Search NASA⌕ Search

SEARCH · Search NASA

Results for “cell integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

First of Their Kind: Solar Cells with a Dry-Processed Perovskite Absorber Layer via Powder Aerosol Deposition and Hot-Pressing

Preparing halide perovskite films by solvent-free, powder-based processing approaches currently attracts more and more attention. However, working solar cells employing dry, powder-based halide perovskite thin films, have not been demonstrated so far. Herein, perovskite solar cells are presented where the absorber layer is prepared by transferring readily synthesized perovskite powders into a compact thin film using a fully dry-powder-processing concept. Compact thin films are deposited via an optimized powder aerosol deposition (PAD) process. Pressing at 120 °C further improves the morphology and the optoelectronic film properties. Integrating the perovskite films in a solar cell configuration results in fully working devices, with champion power conversion efficiencies of >6%. While the (optoelectronic) properties of the PAD-processed films are found to be comparable with their solution-processed counterparts, investigations of the solar cell stack suggest deterioration of the electron-transport layer properties due to the PAD process, and the presence of hydrates at the perovskite surface to be important factors that contribute to the limited solar cell efficiency. Herein, perspectives to overcome the identified limitations are outlined, emphasizing the high potential and realizability of efficient perovskite solar cells based on dry-powder-processing approaches in the future.

14 SOLAR ENERGY↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Parallel Processor Array for Optimum Path Planning

The invention computes the optimum path across a terrain or topology represented by an array of parallel processor cells interconnected between neighboring cells by links extending along different directions to the neighboring cells. Such an array is preferably implemented as a high-speed integrated circuit. The computation of the optimum path is accomplished by, in each cell, receiving stimulus signals from neighboring cells along corresponding directions, determining and storing the identity of a direction along which the first stimulus signal is received, broadcasting a subsequent stimulus signal to the neighboring cells after a predetermined delay time, whereby stimulus signals propagate throughout the array from a starting one of the cells. After propagation of the stimulus signal throughout the array, a master processor traces back from a selected destination cell to the starting cell along an optimum path of the cells in accordance with the identity of the directions stored in each of the cells.

Kremeny, Sabrina E.↗

Simultaneous inhibition of ATM, ATR, and DNA-PK causes synergistic lethality

Here, in this paper, we report that simultaneous inhibition of the three primary DNA damage recognition PI3 kinase-like kinases (PIKKs) —ATM, ATR, and DNA-PK— induces severe combinatorial synthetic lethality in mammalian cells. Utilizing Chinese hamster cell lines CHO and V79 and their respective PIKK mutants, we evaluated effects of inhibiting these three kinases on cell viability, DNA damage response, and chromosomal integrity. Our results demonstrate that while single or dual kinase inhibition increased cytotoxicity, inhibition of all three PIKKs results in significantly higher synergistic lethality, chromosomal aberrations, and DNA double-strand break (DSB) induction as calculated by their synergy scores. These findings suggest that the overlapping redundancy of ATM, ATR, and DNA-PK functions is critical for cell survival, and their combined inhibition greatly disrupts DNA damage signaling and repair processes, leading to cell death. This study provides insights into the potential of multi-targeted DDR kinase inhibition as an effective anticancer strategy, necessitating further research to elucidate underlying mechanisms and therapeutic applications.

59 BASIC BIOLOGICAL SCIENCES↗

Integral assembly of photovoltaic arrays using glass

For a number of reasons glass is an excellent material for encapsulation of solar cell arrays. Glass can be readily available at relatively low cost. It exhibits excellent stability against degradation by solar ultraviolet illumination and atmospheric pollutants. A superior approach results if glass is employed directly as an integral encapsulant without secondary organic materials. A description is presented of a electrostatic bonding process which is being developed for integral assembly of glass encapsulated arrays. Solar cells are placed in contact with the glass surface, temperature is raised until the glass becomes ionically conductive, and an electric field is applied to initiate the bonding action. Silicon solar cells up to 3 inches in diameter have been integrally bonded without degradation.

Younger, P. R.↗

Li 2 S 6 ‐Integrated PEO‐Based Polymer Electrolytes for All‐Solid‐State Lithium‐Metal Batteries

Abstract The integration of Li 2 S 6 within a poly(ethylene oxide) (PEO)‐based polymer electrolyte is demonstrated to improve the polymer electrolyte's ionic conductivity because the strong interplay between O 2− (PEO) and Li + from Li 2 S 6 reduces the crystalline volume within the PEO. The Li/electrolyte interface is stabilized by the in situ formation of an ultra‐thin Li 2 S/Li 2 S 2 layer via the reaction between Li 2 S 6 and lithium metal, which increases the ionic transport at the interface and suppresses lithium dendrite growth. A symmetric Li/Li cell with the Li 2 S 6 ‐integrated composite electrolyte has excellent cyclability and a high critical current density of 0.9 mA cm −2 at 40 °C. Impressive electrochemical performance is demonstrated with all‐solid‐state Li/LiFePO 4 and high‐voltage Li/LiNi 0.8 Mn 0.1 Co 0.1 O 2 cells at 40 °C.

