Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Decoherence and dephasing errors caused by the dc Stark effect in rapid ion transport

We investigate the error due to the dc Stark effect for quantum information processing for trapped ion quantum computers using the scalable architecture proposed in D. Wineland et al. [J. Res. Natl. Inst. Stand. Technol. 103, 259 (1998)] and D. Kielpinski et al. [Nature (London) 417, 709 (2002)]. As the operational speed increases, dephasing and decoherence due to the dc Stark effect become prominent as a large electric field is applied for rapidly transporting ions. We estimate the relative significance of the decoherence and dephasing effects and find that the latter is dominant. We find that the minimum possible dephasing is quadratic in the length of a trap and an inverse cubic in the operational time scale. From these relations, we obtain the operational speed range at which the shifts, caused by the dc Stark effect, are no longer negligible, no matter on which trajectory the ion is transported. Without phase correction, the shortest time a qubit can be transferred across a 100-micrometer-long trap, without excessive error, is about 10 ns for a {sup 40}Ca{sup +} ion and 50 ps for a {sup 9}Be{sup +} ion. In practice, the accumulated error is difficult to track and to calculate; thus, our paper gives an estimate for the range of the speed limit imposed by the dc Stark effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental quantum error correction with high fidelity

More than ten years ago a first step toward quantum error correction (QEC) was implemented [Phys. Rev. Lett. 81, 2152 (1998)]. The work showed there was sufficient control in nuclear magnetic resonance to implement QEC, and demonstrated that the error rate changed from {epsilon} to {approx}{epsilon}{sup 2}. In the current work we reproduce a similar experiment using control techniques that have been since developed, such as the pulses generated by gradient ascent pulse engineering algorithm. We show that the fidelity of the QEC gate sequence and the comparative advantage of QEC are appreciably improved. This advantage is maintained despite the errors introduced by the additional operations needed to protect the quantum states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reducing sequencing complexity in dynamical quantum error suppression by Walsh modulation

We study dynamical error suppression from the perspective of reducing sequencing complexity, with an eye toward facilitating the development of efficient semiautonomous quantum-coherent systems. To this end, we focus on digital sequences where all interpulse time periods are integer multiples of a minimum clock period and compatibility with digital classical control circuitry is intrinsic. We use so-called Walsh functions as a unifying mathematical framework; the Walsh functions are an orthonormal set of basis functions which may be associated directly with the control propagator for a digital modulation scheme. Using this insight, we characterize the suite of resulting Walsh dynamical decoupling sequences--including both familiar and novel control sequences--and identify the number of periodic square-wave (Rademacher) functions required to generate the associated Walsh function as the key determinant of the error-suppressing features. We also show how Walsh modulation may be employed for the protection of certain nontrivial logic gates. Based on these insights, we identify Walsh modulation as a digital-efficient approach for physical-layer error suppression.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Matching post-Newtonian and numerical relativity waveforms: Systematic errors and a new phenomenological model for nonprecessing black hole binaries

We present a new phenomenological gravitational waveform model for the inspiral and coalescence of nonprecessing spinning black hole binaries. Our approach is based on a frequency-domain matching of post-Newtonian inspiral waveforms with numerical relativity based binary black hole coalescence waveforms. We quantify the various possible sources of systematic errors that arise in matching post-Newtonian and numerical relativity waveforms, and we use a matching criteria based on minimizing these errors; we find that the dominant source of errors are those in the post-Newtonian waveforms near the merger. An analytical formula for the dominant mode of the gravitational radiation of nonprecessing black hole binaries is presented that captures the phenomenology of the hybrid waveforms. Its implementation in the current searches for gravitational waves should allow cross-checks of other inspiral-merger-ringdown waveform families and improve the reach of gravitational-wave searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Intermediate-mass-ratio inspirals in the Einstein Telescope. II. Parameter estimation errors

