Search NASA⌕ Search

SEARCH · Search NASA

Results for “deployed optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evaluating Combined Lidar and Polarimeter Measurements of Cloud Top Parameters (Extinction, Scattering Cross Sections, and Droplet Number Density, Liquid Water Content)

We present a new method to derive profiles of extinction from a lidar which is then combined with polarimeter measurements to derive cloud droplet number density (CDNC) in the tops of warm clouds. The method employs polarization-sensitive elastic backscatter lidar measurements to estimate attenuation of the lidar signal within the cloud and polarimeter estimates of cloud droplet size distributions. The measurements used for this demonstration are from NASA Langley Research Center’s High Spectral Resolution Lidar – Generation 2 (HSRL-2) and NASA GISS’s Research Scanning Polarimeter (RSP). The measurements were acquired on NASA’s ACTIVATE mission, during which the instruments were deployed in a down-looking mode from a high-altitude aircraft, which flew in coordination with a low-flying aircraft acquiring coincident in situ measurements of cloud droplet size and number. The high vertical (1.25 m) and horizontal (~50 m) sampling resolution of the HSRL-2 data enabled retrievals of single-scattering extinction profiles to within ~2.5 optical depths of cloud top. Another key feature of the method was the well-calibrated measurement of backscatter at cloud top due to using the HSRL technique. The RSP retrievals of cloud droplet effective radius and variance were accomplished using the “cloud-bow” technique. Overall, the technique provides extinction profile estimates for the top 2.5 optical depths of water clouds that can be used to estimate the cloud droplet number density in various types of warm clouds. The mean extinction values at cloud top (0-1 optical depth) are compared against cloud drop size and number concentration acquired from wing-mounted probes (e.g., DMT Cloud Droplet Probe - CDP, SPEC Fast Cloud Droplet Probe FCDP, and SPEC 2D Stereo Probe - 2DS) that were deployed on the low-flying aircraft. Comparisons between the effective radius and variance from the polarimeter, lidar ratio (extinction to backscatter) from the lidar and polarimeter, and LWC are also presented. All measurements were acquired over the Western North Atlantic over 3 years from 2020 to 2022.

lidar↗

Optical characterization of the on-target OMEGA focal spot at high energy using the full-beam in-tank diagnostic

The full-beam in-tank (FBIT) diagnostic has been deployed to directly measure the target-plane beam fluence profile, when operated at high energy, of the OMEGA Laser System at the University of Rochester’s Laboratory for Laser Energetics. This article presents the results of early measurements taken with this diagnostic and discusses an improvement that has overcome performance limitations discovered during the initial testing. The diagnostic gives new insight into the ability of the OMEGA Laser System to provide uniform fluence profiles that are consistent across all 60 beams in the laser. Overall, the ultimate goal of the FBIT diagnostic is to allow accurate assessment of the fluence uniformity on a spherical target in 60-beam implosion experiments

47 OTHER INSTRUMENTATION↗

Optical Characterization of CLPS MiniatureLaser Retroreflector Arrays

Laser retroreflector arrays (LRAs) consisting of corner cube retroreflectors (CCRs) can act as fiducial markers for decades of laser ranging on the Moon and other planetary bodies. Upcoming lunar lander missions from government space agencies and commercial partners offer a unique opportunity to support lunar science and exploration through the deployment of small LRAs on lander decks. Placement of an LRA on the deck of a lander or rover enables tracking with an orbital laser altimeter to aprecision on the order of centimeters. When mounted alongside a suite of scientific instruments the LRA enables precise geolocation of those instruments in the lunar geodetic frame. Finally, optical markers such as LRAs can support precision autonomous navigation and landing regardless of lighting conditions, an especially valuable capability for lunar polar exploration where long shadows complicate terrain relative nagivation using imaging methods.

