Search NASA⌕ Search

SEARCH · Search NASA

Results for “high angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Theoretical aspects of photoclinometric terrain profiling on the Galilean satellites

For large parts of the surfaces of the Galilean satellites there is no stereoscopic high resolution imagery, and so for shadow-free regions far from the terminator, the only method of obtaining topograpic information is photoclinometry, the technique of converting brightness variations into local surface tilts and hence into topographic profiles and contour maps. The conversion from brightness changes to slopes require knowledge of the angular photometric function for the type of planetary surface terrain being analyzed, i.e., the relationship describing the brightness of the surface as a function of the angles of incidence (I) and emergence (E) of light at a surface element. In order to investigate the effects of these changes on the shapes of topographic profiles deduced from the functions, an area of grooved terrain (lines 500-505, samples 550-650 on frame 20640.27 0060J2) using wide ranges of values of all the adjustable parameters in Hapke's new photometric function were analyzed.

Wilson, L.↗

The advanced X-ray Astrophysics Facility (AXAF)

NASA's Advanced X-ray Astrophysics Facility (AXAF) will be an orbiting X-ray observatory, designed to address fundamental questions in astronomy and astrophysics. AXAF is the successor to NASA's second High Energy Astronomy Observatory, the Einstein X-ray Observatory, which operated from 1978 to 1981. Like the Einstein, the AXAF will be built around a grazing incidence telescope capable of forming X-ray images. AXAF, however, will go far beyond the Einstein in capability having about 10 times the angular resolution, about 100 times the sensitivity for imaging, and up to about 1000 times the sensitivity for spectroscopy. The AXAF will operate in space for 15 years, and be maintained and refurbished by use of NASA's Space Station.

Weisskopf, M. C.↗

Small-Scale Interstellar Structure Toward the Open Cluster CHI Persei-Fuse II

The purpose of this study was to measure the physical conditions of gas along sight lines toward 6 stars in the core Chi Persei open cluster. These sight lines traverse gas in both the Orion and Perseus spiral arms of the Galaxy, at distances of 500 and 2000 pc, respectively. The stars have angular separations ranging from 45 to 280 arcsec; 60 arcsec corresponds to linear distances of 0.15 and 0.6 pc in the two arms. Thus, abundance variations in these observations would constitute evidence for small-scale variations in the properties of the interstellar medium. Ground-based Na I observations at high resolution (approx. 15 km/sec) toward 172 stars (including the 6 in this study) in the double open cluster h and Chi Persei have revealed complex spatial variation. These variations are especially evident in the gas at velocities of -40 and -55 km/sec, corresponding to the Perseus spiral arm. 21 cm observations of HI emission using the Low Resolution DRAO Survey, with a 12-arcmin beam, also show variations. Averaging the Na I apparent optical depth profiles of neighboring sight lines in order to mimic such a beam size reduces the variation, as compared to the individual Na I measurements, but still show variations larger than seen in the 21 cm profiles. Na I is not the dominant ionization state of Na in the interstellar medium. Thus, it is possible that the variations seen really trace physical structures in the interstellar medium, or they may simply result from variations in the radiation field seen by the gas, or be due to some other environmental circumstance. To distinguish among these possibilities in the present study we obtained FUSE spectra toward the 6 targets in order to measure the molecular hydrogen absorption profiles along these sight lines. The higher J states of H2 are populated by the ambient W radiation field, and thus can provide insight into the environment affecting the gas. If both the high and low J states reveal absorption line profiles with variations similar to that observed in Na I, this would indicate that the variations are due to real structures in the interstellar medium. On the other hand, if the only the high J profiles mimicked the Na I profiles, then the variations may be attributable to environmental effects. We found that the H2 profiles showed considerable variation over the 6 sight lines, and that the profiles, despite having somewhat lower velocity resolution, resemble the Na I profiles. Thus, it appears that the gas really does exhibit variations in physical structures along these sight lines. Useful follow-up work would be to obtain higher signal-to-noise FUSE observations of H2, since the present data are of only moderate quality, and to obtain data on additional targets in this double cluster, in order to map out in more detail the extent and magnitude of the small-scale variations.

