Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

The trigger and data acquisition for the NEMO-Phase 2 tower

In the framework of the Phase 2 of the NEMO neutrino telescope project, a tower with 32 optical modules is being operated since march 2013. A new scalable Trigger and Data Acquisition System (TriDAS) has been developed and extensively tested with the data from this tower. Adopting the all-data-to-shore concept, the NEMO TriDAS is optimized to deal with a continuous data-stream from off-shore to on-shore with a large bandwidth. The TriDAS consists of four computing layers: (i) data aggregation of isochronal hits from all optical modules; (ii) data filtering by means of concurrent trigger algorithms; (iii) composition of the filtered events into post-trigger files; (iv) persistent data storage. The TriDAS implementation is reported together with a review of dedicated on-line monitoring tools.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

The Zwicky Transient Facility: Surveys and Scheduler

Presented here is a novel algorithm for scheduling the observations of time-domain imaging surveys. Our integer linear programming approach optimizes an observing plan for an entire night by assigning targets to temporal blocks, enabling strict control of the number of exposures obtained per field and minimizing filter changes. A subsequent optimization step minimizes slew times between each observation. Our optimization metric self-consistently weights contributions from time-varying airmass, seeing, and sky brightness to maximize the transient discovery rate. We describe the implementation of this algorithm on the surveys of the Zwicky Transient Facility and present its on-sky performance.

79 ASTRONOMY AND ASTROPHYSICS↗

CHARACTERIZING THE ATMOSPHERES OF THE HR8799 PLANETS WITH HST/WFC3

We present results from a Hubble Space Telescope (HST) program characterizing the atmospheres of the outer two planets in the HR8799 system. The images were taken over 15 orbits in three near-infrared (near-IR) medium-band filters—F098M, F127M, and F139M—using the Wide Field Camera 3. One of the three filters is sensitive to a water absorption band inaccessible from ground-based observations, providing a unique probe of the thermal emission from the atmospheres of these young giant planets. The observations were taken at 30 different spacecraft rolls to enable angular differential imaging (ADI), and the full data set was analyzed with the Karhunen–Loéve Image Projection routine, an advanced image processing algorithm adapted to work with HST data. To achieve the required high contrast at subarcsecond resolution, we utilized the pointing accuracy of HST in combination with an improved pipeline designed to combine the dithered ADI data with an algorithm designed to both improve the image resolution and accurately measure the photometry. The results include F127M (J) detections of the outer planets, HR8799b and c, and the first detection of HR8799b in the water-band (F139M) filter. The F127M photometry for HR8799c agrees well with fitted atmospheric models, resolving the longstanding difficulty in consistently modeling the near-IR flux of the planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Measurement of a Low-Noise 64-Channels Front-End Readout ASIC for CdZnTe Detectors

Cadmium zinc telluride (CdZnTe) detectors, as one of the principal detectors for the next-generation X-ray and γ-ray imagers, have high energy resolution and supporting electrode patterning in the radiation environment at room-temperature. In the present, a number of internationally renowned research institutions and universities are actively using these detector systems to carry out researches of energy spectrum analysis, medical imaging, materials characterization, high-energy physics, nuclear plant monitoring, and astrophysics. As the most important part of the readout system for the CdZnTe detector, the front-end readout application specific integrated circuit (ASIC) would have an important impact on the performances of the whole detector system. In order to ensure the small signal to noise ratio (SNR) and sufficient range of the output signal, it is necessary to design a front-end readout ASIC with very low noise and very high dynamic range. In addition, radiation hardness should be considered when the detectors are utilized in the space applications and high energy physics experiments. In this paper, we present measurements and performances of a novel multi-channel radiation-hardness low-noise front-end readout ASIC for CdZnTe detectors. The readout circuits in each channel consist of charge sensitive amplifier, leakage current compensation circuit (LCC), CR-RC shaper, S-K filter, inverse proportional amplifier, peak detect and hold circuit (PDH), discriminator and trigger logic, time sequence control circuit and driving buffer. All of 64 readout channels' outputs enter corresponding inputs of a 64 channel multiplexer. The output of the mux goes directly out of the chip via the output buffer. The 64-channel readout ASIC is implemented using the TSMC 0.35 μm mixed-signal CMOS technology. The die size of the prototype chip is 2.7 mm x 8 mm. At room temperature, the equivalent noise level of a typical channel reaches 66 e{sup -} (rms) at zero farad for a power consumption of 8 mW per channel. The linearity error is lower than 1% and the overall gain of the readout channel is 165 V/pC. The crosstalk between the channels is less than 3%. By connecting the readout ASIC to a CdZnTe detector, we obtained a γ-ray spectrum, the energy resolution is 5.1% at the 59.5-keV line of {sup 241}Am source. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Speeding Up the Dissipating Energy Flow Based Oscillation Source Detection

