A fast marine sewage detection method for remote-sensing image

This paper presents an effective method for marine sewage detection from a remote-sensing image. It is inspired by the Grab-Cut mechanism that iterative estimation and incomplete labeling allow a considerably reduced degree of user interaction for a given quality of result. By establishing the relationship between the color feature and the object seeds, we first model object and background with Gaussian mixture model, respectively, followed by iteratively updating the parameter of model to decline the energy function. To improve the computation efficiency, we propose to extend the region of interest as background. The proposed method accounts for not only the effect of color feature, but also the geographical information. The experimental results demonstrate that the proposed method is more reliable in marine sewage detection compared to other state-of-the-art methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifies the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel component to automatically verify image acquisition parameters and automated adherence to specifications. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant support from: U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VI-IRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project athttps://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VIIRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project at https://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WE-FG-207B-05: Iterative Reconstruction Via Prior Image Constrained Total Generalized Variation for Spectral CT

Purpose: To investigate iterative reconstruction via prior image constrained total generalized variation (PICTGV) for spectral computed tomography (CT) using fewer projections while achieving greater image quality. Methods: The proposed PICTGV method is formulated as an optimization problem, which balances the data fidelity and prior image constrained total generalized variation of reconstructed images in one framework. The PICTGV method is based on structure correlations among images in the energy domain and high-quality images to guide the reconstruction of energy-specific images. In PICTGV method, the high-quality image is reconstructed from all detector-collected X-ray signals and is referred as the broad-spectrum image. Distinct from the existing reconstruction methods applied on the images with first order derivative, the higher order derivative of the images is incorporated into the PICTGV method. An alternating optimization algorithm is used to minimize the PICTGV objective function. We evaluate the performance of PICTGV on noise and artifacts suppressing using phantom studies and compare the method with the conventional filtered back-projection method as well as TGV based method without prior image. Results: On the digital phantom, the proposed method outperforms the existing TGV method in terms of the noise reduction, artifacts suppression, and edge detail preservation. Compared to that obtained by the TGV based method without prior image, the relative root mean square error in the images reconstructed by the proposed method is reduced by over 20%. Conclusion: The authors propose an iterative reconstruction via prior image constrained total generalize variation for spectral CT. Also, we have developed an alternating optimization algorithm and numerically demonstrated the merits of our approach. Results show that the proposed PICTGV method outperforms the TGV method for spectral CT.

60 APPLIED LIFE SCIENCES↗

Fast Ultrasonic Imaging with Total Focusing Method (TFM) for Inspection of Additively Manufactured Polymer Composite Component

Ultrasonic adaptive imaging based on the phased-array technology and the synthetic focusing algorithm Total Focusing Method (TFM) is proposed for fast ultrasonic nondestructive evaluation of additively manufactured composite materials. Nondestructive evaluation and inspection of additively manufactured parts and components are necessary for quality assurance of the materials. Effective detection of defects and anomalies in manufactured parts prevents extra cost and production time. However, there are several limitations encountered when using conventional methods of nondestructive inspection for as built additively manufactured parts due to surface conditions and geometrical complexity. Post-processing operations, such as machining, are usually needed to detect possible defects such as layer disband, micro-cracks, and voids in the composite parts. The capability of aperture focusing in phased array ultrasonic methods provides the opportunity for the adjustment of the delay laws in ultrasonic beams and reduces the noise and beam distortion for better imaging. An additively manufactured carbon fiber reinforced Acrylonitrile Butadiene Styrene (ABS) composite sample with artificial side and bottom-drilled holes of different sizes, used to represent defects, was successfully inspected using the Total Focusing Method (TFM). Unlike conventional ultrasonic techniques, results show a promising way to provide inspection of as built additively manufactured composite parts with rough surface finishes. The proposed method helps to decrease inspection time and eliminate extra machining and preparation costs.

Taheri, Hossein↗

Tools and Methods for the Registration and Fusion of Remotely Sensed Data

Tools and methods for image registration were reviewed. Methods for the registration of remotely sensed data at NASA were discussed. Image fusion techniques were reviewed. Challenges in registration of remotely sensed data were discussed. Examples of image registration and image fusion were given.

