Search NASA⌕ Search

SEARCH · Search NASA

Results for “highly selective”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

New Space Technology Development

Visitors from Moon Express, a privately funded commercial space company, will be visiting KSC Swamp Works. This presentation includes a high-level introduction to NASA and commercial partnerships, as well as brief background on the moon - what we used to think about it hundreds of years ago, and what we know today with advanced technologies.***This third part being added includes Swamp Works technical capabilities and has a high-level overview of a selection of projects.***

technology↗

Carbon Nanofiber Nanoelectrodes for Neural Stimulation and Chemical Detection: The Era of Smart Deep Brain Stimulation

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

bioinstrumentation↗

Carbon Nanofiber Nanoelectrodes for Neural Stimulation and Chemical Detection: The Era of "Smart" Deep Brain Stimulation

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

human body↗

Remote Sensing of Crystal Shapes in Ice Clouds

Ice crystals in clouds exist in a virtually limitless variation of geometries. The most basic shapes of ice crystals are columnar or plate-like hexagonal prisms with aspect ratios determined by relative humidity and temperature. However, crystals in ice clouds generally display more complex structures owing to aggregation, riming and growth histories through varying temperature and humidity regimes. Crystal shape is relevant for cloud evolution as it affects microphysical properties such as fall speeds and aggregation efficiency. Furthermore, the scattering properties of ice crystals are affected by their general shape, as well as by microscopic features such as surface roughness, impurities and internal structure. To improve the representation of ice clouds in climate models, increased understanding of the global variation of crystal shape and how it relates to, e.g., location, cloud temperature and atmospheric state is crucial. Here, the remote sensing of ice crystal macroscale and microscale structure from airborne and space-based lidar depolarization observations and multi-directional measurements of total and polarized reflectances is reviewed. In addition, a brief overview is given of in situ and laboratory observations of ice crystal shape as well as the optical properties of ice crystals that serve as foundations for the remote sensing approaches. Lidar depolarization is generally found to increase with increasing cloud height and to vary with latitude. Although this variation is generally linked to the variation of ice crystal shape, the interpretation of the depolarization remains largely qualitative and more research is needed before quantitative conclusions about ice shape can be deduced. The angular variation of total and polarized reflectances of ice clouds has been analyzed by numerous studies in order to infer information about ice crystal shapes from them. From these studies it is apparent that pristine crystals with smooth surfaces are generally inconsistent with the data and thus crystal impurity, distortion or surface roughness is prevalent. However, conclusions about the dominating ice shapes are often inconclusive and contradictory and are highly dependent on the limited selection of shapes included in the investigations. Since ice crystal optical properties are mostly determined by the aspect ratios of the crystal components and their microscale structure, it is advised that remote sensing applications focus on the variation of these ice shape characteristics, rather than on the macroscale shape or habit. Recent studies use databases with nearly continuous ranges of crystal component aspect ratio and-or roughness levels to infer the variation of ice crystal shape from satellite and airborne remote sensing measurements. Here, the rationale and results of varying strategies for the remote sensing of ice crystal shape are reviewed. Observed systematic variations of ice crystal geometry with location, cloud height and atmospheric state suggested by the data are discussed. Finally, a prospective is given on the future of the remote sensing of ice cloud particle shapes.

clouds↗

Carbon Nanofiber Electrode Array for Neurochemical Monitoring

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report using vertically aligned CNF as neurotransmitter recording electrodes for application in a smart deep brain stimulation (DBS) device. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Digital Image Correlation Data Processing and Analysis Techniques to Enhance Test Data Assessment and Improve Structural Simulations

