Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Performance comparison for Barnes model 12-1000, Exotech model 100, and Ideas Inc. Biometer Mark 2

Results of tests show that all channels of all instruments, except channel 3 of the Biometer Mark 2, were stable in response to input signals were linear, and were adequately stable in response to temperature changes. The Biometer Mark 2 is labelled with an inappropriate description of the units measured and the dynamic range is a inappropriate for field measurements causing unnecessarily high fractional errors. This instrument is, therefore, quantization limited. The dynamic range and noise performance of the Model 12-1000 are appropriate for remote sensing field research. The field of view and performance of the Model 100A and the Model 12-1000 are satisfactory. The Biometer Mark 2 has not, as yet, been satisfactorily equipped with an acceptable field of view determining device. Neither the widely used aperture plate nor the 24 deg cone are acceptable.

Robinson, B.↗

SU-F-T-384: Step and Shoot IMRT, VMAT and Autoplan VMAT Nasopharnyx Plan Robustness to Linear Accelerator Delivery Errors

Purpose: To identify the robustness of different treatment techniques in respect to simulated linac errors on the dose distribution to the target volume and organs at risk for step and shoot IMRT (ssIMRT), VMAT and Autoplan generated VMAT nasopharynx plans. Methods: A nasopharynx patient dataset was retrospectively replanned with three different techniques: 7 beam ssIMRT, one arc manual generated VMAT and one arc automatically generated VMAT. Treatment simulated uncertainties: gantry, collimator, MLC field size and MLC shifts, were introduced into these plans at increments of 5,2,1,−1,−2 and −5 (degrees or mm) and recalculated in Pinnacle. The mean and maximum doses were calculated for the high dose PTV, parotids, brainstem, and spinal cord and then compared to the original baseline plan. Results: Simulated gantry angle errors have <1% effect on the PTV, ssIMRT is most sensitive. The small collimator errors (±1 and ±2 degrees) impacted the mean PTV dose by <2% for all techniques, however for the ±5 degree errors mean target varied by up to 7% for the Autoplan VMAT and 10% for the max dose to the spinal cord and brain stem, seen in all techniques. The simulated MLC shifts introduced the largest errors for the Autoplan VMAT, with the larger MLC modulation presumably being the cause. The most critical error observed, was the MLC field size error, where even small errors of 1 mm, caused significant changes to both the PTV and the OAR. The ssIMRT is the least sensitive and the Autoplan the most sensitive, with target errors of up to 20% over and under dosages observed. Conclusion: For a nasopharynx patient the plan robustness observed is highest for the ssIMRT plan and lowest for the Autoplan generated VMAT plan. This could be caused by the more complex MLC modulation seen for the VMAT plans. This project is supported by a grant from NSW Cancer Council.

60 APPLIED LIFE SCIENCES↗

Calibration of EBT2 film using a red-channel PDD method in combination with a modified three-channel technique