Daniel R. Cremons↗

Using AI for Wave-front Estimation with the Rubin Observatory Active Optics System

Abstract The Vera C. Rubin Observatory will, over a period of 10 yr, repeatedly survey the southern sky. To ensure that images generated by Rubin meet the quality requirements for precision science, the observatory will use an active-optics system (AOS) to correct for alignment and mirror surface perturbations introduced by gravity and temperature gradients in the optical system. To accomplish this, Rubin will use out-of-focus images from sensors located at the edge of the focal plane to learn and correct for perturbations to the wave front. We have designed and integrated a deep-learning (DL) model for wave-front estimation into the AOS pipeline. In this paper, we compare the performance of this DL approach to Rubin’s baseline algorithm when applied to images from two different simulations of the Rubin optical system. We show the DL approach is faster and more accurate, achieving the atmospheric error floor both for high-quality images and low-quality images with heavy blending and vignetting. Compared to the baseline algorithm, the DL model is 40× faster, the median error 2× better under ideal conditions, 5× better in the presence of vignetting by the Rubin camera, and 14× better in the presence of blending in crowded fields. In addition, the DL model surpasses the required optical quality in simulations of the AOS closed loop. This system promises to increase the survey area useful for precision science by up to 8%. We discuss how this system might be deployed when commissioning and operating Rubin.

79 ASTRONOMY AND ASTROPHYSICS↗

Clock Synchronization Characterization of the Washington DC Metropolitan Area Quantum Network (DC-QNet)

Quantum networking protocols relying on interference and precise time-of-flight measurements require high-precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. With active electronic stabilization, sub-picosecond time deviation (TDEV) was achieved at integration times between 1 s and 10 5 s over 53 km of deployed fiber. Over the same integration periods, 10-picosecond level TDEV was observed using the White Rabbit-Precision Time Protocol (WR-PTP) over 128 km. Measurement methods are described to understand the sources of environmental fluctuations on clock synchronization towards the development of in-situ compensation methods. Path delay gradients, chromatic dispersion, polarization drift, and optical power variations all contributed to clock synchronization errors. The results from this study will inform future work in the development of link noise management methods essential for enabling experimental research in developing practical quantum networking protocols.

PIKTime↗

Durability of polymeric encapsulation materials in a PMMA/glass concentrator photovoltaic system

We examined the durability of polymeric encapsulation materials using outdoor exposure at the nominal geometric concentration of 500 suns. The results for 36-month cumulative field deployment are presented for materials including: poly(ethylene-co-vinyl acetate), (EVA); polyvinyl butyral (PVB); ionomer; polyethylene/polyoctene copolymer (PO); thermoplastic polyurethane (TPU); poly(dimethylsiloxane) (PDMS); poly(diphenyl dimethyl siloxane) (PDPDMS); and poly(phenyl-methyl siloxane) (PPMS). Measurements of the field conditions including ambient temperature and ultraviolet (UV) dose were recorded at the test site during the experiment. Our measurements for the experiment included optical transmittance (with subsequent analysis of solar-weighted transmittance, UV cut-off wavelength, and yellowness index), mass, visual photography, photoelastic imaging, and fluorescence spectroscopy. While the results to date for EVA are presented and discussed, examination here focuses more on the siloxane materials. A specimen recently observed to fail by thermal decomposition is discussed in terms of the implementation of the experiment as well as its fluorescence signature, which was observed to become more pronounced with age. Modulated thermogravimetry (allowing determination of the activation energy of thermal decomposition) was performed on a subset of the siloxanes to quantify the propensity for decomposition at elevated temperatures. Supplemental, Pt-catalyst- and primer-solutions as well as peroxide-cured PDMS specimens were examined to assess the source of the luminescence. Furthermore, our results, including the change in optical transmittance, observed failure modes, and subsequent analyses of the failure modes are described in the conclusions.

