Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-BRB-06: Dosimetric Impact of Breast Contour Reconstruction Errors in GammaPod Stereotactic Radiotherapy

Purpose: The first GammaPod™ unit, a dedicated prone stereotactic treatment device for early stage breast cancer, has been installed and commissioned at University of Maryland School of Medicine. The objective of this study was to investigate potential dosimetric impact of inaccurate breast contour. Methods: In GammaPod treatments, patient’s beast is immobilized by a breast cup device (BCID) throughout the entire same-day imaging and treatment procedure. 28 different BICD sizes are available to accommodate patients with varying breast sizes. A mild suction helps breast tissue to conform to the shape of the cup with selected size. In treatment planning, dose calculation utilizes previously calculated dose distributions for available cup geometry rather than the breast shape from CT image. Patient CT images with breast cups indicate minor geometric discrepancy between the matched shape of the cup and the breast contour, i.e., the contour size is larger or smaller. In order to investigate the dosimetric impact of these discrepancies, we simulated such discrepancies and reassessed the dose to target as well as skin. Results: In vicinity of skin, hot/cold spots were found when matched cup size was smaller/larger than patient’s breast after comparing the corrected dose profiles from Monte Carlo simulation with the planned dose from TPS. The overdosing/underdosing of target could yield point dose differences as large as 5% due to these setup errors (D95 changes within 2.5%). Maximal skin dose was overestimated/underestimated up to 25%/45% when matched cup size was larger/smaller than real breast contour. Conclusion: The dosimetric evaluation suggests substantial underdosing/overdosing with inaccurate cup geometry during planning, which is acceptable for current clinical trial. Further studies are needed to evaluate such impact to treating small volume close to skin.

60 APPLIED LIFE SCIENCES↗

In comparison with other abdominal imaging modalities, which radiologists interpret abdominal MRI?

Purpose: To assess subspecialty mix and case volumes of general and abdominal subspecialty radiologists interpreting abdominal MRI. Methods: The 2016 CMS Physician/Supplier Procedure Summary Master File was used to obtain billed counts of radiologist-interpreted abdominal fluoroscopy, US, CT, and MRI examinations. The CMS Physician and Other Supplier Public Use File was used to assess the subspecialty mix and case volume of the radiologists interpreting those examinations. Results: The fraction of all abdominal imaging examinations interpreted by generalists and abdominal subspecialty radiologists was 70.7% and 16.5% for fluoroscopy; 68.7% and 21.0% for US; 71.4% and 19.2% for CT; and 41.9% and 52.5% for MRI. In 2016, the fraction of general and abdominal radiologists interpreting > 50 fluoroscopy examinations on Medicare fee-for-service beneficiaries was 15.1% and 16.2%. For > 50 US examinations, the fraction was 61.5% and 60.5%; for > 50 CT examinations, 91.2% and 79.6%; and for > 50 MRI examinations, 4.0% and 28.5%. The fraction of abdominal imaging examinations interpreted overall by low-volume providers (those interpreting ≤ 50 examinations in 2016) was 59.5% for fluoroscopy, 17.5% for US, 6.3% for CT, and 50.6% for MRI. Conclusion: Nationally, most abdominal fluoroscopy, US, and CT examinations are interpreted by general radiologists, who have similar annual volumes of these examinations as abdominal subspecialty radiologists. In contrast, most abdominal MRI examinations are interpreted by abdominal subspecialty radiologists, who attain considerably higher volumes. These findings have implications for workforce planning and abdominal imaging fellowship design to ensure their graduates are optimally prepared to contribute to their future practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermo-Hydraulic-Mechanical Modelling of the Full-Scale Emplacement (FE) Experiment at the Mont Terri Rock Laboratory - 16490

The Full-Scale Emplacement Experiment at the Mont Terri underground research laboratory is a heater test carried out in a gallery constructed in Opalinus Clay. The aim of the experiment is both to develop emplacement procedures for radioactive waste canisters and their surrounding backfill as well as understanding the thermo-hydro-mechanical effects of disposing of radioactive waste on the engineering materials and the host rock. Coupled thermo-hydro-mechanical models have been used to aid planning of the locations of sensors, to inform decisions on the schedule for turning on the heaters as well as to make predictions of the temperatures and water pressures in the bentonite and the Opalinus Clay. The FE Experiment was preceded by a number of other experiments at the Mont Terri laboratory at smaller scales, but with similar materials, which provided crucial input to the models and gave confidence in the general process understanding. Blind predictions were made prior to turning on the heaters, of the temperature and relative humidity in the bentonite surrounding the heaters. The comparison between the blind predictions and early data from the experiment show that knowledge gained from smaller scale experiments on similar materials has enabled good blind predictions to be made and gives confidence that temperature in the experiment is unlikely to rise to a level that could damage the sensors. It also demonstrates that the thermal properties of the disposal system are understood well enough to produce reliable estimates of temperature in the backfill. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of an online adaptive replanning method for cranial frameless intensity-modulated radiosurgery