Purpose: Ashland Inc. EBT2 and EBT3 films are widely used in quality assurance for radiation therapy; however, there remains a relatively high degree of uncertainty [B. Hartmann, M. Martisikova, and O. Jakel, “Homogeneity of Gafchromic EBT2 film,” Med. Phys. 37, 1753–1756 (2010)]. Micke et al. (2011) recently improved the spatial homogeneity using all color channels of a flatbed scanner; however, van Hoof et al. (2012) pointed out that the corrected nonuniformity still requires further investigation for larger fields. To reduce the calibration errors and the uncertainty, the authors propose a new red-channel percentage-depth-dose method in combination with a modified three-channel technique. Methods: For the ease of comparison, the EBT2 film image used in the authors’ previous study (2012) was reanalyzed using different approaches. Photon beams of 6-MV were delivered to two different films at two different beam on times, resulting in the absorption doses of ranging from approximately 30 to 300 cGy at the vertical midline of the film, which was set to be coincident with the central axis of the beam. The film was tightly sandwiched in a 30{sup 3}-cm{sup 3} polystyrene phantom, and the pixel values for red, green, and blue channels were extracted from 234 points on the central axis of the beam and compared with the corresponding depth doses. The film was first calibrated using the multichannel method proposed by Micke et al. (2010), accounting for nonuniformities in the scanner. After eliminating the scanner and dose-independent nonuniformities, the film was recalibrated via the dose-dependent optical density of the red channel and fitted to a power function. This calibration was verified via comparisons of the dose profiles extracted from the films, where three were exposed to a 60° physical wedge field and three were exposed to composite fields, and all of which were measured in a water phantom. A correction for optical attenuation was implemented, and treatment plans of intensity modulated radiation therapy and volumetric modulated arc therapy were evaluated. Results: The method described here demonstrated improved accuracy with reduced uncertainty. The relative error compared with the measurements of a water phantom was less than 1%, and the overall calibration uncertainty was less than 2%. Verification tests revealed that the results were close to those of the authors’ previous study, and all differences were within 3%, except those with a high-dose gradient. The gamma pass rates (2%/2 mm) of the treatment plan evaluated using the method described here were greater than 99%, and no obvious stripe patterns were observed in the dose-difference maps. Conclusions: Spatial homogeneity was significantly improved via the calibration method described here. This technique is both convenient and time-efficient because it does not require cutting the film, and only two exposures are necessary.

60 APPLIED LIFE SCIENCES↗

Using a Commercial Ethernet PHY Device in a Radiation Environment

This work involved placing a commercial Ethernet PHY on its own power boundary, with limited current supply, and providing detection methods to determine when the device is not operating and when it needs either a reset or power-cycle. The device must be radiation-tested and free of destructive latchup errors. The commercial Ethernet PHY's own power boundary must be supplied by a current-limited power regulator that must have an enable (for power cycling), and its maximum power output must not exceed the PHY's input requirements, thus preventing damage to the device. A regulator with configurable output limits and short-circuit protection (such as the RHFL4913, rad hard positive voltage regulator family) is ideal. This will prevent a catastrophic failure due to radiation (such as a short between the commercial device's power and ground) from taking down the board's main power. Logic provided on the board will detect errors in the PHY. An FPGA (field-programmable gate array) with embedded Ethernet MAC (Media Access Control) will work well. The error detection includes monitoring the PHY's interrupt line, and the status of the Ethernet's switched power. When the PHY is determined to be non-functional, the logic device resets the PHY, which will often clear radiation induced errors. If this doesn't work, the logic device power-cycles the FPGA by toggling the regulator's enable input. This should clear almost all radiation induced errors provided the device is not latched up.

Parks, Jeremy↗

Circulation from a joint gravity field solution determination of the general ocean

With the development of satellite altimetry, it is possible to infer the geostrophic velocity of the surface ocean currents, if the geoid and the position of the satellite are known accurately. Errors in current geoid models and orbit computations, both due primarily to errors in the earth's gravity field model, have limited the use of altimeter data for this purpose. The objective of this investigation is to demonstrate that altimeter data can be used in a joint solution to simultaneously estimate the quasi-stationary sea surface topography, zeta, and the model for the gravity field. Satellite tracking data from twelve satellites were used along with Seasat altimeter data for the solution. The estimated model of zeta compares well at long wavelengths with the hydrographic model of zeta. Covariance analysis indicates that the geoid is separable from zeta up to degree 9, at which point geoid error is comparable to the signal of zeta.