We explore the precision with which the Einstein Telescope will be able to measure the parameters of intermediate-mass-ratio inspirals, i.e., the inspirals of stellar mass compact objects into intermediate-mass black holes (IMBHs). We calculate the parameter estimation errors using the Fisher Matrix formalism and present results of Monte Carlo simulations of these errors over choices for the extrinsic parameters of the source. These results are obtained using two different models for the gravitational waveform which were introduced in paper I of this series. These two waveform models include the inspiral, merger, and ringdown phases in a consistent way. One of the models, based on the transition scheme of Ori and Thorne [A. Ori and K. S. Thorne, Phys. Rev. D 62, 124022 (2000)], is valid for IMBHs of arbitrary spin; whereas, the second model, based on the effective-one-body approach, has been developed to cross-check our results in the nonspinning limit. In paper I of this series, we demonstrated the excellent agreement in both phase and amplitude between these two models for nonspinning black holes, and that their predictions for signal-to-noise ratios are consistent to within 10%. We now use these waveform models to estimate parameter estimation errors for binary systems with masses 1.4M{sub {circle_dot}}+100M{sub {circle_dot}}, 10M{sub {circle_dot}}+100M{sub {circle_dot}}, 1.4M{sub {circle_dot}}+500M{sub {circle_dot}}, and 10M{sub {circle_dot}}+500M{sub {circle_dot}} and various choices for the spin of the central IMBH. Assuming a detector network of three Einstein Telescopes, the analysis shows that for a 10M{sub {circle_dot}} compact object inspiralling into a 100M{sub {circle_dot}} IMBH with spin q=0.3, detected with a signal-to-noise ratio of 30, we should be able to determine the compact object and IMBH masses, and the IMBH spin magnitude to fractional accuracies of {approx}10{sup -3}, {approx}10{sup -3.5}, and {approx}10{sup -3}, respectively. We also expect to determine the location of the source in the sky and the luminosity distance to within {approx}0.003 steradians and {approx}10%, respectively. We also compute results for several different possible configurations of the detector network to assess how the precision of parameter determination depends on the network configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

SZ3: A Modular Framework for Composing Prediction-Based Error-Bounded Lossy Compressors

Today's scientific simulations require a significant reduction of data volume because of extremely large amounts of data they produce and the limited I/O bandwidth and storage space. Here, error-bounded lossy compression has been considered one of the most effective solutions to the above problem. In practice, however, the best-fit compression method often needs to be customized or optimized in particular because of diverse characteristics in different datasets and various user requirements on the compression quality and performance. In this paper, we address this issue with a novel modular, composable compression framework named SZ3. Our contributions are four-folds. (1) We develop SZ3 which features an innovative modular abstraction for the prediction-based compression framework, such that compression modules can be plugged in easily to create new compressors based on characteristics of data and user requirements. (2) We create a new compression pipeline by SZ3 for GAMESS data, which significantly improves the compression ratios over state-of-the-art compressors. (3) We develop an adaptive compression pipeline by SZ3 for APS data with minimal efforts, which leads to the best rate-distortion among all existing error-bounded lossy compressors for any bit-rate. (4) We compare the sustainability of SZ3 with leading error-bounded prediction-based compressors, and then demonstrate the necessity of diverse pipelines by integrating and evaluating several compression pipelines on diverse scientific datasets from multiple disciplines. Experiments show that SZ3 incurs very limited overhead in compressor integration and our customized compression pipelines lead to up to 20% improvement in compression ratios under the same data distortion, when compared with the best existing approach.

97 MATHEMATICS AND COMPUTING↗

Layer-Dependent Bit Error Variation in 3-D NAND Flash Under Ionizing Radiation

In this paper, we studied the total ionization dose (TID) effects on the multilevel-cell (MLC) 3-D NAND flash memory using Co-60 gamma radiation. We found a significant page-to-page bit error variation within a physical memory block of the irradiated memory chip. Our analysis showed that the origin of the bit error variation is the unique vertical layer-dependent TID response of the 3-D NAND. We found that the memory pages located at the upper and lower layers of the 3-D stack show higher fails compared to the middle-layer pages of a given memory block. We confirmed our findings by comparing radiation response of four different chips of the same specification. In addition, we compared the TID response of the MLC 3-D NAND with that of the 2-D NAND chip, which showed less page-to-page variation in bit error within a given memory block. We discuss the possible application of our findings for the radiation-tolerant smart memory controller design.