Sonneborn, George↗

Comparisons of Bispectral and Polarimetric Retrievals of Marine Boundary Layer Cloud Microphysics: Case Studies Using a LES-Satellite Retrieval Simulator

Many passive remote-sensing techniques have been developed to retrieve cloud microphysical properties from satellite-based sensors, with the most common approaches being the bispectral and polarimetric techniques. These two vastly different retrieval techniques have been implemented for a variety of polar-orbiting and geostationary satellite platforms, providing global climatological data sets. Prior instrument comparison studies have shown that there are systematic differences between the droplet size retrieval products (effective radius) of bispectral (e.g., MODIS, Moderate Resolution Imaging Spectroradiometer) and polarimetric (e.g., POLDER, Polarization and Directionality of Earth's Reflectances) instruments. However, intercomparisons of airborne bispectral and polarimetric instruments have yielded results that do not appear to be systematically biased relative to one another. Diagnosing this discrepancy is complicated, because it is often difficult for instrument intercomparison studies to isolate differences between retrieval technique sensitivities and specific instrumental differences such as calibration and atmospheric correction. In addition to these technical differences the polarimetric retrieval is also sensitive to the dispersion of the droplet size distribution (effective variance), which could influence the interpretation of the droplet size retrieval. To avoid these instrument-dependent complications, this study makes use of a cloud remote-sensing retrieval simulator. Created by coupling a large-eddy simulation (LES) cloud model with a 1-D radiative transfer model, the simulator serves as a test bed for understanding differences between bispectral and polarimetric retrievals. With the help of this simulator we can not only compare the two techniques to one another (retrieval intercomparison) but also validate retrievals directly against the LES cloud properties. Using the satellite retrieval simulator, we are able to verify that at high spatial resolution (50 m) the bispectral and polarimetric retrievals are highly correlated with one another within expected observational uncertainties. The relatively small systematic biases at high spatial resolution can be attributed to different sensitivity limitations of the two retrievals. In contrast, a systematic difference between the two retrievals emerges at coarser resolution. This bias largely stems from differences related to sensitivity of the two retrievals to unresolved inhomogeneities in effective variance and optical thickness. The influence of coarse angular resolution is found to increase uncertainty in the polarimetric retrieval but generally maintains a constant mean value.

Miller, Daniel J.↗

Comparisons of Bispectral and Polarimetric Retrievals of Marine Boundary Layer Cloud Microphysics: Case Studies Using a LES- Satellite Retrieval Simulator

Many passive remote-sensing techniques have been developed to retrieve cloud microphysical properties from satellite-based sensors, with the most common approaches being the bispectral and polarimetric techniques. These two vastly different retrieval techniques have been implemented for a variety of polar-orbiting and geostationary satellite platforms, providing global climatological data sets. Prior instrument comparison studies have shown that there are systematic differences between the droplet size retrieval products (effective radius) of bispectral (e.g., MODIS, Moderate Resolution Imaging Spectroradiometer) and polarimetric (e.g., POLDER, Polarization and Directionality of Earth's Reflectances) instruments. However, intercomparisons of airborne bispectral and polarimetric instruments have yielded results that do not appear to be systematically biased relative to one another. Diagnosing this discrepancy is complicated, because it is often difficult for instrument intercomparison studies to isolate differences between retrieval technique sensitivities and specific instrumental differences such as calibration and atmospheric correction. In addition to these technical differences the polarimetric retrieval is also sensitive to the dispersion of the droplet size distribution (effective variance), which could influence the interpretation of the droplet size retrieval. To avoid these instrument-dependent complications, this study makes use of a cloud remote-sensing retrieval simulator. Created by coupling a large-eddy simulation (LES) cloud model with a 1-D radiative transfer model, the simulator serves as a test bed for understanding differences between bispectral and polarimetric retrievals. With the help of this simulator we can not only compare the two techniques to one another (retrieval intercomparison) but also validate retrievals directly against the LES cloud properties. Using the satellite retrieval simulator, we are able to verify that at high spatial resolution (50m) the bispectral and polarimetric retrievals are highly correlated with one another within expected observational uncertainties. The relatively small systematic biases at high spatial resolution can be attributed to different sensitivity limitations of the two retrievals. In contrast, a systematic difference between the two retrievals emerges at coarser resolution. This bias largely stems from differences related to sensitivity of the two retrievals to unresolved inhomogeneities in effective variance and optical thickness. The influence of coarse angular resolution is found to increase uncertainty in the polarimetric retrieval but generally maintains a constant mean value.

Miller, Daniel J.↗

Imaging large- and small-scale structures of the far ultraviolet background with the FAUST instrument

The FAUST telescope is an ultraviolet survey instrument that features a wide 8 deg field of view, 1-arcmin angular resolution, and a photon counting detector. Operating in the 1400-1800 A band, it will be sufficiently sensitive to detect blue m(v) = 17 objects in a single 20-minute night. The instrument is part of the ATLAS-1 shuttle mission, presently scheduled for flight in May 1991. A substantial number of high galactic latitude fields will be investigated, with particular emphasis on studies of the origin of the diffuse far UV background.

