Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

High-temperature microphone system

Pressure fluctuations in air or other gases in an area of elevated temperature are measured using a condenser microphone located in the area of elevated temperature and electronics for processing changes in the microphone capacitance located outside the area the area and connected to the microphone by means of high-temperature cable assembly. The microphone includes apparatus for decreasing the undesirable change in microphone sensitivity at high temperatures. The high temperature cable assembly operates as a half-wavelength transmission line in an AM carrier system and maintains a large temperature gradient between the two ends of the cable assembly. The processing electronics utilizes a voltage controlled oscillator for automatic tuning thereby increasing the sensitivity of the measuring apparatus.

Zuckerwar, A. J.↗

Fiberoptics technology and its application to propulsion control systems

Current work on optical sensors and optically controlled actuators for use in air-breathing engine control systems is reviewed with particular reference to the design and operation of several new fiber-optic devices. These include a tachometer, a rotary position encoder, a Fabry-Perot interferometer and a rare-earth sensor for measuring engine gas temperatures, a high-temperature photoswitch designed for the range -55 to 260 C, and optical cables and connectors. The advantages of optics over conventional wire systems used for sensing and actuator control are briefly discussed.

Baumbick, R. J.↗

Materials Challenges and Experimental Approaches to Understanding Long-Term Materials Behavior for Extended Nuclear Plant Operations

Commercial nuclear reactors present a very challenging environment for materials to operate within. Materials undergo combinations of environmental stressors that include high temperatures, contact with water, high stress loading, fatigue, and intense radiation fields. Over twenty five different metal alloys can be found within the primary and secondary systems along with numerous types of materials present in the containment vessel, concrete structures, instrumentation and control equipment, cabling, buried piping, and other support facilities. Dominant forms of degradation may vary greatly between the different systems, structures and components. Understanding materials degradation is necessary for informed long-term operation decisions that establish materials limits, support focused planning of materials inspections, provide economic and safety based decisions on component replacement, and allow for more appropriate regulatory guidelines. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NEMA wire and cable standards development programs

The National Electrical Manufacturers Association (NEMA) is the nation's largest trade association for manufacturers of electrical equipment. Its member companies produce components, end-use equipment and systems for the generation, transmission, distribution, control and use of electricity. The wire and cable division is presented in 6 sections: building wire and cable, fabricated conductors, flexible cords, high performance wire and cable, magnet wire, and power and control cable. Participating companies are listed.

Baird, Robert W.↗

Cascaded resonant bridge converters

A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

Stuart, Thomas A.↗

Apparatus and method for detecting tampering in flexible structures

A system for monitoring or detecting tampering in a flexible structure includes taking electrical measurements on a sensing cable coupled to the structure, performing spectral analysis on the measured data, and comparing the spectral characteristics of the event to those of known benign and/or known suspicious events. A threshold or trigger value may used to identify an event of interest and initiate data collection. Alternatively, the system may be triggered at preset intervals, triggered manually, or triggered by a signal from another sensing device such as a motion detector. The system may be used to monitor electrical cables and conduits, hoses and flexible ducts, fences and other perimeter control devices, structural cables, flexible fabrics, and other flexible structures.

47 OTHER INSTRUMENTATION↗

Signal Generator Compensates For Phase Shift In Cable

Stabilized reference signal delivered to remote unit. Signals at two different frequencies transmitted back and forth along cable and mixed to measure propagation delay in cable. Delay-measuring circuitry part of feedback loop constraining overall delay at stable value. Intended for use in system generating precise time and frequency signals, signal-generating subsystem compensates for phase shift in cable.

Sigman, E. H.↗

Potential Environmental Effects of Marine Renewable Energy Development—The State of the Science

Marine renewable energy (MRE) harnesses energy from the ocean and provides a low-carbon sustainable energy source for national grids and remote uses. The international MRE industry is in the early stages of development, focused largely on tidal and riverine turbines, and wave energy converters (WECs), to harness energy from tides, rivers, and waves, respectively. Although MRE supports climate change mitigation, there are concerns that MRE devices and systems could affect portions of the marine and river environments. The greatest concern for tidal and river turbines is the potential for animals to be injured or killed by collision with rotating blades. Other risks associated with MRE device operation include the potential for turbines and WECs to cause disruption from underwater noise emissions, generation of electromagnetic fields, changes in benthic and pelagic habitats, changes in oceanographic processes, and entanglement of large marine animals. The accumulated knowledge of interactions of MRE devices with animals and habitats to date is summarized here, along with a discussion of preferred management methods for encouraging MRE development in an environmentally responsible manner. As there are few devices in the water, understanding is gained largely from examining one to three MRE devices. This information indicates that there will be no significant effects on marine animals and habitats due to underwater noise from MRE devices or emissions of electromagnetic fields from cables, nor changes in benthic and pelagic habitats, or oceanographic systems. Ongoing research to understand potential collision risk of animals with turbine blades still shows significant uncertainty. There has been no significant field research undertaken on entanglement of large animals with mooring lines and cables associated with MRE devices.