This paper enhances the Dissipating Energy Flow (DEF) method for forced oscillation source detection. The development focuses on improving the speed of the DEF method for oscillation source detection employed by ISO-NE. This is accomplished by using multi-signal modal estimation and statistical correlation to achieve robustness and detection accuracy. The effectiveness of the proposed method is tested on simulated and actual oscillation data showing that detection and localization can be achieved with shorter data windows. In addition, the utilization of the DEF as an energy filter to minimize false alarm rates is examined. Finally, real PMU data is used to evaluate the consistency of the DEF method and track the actual direction the Dissipating Energy (DE) flows in the power network.

Kirihara, Kenta↗

Microfluidic Radiometal Labeling Systems for Biomolecules

In a typical labeling procedure with radiometals, such as Cu-64 and Ga-68; a very large (~ 100-fold) excess of the non-radioactive reactant (precursor) is used to promote rapid and efficient incorporation of the radioisotope into the PET imaging agent. In order to achieve high specific activities, careful control of reaction conditions and extensive chromatographic purifications are required in order to separate the labeled compounds from the cold precursors. Here we propose a microfluidic approach to overcome these problems, and achieve high specific activities in a more convenient, semi-automated fashion and faster time frame. Microfluidic reactors, consisting of a network of micron-sized channels (typical dimensions in the range 10 - 300¼m), filters, separation columns, electrodes and reaction loops/chambers etched onto a solid substrate, are now emerging as an extremely useful technology for the intensification and miniaturization of chemical processes. The ability to manipulate, process and analyze reagent concentrations and reaction interfaces in both space and time within the channel network of a microreactor provides the fine level of reaction control that is desirable in PET radiochemistry practice. These factors can bring radiometal labeling, specifically the preparation of radio-labeled biomolecules such as antibodies, much closer to their theoretical maximum specific activities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-consistent Color–Stellar Mass-to-light Ratio Relations for Low Surface Brightness Galaxies

The color–stellar mass-to-light ratio relation (CMLR) is a widely accepted tool for estimating the stellar mass (M {sub *}) of a galaxy. However, an individual CMLR tends to give distinct M {sub *} for a same galaxy when it is applied in different bands. Examining five representative CMLRs from the literature, we find that the difference in M {sub *} predicted in different bands from optical to near-infrared by a CMLR is 0.1 ∼ 0.3 dex. Based on a sample of low surface brightness galaxies that covers a wide range of color and luminosity, we therefore recalibrated each original CMLR in r, i, z, J, H, and K bands to give internally self-consistent M {sub *} for a same galaxy. The g–r is the primary color indicator in the recalibrated relations, which show little dependence on red (r–z) or near-infrared (J–K) colors. Additionally, the external discrepancies in the originally predicted γ {sub *} by the five independent CMLRs have been greatly reduced after recalibration, especially in the near-infrared bands, implying that the near-infrared luminosities are more robust in predicting γ {sub *}. For each CMLR, the recalibrated relations provided in this work could produce internally self-consistent M {sub *} from divergent photometric bands, and are extensions of the recalibrations from the Johnson–Cousin filter system by the pioneering work of McGaugh & Schombert to the filter system of the Sloan Digital Sky Survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Evaluation of a total energy-rate sensor on a transport airplane

A sensor that measures the rate of change of total energy of an airplane with respect to the airstream has been evaluated. The sensor consists of two cylindrical probes located on the fuselage of a transport airplane, an in line acoustic filter, and a pressure sensing altitude rate transducer. Sections of this report include the sensor description and experimental configuration, frequency response tests, analytical model development, and flight test results for several airplane maneuvers. The results section includes time history comparisons between data generated by the total energy rate sensor and calculated data derived from independent sources.

