Search NASA⌕ Search

SEARCH · Search NASA

Results for “cleaning methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Integrity Assessment of Hanford 242-A Evaporator Facility E-A-1 Re-boiler Vessel via Fluorescein Liquid Tracer Test Methods - 17357

The 242-A Evaporator Facility is critical to the United States Department of Energy's (DOE) Hanford Site clean-up mission due to limited space within the existing Double-Shell Tanks (DSTs) used to store nuclear and chemical waste until future processing. The 242-A Evaporator Facility is currently the sole waste volume reduction process used at Hanford, and the E-A-1 Re-boiler is essential to the Evaporator process. Due to the potential for cross-contamination between the Re-boiler tubes through which waste passes and the tube sheets of uncontaminated steam, an assessment of the Re-boiler vessel's integrity is required for continuing operations of the facility. In order to meet these requirements, an independent integrity assessment was designed to use fluorescein liquid tracer (LT) to verify the leak-tightness of the Re-boiler vessel in accordance with Washington River Protection Solutions, LLC (WRPS) tightness test standards, as well as, the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 1, NB-6300. LT test methodologies were evaluated and determined to be appropriate for a vessel with restricted access, such as the E-A-1 Re-boiler, as it provided the needed sensitivity, reliability, and cost; as well as, exceeded the leak-tightness specifications required by both WRPS and ASME B and PV Code standards. The integrity test requires water laced with fluorescein be circulated through the waste processing loop of the 242-A Evaporator and samples of steam condensate be collected and analyzed for traces of fluorescein to determine leak-tightness. Liquid condensate sampling was conducted prior to and during testing and the samples were analyzed for fluorescein tracer to determine the amount of fluorescein that flowed out of the tubes of the Re-boiler into the steam side of the vessel. Given the established criteria for 'leak-tight,' test results determined that the Re-boiler passed the integrity assessment. After further scrutiny of the 2014 test and data results, it was determined that although the Re-boiler was 'leak-tight,' as established by the test criteria, there was concern of future leakage. The DOE and the DOE Office of River Protection (ORP) requested that WRPS repeat the integrity assessment in two and a half years to determine if the potential leak was growing, which could threaten continuing operations of the 242-A Evaporator. The 2017 test has been redesigned using lessons learned from the 2014 test and was modified to account for ergonomic and safety considerations, ease of repeatability, and accuracy of results. The liquid tracer methodology and test plan developed for the Re-boiler will continue to be implemented in 5 year increments to monitor current and future integrity. The method may also prove useful for other aging components across the Hanford Site, where appropriate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements.

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Hydrogen Peroxide as a Method for Bioburden Reduction in Facilities with Strict Materials Requirements

The cleanrooms used to curate NASA’s Astromaterials samples are carefully monitored for particulate and inorganic contamination. The clean labs also have a very limited set of acceptable materials and cleaning agents to further minimize the potential for contamination. Labs are cleaned primarily with isopropyl alcohol. Astromaterials samples are handled with tools made of stainless steel (304 or 316), Teflon, or aluminum alloy (6061). Although our current collections are not particularly susceptible to biological alteration or organic contamination, this will not be the case for new collections from the OSIRIS-REx mission, Hayabusa2, and from Mars Sample Return. Therefore, it is necessary to develop and test methods to reduce the bioburden in astromaterials cleanrooms without introducing unwanted contaminants. We will report on the results of three case studies where 7.5 wt% hydrogen peroxide was prepared from a stock solution of ultrapure 30 wt% hydrogen peroxide (JT Baker) using curation-grade ultrapure water. We followed CDC (Center for Disease Control) guidelines for using hydrogen peroxide as a high level disinfectant. This solution was used to clean a glovebox prior to processing Apollo samples, as well as surfaces in the Antarctic meteorite processing lab and Stardust lab after facilities monitoring indicated an unwanted increase in bioburden. In all three instances, the culturable bioburden was significantly reduced after a 30 min. exposure to the 7.5% hydrogen peroxide solution without a corresponding increase in inorganic or organic contamination. We observed 77 to 100% reductions in the bioburden recovery rate. In one case study, we also performed amplicon DNA sequencing on samples collected from the surfaces before and after cleaning. We observed a significant change in microbial community composition after peroxide cleaning. These results suggest that routine cleaning with hydrogen peroxide could be an effective way to control bioburden in astromaterials cleanrooms and other facilities with strict contamination control requirements.

