Search NASA⌕ Search

SEARCH · Search NASA

Results for “density maps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

CHANGE OF MAGNETIC FIELD-GAS ALIGNMENT AT THE GRAVITY-DRIVEN ALFVÉNIC TRANSITION IN MOLECULAR CLOUDS: IMPLICATIONS FOR DUST POLARIZATION OBSERVATIONS

Diffuse striations in molecular clouds are preferentially aligned with local magnetic fields, whereas dense filaments tend to be perpendicular to them. When and why this transition occurs remain uncertain. To explore the physics behind this transition, we compute the histogram of relative orientation (HRO) between the density gradient and the magnetic field in three-dimensional magnetohydrodynamic (MHD) simulations of prestellar core formation in shock-compressed regions within giant molecular clouds. We find that, in the magnetically dominated (sub-Alfvénic) post-shock region, the gas structure is preferentially aligned with the local magnetic field. For overdense sub-regions with super-Alfvénic gas, their elongation becomes preferentially perpendicular to the local magnetic field. The transition occurs when self-gravitating gas gains enough kinetic energy from the gravitational acceleration to overcome the magnetic support against the cross-field contraction, which results in a power-law increase of the field strength with density. Similar results can be drawn from HROs in projected two-dimensional maps with integrated column densities and synthetic polarized dust emission. We quantitatively analyze our simulated polarization properties, and interpret the reduced polarization fraction at high column densities as the result of increased distortion of magnetic field directions in trans- or super-Alfvénic gas. Furthermore, we introduce measures of the inclination and tangledness of the magnetic field along the line of sight as the controlling factors of the polarization fraction. Observations of the polarization fraction and angle dispersion can therefore be utilized in studying local magnetic field morphology in star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-122: The CBCT Dose Calculation Using a Patient Specific CBCT Number to Mass Density Conversion Curve Based On a Novel Image Registration and Organ Mapping Method in Head-And-Neck Radiation Therapy

Purpose: To develop a CBCT HU correction method using a patient specific HU to mass density conversion curve based on a novel image registration and organ mapping method for head-and-neck radiation therapy. Methods: There are three steps to generate a patient specific CBCT HU to mass density conversion curve. First, we developed a novel robust image registration method based on sparseness analysis to register the planning CT (PCT) and the CBCT. Second, a novel organ mapping method was developed to transfer the organs at risk (OAR) contours from the PCT to the CBCT and corresponding mean HU values of each OAR were measured in both the PCT and CBCT volumes. Third, a set of PCT and CBCT HU to mass density conversion curves were created based on the mean HU values of OARs and the corresponding mass density of the OAR in the PCT. Then, we compared our proposed conversion curve with the traditional Catphan phantom based CBCT HU to mass density calibration curve. Both curves were input into the treatment planning system (TPS) for dose calculation. Last, the PTV and OAR doses, DVH and dose distributions of CBCT plans are compared to the original treatment plan. Results: One head-and-neck cases which contained a pair of PCT and CBCT was used. The dose differences between the PCT and CBCT plans using the proposed method are −1.33% for the mean PTV, 0.06% for PTV D95%, and −0.56% for the left neck. The dose differences between plans of PCT and CBCT corrected using the CATPhan based method are −4.39% for mean PTV, 4.07% for PTV D95%, and −2.01% for the left neck. Conclusion: The proposed CBCT HU correction method achieves better agreement with the original treatment plan compared to the traditional CATPhan based calibration method.

60 APPLIED LIFE SCIENCES↗

Evaluation of a Laser-Dot Grid-Projection System for Lunar Lander Crater-Shape and Ejecta-Sheet Measurements

Development, testing, and evaluation of an active-illumination laser-dot grid-projection system was performed to evaluate its potential inclusion on an upcoming uncrewed lunar lander mission to the south pole region of the moon. Active illumination may be required for this mission due to the shallow angle of the sun at the landing location, which may cast shadows in the landing region, hindering the stereo camera imaging system’s ability to determine the pre-and post-landing lunar surface/crater shape. Testing includes characterization of the diffractive optical elements used for the grid projection, single-camera tests to determine the imaged laser dot intensity as a function of camera exposure and imaging angle relative to the laser grid projection, laser dot brightness/saturation impact on depth map calculations, angle of imaged laser grid impact on depth map calculations for steep crater edges, impact of density gradients on the depth map calculations, and the feasibility of making measurements of the ejecta sheet.