Tapley, B. D.↗

SU-E-T-506: Intercomparison Study On Small Field Output Factor Measurements

Purpose In radiotherapy, uncertainties due to small field measurements (SFM) introduce systematic errors to the treatment process and the development of new dosimeters for quality assurance programs is a challenge. In this work we analyze the behavior of seven detectors measuring output factors of 6MV photon beam. Methods The dosimeters employed are: a single cristal diamond detector (SCCD) developed at the University of Rome Tor Vergata, a silicon diode developed within the project MAESTRO, a IBA Razor silicon diode, A1SL and A26 Exradin ion chambers, an EBT3 Gafchromic film and the Exradin W1 Scintillator.Diamond sensitive volume is a cylinder 2.2mm in diameter and 1μm thick. MAESTRO diode is 2×2mm2 active area. Razor sensitive volume is a cylinder 0.6 mm in diameter and 0.02 mm thick. A16 and A1Sl have a collecting volume of 0,015cc and 0,053cc. The W1 is an optical fiber with an active volume of 0.002cc. All measurements were performed in a water phantom, with detector positioned at the isocenter (SSD=90cm, d=10cm), MAESTRO diode being sandwiched in solid water to obtain an equivalent experimental setup. Results These measurements are challenging due to the absence of charged particle equilibrium conditions, detector size and positioning problems. They are in good agreement among each other, especially GAF, Razor, W1 and SCDD. Maximum deviations reported are related to the field 0.8×0.8cm2 for MAESTRO and chambers data with respect to EBT3: around 15% (A1SLvsEBT3), 16% (MAESTROvsEBT3). Razor and W1 show a deviation around 3% with respect to SCDD. Conclusion In this work measurements made with a variety of detectors are compared. These study show the possibility to choose different detectors for SFM and that smaller ion chambers are still not competitive with solid state detectors. Silicon, diamond and optical fiber dosimeters show a similar behavior with minor discrepancies for the smallest field.

60 APPLIED LIFE SCIENCES↗

Storm Surge Modeling in Puget Sound

In this study, a storm surge model of the Salish Sea was developed to simulate storm surge in Puget Sound using the unstructured-grid, finite-volume community ocean model (FVCOM). The model was based on Pacific Northwest National Laboratory’s existing Puget Sound hydrodynamic model that has been validated extensively in previous studies. To identify representative historical storm events, a systematic approach was developed based on the non-tidal residual (NTR) method. A total of 34 storm surge events between 1980 and 2016 were identified and simulated. To accurately simulate storm surge inside Puget Sound, the model was driven by reanalyzed Climate Forecast System Reanalysis meteorological forcing and observed water levels at the entrance of Strait of Juan de Fuca and southern entrance of Johnstone Strait. Model results for total water level, storm surge, and currents were compared with field measurements. A series of error statistics parameters were also calculated to quantify the model’s skills in simulating storm surge in the Salish Sea. Error statistics of model performance metrics demonstrated that the Salish Sea storm surge model was able to simulate storm surge inside Puget Sound with high accuracy. Storm surge propagation into Puget Sound is a nonlinear process that cannot be simply determined by a static approach for the entire domain. The maximum NTR distribution inside Puget Sound suggests that storm surge tends to be amplified in several sub-basins and inlets of the Puget Sound, such as Bellingham Bay, Hood Canal, south Puget Sound, and the multi-inlet basin behind Agate and Rich Passages. Therefore, future study is necessary to further quantify the storm surge level in these high-risk areas through field measurements and refined model simulations.

16 TIDAL AND WAVE POWER↗

SU-E-T-263: Development of Dose Monitor Unit Calculation Using Clarkson Integration for Proton Beam Therapy Using Beam-Wobbling System

Purpose: The purpose of the present study is to develop a calculation method of dose-calibration-factor using Clarkson integration for proton therapy employing the wobbling system and to evaluate accuracy of the calculation by comparison between calculations and measurements. Methods: CF and CALF stand for a dose-calibration-factor and a dose per monitor unit (MU), respectively. A measured dose-calibration-factor CFmeas is defined as a ratio of the measured dose per monitor unit in a patient-specific condition CALFpat to the measured dose per MU in a reference beam condition CALFref. The CFcalc is a product of three factors: CF1, CF2 and CF3. The CF1 and CF2 are a factor reflecting the effect of common beam delivery devices and that of patient specific devices and parameter (an aperture collimator, a range compensator and an air gap), respectively. The CF1 was obtained by interpolation using measured data. The CF2 was calculated using the Simplified Monte Carlo (SMC) method. The SMC method calculates a dose distribution by tracing individual protons and by using a measured Bragg curve in water. The CF3 representing the correction factor of field size effect was obtained by using the Clarkson integration. We compared the calculated and measured CF values for 20 prostate cases. Results: Field size correction was found to be important. The calculations reproduce the measurement results within an error of ±2.0%, except for a few cases. The error was about –3.1% for the small field area of less than19 square centimeters. Conclusion: We have developed a calculation method of dose-calibration-factor. Calculations agreed with measurements within ±2.0% for 90% of 20 prostate cases. Except for a small field size cases, the calculation method can be applied to determine the dose-calibration–factor for majority cases of prostate cancer.