A B Regberg↗

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from Carbon Dioxide

Oxygen recovery from respiratory carbon dioxide is an important aspect of human spaceflight. Methods exist to sequester the carbon dioxide, but production of oxygen needs further development. The current International Space Station Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane which is vented overboard. The Bosch reaction, which converts carbon dioxide to oxygen and solid carbon, is capable of recovering all the oxygen from carbon dioxide, and it is a promising alternative to the Sabatier reaction. However, the last reaction in the cycle, the Boudouard reaction, produces solid carbon, and the resulting carbon buildup eventually fouls the catalyst, reducing reactor life and increasing consumables. To minimize this fouling and increase efficiency, a number of self-cleaning catalyst designs have been created. This paper will describe recent results evaluating one of the designs.

ECLSS↗

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from Carbon Dioxide

Oxygen recovery from respiratory carbon dioxide is an important aspect of human spaceflight. Methods exist to sequester the carbon dioxide, but production of oxygen needs further development. The current International Space Station Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction, which converts carbon dioxide to oxygen and solid carbon is capable of recovering all the oxygen from carbon dioxide, and is the only real alternative to the Sabatier reaction. However, the last reaction in the cycle, the Boudouard reaction, produces solid carbon and the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling and increase efficiency, a number of self-cleaning catalyst designs have been created. This paper will describe recent results evaluating one of the designs.

Oxygen recovery↗

Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from Carbon Dioxide

Oxygen recovery from respiratory carbon dioxide is an important aspect of human spaceflight. Methods exist to sequester the carbon dioxide, but production of oxygen needs further development. The current International Space Station Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50 because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction, which converts carbon dioxide to oxygen and solid carbon is capable of recovering all the oxygen from carbon dioxide, and is the only real alternative to the Sabatier reaction. However, the last reaction in the cycle, the Boudouard reaction, produces solid carbon and the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling and increase efficiency, a number of self-cleaning catalyst designs have been created. This paper will describe recent results evaluating one of the designs.

Oxygen Recovery↗

Acrylic purification and coatings

Radon (Rn) and its decay daughters are a well-known source of background in direct WIMP detection experiments, as either a Rn decay daughter or an alpha particle emitted from a thin inner surface layer of a detector could produce a WIMP-like signal. Different surface treatment and cleaning techniques have been employed in the past to remove this type of contamination. A new method of dealing with the problem has been proposed and used for a prototype acrylic DEAP-1 detector. Inner surfaces of the detector were coated with a layer of ultra pure acrylic, meant to shield the active volume from alphas and recoiling nuclei. An acrylic purification technique and two coating techniques are described: a solvent-borne (tested on DEAP-1) and solvent-less (being developed for the full scale DEAP-3600 detector).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards successful cleaning of chert samples for improved 10Be and 26Al measurements

In situ-produced cosmogenic 10 Be and 26 Al measurements are widely applied in geomorphological studies and in archaeology and paleoanthropology as a chronologic tool applicable to the past 5 Ma. While most of these measurements are made from concentrates of quartz, a ubiquitous and resistant mineral, it is of great interest to extend this method to other silicates and particularly to the amorphous silicates whose purification may not be as straightforward. This paper presents a cleaning procedure that has been applied on ten samples of various siliceous rocks (chert, granite and quartzolite). The aim is to monitor the 10 Be, 27 Al and 26 Al concentration evolution as a function of cleaning steps. While this protocol appears suitable for 10 Be, when measuring 26 Al careful attention should be paid to 27 Al, whose concentration should be measured regularly to ensure that a constant value is achieved and most important, allowing measuring 26 Al/ 27 Al by AMS.

36 MATERIALS SCIENCE↗

Update of Emission Factors of Greenhouse Gases and Criteria Air Pollutants, and Generation Efficiencies of the U.S. Electricity Generation Sector

The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.

20 FOSSIL-FUELED POWER PLANTS↗

Techno-economic performances and life cycle greenhouse gas emissions of various ammonia production pathways including conventional, carbon-capturing, nuclear-powered, and renewable production

Ammonia (NH 3 ) is conventionally produced using fossil natural gas (NG) for hydrogen production through steam reformation and synthesis in the Haber–Bosch (HB) process. The global conventional ammonia production contributes more than 420 million tons of CO 2 emissions annually. Here, in this work, we investigated the techno-economics and well-to-plant-gate (WTG) greenhouse gas (GHG) emissions of conventional NG-based, carbon-capturing, nuclear-powered, and renewable ammonia production by developing an engineering process model for each. Carbon-capturing ammonia production refers to the NG-based ammonia production while capturing CO 2 and transporting it via pipelines for storage or utilization. Nuclear-powered and renewable ammonia production represents an alternative ammonia production through water electrolysis, air separation, and the HB process using carbon-free energy sources. Nuclear and renewable energy sources are assumed to be used for nuclear-powered and renewable ammonia production, respectively. Sensitivity analyses are performed for CO 2 pipeline transport distances, potential carbon capture tax credits, and clean H 2 production cost. Carbon-capturing ammonia production reduces WTG GHG emissions by 55–70% compared to conventional NG-based ammonia production methods. Nuclear-powered and renewable ammonia production almost eliminate GHG emissions since energy supply is either zero carbon or near-zero carbon. However, when $4.16–4.83 per kg is the cost assumed for clean H 2 production using state-of-the-art electrolysis technologies, the levelized costs of nuclear-powered and renewable ammonia are calculated to be $0.92–1.06 per kg NH 3 , which are approximately four times higher than the conventional NG-based ammonia production cost. The cost of CO 2 emission avoidance is estimated in the range of $266–318 per metric ton of CO 2 for nuclear-powered and renewable ammonia production. The clean H 2 production cost is the major contributor to the levelized costs of nuclear-powered and renewable ammonia production. A lower production cost, near $1 per kg H 2 , for clean H 2 is required for nuclear-powered and renewable ammonia production to be cost-competitive with conventional NG-based ammonia production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of the GEM chambers for the SBS/BB Front Tracker at JLAB HallA