Lampton, M.↗

Improving Coastal Ocean Color Validation Capabilities through Application of Inherent Optical Properties (IOPs)

Understanding how the different components of seawater alter the path of incident sunlight through scattering and absorption is essential to using remotely sensed ocean color observations effectively. This is particularly apropos in coastal waters where the different optically significant components (phytoplankton, detrital material, inorganic minerals, etc.) vary widely in concentration, often independently from one another. Inherent Optical Properties (IOPs) form the link between these biogeochemical constituents and the Apparent Optical Properties (AOPs). understanding this interrelationship is at the heart of successfully carrying out inversions of satellite-measured radiance to biogeochemical properties. While sufficient covariation of seawater constituents in case I waters typically allows empirical algorithms connecting AOPs and biogeochemical parameters to behave well, these empirical algorithms normally do not hold for case I1 regimes (Carder et al. 2003). Validation in the context of ocean color remote sensing refers to in-situ measurements used to verify or characterize algorithm products or any assumption used as input to an algorithm. In this project, validation capabilities are considered those measurement capabilities, techniques, methods, models, etc. that allow effective validation. Enhancing current validation capabilities by incorporating state-of-the-art IOP measurements and optical models is the purpose of this work. Involved in this pursuit is improving core IOP measurement capabilities (spectral, angular, spatio-temporal resolutions), improving our understanding of the behavior of analytical AOP-IOP approximations in complex coastal waters, and improving the spatial and temporal resolution of biogeochemical data for validation by applying biogeochemical-IOP inversion models so that these parameters can be computed from real-time IOP sensors with high sampling rates. Research cruises supported by this project provides for collection and processing of seawater samples for biogeochemical (pigments, DOC and POC) and optical (CDOM and POM absorption coefficients) analyses to enhance our understanding of the linkages between in-water optical measurements (IOPs and AOPs) and biogeochemical constituents and to provide a more comprehensive suite of validation products.

Mannino, Antonio↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Radar for Monitoring Hurricanes from Geostationary Orbit

A document describes a scanning Doppler radar system to be placed in a geostationary orbit for monitoring the three-dimensional structures of hurricanes, cyclones, and severe storms in general. The system would operate at a frequency of 35 GHz. It would include a large deployable spherical antenna reflector, instead of conventional paraboloidal reflectors, that would allow the reflector to remain stationary while moving the antenna feed(s), and thus, create a set of scanning antenna beams without degradation of performance. The radar would have separate transmitting and receiving antenna feeds moving in spiral scans over an angular excursion of 4 from the boresight axis to providing one radar image per hour of a circular surface area of 5,300-km diameter. The system would utilize a real-time pulse-compression technique to obtain 300-m vertical resolution without sacrificing detection sensitivity and without need for a high-peakpower transmitter. An onboard data-processing subsystem would generate three-dimensional rainfall reflectivity and Doppler observations with 13-km horizontal resolution and line-of-sight Doppler velocity at a precision of 0.3 m/s.

Im, Eastwood↗

The angular diameters, effective temperatures, radii, and luminosities of 10 Wolf-Rayet stars

The effective temperature of a normal star with an absorption-line spectrum is a parameter which represents the total amount of radiative energy emerging from each square centimeter of surface of the star. Effective temperatures have been obtained for 10 Wolf-Rayet stars by means of ultraviolet energies determined from high-resolution International Ultraviolet Explorer (IUE) spectra and energies determined from observations made in the visible range. It is essential to use high-resolution IUE spectra in order to resolve the continuum from many emission lines which are present, particularly shortward of 1900 A. The results confirm what was found earlier, namely that the effective temperatures of Wolf-Rayet stars are similar to those of early B stars. The effective temperature of the central star of the planetary nebula BD 30 deg 3639, HD 184738, is found to be 18,000 K.