To introduce an approach for online adaptive replanning (i.e., dose-guided radiosurgery) in frameless stereotactic radiosurgery, when a 6-dimensional (6D) robotic couch is not available in the linear accelerator (linac). Cranial radiosurgical treatments are planned in our department using intensity-modulated technique. Patients are immobilized using thermoplastic mask. A cone-beam computed tomography (CBCT) scan is acquired after the initial laser-based patient setup (CBCT{sub setup}). The online adaptive replanning procedure we propose consists of a 6D registration-based mapping of the reference plan onto actual CBCT{sub setup}, followed by a reoptimization of the beam fluences (“6D plan”) to achieve similar dosage as originally was intended, while the patient is lying in the linac couch and the original beam arrangement is kept. The goodness of the online adaptive method proposed was retrospectively analyzed for 16 patients with 35 targets treated with CBCT-based frameless intensity modulated technique. Simulation of reference plan onto actual CBCT{sub setup}, according to the 4 degrees of freedom, supported by linac couch was also generated for each case (4D plan). Target coverage (D99%) and conformity index values of 6D and 4D plans were compared with the corresponding values of the reference plans. Although the 4D-based approach does not always assure the target coverage (D99% between 72% and 103%), the proposed online adaptive method gave a perfect coverage in all cases analyzed as well as a similar conformity index value as was planned. Dose-guided radiosurgery approach is effective to assure the dose coverage and conformity of an intracranial target volume, avoiding resetting the patient inside the mask in a “trial and error” way so as to remove the pitch and roll errors when a robotic table is not available.

61 RADIATION PROTECTION AND DOSIMETRY↗

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-CAMPUS-JeP3-05: Adaptive Determination of Needle Sequence HDR Prostate Brachytherapy with Divergent Needle-By-Needle Delivery

Purpose: To develop a new method which adaptively determines the optimal needle insertion sequence for HDR prostate brachytherapy involving divergent needle-by-needle dose delivery by e.g. a robotic device. A needle insertion sequence is calculated at the beginning of the intervention and updated after each needle insertion with feedback on needle positioning errors. Methods: Needle positioning errors and anatomy changes may occur during HDR brachytherapy which can lead to errors in the delivered dose. A novel strategy was developed to calculate and update the needle sequence and the dose plan after each needle insertion with feedback on needle positioning errors. The dose plan optimization was performed by numerical simulations. The proposed needle sequence determination optimizes the final dose distribution based on the dose coverage impact of each needle. This impact is predicted stochastically by needle insertion simulations. HDR procedures were simulated with varying number of needle insertions (4 to 12) using 11 patient MR data-sets with PTV, prostate, urethra, bladder and rectum delineated. Needle positioning errors were modeled by random normally distributed angulation errors (standard deviation of 3 mm at the needle’s tip). The final dose parameters were compared in the situations where the needle with the largest vs. the smallest dose coverage impact was selected at each insertion. Results: Over all scenarios, the percentage of clinically acceptable final dose distribution improved when the needle selected had the largest dose coverage impact (91%) compared to the smallest (88%). The differences were larger for few (4 to 6) needle insertions (maximum difference scenario: 79% vs. 60%). The computation time of the needle sequence optimization was below 60s. Conclusion: A new adaptive needle sequence determination for HDR prostate brachytherapy was developed. Coupled to adaptive planning, the selection of the needle with the largest dose coverage impact increases chances of reaching the clinical constraints. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

60 APPLIED LIFE SCIENCES↗

Development of the Advanced D1S for Shutdown Dose Rate Calculations in Fusion Reactors