16 TIDAL AND WAVE POWER↗

Emergency Locator Transmitter System Performance During Three Full-Scale General Aviation Crash Tests

Full-scale crash tests were conducted on three Cessna 172 aircraft at NASA Langley Research Center's Landing and Impact Research facility during the summer of 2015. The purpose of the three tests was to evaluate the performance of commercially available Emergency Locator Transmitter (ELT) systems and support development of enhanced installation guidance. ELTs are used to provide location information to Search and Rescue (SAR) organizations in the event of an aviation distress situation, such as a crash. The crash tests simulated three differing severe but survivable crash conditions, in which it is expected that the onboard occupants have a reasonable chance of surviving the accident and would require assistance from SAR personnel. The first simulated an emergency landing onto a rigid surface, while the second and third simulated controlled flight into terrain. Multiple ELT systems were installed on each airplane according to federal regulations. The majority of the ELT systems performed nominally. In the systems which did not activate, post-test disassembly and inspection offered guidance for non-activation cause in some cases, while in others, no specific cause could be found. In a subset of installations purposely disregarding best practice guidelines, failure of the ELT-to-antenna cabling connections were found. Recommendations for enhanced installation guidance of ELT systems will be made to the Radio Technical Commission for Aeronautics (RTCA) Special Committee 229 for consideration for adoption in a future release of ELT minimum operational performance specifications. These recommendations will be based on the data gathered during this test series as well as a larger series of crash simulations using computer models that will be calibrated based on these data

Littell, Justin D.↗

Lunar surface vehicle model competition

During Fall and Winter quarters, Georgia Tech's School of Mechanical Engineering students designed machines and devices related to Lunar Base construction tasks. These include joint projects with Textile Engineering students. Topics studied included lunar environment simulator via drop tower technology, lunar rated fasteners, lunar habitat shelter, design of a lunar surface trenching machine, lunar support system, lunar worksite illumination (daytime), lunar regolith bagging system, sunlight diffusing tent for lunar worksite, service apparatus for lunar launch vehicles, lunar communication/power cables and teleoperated deployment machine, lunar regolith bag collection and emplacement device, soil stabilization mat for lunar launch/landing site, lunar rated fastening systems for robotic implementation, lunar surface cable/conduit and automated deployment system, lunar regolith bagging system, and lunar rated fasteners and fastening systems. A special topics team of five Spring quarter students designed and constructed a remotely controlled crane implement for the SKITTER model.

Source record↗

Human Stability While Exercising on a VIS Device in Zero Gravity

BACKGROUND: A Vibration Isolation and Stabilization (VIS) system is being designed for use with the European Enhanced Exploration Exercise Device (E4D) [1]. The exercise bar is attached to cables that extend and retract through openings in the E4D platform, which the subject stands on while exercising. Since the E4D is mounted on a moving VIS device, the whole system moves under the subject’s feet. While tension in the cables does help stabilize a crew member in 0g by bracing him or her against the moving platform, flexible cables do not offer full support against falling. This raises the question of whether various exercises that are successfully performed in 1g on a stationary device can be performed without losing balance in 0g on a moving device. Quantifying stability conditions and establishing stability requirements for exercise countermeasure systems is a long-standing challenge and this work helped to inform this specific need for integrated E4D/VIS flight project development. METHODS AND RESULTS: A simplified stability analysis can be attempted based on platform accelerations generated by the VIS device simulation. In this type of analysis, the subject is conceived as standing on the platform in 0g while being held down to it by the tension in the cables. If the sideways acceleration of the platform is such that the cables cannot generate a sufficient moment relative to, e.g., the heels or the toes of the subject to overcome the tipping moment from the inertial forces on the accelerated subject’s body, the subject becomes unstable. This approach, which we refer to as the ‘static’ approximation, indicated failure of all the exercises that were considered in the comprehensive VIS analysis of the E4D. It was realized, however, that platform accelerations are not externally imposed but are themselves induced by the motion of the subject’s body during exercise, and a model calculation confirmed that this drastically altered the tipping moment on the subject, with the potential to even switch the direction in which the body would tip over. This made it imperative to consider in a coupled manner both the motion of the exercising subject’s body and the induced VIS platform motion while considering stability. The coupled dynamics requirement was met by the VIS simulation incorporating time-dependent human mass properties atop the platform and driven by the inertial forces from the prescribed subject motion relative to the platform based on motion-capture recorded human trajectories in 1g on a stationary E4D [2]. To analyze simulation results, a stability criterion was also needed. We do not know how to account for the human ‘control system’ that would take visual and vestibular cues as inputs as the platform moves in 0g. We thus chose to follow an approach we had previously used to analyze the dynamic feasibility of performing a task in lunar gravity along the human body trajectory recorded in 1g [3]. In this approach, one analyzes the center of pressure (COP) between the shoes and the ground (or platform) and checks if the COP remains within the convex hull of the footprints on the ground (or platform), commonly referred to as base of support (BOS). Since pressure is vertical and, in the absence of foot restraints, positive, the COP going outside the BOS indicates that the trajectory recorded in 1g is not dynamically feasible in microgravity and/or on the moving platform of the device. The outcome of the COP-based analysis was that some of the key exercises, especially the deadlift and the back squat exercises, were found to be dynamically feasible for at least some number of the exercise cycles, this number increasing with the cable tension. While this type of stability analysis does not account for the likely alteration of the exercise trajectory from its 1g form in space, it does show that there exist at least some realistic trajectories that pass the dynamic feasibility criterion. This adds confidence that, with further adjustment by the subject of the exercise form in 0g on a moving device, a number of exercises can be performed without losing balance.

