Search NASA⌕ Search

SEARCH · Search NASA

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Impact of energy filtering and carrier localization on the thermoelectric properties of granular semiconductors

Energy filtering has been widely considered as a suitable tool to increase the thermoelectric performances of several classes of materials. In its essence, energy filtering provides a way to increase the Seebeck coefficient by introducing a strongly energy-dependent scattering mechanism. Under certain conditions, however, potential barriers may lead to carrier localization, that may also affect the thermoelectric properties of a material. A model is proposed, actually showing that randomly distributed potential barriers (as those found, e.g., in polycrystalline films) may lead to the simultaneous occurrence of energy filtering and carrier localization. Localization is shown to cause a decrease of the actual carrier density that, along with the quantum tunneling of carriers, may result in an unexpected increase of the power factor with the doping level. The model is corroborated toward experimental data gathered by several authors on degenerate polycrystalline silicon and lead telluride. - Graphical abstract: In heavily doped semiconductors potential barriers may lead to both carrier energy filtering and localization. This may lead to an enhancement of the thermoelectric properties of the material, resulting in an unexpected increase of the power factor with the doping level. Highlights: Black-Right-Pointing-Pointer Potential barriers are shown to lead to carrier localization in thermoelectric materials. Black-Right-Pointing-Pointer Evidence is put forward of the formation of a mobility edge. Black-Right-Pointing-Pointer Energy filtering and localization may explain the enhancement of power factor in degenerate semiconductors.

36 MATERIALS SCIENCE↗

Quantum filter of spin polarized states: Metal–dielectric–ferromagnetic/semiconductor device

Highlights: • Development of a new spintronics device. • Development of quantum spin polarized filters. • Development of theory of quantum spin polarized filter. - Abstract: Recently we proposed a model for the Quantum Spin-Polarized State Filter (QSPSF). The magnetic moments are transported selectively in this model, detached from the electric charge carriers. Thus, transfer of a spin-polarized state between two conductors was predicted in a system of two levels coupled by exchange interaction. The strength of the exchange interaction between the two conductive layers depends on the thickness of the dielectric layer separating them. External magnetic fields modulate spin-polarized state transfer, due to Zeeman level shift. Therefore, a linearly growing magnetic field generates a series of current peaks in a nearby coil. Thus, our spin-state filter should contain as least three nanolayers: (1) conductive or ferromagnetic; (2) dielectric; and (3) conductive or semiconductive. The spectrum of spin-polarized states generated by the filter device consists of a series of resonance peaks. In a simple case the number of lines equals S, the total spin angular momentum of discrete states in one of the coupled nanolayers. Presently we report spin-polarized state transport in metal–dielectric–ferromagnetic (MDF) and metal–dielectric–semiconductor (MDS) three-layer sandwich devices. The exchange-resonance spectra in such devices are quite specific, differing also from spectra observed earlier in other three-layer devices. The theoretical model is used to interpret the available experimental results. A detailed ab initio analysis of the magnetic-field dependence of the output magnetic moment averaged over the surface of the device was carried out. The model predicts the resonance structure of the signal, although at its present accuracy it cannot predict the positions of the spectral peaks.

36 MATERIALS SCIENCE↗

Localness of energy cascade in hydrodynamic turbulence, II. Sharp spectral filter

We investigate the scale-locality of subgrid-scale (SGS) energy flux and interband energy transfers defined by the sharp spectral filter. We show by rigorous bounds, physical arguments, and numerical simulations that the spectral SGS flux is dominated by local triadic interactions in an extended turbulent inertial range. Interband energy transfers are also shown to be dominated by local triads if the spectral bands have constant width on a logarithmic scale. We disprove in particular an alternative picture of 'local transfer by nonlocal triads,' with the advecting wavenumber mode at the energy peak. Although such triads have the largest transfer rates of all individual wavenumber triads, we show rigorously that, due to their restricted number, they make an asymptotically negligible contribution to energy flux and log-banded energy transfers at high wavenumbers in the inertial range. We show that it is only the aggregate effect of a geometrically increasing number of local wavenumber triads which can sustain an energy cascade to small scales. Furthermore, nonlocal triads are argued to contribute even less to the space-average energy flux than is implied by our rigorous bounds, because of additional cancellations from scale-decorrelation effects. We can thus recover the -4/3 scaling of nonlocal contributions to spectral energy flux predicted by Kraichnan's abridged Lagrangian-history direct-interaction approximation and test-field model closures. We support our results with numerical data from a 512{sup 3} pseudospectral simulation of isotropic turbulence with phase-shift dealiasing. We also discuss a rigorous counterexample of Eyink [Physica D 78, 222 (1994)], which showed that nonlocal wavenumber triads may dominate in the sharp spectral flux (but not in the SGS energy flux for graded filters). We show that this mathematical counter example fails to satisfy reasonable physical requirements for a turbulent velocity field, which are employed in our proof of scale locality. We conclude that the sharp spectral filter has a firm theoretical basis for use in large-eddy simulation modeling of turbulent flows.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high-power spatial filter for Thomson scattering stray light reduction