Fang, Ruyi↗

Li 2 S 6 ‐Integrated PEO‐Based Polymer Electrolytes for All‐Solid‐State Lithium‐Metal Batteries

Abstract The integration of Li 2 S 6 within a poly(ethylene oxide) (PEO)‐based polymer electrolyte is demonstrated to improve the polymer electrolyte's ionic conductivity because the strong interplay between O 2− (PEO) and Li + from Li 2 S 6 reduces the crystalline volume within the PEO. The Li/electrolyte interface is stabilized by the in situ formation of an ultra‐thin Li 2 S/Li 2 S 2 layer via the reaction between Li 2 S 6 and lithium metal, which increases the ionic transport at the interface and suppresses lithium dendrite growth. A symmetric Li/Li cell with the Li 2 S 6 ‐integrated composite electrolyte has excellent cyclability and a high critical current density of 0.9 mA cm −2 at 40 °C. Impressive electrochemical performance is demonstrated with all‐solid‐state Li/LiFePO 4 and high‐voltage Li/LiNi 0.8 Mn 0.1 Co 0.1 O 2 cells at 40 °C.

Fang, Ruyi↗

Brief Overview of the ASD Integrated Test Stand, Activities and Hazards

The ITS venue provides the first opportunity to fully assemble and test the performance of the injector; integrate, assemble and test four modules; measure the severity of the Beam Break-Up instability and perform the first set of beam measurements. Figure 1 shows a high level configuration of the ITS without the system of overhead cable management trays. The final configuration will integrate the injector, 4 modules (12 accelerator cells), 264 SSPP Line Replaceable Units (LRUs), global controls, data acquisition, and a subset of the downstream transport, Table 1. This was chosen because it provides the minimum accelerator cells required to measure the Beam Break-Up (BBU) instability and perform measurements required to validate the ASD beam transport computer models, which are priority measurements for commissioning.

43 PARTICLE ACCELERATORS↗

ARIES / Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems.The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

electrical grid↗

Single Cell RNA-Seq and Machine Learning Reveal Novel Subpopulations in Low-Grade Inflammatory Monocytes With Unique Regulatory Circuits

Subclinical doses of LPS (SD-LPS) are known to cause low-grade inflammatory activation of monocytes, which could lead to inflammatory diseases including atherosclerosis and metabolic syndrome. Sodium 4-phenylbutyrate is a potential therapeutic compound which can reduce the inflammation caused by SD-LPS. To understand the gene regulatory networks of these processes, we have generated scRNA-seq data from mouse monocytes treated with these compounds and identified 11 novel cell clusters. We have developed a machine learning method to integrate scRNA-seq, ATAC-seq, and binding motifs to characterize gene regulatory networks underlying these cell clusters. Using guided regularized random forest and feature selection, our method achieved high performance and outperformed a traditional enrichment-based method in selecting candidate regulatory genes. Our method is particularly efficient in selecting a few candidate genes to explain observed expression pattern. In particular, among 531 candidate TFs, our method achieves an auROC of 0.961 with only 10 motifs. Finally, we found two novel subpopulations of monocyte cells in response to SD-LPS and we confirmed our analysis using independent flow cytometry experiments. Our results suggest that our new machine learning method can select candidate regulatory genes as potential targets for developing new therapeutics against low grade inflammation.

60 APPLIED LIFE SCIENCES↗

Degradation of Commercial Lithium-Ion Cells as a Function of Chemistry and Cycling Conditions

Energy storage systems with Li-ion batteries are increasingly deployed to maintain a robust and resilient grid and facilitate the integration of renewable energy resources. However, appropriate selection of cells for different applications is difficult due to limited public data comparing the most commonly used off-the-shelf Li-ion chemistries under the same operating conditions. This article details a multi-year cycling study of commercial LiFePO 4 (LFP), LiNi x Co y Al 1–x–y O 2 (NCA), and LiNi x Mn y Co 1–x–y O 2 (NMC) cells, varying the discharge rate, depth of discharge (DOD), and environment temperature. The capacity and discharge energy retention, as well as the round-trip efficiency, were compared. Even when operated within manufacturer specifications, the range of cycling conditions had a profound effect on cell degradation, with time to reach 80% capacity varying by thousands of hours and cycle counts among cells of each chemistry. The degradation of cells in this study was compared to that of similar cells in previous studies to identify universal trends and to provide a standard deviation for performance. All cycling files have been made publicly available at batteryarchive.org, a recently developed repository for visualization and comparison of battery data, to facilitate future experimental and modeling efforts.

