VERA). Key characteristics of the MPACT code include a subgroup method for resonance self-shielding and a whole-core transport solver with a 2D/1D synthesis method. Depletion capability is supported by coupling SCALE-ORIGEN with MPACT. A new ENDF/B-VII.1 MPACT 51-group library has been developed by using the AMPX/SCALE and CASL-XSTools code packages based on the procedure introduced in the companion paper, “Development of the Multigroup Cross Section Library for the CASL Neutronics Simulator MPACT: Method and Procedure.” The cross section library generation procedure, cross section library, and MPACT transport capability have been verified by performing various benchmark calculations and comparing the benchmark results to the continuous-energy (CE) Monte Carlo results. Furthermore, the code-to-code comparison for the benchmarks shows that the CASL neutronics simulator MPACT and its 51-group library are working reasonably.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Fluid Dynamics Uncertainty Quantification Challenge Problem: XFOIL vs. MFOIL

Uncertainty quantification (UQ) has become more critical in aerospace engineering due to the growing dependence on computational tools for design optimization and performance analyses of aerospace vehicles. Even though the significance of UQ in assessing the credibility of computational analyses is well recognized, its costs and complexity impede its integration into standard practices, particularly in computational fluid dynamics (CFD) and other fluid analyses. This paper presents a UQ study for low-fidelity computational aerodynamics analyses with XFOIL and mfoil (i.e., the MATLAB version of XFOIL with several implementation modifications); these tools are utilized widely in both research and education. The main contributions of this paper are as follows: 1) improved precision in quantifying the uncertainty of the baseline Monte Carlo results used to benchmark surrogate modeling techniques for UQ, 2) quantification of the effect of the implementation differences between XFOIL and mfoil on solution quantities of interest (QoIs), such as lift and pitching moment coefficients, and 3) development of an open-source UQ library for use with XFOIL and mfoil, which has educational values and helps promote UQ for fluid analyses with aerospace applications. Results and discussions revolve around cases 1-4 of the challenge problem posed by the AIAA Fluid Dynamics Technical Committee’s Uncertainty Quantification Discussion Group (UQDG). In case 3, this work employs CFDverify, an open-source solution verification software, to quantify the discretization error and evaluate the extrapolated QoIs based on the grid convergence index (GCI). This UQ study differentiates itself from previous studies in the rigor of handling baseline Monte Carlo uncertainty and in including mfoil, which is a more accessible alternative to XFOIL. Finally, despite the growing computing power, low-fidelity computational tools remain valuable, such as for aerodynamic shape optimization at Mach numbers below 0.65 and low-to-mid Reynolds numbers.

Lay, Aidan S [University of Tennessee, Knoxville (↗

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were −0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and −0.4 ± 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-209: Verification of 3D Surface Registration Between Stereograms and CT Images

Purpose: Stereography can provide a visualization of the skin surface for radiation therapy patients. The aim of this study was to verify the registration algorithm in a commercial image analysis software, 3dMDVultus, for the fusion of stereograms and CT images. Methods: CT and stereographic scans were acquired of a head phantom and a deformable phantom. CT images were imported in 3dMDVultus and the surface contours were generated by threshold segmentation. Stereograms were reconstructed in 3dMDVultus. The resulting surfaces were registered with Vultus algorithm and then exported to in-house registration software and compared with four algorithms: rigid, affine, non-rigid iterative closest point (ICP) and b-spline algorithm. RMS (root-mean-square residuals of the surface point distances) error between the registered CT and stereogram surfaces was calculated and analyzed. Results: For the head phantom, the maximum RMS error between registered CT surfaces to stereogram was 6.6 mm for Vultus algorithm, whereas the mean RMS error was 0.7 mm. For the deformable phantom, the maximum RMS error was 16.2 mm for Vultus algorithm, whereas the mean RMS error was 4.4 mm. Non-rigid ICP demonstrated the best registration accuracy, as the mean of RMS errors were both within 1 mm. Conclusion: The accuracy of registration algorithm in 3dMDVultus was verified and exceeded RMS of 2 mm for deformable cases. Non-rigid ICP and b-spline algorithms improve the registration accuracy for both phantoms, especially in deformable one. For those patients whose body habitus deforms during radiation therapy, more advanced nonrigid algorithms need to be used.

60 APPLIED LIFE SCIENCES↗

SU-E-J-22: A Feasibility Study On KV-Based Whole Breast Radiation Patient Setup

Purpose: In room kilovoltage x-ray (kV) imaging provides higher contrast than Megavoltage (MV) imaging with faster acquisition time compared with on-board cone-beam computed tomography (CBCT), thus improving patient setup accuracy and efficiency. In this study we evaluated the clinical feasibility of utilizing kV imaging for whole breast radiation patient setup. Methods: For six breast cancer patients with whole breast treatment plans using two opposed tangential fields, MV-based patient setup was conducted by aligning patient markers with in room lasers and MV portal images. Beam-eye viewed kV images were acquired using Varian OBI system after the set up process. In house software was developed to transfer MLC blocks information overlaying onto kV images to demonstrate the field shape for verification. KV-based patient digital shift was derived by performing rigid registration between kV image and the digitally reconstructed radiography (DRR) to align the bony structure. This digital shift between kV-based and MV-based setup was defined as setup deviation. Results: Six sets of kV images were acquired for breast patients. The mean setup deviation was 2.3mm, 2.2mm and 1.8mm for anterior-posterior, superior-inferior and left-right direction respectively. The average setup deviation magnitude was 4.3±1.7mm for six patients. Patient with large breast had a larger setup deviation (4.4–6.2mm). There was no strong correlation between MV-based shift and setup deviation. Conclusion: A preliminary clinical workflow for kV-based whole breast radiation setup was established and tested. We observed setup deviation of the magnitude below than 5mm. With the benefit of providing higher contrast and MLC block overlaid on the images for treatment field verification, it is feasible to use kV imaging for breast patient setup.

60 APPLIED LIFE SCIENCES↗

Automated Installation Verification of COMSOL via LiveLink for MATLAB

Verifying that a local software installation performs as the developer intends is a potentially time-consuming but necessary step for nuclear safety-related codes. Automating this process not only saves time, but can increase reliability and scope of verification compared to ‘hand’ comparisons. While COMSOL does not include automatic installation verification as many commercial codes do, it does provide tools such as LiveLink™ for MATLAB® and the COMSOL API for use with Java® through which the user can automate the process. Here we present a successful automated verification example of a local COMSOL 5.0 installation for nuclear safety-related calculations at the Oak Ridge National Laboratory’s High Flux Isotope Reactor (HFIR).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation, capabilities, and benchmarking of Shift, a massively parallel Monte Carlo radiation transport code

This paper discusses the implementation, capabilities, and validation of Shift, a massively parallel Monte Carlo radiation transport package developed and maintained at Oak Ridge National Laboratory. It has been developed to scale well from laptop to small computing clusters to advanced supercomputers. Special features of Shift include hybrid capabilities for variance reduction such as CADIS and FW-CADIS, and advanced parallel decomposition and tally methods optimized for scalability on supercomputing architectures. Shift has been validated and verified against various reactor physics benchmarks and compares well to other state-of-the-art Monte Carlo radiation transport codes such as MCNP5, CE KENO-VI, and OpenMC. Some specific benchmarks used for verification and validation include the CASL VERA criticality test suite and several Westinghouse AP1000 ® problems. These benchmark and scaling studies show promising results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