The assessment of the shutdown dose rate due to neutron activation is fundamental for shielding design, materials selection, licensing and planning of maintenance operations in high performances fusion devices. The shutdown dose rate calculations require the combined use of radiation transports and inventory codes. The typical approach consists in a two steps procedure. A pure neutron transport simulation is performed in a first step to calculate the spatial distribution of neutron spectra. The results are used as input for an activation calculation that provides the decay gamma source used in a second step for a pure gamma transport simulation (rigorous-two step, R2S). The Direct 1-Step (D1S) approach has been developed more than ten years ago by ENEA and the ITER team: this technique relies on a coupled neutron-decay gamma transport in a single simulation. It is based on the use of a modified version of the MCNP5 Monte Carlo code with specially tailored nuclear cross-section data for transport and FISPACT inventory code for temporal behaviour. The 'Advanced-D1S' is an improved version of D1S in which additional computational features have been introduced, such as the mesh tally capability and continuous time evolution assessment of the dose rate in single run dose. It has been validated through measurements at JET tokamak and comparison with R2S codes and a future benchmark experiment during next high performance deuterium-tritium campaign is in preparation at JET. It has also been extensively used for ITER calculations and recently applied to DEMO assessment. Present limitations and in progress code improvement strategy are described and discussed in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

RADIATION TRANSPORT FOR EXPLOSIVE OUTFLOWS: OPACITY REGROUPING

Implicit Monte Carlo (IMC) and Discrete Diffusion Monte Carlo (DDMC) are methods used to stochastically solve the radiative transport and diffusion equations, respectively. These methods combine into a hybrid transport-diffusion method we refer to as IMC-DDMC. We explore a multigroup IMC-DDMC scheme that in DDMC, combines frequency groups with sufficient optical thickness. We term this procedure ''opacity regrouping''. Opacity regrouping has previously been applied to IMC-DDMC calculations for problems in which the dependence of the opacity on frequency is monotonic. We generalize opacity regrouping to non-contiguous groups and implement this in SuperNu, a code designed to do radiation transport in high-velocity outflows with non-monotonic opacities. We find that regrouping of non-contiguous opacity groups generally improves the speed of IMC-DDMC radiation transport. We present an asymptotic analysis that informs the nature of the Doppler shift in DDMC groups and summarize the derivation of the Gentile-Fleck factor for modified IMC-DDMC. We test SuperNu using numerical experiments including a quasi-manufactured analytic solution, a simple 10 group problem, and the W7 problem for Type Ia supernovae. We find that opacity regrouping is necessary to make our IMC-DDMC implementation feasible for the W7 problem and possibly Type Ia supernova simulations in general. We compare the bolometric light curves and spectra produced by the SuperNu and PHOENIX radiation transport codes for the W7 problem. The overall shape of the bolometric light curves are in good agreement, as are the spectra and their evolution with time. However, for the numerical specifications we considered, we find that the peak luminosity of the light curve calculated using SuperNu is ∼10% less than that calculated using PHOENIX.

79 ASTRONOMY AND ASTROPHYSICS↗

Transition into the improved core confinement mode as a possible mechanism for additional electron heating observed in the lower hybrid current drive experiments at the FT-2 tokamak

In experiments on lower hybrid current drive (LHCD) carried out at the FT-2 tokamak, a substantial increase in the central electron temperature T{sub e}(r = 0 cm) from 550 to 700 eV was observed. A complex simulation procedure is used to explain a fairly high LHCD efficiency and the observed additional heating, which can be attributed to a transition into the improved core confinement (ICC) mode. For numerical simulations, data obtained in experiments with deuterium plasma at 〈n{sub e}〉 = 1.6 × 10{sup 19} m{sup –3} were used. Simulations by the GRILL3D, FRTC, and ASTRA codes have shown that the increase in the density and central temperature is apparently caused by a significant suppression of heat transport in the electron component. The mechanism for transition into the improved confinement mode at r < 3 cm can be associated with the broadening of the plasma current channel due to the lower hybrid drive of the current carried by superthermal and runaway electrons. In this case, the magnetic shear s = (r/q)(dq/dr) in the axial region of the plasma column almost vanishes during the RF pulse. In this study, the effect of lower hybrid waves on the plasma parameters, resulting in a transition into the ICC mode, is considered. New experimental and calculated data are presented that evidence in favor of such a transition. Special attention is paid to the existence of a threshold for the transition into the ICC mode in deuterium plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of critical experiment correlations for experiments involving arrays of low-enriched fuel rods