3-D NAND flash↗

Optimization of Error-Bounded Lossy Compression for Hard-to-Compress HPC Data

Since today’s scientific applications are producing vast amounts of data, compressing them before storage/transmission is critical. Results of existing compressors show two types of HPC data sets: highly compressible and hard to compress. In this work, we carefully design and optimize the error-bounded lossy compression for hard-tocompress scientific data. We propose an optimized algorithm that can adaptively partition the HPC data into best-fit consecutive segments each having mutually close data values, such that the compression condition can be optimized. Another significant contribution is the optimization of shifting offset such that the XOR-leading-zero length between two consecutive unpredictable data points can be maximized. We finally devise an adaptive method to select the best-fit compressor at runtime for maximizing the compression factor. We evaluate our solution using 13 benchmarks based on real-world scientific problems, and we compare it with 9 other state-of-the-art compressors. Experiments show that our compressor can always guarantee the compression errors within the user-specified error bounds. Most importantly, our optimization can improve the compression factor effectively, by up to 49% for hard-tocompress data sets with similar compression/decompression time cost.

97 MATHEMATICS AND COMPUTING↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An approach for online evaluations of dose consequences caused by small rotational setup errors in intracranial stereotactic radiation therapy

Purpose: The purpose of this work is to investigate the impact of small rotational errors on the magnitudes and distributions of spatial dose variations for intracranial stereotactic radiotherapy (SRT) treatment setups, and to assess the feasibility of using the original dose map overlaid with rotated contours (ODMORC) method as a fast, online evaluation tool to estimate dose changes (using DVHs) to clinical target volumes (CTVs) and organs-at-risks (OARs) caused by small rotational setup errors. Methods: Fifteen intracranial SRT cases treated with either three-dimensional conformal radiation therapy (3DCRT) or intensity-modulated radiation therapy (IMRT) techniques were chosen for the study. Selected cases have a variety of anatomical dimensions and pathologies. Angles of {+-}3 deg. and {+-}5 deg. in all directions were selected to simulate the rotational errors. Dose variations in different regions of the brain, CTVs, and OARs were evaluated to illustrate the various spatial effects of dose differences before and after rotations. DVHs accounting for rotations that were recomputed by the treatment planning system (TPS) and those generated by the ODMORC method were compared. A framework of a fast algorithm for multicontour rotation implemented by ODMORC is introduced as well. Results: The average values of relative dose variations between original dose and recomputed dose accounting for rotations were greater than 4.0% and 10.0% in absolute mean and in standard deviation, respectively, at the skull and adjacent regions for all cases. They were less than 1.0% and 2.5% in absolute mean and in standard deviation, respectively, for dose points 3 mm away from the skull. The results indicated that spatial dose to any part of the brain organs or tumors separated from the skull or head surface would be relatively stable before and after rotations. Statistical data of CTVs and OARs indicate the lens and cochleas have the large dose variations before and after rotations, whereas the remaining ROIs have insignificant dose differences. DVH comparisons suggest that the ODMORC method is able to estimate the DVH of CTVs fairly accurately (within 1.5% of relative dose differences for evaluation volumes). The results also show that most of the OARs including the brain stem, spinal cord, chiasm, hippocampuses, optic nerves, and retinas, which were relatively distal from the skull and surface, had good agreement (within 2.0% of relative dose differences for 0.1 cc of the volumes ) between the ODMORC method and the recomputation, whereas OARs more proximate to the bone-tissue interface or surface, such as the lenses and cochlea, had larger dose variations (greater than 5.0%) for some cases due to the incapability of the ODMORC to account for scatter contribution variations proximate to interfaces and intrinsic dose calculation uncertainties for ROIs with small volumes. Conclusions: The ODMORC method can be implemented as an online evaluation system for rotation-induced dose changes of CTVs and most OARs and for other related dose consequence analyses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Contrast solution density and cross section errors in inhomogeneity-corrected dose calculation for breast balloon brachytherapy