Joshua M. Weisberger↗

Formation of Supported Graphene Oxide: Evidence for Enolate Species

Graphene oxides are promising materials for novel electronic devices or anchoring of the active sites for catalytic applications. Here we focus on understanding the oxygen binding on different regions of graphene (Gr) on Ru(0001). Differences in the Gr/Ru lattices result in the superstructure, which offers an array of distinct adsorption sites. We employ scanning tunneling microscopy and density functional theory to map out the chemical identity and stability of prepared oxygen functionalities in different Gr regions. We demonstrate that in the regions that are close to the metal substrate, the terminally-bonded enolate groups are strongly preferred over bridge-bonded epoxy configurations. No oxygen species are observed on the graphene regions that are far from the underlying Ru, indicating their low relative stability. This study provides a clear fundamental basis for understanding the structural and electronic factors that affect the stability of enolate and epoxy species as a function of Gr/Ru interactions.

Supported Graphene, Graphene Functionalization, Gr↗

Measurement of pulsed-power-driven magnetic fields via proton deflectometry

Measuring magnetic field and current distribution in Z-pinch plasma systems is crucial to the validation of Z-pinch theory. In this letter, the demonstration of proton deflectometry to pulsed-power-driven loads at the mega-amp scale is presented, which is capable of making more detailed field maps in high-density regions of plasmas. In this method, a laser-driven, broad-spectrum, MeV-energy proton beam is directed through a pulsed-power-driven plasma system, and the resulting deflections are measured to examine configuration of magnetic fields and to infer the currents that support them. The technique was first demonstrated on simple short-circuit loads, and the results are in excellent agreement with numerical simulations providing reliable estimates of the field and current configurations. It was then applied to a more complex—radial foil—plasma load. The measurements show unexpected proton deflections that exhibit the complexity of the plasma load and that with further analysis will reveal details about the current and magnetic field topology in this complex configuration.

Mariscal, D.↗

X-Ray Emitting Ejecta in Puppis A Observed with Suzaku

We report the detection and localization of X-ray emitting ejecta in the middle-aged Galactic supernova remnant Puppis A using five observations with the Suzaku X-ray Imaging Spectrometer to survey the eastern and middle portions of the remnant. A roughly 3' x 5', double-peaked region in the north center is found to be highly enriched in Si and other elements relative to the rest of the remnant. The X-ray fitted abundances are otherwise well below the solar values. While the ejecta-enhanced regions show some variation of relative element abundances, there is little evidence for a very strong enhancement of one element over the others in the imaged portion of the remnant, except possibly for a region of 0 and Ne enhancement in the remnant's south center. There is no spatial correlation between the compact [0 1111 emitting ejecta knots seen optically and the abundance enhancements seen in X-rays, although they are located in the same vicinity. The map of fitted column density shows strong variations across the remnant that echo earlier X-ray spectral hardness maps. The ionization age (as fitted for single temperature models) is sharply higher in a ridge behind the northeast-east boundary of the remnant, and is probably related to the strong molecular cloud interaction along that boundary. The temperature map, by comparison, shows relatively weak variations.

Hwang, U.↗

Venus gravity - A high-resolution map

The Doppler data from the radio tracking of the Pioneer Venus Orbiter (PVO) have been used in a two-stage analysis to develop a high-resolution map of the gravitational potential of Venus, represented by a central mass and a surface mass density. The two-stage procedure invokes a Kalman filter-smoother to determine the orbit of the spacecraft, and a stabilized linear inverter to estimate the surface mass density. The resultant gravity map is highly correlated with the topographic map derived from the PVO radar altimeter data. However, the magnitudes of the gravity variations are smaller than would be expected if the topography were uncompensated, indicating that at least partial compensation has taken place.