Quantifying correlations among critical experiments has become a topic of interest over the last 10-15 years. Correlations arise from the shared use of fissile material, non-fissile materials, fixtures, and procedures in multiple experiments or multiple experiment series. A Monte-Carlo sampling technique proposed as a viable technical method to evaluate these correlations has been implemented in the SCALE 6.2 Sampler sequence. This paper presents an investigation of the use of this new tool and technique for low-enriched uranium pin array experiments with a thermal neutron energy spectrum. The Nuclear Energy Agency's Expert Group on Uncertainty Analyses for Criticality Safety Assessments has been examining methods of calculating the correlation coefficients among experiments from the LCT-007 and LCT-039 series. Results for two scenarios are presented to demonstrate the impact of pin pitch uncertainty modeling on the correlation coefficients. The convergence of the correlation coefficients is also investigated. Additional studies examine the impact of the stochastic uncertainty and the use of continuous-energy Monte-Carlo for individual realizations on the correlation coefficients. Correlation coefficients are also determined for the LCT-042 experiment series. This experiment series differs from other experiments because unique poison panels and fuel array separation distances may reduce correlation of the individual experiments within the series. The effects of pin pitch uncertainty and stochastic uncertainty are also examined for this series. Comparing the results of the two sets of experiments shows potential conclusions that can be drawn regarding viability of the Monte-Carlo sampling technique for determining critical experiment correlations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-407: Evaluation of Four Commercial Dosimetry Systems for Routine Patient-Specific Tomotherapy Delivery Quality Assurance

Purpose: The purpose of this project was to evaluate the performance of four commercially available dosimetry systems for Tomotherapy delivery quality assurance (DQA). Methods: Eight clinical patient plans were chosen to represent a range of treatment sites and typical clinical plans. Four DQA plans for each patient plan were created using the TomoTherapy DQA Station (Hi-Art version 4.2.1) on CT images of the ScandiDose Delta4, IBA MatriXX Evolution, PTW Octavius 4D and Sun Nuclear ArcCHECK phantoms. Each detector was calibrated following the manufacture-provided procedure. No angular response correction was applied. All DQA plans for each detector were delivered on the Tomotherapy Hi-Art unit in a single measurement session but on different days. The measured results were loaded into the vendor supplied software for each QA system for comparison with the TPS-calculated dose. The Gamma index was calculated using 3%/3mm, 2%/2mm with 10% dose threshold of maximum TPS calculated dose. Results: Four detector systems showed comparable gamma pass rates for 3%/3m, which is recommended by AAPM TG119 and commonly used within the radiotherapy community. The averaged pass rates ± standard deviation for all DQA plans were (98.35±1.97)% for ArcCHECK, (99.9%±0.87)% for Matrix, (98.5%±5.09)% for Octavius 4D, (98.7%±1.27)% for Delata4. The rank of the gamma pass rate for individual plans was consistent between detectors. Using 2%/2mm Gamma criteria for analysis, the Gamma pass rate decreased on average by 9%, 8%, 6.6% and 5% respectively. Profile and Gamma failure map analysis using the software tools from each dosimetry system indicated that decreased passing rate is mainly due to the threading effect of Tomo plan. Conclusion: Despite the variation in detector type and resolution, phantom geometry and software implementation, the four systems demonstrated similar dosimetric performance, with the rank of the gamma pass rate consistent for the plans considered.

60 APPLIED LIFE SCIENCES↗

Monte-Carlo Simulations of the Nuclear Energy Deposition Inside the CARMEN-1P Differential Calorimeter Irradiated into OSIRIS Reactor

