Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS

Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount of bremsstrahlung radiation is significantly decreased.

43 PARTICLE ACCELERATORS↗

Mass, height of burst, and source–receiver distance constraints on the acoustic coda phase delay method

Here, this research uses the acoustic coda phase delay method to estimate relative changes in air temperature between explosions with varying event masses and heights of burst. It also places a bound on source–receiver distance for the method. Previous studies used events with different shapes, height of bursts, and masses and recorded the acoustic codas at source–receiver distances less than 1 km. This research further explores the method using explosions that differ in mass (by up to an order of magnitude) and are placed at varying heights. Source–receiver distances also cover an area out to 7 km. Relative air temperature change estimates are compared to complementary meteorological observations. Results show that two explosions that differ by an order of magnitude cannot be used with this method because their propagation times in the near field and their fundamental frequencies are different. These differences are expressed as inaccuracies in the relative air temperature change estimates. An order of magnitude difference in mass is also shown to bias estimates higher. Small differences in height of burst do not affect the accuracy of the method. Finally, an upper bound of 1 km on source–receiver distance is provided based on the standard deviation characteristics of the estimates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Identification and repair of intermittent cable faults in nuclear power plants - 131

The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Driven dynamic mode-splitting of the magnetic vortex translational resonance.

A magnetic vortex in a restricted geometry possesses a nondegenerate translational excitation that corresponds to circular motion of its core at a characteristic frequency. For 40-nm thick, micron-sized permalloy elements, we find that the translational-mode microwave absorption peak splits into two peaks that differ in frequency by up to 25% as the driving field is increased. An analysis of micromagnetic equations shows that for large driving fields two stable solutions emerge.

36 MATERIALS SCIENCE↗

Self-Powered Autonomous Sensing System for Arctic Ocean using a Frequency-multiplied Cylindrical Triboelectric Nanogenerator

An autonomous sensing system for collecting environmental observations in the Arctic region is critical for the estimation and prediction of climate change. Ocean waves are a great source of energy for these sensing systems but there has been limited research done on small-scale energy harvesting applications in the Arctic Ocean (subsea or surface). The available wave energy in the Arctic Ocean is lower than the typical ocean wave energy due to the low wave frequency, height, and operating months. Although the available wave energy depends on the specific location in the Arctic Ocean, the wave height decreases everywhere during the winter (Jan-March) [1]. Our target location in this work is the Beaufort and Chukchi Seas, which are ice covered for about 195 days per year leaving only a few months (June-November) for wave energy harvesting [2]. During these few months, the average wave frequency is 0.2 Hz and the most common wave frequency is around 0.15 Hz. Many energy harvesting methods are unsuitable for use in the Arctic Ocean because of to the cold temperature, low wave frequency, and low wave height. Triboelectric nanogenerators (TENG) are one of the few energy harvesting methods that excel in these conditions. Zhong et al. [3] designed a stacked pendulum-structured TENG for low-frequency ocean wave energy and reported the device generated a peak power density of 11.2 W/m3 under the low wave frequency of 0.2 Hz. The autonomous sensing system we developed for the Arctic Ocean, the Arctic-TENG, is based on a frequency-multiplied cylindrical TENG (FMC-TENG) which is an optimized TENG configuration for Arctic Ocean conditions due to the high power density under low-frequency wave conditions [4]. Figure 1 shows an FMC-TENG with multiple pairs of free-standing triboelectric-layer mode materials (Aluminum and FEP). The mass and magnet attached to the rotor store gravitational potential energy which is released as kinetic energy when the potential energy overcomes the repulsive magnetic force generated by the opposing magnet attached to the stator. This force unbalance triggers a sudden rotation and swinging motion of the mass which increases the angular velocity of the system and therefore enhances the output power of the TENG system. The main components of the Arctic-TENG are a 3D-printed rotor and stator, electric and dielectric material adhesive tape, and bearings. All these materials were cold-soaked and tested at -40 °C in a chest freezer. Both the 3D-printed parts and adhesives were confirmed to have a minimal effect from the cold temperature. Multiple bearings were tested and the starting torque of each one was compared both at room temperature and -40 °C. The bearing with the lowest starting torque at -40 °C was selected for use in the Arctic-TENG. The Arctic-TENG was tested using an out-of-water motor-driven wave simulator (Figure 2). The wave simulator allows for controlled testing at a wave height of 0.2 m and frequencies between 0.1 Hz to 0.5 Hz. This wave simulator was used for both room temperature and -40 °C testing. The Arctic-TENG generated significantly more power at -40 °C compared to room temperature for each frequency tested. The system stored energy in a supercapacitor via a power management circuit, and the amount of energy stored per day was calculated at different wave frequencies. Based on the conditions at the proposed deployment location (days of non-ice-covered ocean and wave frequency), the amount of stored energy per year from Arctic-TENG was calculated to be enough energy for two transmissions every day. Durability testing was completed on the Arctic-TENG at room temperature to determine the lifetime. The rotor of the Arctic-TENG was attached to a DC motor and spun continuously for several millions of cycles without degradation of the electrical output, demonstrating the feasibility for long-term operation.