The NASA Shell Buckling Knockdown Factor Project (SBKF) was established in 2007 by the NASA Engineering and Safety Center (NESC) with the primary goal to develop new analysis-based buckling design factors (a.k.a. knockdown factors) and high-fidelity buckling simulations for selected launch-vehicle-like cylindrical shell structures. A series of tests are being conducted on large-scale metallic and composite cylindrical shells in order to provide validation data for these new factors and simulations. However, the validation of these new factors and simulations is quite demanding and requires test data that is commensurate with their fidelity. Traditional instrumentation, such as linear variable displacement transducers (LVDTs) and electrical-resistance strain gages serve a critical role in providing accurate displacement and strain measurements in these tests, but only allow for data to be recorded at a select number of point locations and are not sufficient to provide all the necessary validation data. Advanced measurement technologies can be used effectively to complement traditional instrumentation and gather additional data required to validate these structural simulations. In particular, three-dimensional digital image correlation (DIC) was implemented during SBKF cylinder testing to characterize the full-field displacement and strain behavior. Commercially available VIC-3DTM software and user-written data processing scripts were used to generate valuable data and insight into the complex buckling response of the cylinders that otherwise would be impossible to gather using traditional instrumentation. In addition, the measured data from DIC was used to verify measured test data obtained from other instrumentation, enhance test and analysis correlation, and help identify the root cause of anomalous test results that may have gone unexplained if only traditional instrumentation was used. Selected test results that demonstrate the use of DIC on the SBKF cylinders are presented and a portion of the data processing methods are described.

Gardner, Nathaniel W.↗

Science Diplomacy Through Cities: Applying NASA Earth Observations at the Urban Scale

NASA's scientific expertise and data products are enhancing cities' environmental monitoring activities by pioneering applications of remote sensing and model-based Earth Observations at the urban scale. The above activities have greatly benefitted from engaging stakeholders and city practitioners from the start. Further, NASA's collaborations with cities have: Advanced NASA science, in testing new products and validating of satellite datasets, while meeting the needs of city governments. Broadened Rio de Janeiro's regional viewpoint and strengthened its relationships with neighboring cities. Scientific collaborations with cities benefit from: Selecting city partners with a high level of technical capacity and willing to make strong investments in joint projects. Sustained communication and face-to-face interactions. Well-defined deliverables, with dedicated resources and personnel. Pairing global datasets and projections with in situ measurements and local knowledgeSensitivity to local working culture and politics.

urban environment↗

Nanobiotechnology in Space Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Carbon Nanomaterials for Biosensing Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable “smart” therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Carbon Nanomaterials for Biosensing Applications↗

Carbon Nanofiber Nanoelectrode Arrays for Neural Implant Devices

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

carbon nanotubes↗

Wind Tunnel Experiment of Microjet-based Flow Control on a Multi-Element High-Lift Airfoil

A wind tunnel model was designed, manufactured, and tested to evaluate the potential of active aerodynamic flow control for multi-element airfoils. The active flow control system involves so-called microjets –small, low momentum, normal to the surface jets located near the trailing edge of the flap –for controlling the lift and improving the aerodynamic performance characteristics of airplane high-lift systems. The configuration selected for this test is the NLR7301 two-element airfoil and it was tested in the Oran W. Nicks Low-Speed Wind Tunnel at Texas A&M University at a chord Reynolds number of 2.0 million and Machnumber of 0.10. This paper presents wind tunnel results for the NLR7301 in the Flap 20 and Flap 30 configurations. The wind tunnel results include surface pressure distributions, lift and pitching moment, and flow visualizations.The results of this experiment validate the effectiveness of the microjet with regards to control of lift in the linear regime for multi-element airfoils.

ARMD↗

Regenerative Fuel Cell Systems for Lunar Surface Applications

A discrete Regenerative Fuel Cell (RFC), comprised of a Proton Exchange Membrane (PEM) Fuel Cell (FC) system integrated with a PEM Electrolyzer (EZ) system, can provide energy conversion and storage options for applications where batteries are not practical. This includes missions on the lunar surface where long charge and discharge periods result in extremely high battery system mass for sufficient energy storage. While both PEM FC and PEM EZ are mature terrestrial technologies, there is still a lot of development needed for aerospace applications. Integrating the PEM FC and PEM EZ systems together requires the integration of multiple thermal, fluid, and electrical subsystems, increasing the complexity of the overall RFC system. Additionally, Balance of Plant (BoP) components and subsystems play a crucial role in the effective performance to maximize the RFC round trip efficiency. This presentation will give a high-level overview of RFCs, select BoP components including a catalytic recombiner and gas drying equipment, and the current testing that is being done on the RFC project at NASA GRC.