Goshtasby, Arthur Ardeshir↗

Visualizing dispersive features in 2D image via minimum gradient method

Here, we developed a minimum gradient based method to track ridge features in a 2D image plot, which is a typical data representation in many momentum resolved spectroscopy experiments. Through both analytic formulation and numerical simulation, we compare this new method with existing DC (distribution curve) based and higher order derivative based analyses. We find that the new method has good noise resilience and enhanced contrast especially for weak intensity features and meanwhile preserves the quantitative local maxima information from the raw image. An algorithm is proposed to extract 1D ridge dispersion from the 2D image plot, whose quantitative application to angle-resolved photoemission spectroscopy measurements on high temperature superconductors is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method and apparatus to obtain limited angle tomographic images from stationary gamma cameras

A nuclear imaging system and method for performing three-dimensional imaging of anatomical structures. The system and method includes two or more gamma ray detectors each used in combination with a variable-slant hole collimator. The detectors are positioned in close proximity to, or in contact with, the structure being imaged. The detectors remain in a stationary position during the data collection process. An imaging or reconstruction method is then used to reconstruct a three-dimensional image from the data derived from the detectors.

Kross, Brian J.↗

Flexible radioluminescence imaging for FDG-guided surgery

Purpose: Flexible radioluminescence imaging (Flex-RLI) is an optical method for imaging {sup 18}F-fluorodeoxyglucose (FDG)-avid tumors. The authors hypothesize that a gadolinium oxysulfide: terbium (GOS:Tb) flexible scintillator, which loosely conforms to the body contour, can enhance tumor signal-to-background ratio (SBR) compared with RLI, which utilizes a flat scintillator. The purpose of this paper is to characterize flex-RLI with respect to alternative modalities including RLI, beta-RLI (RLI with gamma rejection), and Cerenkov luminescence imaging (CLI). Methods: The photon sensitivity, spatial resolution, and signal linearity of flex-RLI were characterized with in vitro phantoms. In vivo experiments utilizing 13 nude mice inoculated with the head and neck (UMSCC1-Luc) cell line were then conducted in accordance with the institutional Administrative Panel on Laboratory Animal Care. After intravenous injection of {sup 18}F-FDG, the tumor SBR values for flex-RLI were compared to those for RLI, beta-RLI, and CLI using the Wilcoxon signed rank test. Results: With respect to photon sensitivity, RLI, beta-RLI, and flex-RLI produced 1216.2, 407.0, and 98.6 times more radiance per second than CLI. Respective full-width half maximum values across a 0.5 mm capillary tube were 6.9, 6.4, 2.2, and 1.5 mm, respectively. Flex-RLI demonstrated a near perfect correlation with {sup 18}F activity (r = 0.99). Signal uniformity for flex-RLI improved after more aggressive homogenization of the GOS powder with the silicone elastomer during formulation. In vivo, the SBR value for flex-RLI (median 1.29; interquartile range 1.18–1.36) was statistically greater than that for RLI (1.08; 1.02–1.14; p < 0.01) by 26%. However, there was no statistically significant difference in SBR values between flex-RLI and beta-RLI (p = 0.92). Furthermore, there was no statistically significant difference in SBR values between flex-RLI and CLI (p = 0.11) in a more limited dataset. Conclusions: Flex-RLI provides high quality images with SBRs comparable to those from CLI and beta-RLI in a single 10 s acquisition.

60 APPLIED LIFE SCIENCES↗

TH-AB-207A-05: A Fully-Automated Pipeline for Generating CT Images Across a Range of Doses and Reconstruction Methods

Purpose: To evaluate the robustness of CAD or Quantitative Imaging methods, they should be tested on a variety of cases and under a variety of image acquisition and reconstruction conditions that represent the heterogeneity encountered in clinical practice. The purpose of this work was to develop a fully-automated pipeline for generating CT images that represent a wide range of dose and reconstruction conditions. Methods: The pipeline consists of three main modules: reduced-dose simulation, image reconstruction, and quantitative analysis. The first two modules of the pipeline can be operated in a completely automated fashion, using configuration files and running the modules in a batch queue. The input to the pipeline is raw projection CT data; this data is used to simulate different levels of dose reduction using a previously-published algorithm. Filtered-backprojection reconstructions are then performed using FreeCT-wFBP, a freely-available reconstruction software for helical CT. We also added support for an in-house, model-based iterative reconstruction algorithm using iterative coordinate-descent optimization, which may be run in tandem with the more conventional recon methods. The reduced-dose simulations and image reconstructions are controlled automatically by a single script, and they can be run in parallel on our research cluster. The pipeline was tested on phantom and lung screening datasets from a clinical scanner (Definition AS, Siemens Healthcare). Results: The images generated from our test datasets appeared to represent a realistic range of acquisition and reconstruction conditions that we would expect to find clinically. The time to generate images was approximately 30 minutes per dose/reconstruction combination on a hybrid CPU/GPU architecture. Conclusion: The automated research pipeline promises to be a useful tool for either training or evaluating performance of quantitative imaging software such as classifiers and CAD algorithms across the range of acquisition and reconstruction parameters present in the clinical environment. Funding support: NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Methods and systems of proteome analysis and imaging