Underhill, A. B.↗

Development of a Telescope for Medium-Energy Gamma-Ray Astronomy

Since the launch of AGILE and FERMI, the scientific progress in high-energy (E(sub gamma) greater than approximately 200 MeV) gamma-ray science has been, and will continue to be dramatic. Both of these telescopes cover a broad energy range from approximately 20 MeV to greater than 10 GeV. However, neither instrument is optimized for observations below approximately 200 MeV where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. Hence, while significant progress from current observations is expected, there will nonetheless remain a significant sensitivity gap in the medium-energy (approximately 0.1-200 MeV) regime; the lower end of this range remains largely unexplored whereas the upper end will allow comparison with FERMI data. Tapping into this unexplored regime requires significant improvements in sensitivity. A major emphasis of modern detector development, with the goal of providing significant improvements in sensitivity in the medium-energy regime, focuses on high-resolution electron tracking. The Three-Dimensional Track Imager (3-DTI) technology being developed at GSFC provides high resolution tracking of the electron-positron pair from gamma-ray interactions from 5 to 200 MeV. The 3-DTI consists of a time projection chamber (TPC) and 2-D cross-strip microwell detector (MWD). The low-density and homogeneous design of the 3-DTI, offers unprecedented sensitivity by providing angular resolution near the kinematic limit. Electron tracking also enables measurement of gamma-ray polarization, a new tool to study astrophysical phenomenon. We describe the design, fabrication, and performance of a 30x30x30 cubic centimeters 3-DTI detector prototype of a medium-energy gamma-ray telescope.

Hunter, Stanley D.↗

Observation of an Anisotropy in the Galactic Cosmic Ray Arrival Direction at 400 TeV with IceCube

In this paper we report the first observation in the Southern hemisphere of an energy dependence in the Galactic cosmic ray anisotropy up to a few hundred TeV. This measurement was performed using cosmic ray induced muons recorded by the partially deployed IceCube observatory between May 2009 and May 2010. The data include a total of 33 x 10(exp 9) muon events with a median angular resolution of approx. 3 degrees. A sky map of the relative intensity in arrival direction over the Southern celestial sky is presented for cosmic ray median energies of 20 and 400 TeV. The same large-scale anisotropy observed at median energies around 20 TeV is not present at 400 TeV. Instead, the high energy skymap shows a different anisotropy structure including a deficit with a post-trial significance of -6.3 sigma. This anisotropy reveals a new feature of the Galactic cosmic ray distribution, which must be incorporated into theories of the origin and propagation of cosmic rays.

Abbasi, R.↗

Development of a Telescope for Medium-Energy Gamma-ray Astronomy

Since the launch of AGILE and FERMI, the scientific progress in high-energy (Eg greater than approximately 200 MeV) gamma-ray science has been, and will continue to be dramatic. Both of these telescopes cover a broad energy range from approximately 20 MeV to greater than 10 GeV. However, neither instrument is optimized for observations below approximately 200 MeV where many astrophysical objects exhibit unique, transitory behavior, such as spectral breaks, bursts, and flares. Hence, while significant progress from current observations is expected, there will nonetheless remain a significant sensitivity gap in the medium-energy (approximately 0.1-200 MeV) regime; the lower end of this range remains largely unexplored whereas the upper end will allow comparison with FERMI data. Tapping into this unexplored regime requires significant improvements in sensitivity. A major emphasis of modern detector development, with the goal of providing significant improvements in sensitivity in the medium-energy regime, focuses on high-resolution electron tracking. The Three-Dimensional Track Imager (3-DTI) technology being developed at GSFC provides high resolution tracking of the electron-positron pair from gamma-ray interactions from 5 to 200 MeV. The 3-DTI consists of a time projection chamber (TPC) and 2-D cross-strip microwell detector (MWD). The low-density and homogeneous design of the 3-DTI, offers unprecedented sensitivity by providing angular resolution near the kinematic limit. Electron tracking also enables measurement of gamma-ray polarization, a new tool to study astrophysical phenomenon. We describe the design, fabrication, and performance of a 30x30x30 cm3 3-DTI detector prototype of a medium-energy gamma-ray telescope.

Sunter, Stan↗

Optimal grazing incidence optics and its application to wide-field X-ray imaging

A class of high-resolution, efficient, and wide-field grazing incidence optics is discussed. Optical designs for searching efficiently for distant X-ray clusters are developed. It is shown that a rather general procedure exists for the design of an optical mission if well-defined scientific goals can be provided. Clusters of galaxies with an angular diameter of about 5 arcsec over a field of about 1 deg are resolved so that a comprehensive deep search is possible with a payload of 1/10 the linear dimensions of AXAF. By dropping the requirement for perfect on-axis imagery, searching within a suitably general class of telescope design, and optimizing a quantity directly related to the scientific requirement, it is shown that satisfactory designs do exist. The resulting telescope is shown to be no more difficult to fabricate than existing mirrors, and it can be nested.