Ostroff, A. J.↗

Flame Imaging System

A system for imaging a flame and the background scene is discussed. The flame imaging system consists of two charge-coupled-device (CCD) cameras. One camera uses a 800 nm long pass filter which during overcast conditions blocks sufficient background light so the hydrogen flame is brighter than the background light, and the second CCD camera uses a 1100 nm long pass filter, which blocks the solar background in full sunshine conditions such that the hydrogen flame is brighter than the solar background. Two electronic viewfinders convert the signal from the cameras into a visible image. The operator can select the appropriate filtered camera to use depending on the current light conditions. In addition, a narrow band pass filtered InGaAs sensor at 1360 nm triggers an audible alarm and a flashing LED if the sensor detects a flame, providing additional flame detection so the operator does not overlook a small flame.

Barnes, Heidi L.↗

Is the X-ray Emission from the CTTS AZ Tau Accretion Driven?

The observations have been reduced and analyzed; unfortunately they were affected by very high background episodes, which have made it difficult to get a consistent sensitivity and fully achieve the original goals of the proposal. Nevertheless, after much experimenting with background filtering, etc., we believe we have converged on a good compromise and now expect to be able to recover a significant fraction of the observing time. Work on the part of our European collaborators is continuing and should result in a paper that could be ready for publication in the fall.

Mushotzky, Richard↗

Optical Sensing of Combustion Instabilities in Gas Turbines

In a continuing program of research and development, a system has been demonstrated that makes high-speed measurements of thermal infrared radiance from gas-turbine engine exhaust streams. When a gas-turbine engine is operated under conditions that minimize the emission of pollutants, there is a risk of crossing the boundary from stable to unstable combustion. Combustion instability can lead to engine damage and even catastrophic failure. Sensor systems of the type under development could provide valuable data during the development testing of gas-turbine engines or of engine components. A system of the type under development makes high-speed measurements of thermal infrared radiance from the engine exhaust stream. The sensors of this system can be mounted outside the engine, which eliminates the need for engine case penetrations typical with other engine dynamics monitors. This is an important advantage in that turbine-engine manufacturers consider such penetrations to be very undesirable. A prototype infrared sensor system has been built and demonstrated on a turbine engine. This system includes rugged and inexpensive near-infrared sensors and filters that select wavelengths of infrared radiation for high sensitivity. In experiments, low-frequency signatures were consistently observed in the detector outputs. Under some conditions, the signatures also included frequency components having one or two radiance cycles per engine revolution. Although it has yet to be verified, it is thought that the low-frequency signatures may be associated with bulk-mode combustion instabilities or flow instabilities in the compressor section of the engine, while the engine- revolution-related signatures may be indicative of mechanical problems in the engine. The system also demonstrated the ability to detect transient high-radiance events. These events indicate hot spots in the exhaust stream and were found to increase in frequency during engine acceleration.

Markham, James R.↗

Passive Neutron Non-Destructive Assay for Remediation of Radiological Waste at Hanford Burial Grounds- 13189

The Hanford burial grounds contains a broad spectrum of low activity radioactive wastes, transuranic (TRU) wastes, and hazardous wastes including fission products, byproduct material (thorium and uranium), plutonium and laboratory chemicals. A passive neutron non-destructive assay technique has been developed for characterization of shielded concreted drums exhumed from the burial grounds. This method facilitates the separation of low activity radiological waste containers from TRU waste containers exhumed from the burial grounds. Two identical total neutron counting systems have been deployed, each consisting of He-3 detectors surrounded by a polyethylene moderator. The counts are processed through a statistical filter that removes outliers in order to suppress cosmic spallation events and electronic noise. Upon completion of processing, a 'GO / NO GO' signal is provided to the operator based on a threshold level equivalent to 0.5 grams of weapons grade plutonium in the container being evaluated. This approach allows instantaneous decisions to be made on how to proceed with the waste. The counting systems have been set up using initial on-site measurements (neutron emitting standards loaded into surrogate waste containers) combined with Monte Carlo modeling techniques. The benefit of this approach is to allow the systems to extend their measurement ranges, in terms of applicable matrix types and container sizes, with minimal interruption to the operations at the burial grounds. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improved solution accuracy for Landsat-4 (TDRSS-user) orbit determination