The nuclear heating measurements in Material Testing Reactors (MTRs) are crucial for the study of nuclear materials and fuels under irradiation. The reference measurements of this nuclear heating are especially performed by a differential calorimeter including a graphite sample material. These measurements are then used for other experimental conditions in order to predict the nuclear heating and thermal conditions induced in the irradiation devices. Nuclear heating is a great deal of interest at the moment as the measurement of such heating is an important issue for MTRs reactors. This need is especially generated by the new Jules Horowitz Reactor (JHR), under construction at CEA/Cadarache 'French Alternative Energies and Atomic Energy Commission'. This new reactor, that will be operational in late 2019, is a new facility for the nuclear research on materials and fuels. Indeed the expected nuclear heating rate is about 20 W/g for nominal capacity of 100 MW. The present Monte Carlo calculation works belong to the IN-CORE (Instrumentation for Nuclear radiation and Calorimetry On line in Reactor): a joint research program between the CEA and Aix- Marseille University in 2009. One scientific aim of this program is to design and develop a multi-sensors device, called CARMEN, dedicated to the measurements of main physical parameters simultaneously encountered inside JHR's experimental channels (core and reflector) such as neutron fluxes, photon fluxes, temperature, and nuclear heating. A first prototype was already developed. This prototype includes two mock-ups dedicated respectively to neutronic measurements (CARMEN-1N) and to photonic measurements (CARMEN-1P) with in particular a specific differential calorimeter. Two irradiation campaigns were performed successfully in the periphery of OSIRIS reactor (a MTR located at Saclay, France) in 2012 for nuclear heating levels up to 2 W/g. First Monte Carlo calculations reduced to the graphite sample of the calorimeter were carried out. A preliminary analysis shows that the numerical results overestimate the measurements by about 20 %. A new approach has been developed in order to estimate the nuclear heating by two methods (energy deposition or KERMA) by considering the whole complete geometry of the sensor. This new approach will contribute to the interpretation of the irradiation campaign and will be useful to improve the out-of-pile calibration procedure of the sensor and its thermal response during irradiations. The aim of this paper is to present simulations made by using MCNP5 Monte-Carlo transport code (using ENDF/B-VI nuclear data library) for the nuclear heating inside the different parts of the calorimeter (head, rod and base). Calculations into two steps will be realized. We will use as an input source in the model new spectra (neutrons, prompt-photons and delayed-photons) calculated with the Monte Carlo code TRIPOLI-4{sup R} inside different experimental channels (water) located into the OSIRIS periphery and used during the CARMEN-1P irradiation campaign. We will consider Neutrons- Photons-Electrons and Photons-Electrons modes. We will begin by a brief description of the differential-calorimeter device geometry. Then the MCNP5 model used for the calculations of nuclear heating inside the calorimeter elements will be introduced. The energy deposition due to the prompt-gamma, delayed-gamma and neutrons, the neutron-activation of the device will be considered. The different components of the nuclear heating inside the different parts of the calorimeter will be detailed. Moreover, a comparison between KERMA and nuclear energy deposition estimations will be given. Finally, a comparison between this total nuclear heating Calculation and Experiment in graphite sample will be determined. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laparoscopic Cytoreductive Surgery with Hyperthermic Intraperitoneal Chemotherapy (L-CRS/HIPEC) for Perforated Low-Grade Appendiceal Mucinous Neoplasm (LAMN II)

Introduction: Cytoreductive surgery with hyperthermic intraperitoneal chemotherapy (CRS/HIPEC) is an established treatment for pseudomyxoma peritonei resulting from a perforated low-grade appendiceal mucinous neoplasm (LAMN II). In patients with localized disease, a laparoscopic procedure (L-CRS/HIPEC) can be undertaken. Methods: This video demonstrates L-CRS/HIPEC in a 66-year-old male who had previously undergone an appendicectomy for an LAMN II lesion. The preoperative computed tomography (CT) scan suggested disease localized to the right iliac fossa. However, laparoscopic assessment unexpectedly revealed disease in the pelvis and on the right hemidiaphragm and liver surface. Results: A technique for treating the thin film of mucin in the pelvis and on the right hemidiaphragm is demonstrated. The liver is mobilized to facilitate ablation of mucin on the serosal surface of the right lobe. Tips and tricks for starting the omentectomy, dealing with the vascular pedicle, and completing the dissection in the left upper quadrant are shown. The Peritoneal Cancer Index (PCI) score was 5 (3 for the right upper quadrant, 1 for the pelvis, 1 for the small bowel), and the cytoreduction score was CC-1. The operative duration was 8.5 h, and length of hospital stay was 5 days. The patient returned to work after 6 weeks. Discussion: L-CRS/HIPEC can be performed when patients are unexpectedly found to have disease, provided the appendiceal pathology is low grade and the PCI score is low. There are potential benefits to this approach, with a shorter length of hospital stay and faster functional recovery when compared with traditional open surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced instrumentation and analysis methods for in-pile thermal and nuclear measurements: from out-of-pile studies to irradiation campaigns

