Assessing the accuracy of time-fraction and ductility exhaustion approaches for creep-fatigue damage prediction through feature-test validation

Determining creep-fatigue damage formation is critical for elevated temperature components integrity. This study evaluates creep-fatigue assessments with emphasis on differences between creep damage models. Evaluated are the time-fraction model and the classical and stress-modified ductility exhaustion creep damage models. This work extends the domain of stress-modified ductility exhaustion models by introducing and validating such formalism to Ni-based alloys. The fidelity of the assessments was benchmarked against uniaxial creep-fatigue and multiaxial feature tests of Alloy 617. For uniaxial specimens, best estimate predictions rank ductility exhaustion as the most accurate and precise and time-fraction as markedly conservative. For feature tests, ductility exhaustion predictions are within < 4.0 times difference, whereas time-fraction underpredicts life by factors of 7–14. The observations suggest ductility exhaustion models as alternative to time-fraction models in design codes for situations requiring characterization of the design margin. Further work in employing such models to assess other relevant phenomena (e.g., stress relaxation cracking) is discussed.

creep-fatigue↗

Comparison of Second-Order Loads on a Semisubmersible Floating Wind Turbine: Preprint

As offshore wind projects move to deeper waters, floating platforms become the most feasible solution for supporting the turbines. The oil and gas industry has gained experience with floating platforms that can be applied to offshore wind projects. This paper focuses on the analysis of second-order wave loading on semisubmersible platforms. Semisubmersibles, which are being chosen for different floating offshore wind concepts, are particularly prone to slow-drift motions. The slack catenary moorings usually result in large natural periods for surge and sway motions (more than 100 s), which are in the range of the second-order difference-frequency excitation force. Modeling these complex structures requires coupled design codes. Codes have been developed that include turbine aerodynamics, hydrodynamic forces on the platform, restoring forces from the mooring lines, flexibility of the turbine, and the influence of the turbine control system. In this paper two different codes are employed: FAST, which was developed by the National Renewable Energy Laboratory, and aNySIM, which was developed by the Maritime Research Institute Netherlands. The hydrodynamic loads are based on potential-flow theory, up to the second order. Hydrodynamic coefficients for wave excitation, radiation, and hydrostatic forces are obtained with two different panel codes, WAMIT (developed by the Massachusetts Institute of Technology) and DIFFRAC (developed by MARIN). The semisubmersible platform, developed for the International Energy Agency Wind Task 30 Offshore Code Comparison Collaboration Continuation project is used as a reference platform. Irregular waves are used to compare the behavior of this platform under slow-drift excitation loads. The results from this paper highlight the effects of these loads on semisubmersible-type platforms, which represent a promising solution for the commercial development of the offshore deepwater wind resource.

17 WIND ENERGY↗

Ensuring statistical reproducibility of ocean model simulations in the age of hybrid computing

Novel high performance computing systems that feature hybrid architectures require large scale code refactoring to unravel underlying exploitable parallelism. Such redesign can often be accompanied with machine-precision changes as the order of computation cannot always be maintained. For chaotic systems like climate models, these round-off level differences can grow rapidly. Systematic errors may also manifest initially as machine-precision differences. Isolating genuine round off level differences from such errors remains a challenge. Here, we apply two-sample equality of distribution tests to evaluate statistical reproducibility of the ocean model component of US Department of Energy's Energy Exascale Earth System Model (E3SM). A 2-year control simulation ensemble is compared to a modified ensemble as a test case - after a known non-bit-for-bit change in a model component is introduced - to evaluate the null hypothesis that the two ensembles are statistically indistinguishable. To quantify the false negative rates of these tests, we conduct a formal power analysis using a targeted suite of short simulation ensembles. The ensemble suite contains several perturbed ensembles, each with a progressively different climate than the baseline ensemble - obtained by perturbing the magnitude of a single model tuning parameter, the Gent and McWilliams κ, in a controlled manner. The null hypothesis is evaluated for each of perturbed ensembles using these tests. The power analysis informs on the detection limits of the tests for given ensemble size allowing model developers to evaluate the impact of an introduced non-bit-for-bit change to the model.