Purpose: Recent recommendations by the American Association of Physicists in Medicine Task Group 186 emphasize the importance of understanding material properties and their effect on inhomogeneity-corrected dose calculation for brachytherapy. Radiographic contrast is normally injected into breast brachytherapy balloons. In this study, the authors independently estimate properties of contrast solution that were expected to be incorrectly specified in a commercial brachytherapy dose calculation algorithm. Methods: The mass density and atomic weight fractions of a clinical formulation of radiographic contrast solution were determined using manufacturers' data. The mass density was verified through measurement and compared with the density obtained by the treatment planning system's CT calibration. The atomic weight fractions were used to determine the photon interaction cross section of the contrast solution for a commercial high-dose-rate (HDR) brachytherapy source and compared with that of muscle. Results: The density of contrast solution was 10% less than that obtained from the CT calibration. The cross section of the contrast solution for the HDR source was 1.2% greater than that of muscle. Both errors could be addressed by overriding the density of the contrast solution in the treatment planning system. Conclusions: The authors estimate the error in mass density and cross section parameters used by a commercial brachytherapy dose calculation algorithm for radiographic contrast used in a clinical breast brachytherapy practice. This approach is adaptable to other clinics seeking to evaluate dose calculation errors and determine appropriate density override values if desired.

60 APPLIED LIFE SCIENCES↗

SU-E-T-51: Bayesian Network Models for Radiotherapy Error Detection

Purpose: To develop a probabilistic model of radiotherapy plans using Bayesian networks that will detect potential errors in radiation delivery. Methods: Semi-structured interviews with medical physicists and other domain experts were employed to generate a set of layered nodes and arcs forming a Bayesian Network (BN) which encapsulates relevant radiotherapy concepts and their associated interdependencies. Concepts in the final network were limited to those whose parameters are represented in the institutional database at a level significant enough to develop mathematical distributions. The concept-relation knowledge base was constructed using the Web Ontology Language (OWL) and translated into Hugin Expert Bayes Network files via the the RHugin package in the R statistical programming language. A subset of de-identified data derived from a Mosaiq relational database representing 1937 unique prescription cases was processed and pre-screened for errors and then used by the Hugin implementation of the Estimation-Maximization (EM) algorithm for machine learning all parameter distributions. Individual networks were generated for each of several commonly treated anatomic regions identified by ICD-9 neoplasm categories including lung, brain, lymphoma, and female breast. Results: The resulting Bayesian networks represent a large part of the probabilistic knowledge inherent in treatment planning. By populating the networks entirely with data captured from a clinical oncology information management system over the course of several years of normal practice, we were able to create accurate probability tables with no additional time spent by experts or clinicians. These probabilistic descriptions of the treatment planning allow one to check if a treatment plan is within the normal scope of practice, given some initial set of clinical evidence and thereby detect for potential outliers to be flagged for further investigation. Conclusion: The networks developed here support the use of probabilistic models into clinical chart checking for improved detection of potential errors in RT plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-318: The Effect of Patient Positioning Errors On Target Coverage and Cochlear Dose in Stereotactic Radiosurgery Treatment of Acoustic Neuromas

