Search NASA⌕ Search

SEARCH · Search NASA

Results for “imagers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Fresnel zone plate point spread function approximation for zeroth order mitigation in millimetric field of view x-ray imaging

High spatial and temporal resolution x-ray radiography images are required at the National Ignition Facility (NIF) for high-energy density experiments. One technique that is in development to achieve the required resolution uses Fresnel zone plate (FZP) optics to image an object that is backlit by an x-ray source. The multiple FZP diffraction orders do not focus on the same plane, which increases the background and reduces the contrast. Understanding the point spread function of the different diffraction orders will allow the prediction of the expected background using simulations. We find that the two-dimensional point spread function of the FZP can be approximated by the addition of a sharp Gaussian with a disk. This allowed for the estimation of the background in NIF experimental images of Rayleigh–Taylor spikes and their interpretation. An alternative design of FZP is discussed to allow the inclusion of a zeroth order blocker to reduce the background.

Do, A. (ORCID:0000000174372147)↗

High-speed Synchrotron X-ray Imaging of Laser Powder Bed Fusion Process

In additive manufacturing (AM) processes, materials are selectively added in layer-wise fashion to build three-dimensional objects. This approach provides several advantages over conventional manufacturing, including the ability to manufacture complex parts, design flexibility, shorter lead times, reduced inventory of spares, and on-demand manufacturing [1]. With these advantages, applications of AM are increasing rapidly in the medical, aerospace, automobile, and defense industries [2, 3]. Currently, laser powder bed fusion (LPBF) is the most extensively used AM technique for manufacturing metal parts. In a typical LPBF process, a high-power laser beam is scanned across a thin layer of powder, melting and subsequently fusing it to the previous layer. Highly transient interactions between the laser, powder particles, and the bottom layer lead to defects in the AM materials. These defects include porosity, residual stresses, surface roughness, and undesirable microstructures [1, 4]. Additionally, several in situ techniques have been developed to capture these interactions in real time, including high-speed visible light and infra-red imaging [5]. However these techniques are limited to surface observations. Most of the important phenomena that govern the quality of the AM parts, such as dynamics of the vapor depression and melt pool, occur sub-surface and hence cannot be captured using traditional optical techniques. Recently, a synchrotron-based high-speed X-ray imaging technique has been developed to record the sub-surface dynamics of metallic materials during the LPBF process. The unprecedented spatial and temporal resolutions afforded by the synchrotron sources allow direct observation of many important phenomena in AM for the first time [6–9]. Further, high-speed X-ray diffraction and optical imaging techniques are also being applied to capture the crystallographic and thermal information of the material, respectively, as they undergo melting, solidification, and cooling [6, 9]. In this contribution, we introduce the recent developments at the Advanced Photon Source (APS) for in situ and operando study of LPBF processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetized Plasma for Reconfigurable Subdiffraction Imaging

We show that magnetized plasma with appropriately designed parameters supports nearly diffractionless propagation of electromagnetic waves along the direction of the applied magnetic field, arising from their unbounded equifrequency contour in the magnetized plasma. Such a unique feature can be utilized to construct subdiffraction imaging devices, which is confirmed by detailed numerical investigations. Subdiffraction imaging devices based on magnetic plasma do not require microfabrication normally entailed by construction of metamaterials; more importantly, they can be dynamically reconfigured by tuning the applied magnetic field or the plasma density, and therefore they represent a facile and powerful route for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-BRF-14: Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation

Purpose: Artifacts can reduce the quality of dose re-calculations on CBCT scans during a treatment. The aim of this project is to correct the CBCT images in order to allow for more accurate and exact dose calculations in the case of a translation of the tumor in prostate cancer. Methods: Our approach is to develop strategies based on deformable image registration algorithms using the elastix software (Klein et al., 2010) to register the treatment planning CT on a daily CBCT scan taken during treatment. Sets of images are provided by a 3D deformable phantom and comprise two CT and two CBCT scans: one of both with the reference anatomy and the others with known deformations (i.e. translations of the prostate). The reference CT is registered onto the deformed CBCT and the deformed CT serves as the control for dose calculation accuracy. The planned treatment used for the evaluation of dose calculation is a 2-Gy fraction prescribed at the location of the reference prostate and assigned to 7 rectangular fields. Results: For a realistic 0.5-cm translation of the prostate, the relative dose discrepancy between the CBCT and the CT control scan at the prostate's centroid is 8.9 ± 0.8 % while dose discrepancy between the registered CT and the control scan lessens to −2.4 ± 0.8 %. For a 2-cm translation, clinical indices like the V90 and the D100 are more accurate by 0.7 ± 0.3 % and 8.0 ± 0.5 cGy respectively when using registered CT than when using CBCT for dose calculation. Conclusion: The results show that this strategy gives doses in agreement within a few percents with those from calculations on actual CT scans. In the future, various deformations of the phantom anatomy will allow a thorough characterization of the registration strategies needed for more complex anatomies.

60 APPLIED LIFE SCIENCES↗

Catalyst-layer ionomer imaging of fuel cells

Investigation of membrane/electrode assembly (MEA) microstructure has become an essential step to optimize the MEA components and manufacturing processes or to study the MEA degradation. For these investigations, transmission electron microscopy (TEM) is a tool of choice as it provides direct imaging of the different components. TEM is then widely used for analyzing the catalyst nanoparticles and their carbon support. However, the ionomer inside the electrode is more difficult to be imaged. The difficulties come from the fact that the ionomer forms an ultrathin layer surrounding the carbon particles and in addition, these two components, having similar density, present no difference in contrast. In this paper, we show how the recent progresses in TEM techniques as spherical aberration (Cs) corrected HRTEM, electron tomography and X-EDS elemental mapping provide new possibilities for imaging this ionomer network and consequently to study its degradation.