The present thesis discusses the main aspects and results of the ongoing SBS-GEM development, production and test, according to the following structure: - In chapter 1 the theoretical and experimental importance of nucleon electromagnetic form factors is described. Furthermore, the discrepancy of ep scattering data obtained about the FFs ratio between the Rosenbluth separation method and the polarization transfer method is highlighted and, therefore, the Super Bigbite Program at JLab is introduced. - In chapter 2 the experimental apparatus of the SBS project is described, focusing on the main components of the spectrometers involved; the Super Bigbite Spectrometer for the hadron arm and the BigBite spectrometer for the electron arm. - Chapter 3 describes the SBS/BB front tracker and the motivation on the GEM technology choice. In addition, the main features and advantages of the technology used are also described. - Chapter 4 describes the commissioning of the GEM trackers at JLab. The whole iter of the GEM modules is presented, from the assembly in clean-room to the characterization tests with cosmic rays performed at JLab. - In chapter 5 a new method of analyzing the signals extracted from the strips of GEM modules is introduced. This study goal is the real-time suppression of noisy data by mean of innovative A.I. techniques.

Re, Leonard Giuseppe↗

Method of forming metal hydride films

The substrate to be coated (which may be of metal, glass or the like) is cleaned, both chemically and by off-sputtering in a vacuum chamber. In an ultra-high vacuum system, vapor deposition by a sublimator or vaporizer coats a cooled shroud disposed around the substrate with a thin film of hydride forming metal which getters any contaminant gas molecules. A shutter is then opened to allow hydride forming metal to be deposited as a film or coating on the substrate. After the hydride forming metal coating is formed, deuterium or other hydrogen isotopes are bled into the vacuum system and diffused into the metal film or coating to form a hydride of metal film. Higher substrate temperatures and pressures may be used if various parameters are appropriately adjusted.

Steinberg, R.↗

Life Cycle Costing in Radioactive Waste Packaging: Reducing Costs Whilst Accelerating Clean-Up - 16131

In recognition of the high up-front costs and potentially long timescales to implement the more traditional methods of encapsulating wastes, in the UK alternative approaches to help accelerate hazard reduction and reduce such costs are being deployed. When considering such the cost of alternative approaches to waste packaging strategies, it is important that the complete waste life cycle is taken into account. This paper will demonstrate that when evaluating waste packaging options, whilst individual elements (e.g. container costs) within an overall waste management programme may appear to offer a cost benefit by comparison with alternatives, the programme as a whole may not necessarily be the most cost effective solution when life cycle costs are taken into account, or when other technical issues are considered. To illustrate this point this paper will present a view of the application of LCC, utilising a number of waste packaging scenarios, to promote discussion and consideration of the benefits of undertaking a holistic assessment of the investment decision as part of an overall waste management strategy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calcium-organic matter fouling in nanofiltration: Synchrotron-based X-ray fluorescence and absorption near-edge structure spectroscopy for speciation

Calcium (Ca)-enhanced organic matter (OM) fouling of nanofiltration (NF) membranes leads to reduced flux during desalination and requires frequent cleaning. Fouling mechanisms are not fully understood, which limits the development of targeted fouling control methods. This study employed synchrotron-based X-ray fluorescence (XRF) and X-ray absorption near-edge structure (XANES) spectroscopy to quantify the spatial distribution and mass of Ca deposition as well as changes in the Ca coordination environment characteristic of specific fouling mechanisms, respectively. Bench-scale filtration experiments were performed using feed solutions containing Ca and ten different types of organic matter (OM), as well as the common scalants, calcium carbonate (CaCO 3 ) and calcium sulfate (CaSO 4 ). Osmotic backwash (OB) was performed at regular intervals for fouling control. Ca-OM aggregation resulted in greater flux decline and lower flux recovery during OB than Ca conditioning of membranes followed by filtration of feed solution with OM. Linear combination fitting (LCF) of XANES absorption spectra from fouled membranes indicated that Ca-OM aggregation preferentially occurred for OM types that exhibited both high carboxylic group and negative charge density. Consequently, these OM types exhibited greater deposition of Ca and TOC on the membrane surface when compared to other OM types. For the coexistence of scalants and OM, Ca speciation within the fouling layer was characteristic of both Ca bound to the membrane (i.e. potential bridging, charge screening) as well as Ca-OM aggregation and deposition mechanisms, while a range of crystal polymorphs were observed to occur simultaneously. XRF and XANES represent powerful tools for the elucidation of NF fouling mechanisms by quantification of Ca deposition as well as Ca speciation. Fouling control methods should target OM types with high carboxyl group density and negative charge to neutralize or eliminate interactions with Ca.