Mahajan, Salil↗

Concepts and Meta-Programming Library

CAMP provides a portable optimized implementation of template meta-programming primitives. All capabilities found within are available in other open source projects, including metal and mpl among others, but no other library we know of supports all compilers required by LLNL codes. CAMP serves as an efficient facility for writing portable compile-time operations in C++ codes. It was developed as part of the RAJA project to facilitate more complex compile-time introspection and better error message delivery to users, but has since proven useful in Umpire, CHAI and other pre-release LLNL software projects and is thus being re-factored to stand alone. The CAMP library uses portable C++ template mechanisms almost exclusively, with the exception of intrinsics provided for performance by some compilers such as clang and gee. There are no private or protected interfaces and no proprietary information included in the source. Any and all future versions will limit themselves to implementing commonly available and well known primitives for compile-time manipulation of types. A new public github repository will be created to host the code independent of its current location in the raja repository, likely at github.com/llnl/camp.

Kunen, AdamJ.↗

SolTrace™ (Optical Analysis Software) [SWR-26-065 and SWR-01-45]

SolTrace™ is a software tool developed at the National Renewable Energy Laboratory (NREL) to model concentrating solar power (CSP) systems and analyze their optical performance. Although ideally suited for solar applications, the code can also be used to model and characterize many general optical systems. The creation of the code evolved out of a need to model more complex solar optical systems than could be modeled with existing tools. SolTrace can be installed either using the official NREL packaged distribution or from source code at the SolTrace open source project website. NREL welcomes contributions from programmers to the simulation engine or to the interface and encourages interested persons to get involved. More information on contributing, compiling the source code, and license requirements is available on the project website.(https://www.nrel.gov/csp/soltrace.html). For details on integration with SAM, see the SAM website. (https://sam.nrel.gov/)

Wendelin, Tim↗

Simulation of Wave Interactions with Magnetohydrodynamics (SWIM) SciDAC (Scientific Discovery through Advanced Computing) Project

The Center for Simulation of Wave Interactions with Magnetohydrodynamics (SWIM) was begun in 2005 with as a partnership between the DOE Office of Fusion Energy (FES) and the Office of Advanced Supercomputing Research (ASCR) to serve as a prototype for a comprehensive Fusion Simulation Project (FSP). The purpose was to begin the process of multi-physics, multi-scale coupling, at a reduced scope from a full FSP, while addressing problems of programmatic importance, and to develop approaches to large-scale code integration as required for the full FSP. The scientific objectives of SWIM were to improve our understanding of interactions that both RF wave and particle sources have on extended-MHD phenomena, to improve our capability for predicting and optimizing the performance of burning plasmas, to develop an integrated computational system for treating multi-physics phenomena with the required flexibility and extensibility to serve as a prototype for the Fusion Simulation Project, to address mathematics issues related to the multi-scale, coupled physics of RF waves and extended MHD, and to optimize the integrated system on high performance computers. The SWIM project ended in 2012 and the FSP, for which SWIM was to serve as a prototype, was not begun.

Batchelor, Donald↗

Upgrade the EMPIRE code as needed for evaluation and production of covariances for actinides

Treatment of actinides in the EMPIRE code has been updated by adding capabilities necessary for effective assimilation of nuclei that undergo fission. The upgrades comprise calculations of Prompt Fission Neutron Spectra (PFNS), and the average cosine of elastically scattered neutrons ($\overline{µ}$) and include sensitivity and covariance computations for both quantities. In addition, EMPIRE outputs the average number of neutrons released per fission event ($\overline{ν}$) that is read from the existing evaluated file and scaled by a factor. Kalman filter is used to fit calculated PFNS, $\overline{µ}$, and $\overline{ν}$ to the experimental data and to produce covariances for the quantities and respective model parameters. These updates expand EMPIRE assimilation possibilities by adding PFNS, $\overline{ν}$, and $\overline{µ}$ to the physical quantities that might be perturbed along with the cross sections during the adjustment. We describe PFNS models used in the EMPIRE code, the modifications required to accommodate these models, and detail updates to the EMPIRE scripts used for fitting, and illustrate the new features applying them to specific nuclei. Finally, we report on actual assimilation of 239 Pu performed by calculating sensitivity of the JEZEBEL $k_{eff}$ to the full set of reaction model parameters (EMPIRE+MCNP) and using Kalman filter to perform adjustment of the parameters. This work was performed according to the goals set forth in milestones M3FT-12BN0210011 and M3FT-12BN0210012.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Katipamula, Srinivas↗

Trinity Era Storage

This report discusses the Trinity Storage system, its infrastructure, requirements, and erasure code.

97 MATHEMATICS AND COMPUTING↗

Site 300 SPCC Plan

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL) Experimental Test Site (Site 300) near Tracy, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations, Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at Site 300. This SPCC Plan has been prepared for the entire Site 300 facility and replaces the three previous plans prepared for Site 300: LLNL SPCC for Electrical Substations Near Buildings 846 and 865 (LLNL 2015), LLNL SPCC for Building 883 (LLNL 2015), and LLNL SPCC for Building 801 (LLNL 2014).