30 DIRECT ENERGY CONVERSION↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

Commercial Opportunity Cancer Imaging Ultrasonics-based methods for cancer imaging & diagnostics

Breast cancer is the most frequently diagnosed cancer in U.S. women and prostate cancer is the second leading cause of cancer death in American men. X-ray mammography is the principal breastcancer screening tool available, but its false positive rate is more than 80%. Prostate-specific antigen (PSA) screening, which measures the level of PSA in a man’s blood, is no longer recommended by the U.S. task force for prostate-cancer screening. Los Alamos National Security (LANS) has developed novel imaging technologies for early-stage cancer detection based on advanced ultrasonic analyses. In particular, Los Alamos has developed ultrasoundwaveform tomography and related super-resolution ultrasound- imaging technologies that can provide significantly improved image resolution and characterization of early-stage cancers and thus potentially save lives.

60 APPLIED LIFE SCIENCES↗

Limited-view 3D Imaging Technology or “LV 3D Imaging” Technology Assessment

Limited View 3D or “LV 3D” imaging is important because it addresses a technology gap that has life, time, radiation dose and monetary-saving impacts. It provides something that currently does not exist and its potential products open a variety of technology domains in which SRNL could become competitive in. It can become a low cost, safer and alternative approach to conducting what is commonly referred to as computer tomographic imaging. This project develops a bucket list of technologies that will be needed to develop a portable system for conducting LV 3D imaging.

47 OTHER INSTRUMENTATION↗

Limited-view 3D Imaging Technology or “LV 3D Imaging” Technology Assessment

Limited View 3D or “LV 3D” imaging is important because it addresses a tech nology gap that has life, time, radiation dose and monetary-saving impacts. It provides something that currently does not exist and its potential products open a variety of technology domains in which SRNL could become competitive in. It can become a low cost, safer and alternative approach to conducting what is commonly referred to as computer tomographic imaging. This project develops a bucket list of technologies that will be needed to develop a portable system for conducting LV 3D imaging.

47 OTHER INSTRUMENTATION↗

Cloud Particle Imager (CPI) and 3-View Cloud Particle Imager (3V-CPI) Instrument Handbook

The cloud particle imager (CPI) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring the concentration and size of cloud droplet and ice crystals. Hydrometeors entering the tube will be detected by a system of two continuous wave lasers that are perpendicular to each other, monitoring the sample volume. When a hydrometeor obscures both laser beams it is inside the sample volume and a third laser is triggered to illuminate the hydrometeor and a camera records a two-dimensional image. The CPI records images with a resolution of 2.3 μm. Since the camera has 1024 x 1024 pixels, the maximum detectable size is 2.3 mm x 2.3 mm.

54 ENVIRONMENTAL SCIENCES↗

Combining hyperspectral imaging and micro-X-ray fluorescence imaging methods for ultra-high-resolution biogeochemical analysis

Current non-destructive methods for high-resolution geochemical imaging open new avenues for high-resolution paleoenvironmental research. We discuss how two of these methods, hyperspectral imaging and micro-X-ray fluorescence imaging, can be combined for organic and inorganic geochemical analyses at a micrometer scale.

Zander, Paul [Lawrence Livermore National Laborato↗

Supplementary material for manuscript: Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

This data contains the supplemental information that will be accessible to the public from the paper “Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives”. The data set contains the reconstructed slices for the 3D images of three different high explosives including: HMX-HTPB, PBX 9501 and PBX 9502. The data sets are folders of reconstructed tiffs showing the microstructure (crystals, binder, voids) and a segmented data set of each. Finally, a .gif movie is also present that plays the slices sequentially. The folders contain the voxel size information. See the manuscript for more details.

36 MATERIALS SCIENCE↗

THE LEECH EXOPLANET IMAGING SURVEY: CHARACTERIZATION OF THE COLDEST DIRECTLY IMAGED EXOPLANET, GJ 504 b, AND EVIDENCE FOR SUPERSTELLAR METALLICITY

As gas giant planets and brown dwarfs radiate away the residual heat from their formation, they cool through a spectral type transition from L to T, which encompasses the dissipation of cloud opacity and the appearance of strong methane absorption. While there are hundreds of known T-type brown dwarfs, the first generation of directly imaged exoplanets were all L type. Recently, Kuzuhara et al. announced the discovery of GJ 504 b, the first T dwarf exoplanet. GJ 504 b provides a unique opportunity to study the atmosphere of a new type of exoplanet with a ∼500 K temperature that bridges the gap between the first directly imaged planets (∼1000 K) and our own solar system's Jupiter (∼130 K). We observed GJ 504 b in three narrow L-band filters (3.71, 3.88, and 4.00 μm), spanning the red end of the broad methane fundamental absorption feature (3.3 μm) as part of the LBTI Exozodi Exoplanet Common Hunt (LEECH) exoplanet imaging survey. By comparing our new photometry and literature photometry with a grid of custom model atmospheres, we were able to fit GJ 504 b's unusual spectral energy distribution for the first time. We find that GJ 504 b is well fit by models with the following parameters: T{sub eff} = 544 ± 10 K, g < 600 m s{sup −2}, [M/H] = 0.60 ± 0.12, cloud opacity parameter of f{sub sed} = 2–5, R = 0.96 ± 0.07 R{sub Jup}, and log(L) = −6.13 ± 0.03 L{sub ⊙}, implying a hot start mass of 3–30 M{sub jup} for a conservative age range of 0.1–6.5 Gyr. Of particular interest, our model fits suggest that GJ 504 b has a superstellar metallicity. Since planet formation can create objects with nonstellar metallicities, while binary star formation cannot, this result suggests that GJ 504 b formed like a planet, not like a binary companion.

79 ASTRONOMY AND ASTROPHYSICS↗