Reasenberg, R. D.↗

Examination of ionic wind and cathode sheath effects in a E-field premixed flame with ion density measurements

The effect of the ionic wind on a premixed methane-air flame under a DC electric field is studied via mapping of the ion density with Langmuir probes. Ion densities were observed to increase near the burner with increasing electrode voltage up to 6 kV. Past this electrode supply voltage, ion densities ceased increasing and began to decline in some locations within the premixed flame. The increased ion density is caused by an increase in ionic wind force and cathode sheath thickness. The plateau in density is due to the cathode sheath fully encompassing the flame front which is the ion source, thereby collecting all ions in the flame. The spatial density data support the ionic wind hypothesis and provide further explanation of its limits based on the plasma sheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupling the core analysis program DeCART to the fuel performance application BISON

The 3D neutron transport and core analysis program DeCART was coupled to the fuels performance application BISON to provide a higher fidelity tool for fuel performance simulation. This project is motivated by the desire to couple a high fidelity core analysis program (based on the method of characteristics) to a high fidelity fuel performance program, both of which can simulate 3D problems. DeCART provides sub-pin level resolution of the multigroup neutron flux, with resonance treatment, during burnup or a fast transient. BISON implicitly solves coupled thermomechanical equations for the fuel on a sub-millimeter level finite element mesh. A method was developed for mapping the fission rate density and fast neutron flux from DeCART to BISON. Multiple depletion cases were run with one-way data transfer from DeCART to BISON. The one-way data transfer of fission rate density is shown to agree with the fission rate density obtained from an internal Lassman-style model in BISON. One-way data transfer was also demonstrated in a 3D case in which azimuthal asymmetry was induced in the fission rate density profile of a fuel rod modeled in DeCART. Two-way data transfer was established by mapping the temperature distribution from BISON to DeCART. A Picard iterative algorithm was developed for the loose coupling with two-way data transfer. (authors)

97 MATHEMATICS AND COMPUTING↗

Electron Density Changes across the Pressure-Induced Iron Spin Transition

High-pressure single-crystal x-ray diffraction is used to experimentally map the electron-density distribution changes in (Fe,Mg)O as ferrous iron undergoes a pressure-induced transition from high- to low-spin states. As the bulk density and elasticity of magnesiowustite—one of the dominant mineral phases of Earth’s mantle—are affected by this electronic transition, our results have applications to geophysics as well as to validating first-principles calculations. Furthermore, the observed changes in diffraction intensities indicate a spin-transition-induced change in orbital occupancies of the Fe ion in general accord with crystal-field theory, illustrating the use of electron density measurements for characterizing high-pressure d-block chemistry and motivating further studies characterizing chemical bonding under pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining an unknown state of a high-dimensional quantum system with a single, factorized observable

One can uniquely identify an unknown state of a quantum system S by measuring a ''quorum'' consisting of a complete set of noncommuting observables. It is also possible to determine the quantum state by repeated measurements of a single and factorized observable, when the system S is coupled to an assistant system A whose initial state is known. This is because that the redistribution of the information about the unknown quantum state into the composite system A+S results in a one-to-one mapping between the unknown density matrix elements and the probabilities of the occurrence of the eigenvalues of a single, factorized observable of the composite system. Here we focus on quantum state tomography of high-dimensional quantum systems (e.g., a spin greater than 1/2) via a single observable. We determine the condition for the best determination and the upper bound to achieve the most robust measurements. From the experimental view we require a suitable interaction Hamiltonian to maximize the measure efficiency. For this we numerically investigate a three-level system. Moreover, the error analysis for the different-dimensional quantum states shows that the present measurement method is still very effective in determining an unknown state of a high-dimensional quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze the images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).

60 APPLIED LIFE SCIENCES↗

Geomorphology and reflectance patterns of vegetation-covered dunes at the Tsodilo Hills, north-west Botswana

Seasonal reflectance variations in semigrid environments provide a means of assessing vegetation health and density as well as monitoring landform processes. Multitemporal Landsat Thematic Mapper scenes with field measurements are used to map geomorphology and vegetation density in a stabilized dune environment and to measure seasonal reflectance changes for a series of ten geomorphological and vegetation units on the Kalahari-age linear dunes. Units were chosen based on differences in landform and proportion of trees, forbs and bare soil. Reflectance curves and normalized-difference vegetation indices (NDVI) show that dune crests have the strongest seasonal variability in color and brightness. The geomorphological link with reflectance and NDVI values are linked to biomass production and zoning of vegetation with slope, drainage and subtle soil differences.