Jessica Cashman↗

Investigation of Physical Mechanisms for Jet Noise Reduction by Plug Nozzle Porosity

This paper presents the results of a computational study on porous-plug nozzles for their eventual application in reducing takeoff noise levels for supersonic civil transport. The study explores a wide range of porous-plug geometries, encompassing variations in hole size, plug length and porosity. Computational fluid dynamics (CFD) analyses are employed in concert with an advanced automated mesh refinement (AMR) scheme, Sketch-to-Solution (S2S), to investigate porous plug nozzle design strategies that may diminish shock strength, broad-band shock noise (BBSN), flow separation, and other undesirable characteristics associated with high takeoff noise levels. A selected subset of the porous-plug nozzles that were analyzed computationally were manufactured at subscale using stereolithography 3D printing. These nozzles were tested experimentally, obtaining far-field noise spectral data and schlieren flow visualization pictures. Detailed comparisons between CFD predictions and experimental results were conducted. These comparisons focus on gaining a better understanding of the underlying physical mechanisms responsible for noise reduction with the porous plugs relative to corresponding solid plugs.

computational fluid dynamics↗

Investigation of Physical Mechanisms for Jet Noise Reduction by Plug Nozzle Porosity

This paper presents the results of a computational study on porous-plug nozzles for their eventual application in reducing takeoff noise levels for supersonic civil transport. The study explores a wide range of porous-plug geometries, encompassing variations in hole size, plug length and porosity. Computational fluid dynamics (CFD) analyses are employed in concert with an advanced automated mesh refinement (AMR) scheme, Sketch-to-Solution (S2S), to investigate porous plug nozzle design strategies that may diminish shock strength, broad-band shock noise (BBSN), flow separation, and other undesirable characteristics associated with high takeoff noise levels. A selected subset of the porous-plug nozzles that were analyzed computationally were manufactured at subscale using stereolithography 3D printing. These nozzles were tested experimentally, obtaining far-field noise spectral data and schlieren flow visualization pictures. Detailed comparisons between CFD predictions and experimental results were conducted. These comparisons focus on gaining a better understanding of the underlying physical mechanisms responsible for noise reduction with the porous plugs relative to corresponding solid plugs.

Nozzles↗

Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F.)

The Standalone Hazard Evaluation From Instrument Findings (SHERIF) system is a set of novel algorithms and associated framework designed to support the generation of Digital Elevation Maps (DEMs) from multiple LiDAR scans and perform Hazard Detection (HD) and Safe Site Identification (SSI) with no dependencies on other onboard systems. SHERIF can employ several techniques to perform robust 3D keypoint extraction and Point Cloud registration (PCR) on disparate LiDAR scans of a planetary surface to generate a DEM which evolves over the course of a trajectory. The framework also supports a variety of Hazard Detection and Safe Site Identification algorithms which can be applied to the evolving DEM being produced. SHERIF features a robust and modular construction, allowing the user a high degree of flexibility in selecting and implementing whichever keypoint identificaiton, PCR and HD/SSI algorithms they may prefer, while maintaining the data products and sensor independence of the core SHERIF framework. SHERIF was recently evaluated via simulation and hardware-in-the-loop experimental testing at NASA Johnson Space Center.

hazard detection↗

Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F.)

The Standalone Hazard Evaluation From Instrument Findings (SHERIF) system is a set of novel algorithms and associated framework designed to support the generation of Digital Elevation Maps (DEMs) from multiple LiDAR scans and perform Hazard Detection (HD) and Safe Site Identification (SSI) with no dependencies on other onboard systems. SHERIF can employ several techniques to perform robust 3D keypoint extraction and Point Cloud registration (PCR) on disparate LiDAR scans of a planetary surface to generate a DEM which evolves over the course of a trajectory. The framework also supports a variety of Hazard Detection and Safe Site Identification algorithms which can be applied to the evolving DEM being produced. SHERIF features a robust and modular construction, allowing the user a high degree of flexibility in selecting and implementing whichever keypoint identificaiton, PCR and HD/SSI algorithms they may prefer, while maintaining the data products and sensor independence of the core SHERIF framework. SHERIF was recently evaluated via simulation and hardware-in-the-loop experimental testing at NASA Johnson Space Center.