Jung, Hyunjun↗

Generation of arbitrary frequency-entangled states of two-photon light

We consider a new method for the generation of polarization-frequency entangled states of photon pairs. We use a frequency-nondegenerate regime of spontaneous parametric down conversion where the photon pairs (biphotons) are produced with identical polarizations, propagate mostly in the same direction, but differ in frequency. Entanglement is achieved by a coherent superposition of pairs emitted from two nonlinear crystals, with the polarization of the biphotons from the first crystal being changed by a transformer placed between the two crystals. We show that this scheme allows the degree of entanglement to be controlled by the choice of biphoton frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasistationary resonances induced by intense infrared fields in HD{sup +} and their decay

The nature of a few low-lying laser-induced resonances of HD{sup +} along with their linewidths due to dissociation, has been investigated in the intensity range of (1-6) x10{sup 13}W/cm{sup 2} for three different laser frequencies. In the length gauge representation of the interaction Hamiltonian used by us, these resonances for the lower intensities are basically the vibrational states of the unperturbed molecule, shifted and broadened by radiative interactions. At higher intensities the resonances are obtained as quasistationary states on different adiabatic potentials. They are formed by the mixing of various unperturbed vibrational states by multiphoton interactions. In this mixing, the proportion of vibrational states further away from the resonance energy increases with the increase in intensity. At high enough intensities, signature of dissociation through a nonresonant intermediate vibrational transition to the v=6 and v=7 state is observed for a laser frequency of 12 500 cm{sup -1}. The width of the lowest resonance increases sharply with intensity, while its shift from the v=0 state increases only linearly with intensity. The branching ratios to different photon absorption channels change with intensity and they can be interpreted using the adiabatic potential curves. For a frequency of 2000 cm{sup -1}, which is close to the frequency of v=0 to v=1 transition, the resonances arise from the mixing of various vibrational levels through stepwise transitions, resulting in a dissociation linewidth larger compared to that obtained for higher frequencies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ways and peculiarities of submillimeter wavelength detection with short-channel field-effect transistors

The detection properties of some short-channel field-effect transistors (FETs) have been analyzed using the steady-state output characteristics of these devices. The calculated dependences of voltage-power sensitivity on applied voltage are compared with the corresponding curves obtained from high-frequency measurements. It is shown that the nonmonotonic dependence of the FET photosensitivity on gate voltage that is observed in the frequency range of 400-750 GHz is not related to resonant excitation of 2D plasmons in the subgate plasma but is due to the change in the distribution of stationary fields in the structure and, as a result, to the change in the efficiency of nonresonant nonlinearity procedures in the transistor's electron subsystem with an increase in the gate-channel voltage. This conclusion is confirmed by analysis of the frequency dependences of photoresponse in the range under consideration, which do not exhibit resonant behavior at the frequencies corresponding to the peaks in the curves measured at a fixed frequency and different gate voltages.