The Thomson scattering diagnostic on the High Beta Tokamak-Extended Pulse (HBT-EP) is routinely used to measure electron temperature and density during plasma discharges. Avalanche photodiodes in a five-channel interference filter polychromator measure scattered light from a 6 ns, 800 mJ, 1064 nm Nd:YAG laser pulse. A low cost, high-power spatial filter was designed, tested, and added to the laser beamline in order to reduce stray laser light to levels which are acceptable for accurate Rayleigh calibration. A detailed analysis of the spatial filter design and performance is given. The spatial filter can be easily implemented in an existing Thomson scattering system without the need to disturb the vacuum chamber or significantly change the beamline. Although apertures in the spatial filter suffer substantial damage from the focused beam, with proper design they can last long enough to permit absolute calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The simulation and improved design of tunable channel drop filter using hexagonal photonic crystal ring resonator

In this paper, we have proposed a new design of tunable two dimensional (2D) photonic crystal (PhC) channel drop filter (CDF) using ring resonators. The increasing interest in photonic integrated circuits (PIC's) and the increasing use of all-optical fiber networks as backbones for global communication systems have been based in large part on the extremely wide optical transmission bandwidth provided by dielectric materials. Based on the analysis we present novel photonic crystal channel drop filters. Simulations demonstrate that these filters exhibit ideal transfer characteristics. Channel dropping filters (CDF's) that access one channel of a wavelength division multiplexed (WDM) signal while leaving other channels undisturbed are essential components of PIC's and optical communication systems. In this paper we have investigated such parameters which have an effect on resonant wavelength in this Channel Drop Filter, such as dielectric constant of inner, coupling, adjacent and whole rods of the structure. The dimensions of these structures are taken as 20a×19a and the area of the proposed structure is about 125.6μm{sup 2}; therefore this structure can be used in the future photonic integrated circuits. While using this design the dropping efficiency at the resonance of single ring are 100%. The spectrum of the power transmission is obtained with finite difference time domain (FDTD) method. FDTD method is the most famous method for PhC analysis. In this paper the dielectric rods have a dielectric constant of 10.65, so the refractive index is 3.26 and radius r=0.213a is located in air, where a is a lattice constant. In this we have used five scatter rods for obtaining more coupling efficiency; radius of scatter rods is set to 0.215a. The proposed structure is simulated with OptiFDTD.v.8.0 software, the different dielectric constant of rods equal to ε{sub r}−0.4, ε{sub r} and ε{sub r}+0.4 at wavelength of 1570 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical Purcell filters for microwave quantum machines

In circuit quantum electrodynamics, measuring the state of a superconducting qubit introduces a loss channel, which can enhance spontaneous emission through the Purcell effect, thus decreasing the qubit lifetime. This decay can be mitigated by performing the measurement through a Purcell filter, which strongly suppresses signal propagation at the qubit transition frequency. If the filter is also well-matched at the readout cavity frequency, it will protect the qubit from decoherence channels without sacrificing measurement bandwidth. In this work, we propose and analyze design for a mechanical Purcell filter, which we also fabricate and characterize at room temperature. The filter is composed of an array of nanomechanical resonators in thin-film lithium niobate, connected in a ladder topology, with series and parallel resonances arranged to produce a bandpass response. Their modest footprint, steep band edges, and lack of cross talk make these filters an appealing alternative to analogous electromagnetic versions currently used in microwave quantum machines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning based unfolding of x-ray spectra from filter stack spectrometer data

We demonstrate the application of neural networks to perform x-ray spectra unfolding from data collected by filter stack spectrometers. A filter stack spectrometer consists of a series of filter-detector pairs, where the detectors behind each filter measure the energy deposition through each layer as photo-stimulated luminescence (PSL). The network is trained on synthetic data, assuming x-rays of energies < 1 MeV and of two different distribution functions (Maxwellian and Gaussian) and the corresponding measured PSL values obtained from five different filter stack spectrometer designs. Predicted unfolds of single distributions are near identical reproductions of the ground truth spectra, with differences in the values lower than 20% at the higher energy end in some cases. The neural network has also demonstrated robustness to experimental measurement errors of < 5% and some capability of performing unfolds for linear combinations of the two distributions without previous training. The network can perform unfolds at rates > 1 Hz, ideal for application to some high-repetition-rate systems.