Jacobberger, P. A.↗

Detecting deviations from Gaussianity in high-redshift CMB lensing maps

ABSTRACT While the probability density function of the cosmic microwave background (CMB) convergence field approximately follows a Gaussian distribution, primordial non-Gaussianities, and small contributions from structures at low redshifts make the overall distribution slightly non-Gaussian. Some of the late-time component can be modelled using the distribution of galaxies and subtracted off from the original CMB lensing map to produce a map of matter distribution at high redshifts. Using this high-redshift mass map, we are able to directly study the early phases of structure formation. In this work, we forecast the detectability of signatures of non-Gaussianity due to non-linear structure formation at z > 1.2. Assuming the optimal case of no systematics, we find that it is challenging to detect such signatures in current surveys, but future experiments such as the deep field of CMB-S4 will be able to make detections of ∼7σ.

Astronomy & Astrophysics↗

Nanoscale temperature mapping in operating microelectronic devices

We report that modern microelectronic devices have nanoscale features that dissipate power nonuniformly, but fundamental physical limits frustrate efforts to detect the resulting temperature gradients. Contact thermometers disturb the temperature of a small system, while radiation thermometers struggle to beat the diffraction limit. Exploiting the same physics as Fahrenheit’s glass-bulb thermometer, we mapped the thermal expansion of Joule-heated, 80-nanometer-thick aluminum wires by precisely measuring changes in density. With a scanning transmission electron microscope (STEM) and electron energy loss spectroscopy (EELS), we quantified the local density via the energy of aluminum’s bulk plasmon. Rescaling density to temperature yields maps with a statistical precision of 3 kelvin/hertz ₋1/2 , an accuracy of 10%, and nanometer-scale resolution. Lastly, many common metals and semiconductors have sufficiently sharp plasmon resonances to serve as their own thermometers.

47 OTHER INSTRUMENTATION↗

Time-resolved x-ray radiography of spark ignition plasma

Understanding the short-lived structure of the plasma that forms between the electrodes of a spark plug is crucial to the development of improved ignition models for SI engines. However, measuring the amount of energy deposited in the gas directly and non-intrusively is difficult, due to the short time scales and small length scales involved. The breakdown of the spark gap occurs at nanosecond time scales, followed by an arc phase lasting a few microseconds. Finally, a glow discharge phase occurs over several milliseconds. It is during the arc and glow discharge phases that most of the heat transfer from the plasma to the electrodes and combustion gases occurs. Light emission can be used to measure an average temperature, but micron spatial resolution is required to make localized measurements. In this paper, we present the results of a proof of concept experiment that demonstrates the use of time-resolved x-ray radiography to measure the density of the plasma in the spark gap during the glow discharge phase of a conventional transistorized coil ignition system. A focused monochromatic x-ray beam from the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory was used to make time-resolved point measurements of the projected density, which decreases as the plasma temperature increases. Multiple measurement positions were combined to produce a two-dimensional map of the projected density both inside and surrounding the spark gap. A temporal resolution of 153 ns and spatial resolution of 5 μm were achieved. A range of ambient gases, densities (1 - 3 bar) and ignition coil charging durations (1 - 2.5 ms) were considered. At least 30 repeated measurements were made for each sample point and condition. All these parameters were found to substantially alter the structure of the plasma as measured by x-ray radiography. From the projected density measurements, changes in thermal energy can be calculated. These provide a quantitative measurement of the energy deposited into the gas; this is only a small fraction of the total spark energy. The measurements demonstrate the feasibility of time-resolved x-ray radiography for the study of plasma structure and development for SI applications.

Kastengren, Alan L.↗

Mapping the stellar backbones of spiral galaxies

We present optical and IR surface photometry of M51 (NGC 5194) at B, V, R, I, J, K, and CO. These data are used to establish whether K-band images of spiral galaxies provide reliable maps of stellar surface mass density features such as massive spiral arms or bars. The main distorting agents in the mapping at shorter wavelengths are dust extinction and luminous young stars. From modeling the color changes across the main dust lanes in M51, we find the optical depths to be about 0.5 in the K band. For these optical depths the K-band flux is attenuated by only less than 10 percent even in the dust lanes. From monitoring the gravity-sensitive CO index across the spiral arms we find that young red supergiants do not significantly distort the K-band image. On this basis, we conclude that K-band images do trace the massive disk star population and allow to map azimuthal variation in the surface mass density of the stellar disk. In M51 we find the surface mass density contrast to range from 1.8 to 3, as expected from N-body simulations of the galaxy's tidal encounter with NGC 5195. The spiral arm amplitude in M51 clearly shows smooth, strong radial variations, with a maximum at about 130 arcsec and minima at 45 and 170 arcsec.

Rix, Hans-Walter↗