14 SOLAR ENERGY↗

Using optical fibers to examine thermal mixing of liquid sodium in a pool-type geometry

Sodium fast reactors (SFR) are poised to be a leading candidate for the next generation of commercial nuclear reactor deployment. Companies are commissioning designs for SFR increasing the need for experimental and computational analysis to improve the economics and safety of these reactors. Analysis of SFR behavior during reactor transients directly informs the understanding of reactor safety. Particularly, investigating the thermal transients associated with the reactor loss of flow transient allows for informed design decisions to be made regarding reactor safety. During loss of flow transients the flow rate of the coolant is significantly reduced, but not necessarily stopped. The reduction in flow rate results in coolant temperatures exiting the reactor core that can be drastically different than the coolant in upper pool. When these different temperature fluids interact, thermally stratified layers can form causing cyclic thermal fatigue on the reactor vessel potentially leading to pre-material failure. Past experimental studies have lacked high resolution temperature measurements. This research focuses on demonstrating the reliability of novel techniques for acquiring high resolution temperature measurements in a scaled liquid sodium facility. Tests are conducted that simulate postulated loss of flow transients and provide unprecedented spatial temperature distribution measurements.

42 ENGINEERING↗

First results of the KM3NeT multi-PMT DOM

The future KM3NeT neutrino telescope will consist of several thousand digital optical modules (DOMs), each of which will be equipped with 31 3-inch photo-multiplier tubes (PMTs). This design has various advantages over the use of one large PMT per optical module, e.g. concerning effective photocathode area per module, improved background suppression and directional reconstruction. Currently, the KM3NeT collaboration is testing a prototype DOM deployed on the instrumentation line of the ANTARES neutrino telescope. The DOM has been operational since mid-April 2013. First data are presented and compared to simulation results. The results are very encouraging and indicate that muon identification and a coarse direction estimation are possible event with a single DOM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrino Physics with SNO+

SNO+ is a neutrino experiment with a broad physics program, the primary goal being a search for the phenomenon of neutrinoless double beta decay, a process possible only if the neutrino is its own antiparticle, or a "Majorana" fermion. Such a discovery would substantially alter our understanding of particle physics, including introducing the need for a non-Higgs mechanism for generating particle mass, and place constraints on the as-yet-unknown neutrino mass scale. SNO+ will also detect neutrinos from the solar core, furthering our understanding of the fusion cycles that power the sun, and antineutrinos produced inside the Earth (geoneutrinos), which will enable a better understanding of heat production beneath the Earth's surface. We will continually monitor for neutrinos from nearby supernovae, which, if detected, could allow us to better understand the role of neutrinos in stellar core collapse, and potentially to determine the unknown neutrino mass hierarchy. With such a broad physics program, SNO+ has great potential both to advance our understanding of neutrinos, and to use neutrinos to understand the formation and behavior of our Universe. This report describes a targeted plan of optical calibrations of the SNO+ detector, with the goal of measuring and monitoring the PMT optical response independently of liquid scintillator properties. To this end we describe the design, construction, and operation of a source of Cherenkov light for deployment in SNO+. Successful deployment in the initial light water phase is described, demonstrating the capabilities of this calibration mechanism. The results of this work form a critical input to the SNO+ detector model, directly impacting the sensitivity of all SNO+ physics results. Also described is significant work on detector commissioning, DAQ and operations, the implementation of calibration efforts in multiple physics analyses, involvement in all levels of analysis activities, and leadership in SNO+ science.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ORNL Portable Diagnostic Package for Evaluating Mirror Performance

Oak Ridge National Laboratory (ORNL) and Realta Fusion successfully executed a one-year collaborative effort to deploy the Portable Diagnostic Package (PDP) on the Wisconsin HTS Axisymmetric Mirror (WHAM) and to assess future diagnostic needs. The PDP consists of an optical emission spectroscopy (OES) subsystem and a Thomson scattering (TS) subsystem. Within the first two months, the PDP OES subsystem was installed, integrated with WHAM timing, and handed over to trained Realta personnel. It immediately delivered multi-channel impurity surveys and the first spatially resolved plasma-rotation profiles inferred from C III Doppler shifts. The TS subsystem was commissioned within the first six months; transportation of the class IV laser system, approval of the safety plan, and the integration with WHAM timing with 100 ns resolution. The TS subsystem provided the first localized electron temperature measurements in WHAM commissioning shots. Leveraging these results, the team has discussed a diagnostic concept map for Realta’s next-step facility, Anvil, identifying line-of-sight constraints, required temporal resolution, and hardware upgrades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of the Sunset Semi-Continuous Carbon Aerosol Analyzer