hazard detection↗

X-Hab 2026: LiDAR-Powered Autonomous Charging Service Capability for Surface Rovers and Systems

This document details the timeline of the LiDAR-Powered Autonomous Charging Service Capability for Surface Rovers and Systems project, initiated by the Fall 2025 semester class and completed by the Spring 2026 semester class. This project focuses on developing a fully autonomous system composed of a mobile surface rover and an induction charging station with a robotic arm, both controlled by their own NVIDIA Jetson Orin Nano. Structural improvements to the rover suspension system and body eliminated excessive camber, reduced stress and strain on the plexiglass body, and improved maneuverability and durability of the rover. The charging station robotic arm was fully redesigned to increase reach while minimizing weight and increasing misalignment tolerance during docking on uneven terrain. Electrical system improvements addressed previous torque and power limitations of both the rover and charging station arm. High-torque servo motors were selected based on updated calculations which incorporated terrain slope and Factor of Safety, enabling zero-point turning for the rover and increased payload capacity of the charging station arm. Significant progress was made in autonomy and perception. The rover now employs 3D LiDAR and SLAM mapping for localization, mapping, and path planning. The Battery Monitoring System (BMS) was created to coordinate battery management between the rover and charging station. The BMS provides continuous monitoring of battery state of charge, temperature, current, and will enable the autonomous initiation, execution, and termination of the charging cycle via Bluetooth communication. Testing of the WIBOTIC induction charging system demonstrated reliable power transfer under both aligned and misaligned conditions. This project demonstrated the ability of an autonomously navigating surface rover to independently plan a path to the charging station, dock, and the charging station to autonomously deploy a robotic charging arm and initiate charging of the rover. This work details the progress made to demonstrate the feasibility of autonomous surface rover navigation and recharging systems.

Megan Steele↗

The NuSTAR Extragalactic Survey: A First Sensitive Look at the High-Energy Cosmic X-Ray Background Population

We report on the first 10 identifications of sources serendipitously detected by the Nuclear Spectroscopic Telescope Array (NuSTAR) to provide the first sensitive census of the cosmic X-ray background source population at approximately greater than 10 keV. We find that these NuSTAR-detected sources are approximately 100 times fainter than those previously detected at approximately greater than 10 keV and have a broad range in redshift and luminosity (z = 0.020-2.923 and L(sub 10-40 keV) approximately equals 4 × 10(exp 41) - 5 × 10(exp 45) erg per second; the median redshift and luminosity are z approximately equal to 0.7 and L(sub 10-40 keV) approximately equal to 3 × 10(exp 44) erg per second, respectively. We characterize these sources on the basis of broad-band approximately equal to 0.5 - 32 keV spectroscopy, optical spectroscopy, and broad-band ultraviolet-to-mid-infrared spectral energy distribution analyses. We find that the dominant source population is quasars with L(sub 10-40 keV) greater than 10(exp 44) erg per second, of which approximately 50% are obscured with N(sub H) approximately greater than 10(exp 22) per square centimeters. However, none of the 10 NuSTAR sources are Compton thick (N(sub H) approximately greater than 10(exp 24) per square centimeters) and we place a 90% confidence upper limit on the fraction of Compton-thick quasars (L(sub 10-40 keV) greater than 10(exp 44) erg per second) selected at approximately greater than 10 keV of approximately less than 33% over the redshift range z = 0.5 - 1.1. We jointly fitted the rest-frame approximately equal to 10-40 keV data for all of the non-beamed sources with L(sub 10-40 keV) greater than 10(exp 43) erg per second to constrain the average strength of reflection; we find R less than 1.4 for gamma = 1.8, broadly consistent with that found for local active galactic nuclei (AGNs) observed at approximately greater than 10 keV. We also constrain the host-galaxy masses and find a median stellar mass of approximately 10(exp 11) solar mass, a factor approximately 5 times higher than the median stellar mass of nearby high-energy selected AGNs, which may be at least partially driven by the order of magnitude higher X-ray luminosities of the NuSTAR sources. Within the low source-statistic limitations of our study, our results suggest that the overall properties of the NuSTAR sources are broadly similar to those of nearby high-energy selected AGNs but scaled up in luminosity and mass.

Spectroscopic↗