60 APPLIED LIFE SCIENCES↗

Coherent lidar design and performance verification

The verification of LAWS beam alignment in space can be achieved by a measurement of heterodyne efficiency using the surface return. The crucial element is a direct detection signal that can be identified for each surface return. This should be satisfied for LAWS but will not be satisfied for descoped LAWS. The performance of algorithms for velocity estimation can be described with two basic parameters: the number of coherently detected photo-electrons per estimate and the number of independent signal samples per estimate. The average error of spectral domain velocity estimation algorithms are bounded by a new periodogram Cramer-Rao Bound. Comparison of the periodogram CRB with the exact CRB indicates a factor of two improvement in velocity accuracy is possible using non-spectral domain estimators. This improvement has been demonstrated with a maximum-likelihood estimator. The comparison of velocity estimation algorithms for 2 and 10 micron coherent lidar was performed by assuming all the system design parameters are fixed and the signal statistics are dominated by a 1 m/s rms wind fluctuation over the range gate. The beam alignment requirements for 2 micron are much more severe than for a 10 micron lidar. The effects of the random backscattered field on estimating the alignment error is a major problem for space based lidar operation, especially if the heterodyne efficiency cannot be estimated. For LAWS, the biggest science payoff would result from a short transmitted pulse, on the order of 0.5 microseconds instead of 3 microseconds. The numerically errors for simulation of laser propagation in the atmosphere have been determined as a joint project with the University of California, San Diego. Useful scaling laws were obtained for Kolmogorov atmospheric refractive turbulence and an atmospheric refractive turbulence characterized with an inner scale. This permits verification of the simulation procedure which is essential for the evaluation of the effects of refractive turbulence on coherent Doppler lidar systems. The analysis of 2 micron Doppler lidar data from Coherent Technologies, Inc. (CTI) has demonstrated many of the advantages of doppler lidar measurements of boundary layer winds. The effects of wind shear and wind turbulence over the pulse volume are probably the dominant source of the reduced performance. The effects of wind shear and wind turbulence on the statistical description of doppler lidar data has been derived and calculated.

Frehlich, Rod↗

Evolution of the Kondo lattice electronic structure above the transport coherence temperature

Significance The temperature ( T )-dependent evolution of the Kondo lattice electronic structure is a long-standing topic of theoretical and experimental investigation, still lacking a truly microscopic theory that agrees with a full experimental characterization. Here multiple characteristic T scales of the interaction of localized f moments with conduction electrons in the Kondo lattice CeCo I n 5 are identified and investigated using angle-resolved photoemission measurements that substantiate dynamical mean-field theory which newly includes the full realism of crystalline electric-field (CEF) f splittings. Thereby errors in the itinerant versus localized f -state classification from standard density functional theory are corrected, microscopic insight into the broad T -range crossover of f -hybridization effects is gained, and a prediction of CEF degeneracy crossover below the lattice coherence T is made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GPS-based orbit determination and point positioning under selective availability

Selective availability (SA) degrades the positioning accuracy for nondifferential users of the GPS Standard Positioning Service (SPS). The often quoted SPS accuracy available under normal conditions is 100 m 2DRMS. In the absence of more specific information, many prospective SPS users adopt the 100 m value in their planning, which exaggerates the error in many cases. SA error is examined for point positioning and dynamic orbit determination for an orbiting user. To minimize SA error, nondifferential users have several options: expand their field of view; observe as many GPS satellites as possible; smooth the error over time; and employ precise GPS ephemerides computed independently, as by NASA and the NGS, rather than the broadcast ephemeris. Simulations show that 3D point position error can be kept to 30 m, and this can be smoothed to 3 m in a few hours.