Accurate quantification of carbonaceous aerosols is essential for reducing uncertainty in climate change models and is important for long-term air quality monitoring by government agencies. The field-deployable Sunset Semi-Continuous Organic Carbon/Elemental Carbon Aerosol Analyzer (Sunset OCEC) utilizes a modified National Institute for Occupational Safety and Health thermal-optical method to determine total carbon (TC), organic carbon (OC), and elemental carbon (EC) at near real-time; however, its performance is not yet fully characterized. Two collocated Sunset OCEC Analyzers, Unit A and Unit B, were used to determine the relative standard deviation (RSD) and limit of detection (LOD) between June 23 and July 9, 2007, in Richland, Washington, USA. A high-efficiency particulate air filter was utilized to determine the LODs of both instruments. The RSDs between the two Sunset OCECs were 9.12% for TC, 13.0% for Optical OC, and 8.97% for Thermal OC, indicating good precision between the instruments, although the RSDs for Thermal and Optical EC were higher, 29.0% and 48.3%, respectively. The LOD of Unit A was approximately 0.21 µgC/m3 for TC, Optical OC, and Thermal OC, and ~0.004 µgC/m3 for Optical and Thermal EC. Similarly, Unit B had an LOD of ~0.29 µgC/m3 for TC, Optical OC, and Thermal OC, 0.018 µgC/m3 for Optical EC, and 0.004 µgC/m3 for Thermal EC. Factors that may have contributed to the poor RSDs of Thermal and Optical EC include the low EC mass loading in Richland, minor leakage in the oxygen valve of Unit B, and excessive noise from the non-dispersive infrared (NDIR) laser in Unit B, resulting in scattered Optical EC measurements. Improved RSDs of all OC and EC parameters are expected after the Unit B NDIR is tuned up. Future work should reevaluate the precision of the Sunset OCECs and investigate the differences in various thermal-optical protocols on OCEC quantification.

54 ENVIRONMENTAL SCIENCES↗

CAPS PMssa Aerosol Extinction and SSA Data

We collected rapid (1 second time response) measurements of aerosol extinction and scattering (Mm-1) using an Aerodyne CAPS PMssa deployed during LASIC (as part of the LASIC SSA-constraint study) to measure ambient SSA at 530 nm wavelength to compare with other optical measurement methods. Measured from August 4 to September 22, 2017. Sampled from both PM1 and PM10 inlets. CAPS PMssa monitors have been tested extensively for PM2.5 and smaller particle sizes, but not for particles greater than 2,500 nm in diameter (i.e., PM10). The data were collected in order to provide an independent measurement of aerosol single scattering albedo at 530 nm wavelength to compare with ARM standard methods.

54 ENVIRONMENTAL SCIENCES↗

Four lunar astronomical observatories - Concepts developed in the NASA 90-day study for the Human Exploration Initiative

A number of astrophysical observatory concepts were studied under the overall direction of the NASA Astrophysics Division in support of NASA's 90-day study of the Human Exploration Initiative. The four observatory concepts described here were investigated at JPL. In three of them, interferometric techniques would be used to acquire high resolution synthetic aperture images in several different parts of the electromagnetic spectrum: in the UV/visible near infrared; the submillimeter; and the very low frequency (1 to 30 MHz region). The fourth is a gravitational wave detector which uses laser optical interferometry to measure the strains induced by the passage of a gravitational wave. The observatory concepts reflect the constraints on lunar surface science deployment anticipated for the Human Exploration Initiative in the period 2002 through 2015.