42 ENGINEERING↗

Preparation of layered thin film samples for angle-resolved photoemission spectroscopy

Materials with layered van der Waals crystal structures are exciting research topics in condensed matter physics and materials science due to outstanding physical properties associated with their strong two dimensional nature. Prominent examples include bismuth tritelluride and triselenide topological insulators (TIs), which are characterized by a bulk bandgap and pairwise counter-propagating spin-polarized electronic surface states. Angle-resolved photoemission spectroscopy (ARPES) of ex-situ grown thin film samples has been limited by the lack of suitable surface preparation techniques. We demonstrate the shortcomings of previously successful conventional surface preparation techniques when applied to ternary TI systems which are susceptible to severe oxidation. We show that in-situ cleaving is a simple and effective technique for preparation of clean surfaces on ex-situ grown thin films for high quality ARPES measurements. The method presented here is universally applicable to other layered van der Waals systems as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Locating PHEV exchange stations in V2G

Plug-in hybrid electric vehicle (PREV) is an environment friendly modem transportation method and has been rapidly penetrate the transportation system. Renewable energy is another contributor to clean power but the associated intermittence increases the uncertainty in power generation. As a foreseen benefit of a vchicle-to-grid (V2G) system, PREV supporting infrastructures like battery exchange stations can provide battery service to PREV customers as well as being plugged into a power grid as energy sources and stabilizer. The locations of exchange stations are important for these two objectives under constraints from both ,transportation system and power grid. To model this location problem and to understand and analyze the benefit of a V2G system, we develop a two-stage stochastic program to optimally locate the stations prior to the realizations of battery demands, loads, and generation capacity of renewable power sources. Based on this model, we use two data sets to construct the V2G systems and test the benefit and the performance of these systems.

25 ENERGY STORAGE↗

Hydrogen Life-Cycle Analysis in Support of Clean Hydrogen Production

Hydrogen is a basic molecule which is commonly used in the production of chemicals or as an energy carrier or a fuel. Its zero-carbon content means that it does not produce carbon dioxide upon its use. However, depending on the energy source and technology for hydrogen production and delivery, there can be greenhouse gas (GHG) emissions associated with the hydrogen for various end use applications. To provide the largest reduction in GHG emissions, hydrogen produced from clean energy sources should be used. As concerns regarding climate change grows, there is an increasing focus on economic production of clean hydrogen to displace less climate neutral sources of hydrogen. However, there are many different methods of hydrogen production with unique processes that result in different levels of life cycle GHG emissions of hydrogen production and its end use applications. Therefore, a comprehensive life cycle accounting methodology that takes all these factors into account is required. he GREET ® (Greenhouse gases, Regulated Emissions, and Energy use in Technologies) model was first developed in 1995 by Argonne National Laboratory with the support from the various offices of the U.S. Department of Energy (DOE). GREET provides in-depth Life Cycle Analysis (LCA) simulations for a variety of products and is available as an Excel spreadsheet (GREET Excel), or as an application (GREET .Net). Both versions are available for public download at no cost. This report accompanies GREET 2022 release to describe the major updates and expansions to the hydrogen technology pathways, and to provide data sources and sample carbon intensity results for each of the pathways.

08 HYDROGEN↗

Rapid thermal annealing of indium phosphide compound semiconductors

The rapid thermal annealing (RTA) of indium phosphide (InP) substrates using a proximity contact method and silicon nitride encapsulation is investigated. The surface conditions of the InP substrates following cleaning with procedures A and B are analyzed. Procedure A involves using an iodic acid solution to remove work-damage InP surface layers and B is a degasssing process and hydrofluoric acid solution for native oxide removal. AES, XPS, and SIMS data of the proximity contact and silicon nitride encapsulated annealed samples are examined. The data reveal that RTA using proximity contact with silicon wafers does not provide adequate protection; however, the InP sample is successfully annealed when protected by a silicon nitride encapsulant.

Biedenbender, Michael D.↗