Bar-Sever, Yoaz E.↗

High Order Filter Methods for Shock/Turbulence MHD Flows

Low-dissipative high order filter finite difference methods for shock/turbulence/combustion compressible viscous MHD flows has been constructed. Several variants of the filter approach that cater to different flow types are proposed. These filters provide a natural and efficient way for the minimization of the divergence of the magnetic field (del (raided dot) B) numerical error in the sense that no standard divergence cleaning is required. For certain 2-D MHD test problems, divergence free preservation of the magnetic fields of these filter schemes has been achieved.

Yee, H. C.↗

High Accuracy Coronagraph Flight Model For WFIRST–CGI Raw Contrast Sensitivity Analysis

A high-accuracy high-fidelity flight wavefront control (WFC) model is developed for detailed raw contrast sensitivity analysis of WFIRST-CGI. Built upon features of recently testbed validated model, it is further refined to combine a full Fresnel propagation diffraction model for high accuracy contrast truth evaluation, and an economical compact model for WFC purposes. Extensive individual raw contrast error sensitivities are evaluated systematically, both as known imperfections and as unknown calibration errors, for both spectroscopy mode and wide field-of-view mode with shaped pupil coronagraph. More than 90 distinct error items were identified, including system aberrations, optical misalignment, component manufacturing error, telescope interface related errors, etc. The result forms the basis for raw contrast error budget flow down to a sub-system level, where detailed specifications needed to aid in component design and manufacturing, mechanical alignment and instrument integration, and verification and validation operations. Evaluations are mostly automated, making it relatively easy for repeat runs of revised design or at new desired error quantity. Top error sensitivities and contrast floor contributors are discussed and several observations are noted.

Poberezhskiy, Ilya↗

Precision orbit analyses in support of the Seasat altimeter experiment

It is noted that major improvements have been made in the Goddard Space Flight Center (GSFC) geodynamic models for Seasat. It is pointed out that the dominant error source in Seasat ephemeris computation is currently the uncertainty in modeling the earth's gravity field. Attention is also given to significant errors arising from atmospheric drag and solar radiation pressure modeling. It is noted that a comparison of GSFC and Naval Surface Weapons Center (NSWC) Seasat ephemerides indicate the presence of an unexplained difference of about 4 m in the location of the center of mass along the Z axis. This difference is consistent with that obtained with earlier geoid and station coordinated comparisons performed by other investigators. It is expected that future combinations of Seasat and GEOS-3 altimeter data, together with laser and Unified S-Band tracking data, will ultimately produce a gravity field which allows computations of a global Seasat ephemeris with an rms radial accuracy of about 50 cm.

Marsh, J. G.↗

AVHRR-Based Polar Pathfinder Products: Evaluation, Enhancement and Transition to MODIS

The Advanced Very High Resolution Radiometer (AVHRR)-Based Polar Pathfinder (APP) products include calibrated AVHRR channel data, surface temperatures, albedo, satellite scan and solar geometries, and cloud mask, all composited into twice-per-day images, and daily averaged fields of sea ice motion, for regions poleward of 50 latitude. Our general goals under this grant: (1) Quantify the APP accuracy and sources of error by comparing Pathfinder products with field measurements; (2) Determine the consistency of mean fields and trends in comparison with longer time series of available station data and forecast model output; (3) Investigate the consistency of the products between the different AVHRR instruments over the 1982-present period of the NOAA program; and (4) Compare and annual cycle of the APP products with MODIS to establish a baseline for extending Pathfinder-type products into the new ESE period.