25 ENERGY STORAGE↗

Coal-Based Fuel-Cell Powerplants

Report assesses advanced technologyy design alternatives for integrated coal-gasifier/fuel-cell powerplants. Various gasifier, cleanup, and fuelcell options evaluated. Evaluation includes adjustments to assumed performances and costs of proposed technologies where required. Analysis identifies uncertainties remaining in designs and most promising alternatives and research and development required to develop these technologies. Bulk of report summary and detailed analysis of six major conceptual designs and variations of each. All designs for plant that uses Illinois No. 6 coal and produces 675 MW of net power.

Ferral, J. F.↗

Reverse bias protected solar array with integrated bypass battery

A method for protecting the photovoltaic cells in a photovoltaic (PV) array from reverse bias damage by utilizing a rechargeable battery for bypassing current from a shaded photovoltaic cell or group of cells, avoiding the need for a bypass diode. Further, the method mitigates the voltage degradation of a PV array caused by shaded cells.

Landis, Geoffrey A↗

Unitized Regenerative Fuel Cell System Gas Storage-Radiator Development

High-energy-density regenerative fuel cell systems that are used for energy storage require novel approaches to integrating components in order to preserve mass and volume. A lightweight unitized regenerative fuel cell (URFC) energy storage system concept is being developed at the NASA Glenn Research Center. This URFC system minimizes mass by using the surface area of the hydrogen and oxygen storage tanks as radiating heat surfaces for overall thermal control of the system. The waste heat generated by the URFC stack during charging and discharging is transferred from the cell stack to the surface of each tank by loop heat pipes, which are coiled around each tank and covered with a thin layer of thermally conductive carbon composite. The thin layer of carbon composite acts as a fin structure that spreads the heat away from the heat pipe and across the entire tank surface. Two different-sized commercial-grade composite tanks were constructed with integral heat pipes and tested in a thermal vacuum chamber to examine the feasibility of using the storage tanks as system radiators. The storage tank-radiators were subjected to different steady-state heat loads and varying heat load profiles. The surface emissivity and specific heat capacity of each tank were calculated. In the future, the results will be incorporated into a model that simulates the performance of similar radiators using lightweight, spacerated carbon composite tanks.

Burke, Kenneth A.↗

Internal short circuit and failure mechanisms of lithium-ion pouch cells under mechanical indentation abuse conditions: An experimental study

Electromechanical structural integrity and thermal stability dictate the safety performance of lithium-ion batteries. Progressive deformation and failure across microscopic and macroscopic lengths scales that are responsible for internal short circuit (ISC) in lithium-ion cells under mechanical abuse conditions remains elusive. In this study, a series of indentation tests were conducted on lithium-ion cells with different capacities up to the occurrence of ISC. The external response and internal configuration of these cells were investigated. It is discovered that cells with different capacities and state of charges exhibited different behaviors. Maximum temperature, which is often regarded as the most important parameter related to thermal runaway (TR), varied considerably due to the complicated contact configurations. X-ray computed tomography (XCT) showed that ISC was a collective result of shear band or other strain-localization modes in the electrode assembly, shear offsets in the granular coatings of electrodes, and the accompanying ductile fracture in the metal foils. We believe that the irregular strain-localization modes (kinks, cusps, and buckles), radical mismatches in mechanical properties of different layers, and geometric features of the indenter eventually lead to the tearing/puncture of cell separator at various locations. Furthermore, the results could provide useful guidance for the micromechanical modeling of lithium-ion cells.

25 ENERGY STORAGE↗

Processing technology for high efficiency silicon solar cells

Recent advances in silicon solar cell processing have led to attainment of conversion efficiency approaching 20%. The basic cell design is investigated and features of greatest importance to achievement of 20% efficiency are indicated. Experiments to separately optimize high efficiency design features in test structures are discussed. The integration of these features in a high efficiency cell is examined. Ion implantation has been used to achieve optimal concentrations of emitter dopant and junction depth. The optimization reflects the trade-off between high sheet conductivity, necessary for high fill factor, and heavy doping effects, which must be minimized for high open circuit voltage. A second important aspect of the design experiments is the development of a passivation process to minimize front surface recombination velocity. The manner in which a thin SiO2 layer may be used for this purpose is indicated without increasing reflection losses, if the antireflection coating is properly designed. Details are presented of processing intended to reduce recombination at the contact/Si interface. Data on cell performance (including CZ and ribbon) and analysis of loss mechanisms are also presented.

Spitzer, M. B.↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

Experiments on technology mapping using different cell libraries

Technology mapping is one of the major steps in the synthesis process of integrated circuits. Efficient algorithms have been proposed in the recent past to optimize the number of cells required to implement a given design, but not enough effort has been spent in studying the relationship between the quality of the circuit produced by the logic synthesis tool and the cell library used to perform the mapping. In this paper we present experiments on technology mapping that show how the design of the cell library can influence the area and the delay of the synthesized circuit.

Macii, Enrico↗