Cutts, James A.↗

Raman Spectroscopy as a Method for Mineral Identification on Lunar Robotic Exploration Missions

The sharp, nonoverlapping Raman bands for plagioclase, pyroxene, and olivine would be advantageous for on-surface, active mineralogical analysis of lunar materials. A robust, light-weight, low-power, rover-based Raman spectrometer with a laser exciting source, entirely transmission-mode holographic optics, and a charge-coupled device (CCD) detector could fit within a less than 20 cm cube. A sensor head on the end of an optical fiber bundle that carried the laser beam and returned the scattered radiation could be placed against surfaces at any desired angle by a deployment mechanism; otherwise, the instrument would need no moving parts. A modem micro-Raman spectrometer with its beam broadened (to expand the spot to 50-micrometer diameter) and set for low resolution (7/cm in the 100-1400/cm region relative to 514.5-nm excitation), was used to simulate the spectra anticipated from a rover instrument. We present spectra for lunar mineral grains, less than 1 mm soil fines, breccia fragments, and glasses. From frequencies of olivine peaks, we derived sufficiently precise forsterite contents to correlate the analyzed grains to known rock types and we obtained appropriate forsterite contents from weak signals above background in soil fines and breccias. Peak positions of pyroxenes were sufficiently well determined to distinguish among orthorhombic, monoclinic, and triclinic (pyroxenoid) structures; additional information can be obtained from pyroxene spectra, but requires further laboratory calibration. Plagioclase provided sharp peaks in soil fines and most breccias even when the glass content was high.

Wang, Alian↗

Study of the Variability in the Rain Drop Size Distribution Over a 2.3. km Path

In an effort to study the drop size distribution (DSD) a state-of-the-art instrument arrangement was deployed on Wallops Island, VA. The instrumentation consisted of a 2.3-km multi-frequency microwave link, three impact disdrometers, and a network of optical and tipping bucket raingauges. A dual-frequency inversion technique was implemented with the fink measurements of attenuations at 25 GHz and 38 GHz to estimate the path-average DSD. Concurrently, an X-band, dual-polarization radar, located in the vicinity, collected polarization and reflectively measurements over the link path. The evaluation of the estimates and measurements generated some preliminary results.

Rincon, Rafael F.↗

Maritime Aerosol Network as a Component of AERONET - First Results and Comparison with Global Aerosol Models and Satellite Retrievals

The Maritime Aerosol Network (MAN) has been collecting data over the oceans since November 2006. Over 80 cruises were completed through early 2010 with deployments continuing. Measurement areas included various parts of the Atlantic Ocean, the Northern and Southern Pacific Ocean, the South Indian Ocean, the Southern Ocean, the Arctic Ocean and inland seas. MAN deploys Microtops handheld sunphotometers and utilizes a calibration procedure and data processing traceable to AERONET. Data collection included areas that previously had no aerosol optical depth (AOD) coverage at all, particularly vast areas of the Southern Ocean. The MAN data archive provides a valuable resource for aerosol studies in maritime environments. In the current paper we present results of AOD measurements over the oceans, and make a comparison with satellite AOD retrievals and model simulations.

Smirnov, A.↗

TPSAS-NF1676L-26989-DND

The NASA Langley Research Center airborne High Spectral Resolution Lidar (HSRL-2) provided extensive measurements of smoke above shallow marine clouds while deployed from the NASAER-2 aircraft during the NASAEV-S Observations of Aerosols above Clouds and their Interactions (ORACLES) mission. During the first ORACLES field campaign in September 2016, the ER-2 was deployed from Walvis Bay, Namibia and conducted flights over the south eastern Atlantic Ocean. HSRL-2 measured profiles of aerosol backscattering, extinction and aerosol optical depth (AOD) at 355 and 532 nm and aerosol backscattering and depolarization at 1064 nm and so provided an excellent characterization of the wide-spread smoke layers above shallow marine clouds. We use the HSRL-2 measurements to examine retrievals of AOD above clouds retrieved from A Train active (CALIOP) and passive (OMI, MODIS) sensors. We also present profiles of aerosol microphysical properties such as concentration and effective radius that are derived from the HSRL-2 multi wavelength measurements of backscatter and extinction.

Richard Ferrare↗