36 MATERIALS SCIENCE↗

Advances in Optical Mixing Techniques for the Effective Control of Parametric Instabilities in Laser-Produced Plasmas

We discovered new ways of suppressing SRS and 2ω p which are based on electron plasma waves (EPW), by introducing an appropriate KEEN wave at half the EPW frequency and at the same wavevector. This new mechanism does not allow nonlinearly trapped EPWs to survive so that they phase mix and disappear. We also thoroughly studied KEEN waves at different amplitude, frequency and wavenumber drives in order to see where they may be most strongly driven and discovered that a phase velocity of 2 seems to engender the largest response for all wavevectors, k, even though the harmonic content is very different for low k (very elastic plasma response, many (5-7) large harmonics) vs high k (stiff, one or two harmonics at best).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms: Preprint

Floating offshore wind turbines have several advantages over their land-based counterparts, including access to stronger, more consistent winds and proximity to population centers. However, increased costs from the platform have been a challenge inhibiting their widespread adoption. New damping technologies with tunable target frequencies and damping ratios promise a greater degree of control over platform motions, allowing hulls to be designed smaller and reducing the overall cost of the turbines. In this work, a control strategy is proposed for these adjustable tuned mass dampers (TMDs). A frequency-domain model of the system is developed, from which response amplitude operators (RAOs) for the platform's rigid-body modes can be obtained for different natural frequencies and damping ratios of the dampers. Using these RAOs, and JONSWAP spectrums of operational and extreme sea states, the performance of the various damper settings are compared by evaluating the standard deviation of a rigid-body motion of interest (platform pitch or heave). By finding the optimal damper setting for a range of representative design load cases (DLCs), a lookup function is made to return the damper target frequency given the peak period of the sea state. To determine the current sea state, we propose a simple estimator that uses wave measurements (e.g., from a measurement buoy) to determine the peak period and significant wave height. The significant wave height is determined using the statistics of the past 100 seconds of wave elevation information and the peak period is computed using a frequency locked loop. Initial results show that we can use these estimated values to control the TMD natural frequency with an open loop controller. The controlled system is tested in a range of environmental conditions determined by the International Electrotechnical Commission design load cases (DLCs), which include normal and extreme wind and wave models. In these tests, we compare the performance of 4 cases: (1) no TMD, (2) a constant TMD based on the worst case DLC, (3) a controlled TMD based on known wind and wave environments, and (4) a real-time controlled TMD using estimated wind and wave environments. The effect of hull-based TMD control is also compared to changes in traditional wind turbine control via blade pitch.

control↗

Biophysical control of the growth of Agrobacterium tumefaciens using extremely low frequency electromagnetic waves at resonance frequency

Isolated Agrobacterium tumefaciens was exposed to different extremely low frequencies of square amplitude modulated waves (QAMW) from two generators to determine the resonance frequency that causes growth inhibition. The carrier was 10 MHz sine wave with amplitude ±10 Vpp which was modulated by a second wave generator with a modulation depth of ± 2Vpp and constant field strength of 200 V/m at 28 °C. The exposure of A. tumefaciens to 1.0 Hz QAMW for 90 min inhibited the bacterial growth by 49.2%. In addition, the tested antibiotics became more effective against A. tumefaciens after the exposure. Furthermore, results of DNA, dielectric relaxation and TEM showed highly significant molecular and morphological changes due to the exposure to 1.0 Hz QAMW for 90 min. An in-vivo study has been carried out on healthy tomato plants to test the pathogenicity of A. tumefaciens before and after the exposure to QAMW at the inhibiting frequency. Symptoms of crown gall and all pathological symptoms were more aggressive in tomato plants treated with non-exposed bacteria, comparing with those treated with exposed bacteria. We concluded that, the exposure of A. tumefaciens to 1.0 Hz QAMW for 90 min modified its cellular activity and DNA structure, which inhibited the growth and affected the microbe pathogenicity.