D Frenkel↗

High voltage testing for the Majorana Demonstrator

The Majorana Collaboration is constructing theMajorana Demonstrator, an ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to search for neutrinoless double-beta decay in 76Ge. The phenomenon of surface micro-discharge induced by high-voltage has been studied in the context of theMajorana Demonstrator. This effect can damage the front-end electronics or mimic detector signals. To ensure the correct performance, every high-voltage cable and feedthrough must be capable of supplying HPGe detector operating voltages as high as 5 kV without exhibiting discharge. R&D measurements were carried out to understand the testing system and determine the optimum design configuration of the high-voltage path, including different improvements of the cable layout and feedthrough flange model selection. Every cable and feedthrough to be used at the Majorana Demonstrator was characterized and the micro-discharge effects during theMajorana Demonstrator commissioning phase were studied. A stable configuration has been achieved, and the cables and connectors can supply HPGe detector operating voltages without exhibiting discharge.

high-voltage↗

Diagnostic components in harsh radiation environments: Possible overlap in R and D requirements of inertial confinement and magnetic fusion systems

The next generation of large scale fusion devices--ITER/LMJ/NIF--will require diagnostic components to operate in environments far more severe than those encountered in present facilities. This harsh environment is the result of high fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiation, and in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced in today's devices. The similarities and dissimilarities between environmental effects on diagnostic components for the inertial confinement and magnetic confinement fusion fields have been assessed. Areas in which considerable overlap have been identified are optical transmission materials and optical fibers in particular, neutron detection systems and electronics needs. Although both fields extensively use cables in the hostile environment, there is little overlap because the environments and requirements are very different.

36 MATERIALS SCIENCE↗

Final design of thermal diagnostic system in SPIDER ion source

The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H{sup −} production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

ARM Airborne Continuous carbon dioxide measurements

The heart of the AOS CO2 Airborne Rack Mounted Analyzer System is the AOS Manifold. The AOS Manifold is a nickel coated aluminum analyzer and gas processor designed around two identical nickel-plated gas cells, one for reference gas and one for sample gas. The sample and reference cells are uniquely designed to provide optimal flushing efficiency. These cells are situated between a black-body radiation source and a photo-diode detection system. The AOS manifold also houses flow meters, pressure sensors and control valves. The exhaust from the analyzer flows into a buffer volume which allows for precise pressure control of the analyzer. The final piece of the analyzer is the demodulator board which is used to convert the DC signal generated by the analyzer into an AC response. The resulting output from the demodulator board is an averaged count of CO2 over a specified hertz cycle reported in volts and a corresponding temperature reading. The system computer is responsible for the input of commands and therefore works to control the unit functions such as flow rate, pressure, and valve control.The remainder of the system consists of compressors, reference gases, air drier, electrical cables, and the necessary connecting plumbing to provide a dry sample air stream and reference air streams to the AOS manifold.

54 ENVIRONMENTAL SCIENCES↗

Proposed technique for vertical alignment of a crane's cable

Proposed vertical alignment technique senses the attitude of a cranes cable and displays any deviation from the vertical. The system consists of a detector assembly fixed to the boom and a display scope located in the cabin. It has potential application with either fixed-boom cranes or gantries.

Gera, J., Jr.↗