Fowler, Charles↗

Reducing Ground-based Astrometric Errors with Gaia and Gaussian Processes

Stochastic field distortions caused by atmospheric turbulence are a fundamental limitation to the astrometric accuracy of ground-based imaging. This distortion field is measurable at the locations of stars with accurate positions provided by the Gaia DR2 catalog; we develop the use of Gaussian process regression (GPR) to interpolate the distortion field to arbitrary locations in each exposure. We introduce an extension to standard GPR techniques that exploits the knowledge that the 2D distortion field is curl-free. Applied to several hundred 90 s exposures from the Dark Energy Survey as a test bed, we find that the GPR correction reduces the variance of the turbulent astrometric distortions ≈12× , on average, with better performance in denser regions of the Gaia catalog. The rms per-coordinate distortion in the riz bands is typically ≈7 mas before any correction and ≈2 mas after application of the GPR model. The GPR astrometric corrections are validated by the observation that their use reduces, from 10 to 5 mas rms, the residuals to an orbit fit to riz-band observations over 5 yr of the r = 18.5 trans-Neptunian object Eris. We also propose a GPR method, not yet implemented, for simultaneously estimating the turbulence fields and the 5D stellar solutions in a stack of overlapping exposures, which should yield further turbulence reductions in future deep surveys.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automatic tuning of the Community Atmospheric Model (CAM5) by using short-term hindcasts with an improved downhill simplex optimization method

Traditional trial-and-error tuning of uncertain parameters in global atmospheric general circulation models (GCMs) is time consuming and subjective. This study explores the feasibility of automatic optimization of GCM parameters for fast physics by using short-term hindcasts. An automatic workflow is described and applied to the Community Atmospheric Model (CAM5) to optimize several parameters in its cloud and convective parameterizations. We show that the auto-optimization leads to 10 % reduction of the overall bias in CAM5, which is already a well-calibrated model, based on a predefined metric that includes precipitation, temperature, humidity, and longwave/shortwave cloud forcing. The computational cost of the entire optimization procedure is about equivalent to a single 12-year atmospheric model simulation. The tuning reduces the large underestimation in the CAM5 longwave cloud forcing by decreasing the threshold relative humidity and the sedimentation velocity of ice crystals in the cloud schemes; it reduces the overestimation of precipitation by increasing the adjustment time in the convection scheme. The physical processes behind the tuned model performance for each targeted field are discussed. Limitations of the automatic tuning are described, including the slight deterioration in some targeted fields that reflect the structural errors of the model. It is pointed out that automatic tuning can be a viable supplement to process-oriented model evaluations and improvement.

54 ENVIRONMENTAL SCIENCES↗

Automatic tuning of the Community Atmospheric Model CAM5.3 by using short-term hindcasts with an improved downhill simplex optimization method

Traditional trial-and-error tuning of uncertain parameters in global atmospheric General Circulation Models (GCM) is time consuming and subjective. This study explores the feasibility of automatic optimization of GCM parameters for fast physics by using short-term hindcasts. An automatic workflow is described and applied to the Community Atmospheric Model (CAM5) to optimize several parameters in its cloud and convective parameterizations. We show that the auto-optimization leads to 10 % reduction of the overall bias in CAM5, which is already a well calibrated model, based on a pre-defined metric that includes precipitation, temperature, humidity, and longwave/shortwave cloud forcing. The computational cost of the entire optimization procedure is about equivalent to about a single 12-year atmospheric model simulation. The tuning reduces the large underestimation in the CAM5 longwave cloud forcing by decreasing the threshold relative humidity and the sedimentation velocity of ice crystals in the cloud schemes; it reduces the overestimation of precipitation by increasing the adjustment time in the convection scheme. The physical processes behind the tuned model performance for each targeted field are discussed. Limitations of the automatic tuning are described, including the slight deterioration in some targeted fields that reflect the structural errors of the model. It is pointed out that automatic tuning can be a viable supplement to process-oriented model evaluations and improvement.

54 ENVIRONMENTAL SCIENCES↗