Burrows, Christopher J.↗

Observation of Anisotropy in the Galactic Cosmic Ray Arrival Directions at 400 TEV With IceCube

In this paper we report the first observation in the Southern hemisphere of an energy dependence in the Galactic cosmic ray anisotropy up to a few hundred TeV. This measurement was performed using cosmic ray induced muons recorded by the partially deployed IceCube observatory between May 2009 and May 2010. The data include a total of 33x l0(epx 9) muon events with a median angular resolution of approx 3 degrees. A sky map of the relative intensity in arrival direction over the Southern celestial sky is presented for cosmic ray median energies of 20 and 400 Te V. The same large-scale anisotropy observed at median energies around 20 TeV is not present at 400 TeV. Instead, the high energy skymap shows a different anisotropy structure including a deficit with a post-trial significance of -6.30 sigma. This anisotropy reveals a new feature of the Galactic cosmic ray distribution, which must be incorporated into theories of the origin and propagation of cosmic rays.

Abbasi, R.↗

GLAST: Exploring Nature's Highest Energy Processes with the Gamma-ray Large Area Space Telescope

The Gamma-ray Large Area Space Telescope (GLAST) is an international and multi-agency space mission that will study the cosmos in the energy range 10 keV-300 GeV. Several successful exploratory missions in gamma-ray astronomy led to the Energetic Gamma Ray Experiment Telescope (EGRET) instrument on the Compton Gamma Ray Observatory (CGRO). Launched in 1991, EGRET made the first complete survey of the sky in the 30 MeV-10 GeV range. EGRET showed the high-energy gamma-ray sky to be surprisingly dynamic and diverse, with sources ranging from the sun and moon to massive black holes at large redshifts. Most of the gamma-ray sources detected by EGRET remain unidentified. In light of the discoveries with EGRET, the great potential of the next generation gamma-ray telescope can be appreciated. GLAST will have an imaging gamma-ray telescope vastly more capable than instruments flown previously, as well as a secondary instrument to augment the study of gamma-ray bursts. The main instrument, the Large Area Telescope (LAT), will have superior area, angular resolution, field of view, and deadtime that together will provide a factor of 30 or more advance in sensitivity, as well as provide capability for study of transient phenomena. The GLAST Burst Monitor (GBM) will have a field of view several times larger than the LAT and will provide spectral coverage of gamma-ray bursts that extends from the lower limit of the LAT down to 10 keV. The basic parameters of the GBM are compared to those of the Burst and Transient Source Experiment (BATSE) instrument on CGRO in Table 1-2. With the LAT and GBM, GLAST will be a flexible observatory for investigating the great range of astrophysical phenomena best studied in high-energy gamma rays. NASA plans to launch GLAST in late 2005.

Digel, Seth↗

Studying Star and Planet Formation with the Submillimeter Probe of the Evolution of Cosmic Structure

The Submillimeter Probe of the Evolution of Cosmic Structure (SPECS) is a far- infrared/submillimeter (40-640 micrometers) spaceborne interferometry concept, studied through the NASA Vision Missions program. SPECS is envisioned as a 1-km baseline Michelson interferometer with two 4- meter collecting mirrors. To maximize science return, SPECS will have three operational modes: a photometric imaging mode, an intermediate spectral resolution mode (R approximately equal to 1000-3000), and a high spectral resolution mode (R approximately equal to 3 x 10(exp 5)). The first two of these modes will provide information on all sources within a 1 arcminute field-of-view (FOV), while the the third will include sources in a small (approximately equal to 5 arcsec) FOV. With this design, SPECS will have angular resolution comparable to the Hubble Space Telescope (50 mas) and sensitivity more than two orders of magnitude better than Spitzer (5sigma in 10ks of approximately equal to 3 x 10(exp 7) Jy Hz). We present here some of the results of the recently-completed Vision Mission Study for SPECS, and discuss the application of this mission to future studies of star and planet formation.

Rinehart, Stephen A.↗

Technology Development for Nickel X-Ray Optics Enhancement

We are developing grazing-incidence x-ray optics for high-energy astrophysics using the electroform-nickel replication process. In this process, mirror shells are fabricated by replication off super-polished cylindrical mandrels. The mirrors fabricated using this process have a demonstrated optical performance at the level of 11-12 arc seconds resolution (HPD) for 30 keV x rays. Future missions demand ever higher angular resolutions and this places stringent requirements on the quality of the mandrels, the precision of the metrology, and the mounting and alignment of the mirror shells in their housings. A progress report on recent technology developments in all these areas will be presented along with a discussion on possible post fabrication, in-situ improvement of the x-ray mirrors quality.

Bubarev, Mikhail↗