47 OTHER INSTRUMENTATION↗

STEPWISE FILTER CORRELATION METHOD AND EVIDENCE OF SUPERPOSED VARIABILITY COMPONENTS IN GAMMA-RAY BURST PROMPT EMISSION LIGHT CURVES

Gamma-ray bursts (GRBs) have variable light curves. Although most models attribute the observed variability to one physical origin (e.g., central engine activity, clumpy circumburst medium, or relativistic turbulence), some models invoke two physically distinct variability components. We develop a method, namely, the stepwise filter correlation method, to decompose the variability components in a GRB light curve. Based on a low-pass filter technique, we progressively filter the high-frequency signals from the light curve, and then perform a correlation analysis between each adjunct pair of filtered light curves. Our simulations suggest that if a mock light curve contains a 'slow' variability component superposed on a rapidly varying time sequence, the correlation coefficient as a function of the filter frequency would display a prominent 'dip' feature around the frequency of the slow component. Through simulations, we demonstrate that this method can identify significant clustering structures of a light curve in the frequency domain, and we prove that it can catch superposed signals that are otherwise not easy to retrieve based on other methods (e.g., the power density spectrum analysis method). We apply this method to 266 Burst and Transient Source Experiment bright GRBs. We find that the majority of the bursts have clear evidence of such a superposition effect. We perform a statistical analysis of the identified variability components and discuss the implications for GRB physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Design for the First Narrowband Filter for the Dark Energy Camera: Optimizing the LAGER Survey for z ∼ 7 Galaxies

We present the design for the first narrowband filter, NB964, for the Dark Energy Camera (DECam), which is operated on the 4-m Blanco Telescope at the Cerro Tololo Inter-American Observatory. The NB964 filter profile is essentially defined by maximizing the power of searching for Lyman-alpha emitting galaxies (LAEs) in the epoch of reionization, with the consideration of the night sky background in the near-infrared and the DECam quantum efficiency. The NB964 filter was manufactured by Materion in 2015. It has a central wavelength of 964.2 nm and a full width at half maximum (FWHM) of 9.2 nm. An NB964 survey named Lyman Alpha Galaxies in the Epoch of Reionization (LAGER) has been ongoing since December 2015. Here, we report results of lab tests, on-site tests, and observations with the NB964 filter. The excellent performances of this filter ensure that the LAGER project is able to detect LAEs at z ~ 7 with a high efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast response, optical radiance measurements of low intensity impurity emission in WEST plasmas with staggered wavelength filters

Fast response acquisition of atomic line emission through the use of a filterscope has been implemented on the WEST tokamak at multiple poloidal locations. Filterscopes consist of a fiber-optic-based transmission from the tokamak to specifically engineered optical bandpasses and photomultiplier tubes (PMT) that collect the emission intensity to measure a radiance, L [W/cm2/str], over the specified bandpass. This diagnostic records plasma-wall interaction (PWI) properties (e.g. impurity emission and recycling of main fuel ions) up to a max acquisition rate of 100 kHz. These PMT radiometric measurements are calibrated into a line-normalized radiance, LN [photons/sec/cm2/str], similar to traditional spectrometers, which can later be converted to a particle flux. Low intensity emission peaks are difficult to quantify due to often comparable continuum levels, thus a secondary filter shifted to a judiciously-selected, line-free region (~1 nm away) allows for background subtraction. The system currently installed on WEST targets tungsten (W) gross sputtering specifically by monitoring, with a filter pair, the spectral region near the neutral W line emission (W I 400.9 nm). The line and background filters of the pair are centered at 400.6 nm and 403.1 nm, respectively. Through a set beam splitters on each sight line, the filter pair are measuring from the same location. The two L signals near W I are then subtracted from each other yielding only the W I LN. W I LN data from a recent WEST experimental campaign is presented and compared with plasma parameters and traditional spectrometer measurements of W I line emission to demonstrate the capabilities of this staggered-filter filterscope method. Specifically, the choice of WEST-specific bandpass curves for the W I LN will be illustrated based on this latter comparison.