Provided herein are methods and systems for proteome analysis that are at least partially automated and/or performed robotically. In some aspects, the methods and systems described herein can rapidly and efficiently provide protein identification of each of the proteins from a proteome, or a complement of proteins, obtained from extremely small amounts of biological samples. The identified proteins can be imaged quantitatively over a spatial region. Automation and robotics facilitates the throughput of the methods and systems, which enables protein imaging and/or rapid proteome analysis.

Piehowski, Paul D.↗

Deep learning methods for event verification and image re-purposing detection

Systems and methods herein describe accessing an image, generating a resized image, generating an image feature vector by applying an image classification neural network to the resized image, generating analysis of the image by processing the image feature vector using a machine-learning classifier trained to analyze the image feature vector, and based on the analysis, determining an event that is attributed to the image.

Nataraj, Lakshmanan↗

Unsupervised learning-enabled pulsed infrared thermographic microscopy of subsurface defects in stainless steel

Metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing method (AM) frequently contain microscopic porosity defects, with typical approximate size distribution from one to 100 microns. Presence of such defects could lead to premature failure of the structure. In principle, structural integrity assessment of LPBF metals can be accomplished with nondestructive evaluation (NDE). Pulsed infrared thermography (PIT) is a non-contact, one-sided NDE method that allows for imaging of internal defects in arbitrary size and shape metallic structures using heat transfer. PIT imaging is performed using compact instrumentation consisting of a flash lamp for deposition of a heat pulse, and a fast frame infrared (IR) camera for measuring surface temperature transients. However, limitations of imaging resolution with PIT include blurring due to heat diffusion, sensitivity limit of the IR camera. We demonstrate enhancement of PIT imaging capability with unsupervised learning (UL), which enables PIT microscopy of subsurface defects in high strength corrosion resistant stainless steel 316 alloy. PIT images were processed with UL spatial–temporal separation-based clustering segmentation (STSCS) algorithm, refined by morphology image processing methods to enhance visibility of defects. The STSCS algorithm starts with wavelet decomposition to spatially de-noise thermograms, followed by UL principal component analysis (PCA), fine-tuning optimization, and neural learning-based independent component analysis (ICA) algorithms to temporally compress de-noised thermograms. The compressed thermograms were further processed with UL-based graph thresholding K-means clustering algorithm for defects segmentation. The STSCS algorithm also includes online learning feature for efficient re-training of the model with new data. For this study, metallic specimens with calibrated microscopic flat bottom hole defects, with diameters in the range from 203 to 76 µm, were produced using electro discharge machining (EDM) drilling. While the raw thermograms do not show any material defects, using STSCS algorithm to process PIT images reveals defects as small as 101 µm in diameter. To the best of our knowledge, this is the smallest reported size of a sub-surface defect in a metal imaged with PIT, which demonstrates the PIT capability of detecting defects in the size range relevant to quality control requirements of LPBF-printed high-strength metals.

36 MATERIALS SCIENCE↗

SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL) tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

The development of a single molecule fluorescence standard and its application in estimating the stoichiometry of the nuclear pore complex

We report here an image-based method to quantify the stoichiometry of diffraction-limited sub-cellular protein complexes in vivo under spinning disk confocal microscopy. A GFP single molecule fluorescence standard was first established by immobilizing His-tagged GFP molecules onto the glass surface via nickel nitrilotriacetic acid functionalized polyethylene glycol. When endogenous nucleoporins were knocked down and replaced by the exogenously expressed and knockdown-resistant GFP-nucleoporins, the stoichiometry of the nucleoporin was estimated by the ratio of its fluorescence intensity to that of the GFP single molecules. Our measured stoichiometry of Nup35, Nup93, Nup133 and Nup88 is 23, 18, 14 and 9 and there are possibly16 copies of Nup107-160 complex per nuclear pore complex. - Highlights: • The method for preparing and imaging a GFP single molecule standard is developed. • The replacement of endogenous nucleoporins with exogenous GFP-tagged ones. • The estimation of the stoichiometry of nucleoporins in the nuclear pore complex.

60 APPLIED LIFE SCIENCES↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality images and improve patient care.

60 APPLIED LIFE SCIENCES↗