60 APPLIED LIFE SCIENCES↗

Defect density and dielectric constant in perovskite solar cells

We report on measurement of dielectric constant, mid-gap defect density, Urbach energy of tail states in CH{sub 3}NH{sub 3}PbI{sub x}Cl{sub 1−x} perovskite solar cells. Midgap defect densities were estimated by measuring capacitance vs. frequency at different temperatures and show two peaks, one at 0.66 eV below the conduction band and one at 0.24 eV below the conduction band. The attempt to escape frequency is in the range of 2 × 10{sup 11}/s. Quantum efficiency data indicate a bandgap of 1.58 eV. Urbach energies of valence and conduction band are estimated to be ∼16 and ∼18 meV. Measurement of saturation capacitance indicates that the relative dielectric constant is ∼18.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic probe diagnostics of nonlinear standing waves and bulk ohmic electron power absorption in capacitive discharges

It is recognized that standing wave effects appearing in large-area, very-high-frequency capacitively coupled plasma (CCP) reactors cause center-high plasma non-uniformity. Using a high-frequency magnetic probe, we present a direct experimental diagnostic of the nonlinear standing waves and bulk ohmic electron power absorption dynamics in low pressure CCP discharges for different driving frequencies of 13.56, 30, and 60 MHz. The design, principle, calibration, and validation of the probe are described in detail. Spatial structures of the harmonics of the magnetic field, determined by the magnetic probe, were used to calculate the distributions of the harmonic current and the corresponding ohmic electron power deposition, providing insights into the behavior of nonlinear harmonics. At a low driving frequency, i.e. 13.56 MHz, no remarkable nonlinear standing waves were identified and the bulk ohmic electron power absorption was observed to be negligible. Here, the harmonic magnetic field/current was found to increase dramatically with the driving frequency, due to decreased sheath reactance and more remarkable nonlinear standing waves at a higher driving frequency, leading to the enhancements of the ohmic heating and the plasma density in the bulk, specifically at the electrode center. At a high driving frequency, i.e. 60 MHz, the high-order harmonic current density and the corresponding ohmic electron power absorption exhibited a similar node structure, with the main peak on axis, and one or more minor peaks between the electrode center and the edge, contributing to the center-high profile of the plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA

Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<10 3 km 2 ) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990–2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as “true loads”. Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. Furthermore, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.

54 ENVIRONMENTAL SCIENCES↗

Optically pumped, radio-frequency atomic magnetometry with feedback stabilization

An optically pumped, atomic magnetometer incorporates a feedback system for stabilizing the magnetic bias field and suppressing unwanted background fields. The magnetic bias field is applied to a vapor cell containing host atoms of two different species, each of which resonates at a different Larmor frequency when both are subjected to the same magnetic bias field. One species provides the feedback for stabilizing the bias field, thereby creating a stabilizing magnetometer portion that nulls out the unwanted background fields. The other species provides magnetic field detection or signal reception on a radio communication frequency of interest, thereby creating a signal magnetometer portion that permits detection of the signal at the radio communication frequency.

Schwindt, Peter D. D.↗

Cardinal: Seismic and Geoacoustic Array Processing

Data collected via seismic and infrasound array deployments are leveraged in the geosciences to detect and characterize a myriad of natural and anthropogenic sources. These deployments consist of numerous sensors placed in a predetermined configuration to amplify signal strength and improve the efficacy of array processing techniques used to measure signal directionality and waveform coherence. High‐fidelity feature extraction is often predicated on interstation distance as well as the frequency content and wavelength of an incident signal. Numerous array processing softwares analyze data in sequential frequency bands to obtain a more detailed characterization of a signal. However, current algorithms are limited in their ability to determine optimal array configuration for each band. We introduce an open‐source Python code, called Cardinal, to process seismic and infrasound array data in discretized time–frequency space with the option of applying an adaptive array design to determine optimal subarray configuration for each frequency band. To reduce computational time, the array processing step can be run in parallel using multithreading. Furthermore, the software has the capability to aggregate array processing results from different time–frequency pixels to produce separate sets of detections, or families, with added utility via the application of an adaptive semblance threshold, which aids in isolating signals‐of‐interest from coherent background noise. Upon appropriate configuration, Cardinal exhibits the potential to combine distinct seismic and infrasound phases into separate families.

Adaptive Array↗