Research and development on nuclear fuel behavior under irradiations and accelerated ageing of structure materials is a key issue for sustainable nuclear energy in order to meet specific needs by keeping the best level of safety. A new Material Testing Reactor (MTR), the Jules Horowitz Reactor (JHR) currently under construction in the South of France in the CEA Cadarache research centre will offer a real opportunity to perform R and D programs and hence will crucially contribute to the selection, optimization and qualification of innovative materials and fuels. To perform such programs advanced accurate and innovative experiments, irradiation devices that contain material and fuel samples are required to be set up inside or beside the reactor core. These experiments needs beforehand in situ and on line sophisticated measurements to accurately reach specific and determining parameters such as thermal and fast neutron fluxes, nuclear heating and temperature conditions to precisely monitor and control the conducted assays. Consequently, since 2009 CEA and Aix-Marseille University collaborate in order to design and develop a new multi-sensor device which will be dedicated to measuring profiles of such conditions inside the experimental channels of the JHR. These works are performed in the framework of two complementary joint research programs called MAHRI-BETHY and INCORE. These programs couple experimental studies carried out both out-of nuclear fluxes (in laboratory) and under irradiation conditions (in OSIRIS MTR reactor in France and MARIA MTR reactor in Poland) with numerical works realized by thermal simulations (CAST3M code) and Monte Carlo simulations (MCNP code). These programs deal with three main aims. The first one corresponds to the design and/or the test of new in-pile instrumentation. The second one concerns the development of advanced calibration procedures in particular in the case of one specific sensor: a differential calorimeter used to quantify nuclear heating. The last one consists in the development of accurate measurement and analysis methods. The paper will be dedicated to a complete review of the experimental and numerical works performed since 2009 thanks to two parts. The first part will detail a new thermal approach implemented to improve nuclear heating measurements by radiometric calorimeters. New experimental tools (calorimeter prototypes and set-ups such BETHY Bench) developed to perform preliminary out-of-pile studies under suitable conditions will be presented (temperature and velocity of the external cooling fluid, heat source localization and intensity inside the calorimetric cells). Then the response of two kinds of sensors, their calibrations curves and their thermal behaviors will be compared for various parameters. Finally validated numerical thermal and Monte Carlo works will be discussed to propose new improvements. The second parts of the paper will focus on works realized in order to design, develop and test the first prototype of the multi-sensor device called CARMEN [7-9]. The two mock-ups dedicated respectively to neutron measurements and photon measurements will be detailed. The results obtained during two irradiation campaigns inside the periphery of OSIRIS reactor will be shown. The new analysis method will be discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Approach to Quality Assurance for Complex Environmental Modeling - 20407

A strong Quality Assurance (QA) program for complex environmental modeling is essential for regulatory and public acceptance and trust, but it does not have to be onerous. Neptune and Company, Inc. (Neptune) has developed a strong QA program that improves transparency, traceability, reproducibility, and therefore, defensibility and trust. Neptune's QA program has evolved over the past 27 years, transitioning from an ad hoc QA program, to a program that is currently Nuclear Quality Assurance-1 (NQA-1) compliant, and will soon be NQA-1/DOE approved for DOE EM modeling work. In addition, Neptune is a qualified laboratory assessor and qualified auditor for reference materials, a proficiency testing provider, and fully complies with the Environmental Protection Agency (EPA) QA program. Neptune's President and CEO, Kelly Black, was recently named the Chairperson of the International Organization for Standardization (ISO) Technical Committee 69, Application of Statistical Methods. A strong QA program has been developed for Neptune's radiological performance assessment (PA) program. Although pieces of their QA program are currently in development, their current program includes document control using Subversion, issue tracking and work flow tracking using JIRA, and transparency and traceability via a system of 'calc sheets' for documentation of all data analysis and modeling combined with 'check print' documentation of QA checking, and rigorous model testing and configuration control. All work is reviewed by an independent subject matter expert who is not associated with the collection and assembly of information, for an internal peer review. The program is enforced with a handful of Standard Operation Procedures (SOPs), Work Instructions, QA Project Plans (QAPPs), and Quality Management Plans (QMPs) that are updated frequently, with required annual training and acknowledgment. In addition, effective communication of modeling approaches and results to clients and stakeholders are integral to their QA program. Many of their models are built using the GoldSim modeling platform, for which their models are well-known for their level of transparency, documentation, and QA traceability. This level of QA is also applied to their process-level models. Neptune has taken some lessons learned from the extremely rigorous QA program required for the Yucca Mountain Project (YMP), and imposed the YMP requirements of complete traceability, transparency, and reproducibility, but avoided the inflexibility of a QA program that likely contributed to the suspect e-mails in 2005 that resulted in loss of trust in the YMP, and in nuclear waste disposal (and nuclear power) in general. There are far too many examples of loss of public trust due to poor QA that could have been easily avoided with a simple and straight-forward QA program combined with stakeholder engagement. The purpose of this paper is to share features of Neptune's Radiological Performance Assessment program QA program, and some of their QA related lessons learned over the past 27 years of QA for complex environmental modeling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Does administering iodine in radiological procedures increase patient doses?