This paper presents the results of a study to compare the orbit determination accuracy for a Tracking and Data Relay Satellite System (TDRSS) user spacecraft, Landsat-4, obtained using a Prototype Filter Smoother (PFS), with the accuracy of an established batch-least-squares system, the Goddard Trajectory Determination System (GTDS). The results of Landsat-4 orbit determination will provide useful experience for the Earth Observing System (EOS) series of satellites. The Landsat-4 ephemerides were estimated for the January 17-23, 1991, timeframe, during which intensive TDRSS tracking data for Landsat-4 were available. Independent assessments were made of the consistencies (overlap comparisons for the batch case and convariances for the sequential case) of solutions produced by the batch and sequential methods. The filtered and smoothed PFS orbit solutions were compared with the definitive GTDS orbit solutions for Landsat-4; the solution differences were generally less than 15 meters.

Oza, D. H.↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

Prediction of Gibbsite Precipitation for LAWPS and TSCR Processes at Hanford (U)

Determining the risk of precipitation of feed streams that could potentially lead to plugging ion exchange columns resulting in potential safety concerns and inefficient operation. Characterizing the feed to the filter at the Hanford site and compare it to the feed stream at SRS in ARP-MCU. Different precipitation distribution was observed for Hanford and SRS sites. Gibbsite precipitation is strongly affected by hydroxide concentration and temperature. High degrees of uncertainty of prediction of the exact amount of precipitate due to the extreme sensitivity of the waste solution to hydroxide fluctuations. Overall TSCR system consists of transferring supernate into an existing tank farm tank. Upon sampling and feed qualification, the supernate is sent into a dead-end filter to remove entrained solids, then is passed through an ion exchange column. The treated supernate will then be sent into another tank farm tank which will be used as the feed to the LAW vitrification facility. 250 + projected feed batches provided by Hanford: Reduced down to 65 batches; Projecting the feed vector from 2021-2054. Differences in Hanford and Savannah River waste feed stream compositions leading to dissimilar ionic interactions thus different precipitation distributions. Gibbsite: Dominating precipitate in Hanford waste (89 %). Sodium Oxalate: Predominant precipitate in SRS Waste (84 %). Based on the results, gibbsite precipitation is inversely affected by hydroxide concentration and temperature. Risk of precipitation is highly sensitive to hydroxide concentration and can vary significantly with slight fluctuations. All 65 batches showed distinct results with the range of [0.14, 1.25] Vol % and [0.28, 1.92] Mass % PPT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lightning mapper and the future

A trade-off analysis was completed that reveals how the lightning mapper detection efficiency will change as a function of interference filter bandwidth, pixel field of view, and telescope aperture. It is shown that the critical parameter on which we have minimum flexibility is filter band-width. The problem is that too narrow a filter bandwidth is incompatible with wide areal coverage. The trade-off analysis demonstrates that an 80 percent lightning detection efficiency will technically be relatively straight-forward, while a 90 percent detection efficiency will apparently be difficult to achieve. Three focal plane designs are currently under consideration. One would use a single large, solid state silicon integrating array with multiple output channels and off-the-focal-plane analog, time domain, background removing fibers. A second design would use the same technology, but the sensor would consist of up to four virtually independent focal plane arrays. This design reduces the areal coverage of each detector. Thus narrower interference filters could be utilized. Superior performance would be realized at a probable increase in cost. The final design would use a three-dimensional focal plane in order to perform background removal at the focal plane. Superior performance would be achieved along with reduced weight and power requirements. Unfortunately, this focal plane technology is still under development.

Christian, H. J.↗