54 ENVIRONMENTAL SCIENCES↗

Livermore Site Spill Prevention, Control, and Countermeasures (SPCC) Plan

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL) Livermore Site in Livermore, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations (40 CFR), Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at the Livermore Site.

54 ENVIRONMENTAL SCIENCES↗

Site 300 Spill Prevention, Control, and Countermeasures (SPCC) Plan

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL) Experimental Test Site (Site 300) near Tracy, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations, Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at Site 300. This SPCC Plan has been prepared for the entire Site 300 facility and replaces the three previous plans prepared for Site 300: LLNL SPCC for Electrical Substations Near Buildings 846 and 865 (LLNL 2015), LLNL SPCC for Building 883 (LLNL 2015), and LLNL SPCC for Building 801 (LLNL 2014).

54 ENVIRONMENTAL SCIENCES↗

Livermore Site SPCC Plan - Dececember 2017

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL’s) Livermore Site in Livermore, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations (40 CFR), Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at the Livermore Site.

54 ENVIRONMENTAL SCIENCES↗

LLNL Livermore Site Spill Prevention, Control, and Countermeasure (SPCC) Plan June 2018

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL ’s) Livermore Site in Livermore, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations (40 CFR) , Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapt er 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for above ground oil storage and use at the Livermore Site.

54 ENVIRONMENTAL SCIENCES↗

Lawrence Livermore National Laboratory Site 300 Spill Prevention, Control, and Countermeasures Plan

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL’s) Experimental Test Site (Site 300) near Tracy, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations, Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at Site 300. This SPCC Plan has been prepared for the entire Site 300 facility and replaces the three previous plans prepared for Site 300: LLNL SPCC for Electrical Substations Near Buildings 846 and 865 (LLNL 2015), LLNL SPCC for Building 883 (LLNL 2015), and LLNL SPCC for Building 801 (LLNL 2014). The SPCC Plan is intended for distribution to all LLNL personnel who operate, maintain, and are responsible for containers of oil (oil-handlers). The updated Plan is available online at: https://eshint. llnl.gov/spcc/spcc-hp.html.

54 ENVIRONMENTAL SCIENCES↗

Comparative Assessment of Experimental Testing of Instrument with an Embedded Digital Device Using Model-Based and Conventional Methods