Purpose: Setup errors on the order of millimeters may cause under-dosing of targets and significant changes in dose to critical structures especially when planning with tight margins in stereotactic radiosurgery. This study evaluates the effects of these types of patient positioning uncertainties on planning target volume (PTV) coverage and cochlear dose for stereotactic treatments of acoustic neuromas. Methods: Twelve acoustic neuroma patient treatment plans were retrospectively evaluated in Brainlab iPlan RT Dose 4.1.3. All treatment beams were shaped by HDMLC from a Varian TX machine. Seven patients had planning margins of 2mm, five had 1–1.5mm. Six treatment plans were created for each patient simulating a 1mm setup error in six possible directions: anterior-posterior, lateral, and superiorinferior. The arcs and HDMLC shapes were kept the same for each plan. Change in PTV coverage and mean dose to the cochlea was evaluated for each plan. Results: The average change in PTV coverage for the 72 simulated plans was −1.7% (range: −5 to +1.1%). The largest average change in coverage was observed for shifts in the patient's superior direction (−2.9%). The change in mean cochlear dose was highly dependent upon the direction of the shift. Shifts in the anterior and superior direction resulted in an average increase in dose of 13.5 and 3.8%, respectively, while shifts in the posterior and inferior direction resulted in an average decrease in dose of 17.9 and 10.2%. The average change in dose to the cochlea was 13.9% (range: 1.4 to 48.6%). No difference was observed based on the size of the planning margin. Conclusion: This study indicates that if the positioning uncertainty is kept within 1mm the setup errors may not result in significant under-dosing of the acoustic neuroma target volumes. However, the change in mean cochlear dose is highly dependent upon the direction of the shift.

60 APPLIED LIFE SCIENCES↗

SU-E-T-405: Robustness of Volumetric-Modulated Arc Therapy (VMAT) Plans to Systematic MLC Positional Errors

Purpose: To evaluate the dosimetric impact of systematic MLC positional errors (PEs) on the quality of volumetric-modulated arc therapy (VMAT) plans. Methods: Five patients with head-and-neck cancer (HN) and five patients with prostate cancer were randomly chosen for this study. The clinically approved VMAT plans were designed with 2–4 coplanar arc beams with none-zero collimator angles in the Pinnacle planning system. The systematic MLC PEs of 0.5, 1.0, and 2.0 mm on both MLC banks were introduced into the original VMAT plans using an in-house program, and recalculated with the same planned Monitor Units in the Pinnacle system. For each patient, the original VMAT plans and plans with MLC PEs were evaluated according to the dose-volume histogram information and Gamma index analysis. Results: For one primary target, the ratio of V100 in the plans with 0.5, 1.0, and 2.0 mm MLC PEs to those in the clinical plans was 98.8 ± 2.2%, 97.9 ± 2.1%, 90.1 ± 9.0% for HN cases and 99.5 ± 3.2%, 98.9 ± 1.0%, 97.0 ± 2.5% for prostate cases. For all OARs, the relative difference of Dmean in all plans was less than 1.5%. With 2mm/2% criteria for Gamma analysis, the passing rates were 99.0 ± 1.5% for HN cases and 99.7 ± 0.3% for prostate cases between the planar doses from the original plans and the plans with 1.0 mm MLC errors. The corresponding Gamma passing rates dropped to 88.9 ± 5.3% for HN cases and 83.4 ± 3.2% for prostate cases when comparing planar doses from the original plans and the plans with 2.0 mm MLC errors. Conclusion: For VMAT plans, systematic MLC PEs up to 1.0 mm did not affect the plan quality in term of target coverage, OAR sparing, and Gamma analysis with 2mm/2% criteria.

60 APPLIED LIFE SCIENCES↗

Benchmarking of a treatment planning system for spot scanning proton therapy: Comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma

Purpose: Base of skull meningioma can be treated with both intensity modulated radiation therapy (IMRT) and spot scanned proton therapy (PT). One of the main benefits of PT is better sparing of organs at risk, but due to the physical and dosimetric characteristics of protons, spot scanned PT can be more sensitive to the uncertainties encountered in the treatment process compared with photon treatment. Therefore, robustness analysis should be part of a comprehensive comparison between these two treatment methods in order to quantify and understand the sensitivity of the treatment techniques to uncertainties. The aim of this work was to benchmark a spot scanning treatment planning system for planning of base of skull meningioma and to compare the created plans and analyze their robustness to setup errors against the IMRT technique. Methods: Plans were produced for three base of skull meningioma cases: IMRT planned with a commercial TPS [Monaco (Elekta AB, Sweden)]; single field uniform dose (SFUD) spot scanning PT produced with an in-house TPS (PSI-plan); and SFUD spot scanning PT plan created with a commercial TPS [XiO (Elekta AB, Sweden)]. A tool for evaluating robustness to random setup errors was created and, for each plan, both a dosimetric evaluation and a robustness analysis to setup errors were performed. Results: It was possible to create clinically acceptable treatment plans for spot scanning proton therapy of meningioma with a commercially available TPS. However, since each treatment planning system uses different methods, this comparison showed different dosimetric results as well as different sensitivities to setup uncertainties. The results confirmed the necessity of an analysis tool for assessing plan robustness to provide a fair comparison of photon and proton plans. Conclusions: Robustness analysis is a critical part of plan evaluation when comparing IMRT plans with spot scanned proton therapy plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-170: Dosimetric Consequences of Uncorrected Rotational Setup Errors During Stereotactic Body Radiation Therapy (SBRT) Treatment of Pancreatic Cancers