Neff, Anton↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the noise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

Johnson, Hans↗

Helium Degassing Filter for Mercury Process Gas Liquid Separator

Testing was conducted to find a suitable filter to help separate helium gas from the Spallation Neutron Source’s mercury process loop. This filter is proposed for installation on the gas-liquid separator (GLS) vent line to prevent a column of liquid mercury from flowing outside of the process loop shielding in the service bay. The filter’s desired properties are to prevent the passage of liquid mercury, provide minimal resistance to helium flow, resist radiation, operate for the lifetime of the target, be replaceable, and have a reliable construction. Testing concluded that the Mott Corporation POU-10-S series of filters provided the best performance available. The filters could stop most liquid mercury passage while allowing helium passage at nominal pressures above the GLS in standard conditions. This result has several implications for the design of the GLS vent system.

Weinmeister, Justin↗

Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT

Purpose: To investigate a novel locally adaptive projection space denoising algorithm for low-dose CT data. Methods: The denoising algorithm is based on bilateral filtering, which smooths values using a weighted average in a local neighborhood, with weights determined according to both spatial proximity and intensity similarity between the center pixel and the neighboring pixels. This filtering is locally adaptive and can preserve important edge information in the sinogram, thus maintaining high spatial resolution. A CT noise model that takes into account the bowtie filter and patient-specific automatic exposure control effects is also incorporated into the denoising process. The authors evaluated the noise-resolution properties of bilateral filtering incorporating such a CT noise model in phantom studies and preliminary patient studies with contrast-enhanced abdominal CT exams. Results: On a thin wire phantom, the noise-resolution properties were significantly improved with the denoising algorithm compared to commercial reconstruction kernels. The noise-resolution properties on low-dose (40 mA s) data after denoising approximated those of conventional reconstructions at twice the dose level. A separate contrast plate phantom showed improved depiction of low-contrast plates with the denoising algorithm over conventional reconstructions when noise levels were matched. Similar improvement in noise-resolution properties was found on CT colonography data and on five abdominal low-energy (80 kV) CT exams. In each abdominal case, a board-certified subspecialized radiologist rated the denoised 80 kV images markedly superior in image quality compared to the commercially available reconstructions, and denoising improved the image quality to the point where the 80 kV images alone were considered to be of diagnostic quality. Conclusions: The results demonstrate that bilateral filtering incorporating a CT noise model can achieve a significantly better noise-resolution trade-off than a series of commercial reconstruction kernels. This improvement in noise-resolution properties can be used for improving image quality in CT and can be translated into substantial dose reduction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method

Purpose: This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. Methods: For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. Results: The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, ''Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method,'' Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. Conclusions: The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

60 APPLIED LIFE SCIENCES↗

CT image artifacts from brachytherapy seed implants: A postprocessing 3D adaptive median filter

Purpose: To design a postprocessing 3D adaptive median filter that minimizes streak artifacts and improves soft-tissue contrast in postoperative CT images of brachytherapy seed implantations. Methods: The filter works by identifying voxels that are likely streaks and estimating more reflective voxel intensity by using voxel intensities in adjacent CT slices and applying a median filter over voxels not identified as seeds. Median values are computed over a 5x5x5 mm region of interest (ROI) within the CT volume. An acrylic phantom simulating a clinical seed implant arrangement and containing nonradioactive seeds was created. Low contrast subvolumes of tissuelike material were also embedded in the phantom. Pre- and postprocessed image quality metrics were compared using the standard deviation of ROIs between the seeds, the CT numbers of low contrast ROIs embedded within the phantom, the signal to noise ratio (SNR), and the contrast to noise ratio (CNR) of the low contrast ROIs. The method was demonstrated with a clinical postimplant CT dataset. Results: After the filter was applied, the standard deviation of CT values in streak artifact regions was significantly reduced from 76.5 to 7.2 HU. Within the observable low contrast plugs, the mean of all ROI standard deviations was significantly reduced from 60.5 to 3.9 HU, SNR significantly increased from 2.3 to 22.4, and CNR significantly increased from 0.2 to 4.1 (all P<0.01). The mean CT in the low contrast plugs remained within 5 HU of the original values. Conclusion: An efficient postprocessing filter that does not require access to projection data, which can be applied irrespective of CT scan parameters has been developed, provided the slice thickness and spacing is 3 mm or less.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter

Purpose: To compare dosimetric characteristics of 6 MV photon fields originating from a linear accelerator operating with (FF) and without (FFF) a flattening-filter. The main objective is to establish a FFF model that results in similar depth-dose and build-up profiles as the original FF model, and subsequently estimate and compare out-of-field dose distributions. Methods: The EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc are used for photon beam simulations of an Elekta linear accelerator and dose calculations in a water phantom, respectively. Three beam models were analyzed: (1) the conventional linear accelerator with the flattening-filter in place and incident electron energy 6.45 MeV (FF 6.45 MeV), (2) similar flattening-filter-free model (FFF 6.45 MeV), and (3) as (2) but with increased electron energy (FFF 8.0 MeV). The field size 5 Multiplication-Sign 5 cm{sup 2} was used for characterization of dose output, depth dose profiles, and photon spectrum. The field size 40 Multiplication-Sign 40 cm{sup 2} was used for characterization of cross-field photon energy, photon fluence, and dose distributions. Out-of-field dose distributions were analyzed in both in-plane and cross-plane directions for 5 Multiplication-Sign 5 cm{sup 2} and 10 Multiplication-Sign 10 cm{sup 2} fields. Results: Comparable depth dose distributions, including the build-up region, for FF and FFF fields were achieved by increasing the electron energy from 6.45 MeV to 8.0 MeV for the FFF beam. The FFF beams result in reduced out-of-field dose compared to the FF beam: the reduction was most apparent in the cross-plane direction and more pronounced by the FFF 8.0 MeV beam compared to the FFF 6.45 MeV beam. Differences in out-of-field dose due to direction (in-plane vs cross-plane) were up to 40% for the FF beam; this effect was significantly reduced for the FFF beams. As the flattening-filter is a major source of contaminating electrons, superficial out-of-field dose was expected, and was found to be, reduced for FFF beams. Conclusions: The build-up and depth-dose characteristics of a conventional '6 MV' beam can be maintained when changing to a flattening-filter-free modality by increasing the incident electron energy from 6.45 MeV to 8.0 MeV. This will at the same time reduce the out-of-field dose for regions up to 20 cm from the central axis by 10%-30% compared to the original FF situation.

07 ISOTOPE AND RADIATION SOURCES↗

An adaptive filtered back-projection for photoacoustic image reconstruction

Purpose: The purpose of this study is to develop an improved filtered-back-projection (FBP) algorithm for photoacoustic tomography (PAT), which allows image reconstruction with higher quality compared to images reconstructed through traditional algorithms. Methods: A rigorous expression of a weighting function has been derived directly from a photoacoustic wave equation and used as a ramp filter in Fourier domain. The authors’ new algorithm utilizes this weighting function to precisely calculate each photoacoustic signal’s contribution and then reconstructs the image based on the retarded potential generated from the photoacoustic sources. In addition, an adaptive criterion has been derived for selecting the cutoff frequency of a low pass filter. Two computational phantoms were created to test the algorithm. The first phantom contained five spheres with each sphere having different absorbances. The phantom was used to test the capability for correctly representing both the geometry and the relative absorbed energy in a planar measurement system. The authors also used another phantom containing absorbers of different sizes with overlapping geometry to evaluate the performance of the new method for complicated geometry. In addition, random noise background was added to the simulated data, which were obtained by using an arc-shaped array of 50 evenly distributed transducers that spanned 160° over a circle with a radius of 65 mm. A normalized factor between the neighbored transducers was applied for correcting measurement signals in PAT simulations. The authors assumed that the scanned object was mounted on a holder that rotated over the full 360° and the scans were set to a sampling rate of 20.48 MHz. Results: The authors have obtained reconstructed images of the computerized phantoms by utilizing the new FBP algorithm. From the reconstructed image of the first phantom, one can see that this new approach allows not only obtaining a sharp image but also showing the correct signal strength of the absorbers. The reconstructed image of the second phantom further demonstrates the capability to form clear images of the spheres with sharp borders in the overlapping geometry. The smallest sphere is clearly visible and distinguishable, even though it is surrounded by two big spheres. In addition, image reconstructions were conducted with randomized noise added to the observed signals to mimic realistic experimental conditions. Conclusions: The authors have developed a new FBP algorithm that is capable for reconstructing high quality images with correct relative intensities and sharp borders for PAT. The results demonstrate that the weighting function serves as a precise ramp filter for processing the observed signals in the Fourier domain. In addition, this algorithm allows an adaptive determination of the cutoff frequency for the applied low pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