The use of digital equipment has not been widespread in U.S. nuclear facilities. A major contributing factor to this situation arises from regulatory concerns about common cause failures (CCFs) stemming from the use of identical software in redundant systems, questions as to how to quantify the reliability of software-based products, validity of tools that are used for software verification and validation (V&V), and the effectiveness of software QA procedures. Compounding the concerns are sporadic incidents of digital equipment malfunctions in nuclear power plants, including lockups resulting from software memory leaks, feedwater control malfunctions due to excessive traffic on Ethernet networks, software logic errors, and other problems leading to plant trips. Additionally, the limited amount of demonstrated research and a lack of industry consensus on quantitative software reliability methodologies has hindered the widespread adoption of digital I&C in the nuclear industry. In a recent Regulatory Issue Summary (RIS), the U.S. Nuclear Regulatory Commission (NRC) identified concerns about the impact of greater use of instrumentation and control (I&C) equipment with an embedded digital device (EDD) [1]. Specifically, the NRC staff states that increased use of such devices “may increase a facility’s vulnerability to a CCF” (i.e., common-cause failure). The prevailing NRC guidance regarding software CCF (SCCF) identifies two design attributes that are acceptable for eliminating CCF concerns: (1) diversity or (2) testability (specifically, 100% testability). Either solution can result in high costs and remaining licensing uncertainty (i.e., how much diversity is enough? how to ensure test coverage of every possible sequence of device states?). Consequently, many utilities and reactor designers have limited or avoided more extensive use of digital technology to minimize licensing, scheduling, and financial risk. Without development of cost effective qualification methods to satisfy regulatory requirements and address the potential for CCF vulnerability associated with EDDs, the nuclear power industry may not be able to realize the benefits of digital technology achieved by other industries. In order to address these challenges, the U.S. Department of Energy (DOE) is sponsoring this research to assess the prospect of CCF in digital I&C equipment. The purpose of the current research is to develop an effective approach employing science-based methods to resolve concerns about CCF vulnerability that serve to inhibit deployment of advanced instrumentation (e.g., sensors, actuators, microcontrollers) with EDDs in nuclear power applications. The research objectives address the challenge of establishing high levels of safety and reliability assurance needed for the qualification of EDDs (e.g., microprocessors, programmable logic devices) that are subject to software design faults, complex failure modes, and CCF vulnerability. Specific objectives are: (1) assess the regulatory context for treatment of CCF vulnerability a graded approach to their qualification, (3) develop and extend model-based testing methods to enable effective demonstration of whether devices are subject to CCF, which may arise from vulnerabilities introduced at any stage of the design lifecycle, (4) establish a cost-effective testing framework that incorporates automation and test scenario prioritization, and (5) demonstrate the qualification approach through selection and testing of candidate digital device(s). This report documents an assessment of the results from experimental testing of a representative instrument with an embedded digital device. The experiment serves as a proof-of-concept demonstration of a model-based testing (MBT) framework. The objective of MBT is to ensure that an EDD undergoes suitably comprehensive testing to establish that it is not subject to SCCF. The approach by which MBT accomplishes this objective is through development and application of an effective test suite that provides the appropriate coverage to detect the full range of postulated faults that may arise at the requirements, design, and code (implementation) level of the EDD software. The findings of the experiment involve the application of the MBT framework by Ohio State University (OSU) through testing of the selected demonstration instrument (i.e., the prototype smart pressure sensor developed by Virginia Commonwealth University, VCU). In addition, the experiment findings also involve application of a more conventional black-box testing approach that serves as a baseline against which the MBT methodology can be compared. The primary outcome documented in this report is the comparative analysis of the capabilities demonstrated for each method. The results of the analysis demonstrate clear benefits that arise from the MBT methodology. The comparison indicates greater effectiveness from the more comprehensive evidence available through MBT and enhanced efficiency achieved through automation within the MBT framework. The structure of the report addresses the approach and application of each test method as well as the comparative analysis of the experimental results. Chapter 2 gives a summary overview of the demonstration approach. Chapter 3 covers the baseline testing and Chapter 4 documents the model-based testing. Chapter 5 describes the findings of the comparative analysis and presents the conclusions that can be drawn about the effectiveness and efficiency of the MBT methodology.

47 OTHER INSTRUMENTATION↗

Livermore Site Spill Prevention, Control and Countermeasures (SPCC) Plan

This Spill Prevention, Control, and Countermeasure (SPCC) Plan describes the measures that are taken at Lawrence Livermore National Laboratory’s (LLNL’s) Livermore Site in Livermore, California, to prevent, control, and handle potential spills from aboveground containers that can contain 55 gallons or more of oil. This SPCC Plan complies with the Oil Pollution Prevention regulation in Title 40 of the Code of Federal Regulations (40 CFR), Part 112 (40 CFR 112) and with 40 CFR 761.65(b) and (c), which regulates the temporary storage of polychlorinated biphenyls (PCBs). This Plan has also been prepared in accordance with Division 20, Chapter 6.67 of the California Health and Safety Code (HSC 6.67) requirements for oil pollution prevention (referred to as the Aboveground Petroleum Storage Act [APSA]), and the United States Department of Energy (DOE) Order No. 436.1. This SPCC Plan establishes procedures, methods, equipment, and other requirements to prevent the discharge of oil into or upon the navigable waters of the United States or adjoining shorelines for aboveground oil storage and use at the Livermore Site.

54 ENVIRONMENTAL SCIENCES↗

Meteorological Tower Network Expansion Pilot Project Siting Considerations to Ensure Data Quality and Representativeness of Three New Meteorological Towers at Los Alamos National Laboratory

Associated with the Meteorological Tower Network Expansion Pilot Project by the Environmental Protection and Compliance (EPC) Compliance Programs (CP) Meteorology and Air Quality (MAQ) team, the purpose of this technical report is to establish requisite justification for the siting of three 10-meter high instrumented meteorological towers at three new locations on the Los Alamos National Laboratory (LANL) site. These towers and their associated instrumentation are similar in scope to the existing 10-meter meteorological tower that is collecting meteorological data in Mortandad Canyon (MDCN). The conclusions and recommendations in this technical report will inform LANL management, EPC-CP MAQ staff, and other LANL divisions of the criteria employed for the selection of the final location for siting these three new towers. Meeting such comprehensive criteria will ensure that all data acquired will be spatially representative for meeting the diverse Safety Basis (SB), emergency management, and operations organizations programmatic needs and analytical data input requirements to its codes.

54 ENVIRONMENTAL SCIENCES↗