Purpose: To explore the dosimetric consequences of uncorrected rotational setup errors during SBRT for pancreatic cancer patients. Methods: This was a retrospective study utilizing data from ten (n=10) previously treated SBRT pancreas patients. For each original planning CT, we applied rotational transformations to derive additional CT images representative of possible rotational setup errors. This resulted in 6 different sets of rotational combinations, creating a total of 60 CT planning images. The patients’ clinical dosimetric plans were then applied to their corresponding rotated CT images. The 6 rotation sets encompassed a 3, 2 and 1-degree rotation in each rotational direction and a 3-degree in just the pitch, a 3-degree in just the yaw and a 3-degree in just the roll. After the dosimetric plan was applied to the rotated CT images, the resulting plan was then evaluated and compared with the clinical plan for tumor coverage and normal tissue sparing. Results: PTV coverage, defined here by V33 throughout all of the patients’ clinical plans, ranged from 92–98%. After an n degree rotation in each rotational direction that range decreased to 68–87%, 85–92%, and 88– 94% for n=3, 2 and 1 respectively. Normal tissue sparing defined here by the proximal stomach V15 throughout all of the patients’ clinical plans ranged from 0–8.9 cc. After an n degree rotation in each rotational direction that range increased to 0–17 cc, 0–12 cc, and 0–10 cc for n=3, 2, and 1 respectively. Conclusion: For pancreatic SBRT, small rotational setup errors in the pitch, yaw and roll direction on average caused under dosage to PTV and over dosage to proximal normal tissue. The 1-degree rotation was on average the least detrimental to the normal tissue and the coverage of the PTV. The 3-degree yaw created on average the lowest increase in volume coverage to normal tissue. This research was sponsored by the AAPM Education Council through the AAPM Education and Research Fund for the AAPM Summer Undergraduate Fellowship Program.

60 APPLIED LIFE SCIENCES↗

SU-E-J-172: Bio-Physical Effects of Patients Set-Up Errors According to Whole Breast Irradiation Techniques

Purpose: The dose-related effects of patient setup errors on biophysical indices were evaluated for conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques. Methods: The treatment plans for 10 patients receiving whole left breast irradiation were retrospectively selected. Radiobiological and physical effects caused by dose variations were evaluated by shifting the isocenters and gantry angles of the treatment plans. Dose-volume histograms of the planning target volume (PTV), heart, and lungs were generated, and conformity index (CI), homogeneity index (HI), tumor control probability (TCP), and normal tissue complication probability (NTCP) were determined. Results: For “isocenter shift plan” with posterior direction, the D95 of the PTV decreased by approximately 15% and the TCP of the PTV decreased by approximately 50% for the FIF technique and by 40% for the CW; however, the NTCPs of the lungs and heart increased by about 13% and 1%, respectively, for both techniques. Increasing the gantry angle decreased the TCPs of the PTV by 24.4% (CW) and by 34% (FIF). The NTCPs for the two techniques differed by only 3%. In case of CW, the CIs and HIs were much higher than that of the FIF in all cases. It had a significant difference between two techniques (p<0.01). According to our results, however, the FIF had more sensitive response by set up errors rather than CW in bio-physical aspects. Conclusions: The radiobiological-based analysis can detect significant dosimetric errors then, can provide a practical patient quality assurance method to guide the radiobiological and physical effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