Purpose: The authors investigated the changes in the pattern of energy deposition in tissue equivalent phantoms following the introduction of iodinated contrast media. Methods: The phantom consisted of a small “contrast sphere,” filled with water or iodinated contrast, located at the center of a 28 cm diameter water sphere. Monte Carlo simulations were performed using MCNP5 codes, validated by simulating irradiations with analytical solutions. Monoenergetic x-rays ranging from 35 to 150 keV were used to simulate exposures to spheres containing contrast agent with iodine concentrations ranging from 1 to 100 mg/ml. Relative values of energy imparted to the contrast sphere, as well as to the whole phantom, were calculated. Changes in patterns of energy deposition around the contrast sphere were also investigated. Results: Small contrast spheres can increase local absorbed dose by a factor of 13, but the corresponding increase in total energy absorbed was negligible (<1%). The highest localized dose increases were found to occur at incident photon energies of about 60 keV. For a concentration of about 10 mg/ml, typical of clinical practice, localized absorbed doses were generally increased by about a factor of two. At this concentration of 10 mg/ml, the maximum increase in total energy deposition in the phantom was only 6%. These simulations demonstrated that increases in contrast sphere doses were offset by corresponding dose reductions at distal and posterior locations. Conclusions: Adding iodine can result in values of localized absorbed dose increasing by more than an order of magnitude, but the total energy deposition is generally very modest (i.e., <10%). Their data show that adding iodine primarily changes the pattern of energy deposition in the irradiated region, rather than increasing patient doses per se.

60 APPLIED LIFE SCIENCES↗

Transarterial Chemoembolization With Cisplatin as Second-Line Treatment for Hepatocellular Carcinoma Unresponsive to Chemoembolization With Epirubicin-Lipiodol Emulsion

Purpose: The purpose of this retrospective study was to investigate the efficacy of transarterial chemoembolization (TACE) using cisplatin as a second-line treatment for advanced hepatocellular carcinoma (HCC) unresponsive to TACE using epirubicin-Lipiodol emulsion at our institution. Materials and Methods: Between January 2006 and March 2009, 51 patients with unresectable HCC underwent TACE using cisplatin. All patients had shown persistent viable tumor or tumor progression after at least 2 sessions of TACE using epirubicin-Lipiodol emulsion. TACE procedures consisted of arterial injection of a mixture of Lipiodol and cisplatin (30-100 mg [mean 57 {+-} 21]) (n = 29) or arterial infusion of cisplatin (30-100 mg [mean 87 {+-} 19]) solution (n = 22) followed by injection of 1-mm porous gelatin particles. Early tumor response was assessed by contrast-enhanced computed tomography (CT) according to Response Evaluation Criteria in Solid Tumors (RECIST) and European Association for the Study of the Liver (EASL) criteria. Overall survival and progression-free survival was calculated using the Kaplan-Meier method. Toxicity was assessed according to NCI-CTCAE version 3 criteria. Results: Response rates were 11.8 and 27.5% by RECIST and EASL criteria, respectively. Overall survival rates were 61.9, 48.2, and 28.9% at 1, 2, and 3 years, respectively, and the median survival time was 15.4 months. Progression-free survival rate was 35.2% at 1 year, and median progression-free survival time was 3.1 months. No major complications were observed, and the occurrence of postembolization syndrome was minimal. Grade 3 to 4 toxicities included thrombocytopenia (5.8%), increased aspartate aminotransferase (AST) level (35.3%), and increased alanine aminotransferase (ALT) level (23.5%). Conclusions: witching the TACE anticancer drug from epirubicin to cisplatin might be the feasible option for advanced HCC, even when considered resistant to the initial form of TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