Search NASA⌕ Search

SEARCH · Search NASA

Results for “inlet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Comparison of the noise characteristics of two low pressure ratio fans with a high throat Mach number inlet

Acoustics data obtained in experiments with two low pressure ratio 50.8 cm (20 in.) diameter model fans differing in design tip speed were compared. Determination of the average throat Mach number used to compare high Mach inlet noise reduction characteristics was based on a correlation of inlet wall static pressure measurements with a flow field calculation. The largest noise reductions were generally obtained with the higher tip speed fan. At a throat Mach number of 0.79, the difference in noise reduction was about 3.5 db with static test conditions. Although the noise reduction increased for the lower tip speed fan with a simulated flight velocity of 41 m/sec (80 knots), it was still about 2 db less than that of the high tip speed fan which was only tested at the static condition. However, variations in acoustic performance could not be absolutely attributed to the different fan designs because of differences in inlet lip contours which resulted in small variations of peak wall Mach number and axial extend of supersonic and near-sonic flow.

Wesoky, H. L.↗

A small gas inlet system for orbital mass-spectrometer calibrations

A gas inlet system is described for generating precise gas pressures that are to be used as calibration references for the mass spectrometers aboard the dual air density Explorer satellites. This gas inlet system was developed as an inflight calibration technique in which a known amount of onboard gas is released in the satellite cavity and is detected by the mass spectrometer. Although several flight mass spectrometer experiments have been proposed, none make use of the inflight calibration technique described in this report. Laboratory measurements and calibration of the metering leak technique for the gas inlet systems are discussed. The systems tested have metering leak rates between 2 and 4 microliters/sec at 298 K for argon-40, and they produce molecular flow up to 100 torr, which is the highest test pressure in this experiment. Test data show that metering leak rates are reproducible within 1 percent of established means for helium-3, helium-4, and argon-40.

Smith, A.↗

Effect of inlet temperature on the performance of a catalytic reactor

A 12 cm diameter by 15 cm long catalytic reactor was tested with No. 2 diesel fuel in a combustion test rig at inlet temperatures of 700, 800, 900, and 1000 K. Other test conditions included pressures of 3 and 6 x 10 to the 5th power Pa, reference velocities of 10, 15, and 20 m/s, and adiabatic combustion temperatures in the range 1100 to 1400 K. The combustion efficiency was calculated from measurements of carbon monoxide and unburned hydrocarbon emissions. Nitrogen oxide emissions and reactor pressure drop were also measured. At a reference velocity of 10 m/s, the CO and unburned hydrocarbons emissions, and, therefore, the combustion efficiency, were independent of inlet temperature. At an inlet temperature of 1000 K, they were independent of reference velocity. Nitrogen oxides emissions resulted from conversion of the small amount (135 ppm) of fuel-bound nitrogen in the fuel. Up to 90 percent conversion was observed with no apparent effect of any of the test variables. For typical gas turbine operating conditions, all three pollutants were below levels which would permit the most stringent proposed automotive emissions standards to be met.

Anderson, D. N.↗

Effectiveness of an inlet flow turbulence control device to simulate flight fan noise in an anechoic chamber

A hemispherical inlet flow control device was tested on a 50.8 cm. (20-inch) diameter fan stage in the NASA-Lewis Anechoic Chamber. The control device used honeycomb and wire mesh to reduce turbulence intensities entering the fan. Far field acoustic power level results showed about a 5 dB reduction in blade passing tone and about 10 dB reduction in multiple pure tone sound power at 90% design fan speed with the inlet device in place. Hot film cross probes were inserted in the inlet to obtain data for two components of the turbulence at 65 and 90% design fan speed. Without the flow control device the axial intensities were below 1.0%, while the circumferential intensities were almost twice this value. The inflow control device significantly reduced the circumferential turbulence intensities and also reduced the axial length scale.

Woodward, R. P.↗

Estimating maximum instantaneous distortion from inlet total pressure rms measurements

In the present paper, a new mathematical model of inlet turbulence is developed by application of basic fluid dynamics and statistical concepts. The model provides an understanding of the turbulent inlet flow as well as a means of describing the flow in quantitative terms. Specifically, the maximum instantaneous distortion produced by inlet unsteady flow can be estimated by the simple measurement of rms data. Practical application of these techniques leads to a data/acquisition/reduction system that is at least one, and maybe two, orders of magnitude less expensive than conventional methods. Each data point can be reduced in terms of the mean strength of the turbulent vortices. By storing these two parameters (that are representative of the unsteady flow with the steady state information), the maximal instantaneous distortion can be reconstructed for other distortion factors at any time subsequent to the test.

Melick, H. C., Jr.↗

Methods for calculating the transonic boundary layer separation for V/STOL inlets at high incidence angles

A semi-empirical scheme for the prediction of transonic pressure distribution on the surface of V/STOL inlets at high incidence angles has been developed. The investigation is intended to improve the boundary layer calculation and separation prediction by including the effects of shock wave-boundary layer interaction into the Lewis Inlet Viscous Computer Program. Wind-tunnel results and theoretical pressure calculation for critical cases are used in constructing the transonic pressure distribution. The program, which describes the development of the boundary layer and predicts the possible flow separation, can handle the cases of inlets at high incidence angles where local supersonic region may occur in the flow.

Chou, D. C.↗

Basic research in fan source noise: Inlet distortion and turbulence noise

A widely recognized problem in jet engine fan noise is the discrepancy between inflight and static tests. This discrepancy consists of blade passing frequency tones, caused by ingested turbulence that appear in the static tests but not in flight. To reduce the ingested distortions and turbulence in an anechoic chamber, a reverse cone inlet is used to guide the air into the fan. This inlet also has provisions for boundary layer suction and is used in conjunction with a turbulence control structure (TCS) to condition the air impinging on the fan. The program was very successful in reducing the ingested turbulence, to the point where reductions in the acoustic power at blade passing frequency are as high as 18 db for subsonic tip speeds. Even with this large subsonic tone suppression, the supersonic tip speed tonal content remains largely unchanged, indicating that the TCS did not appreciably attenuate the noise but effects the generation via turbulence reduction. Turbulence mapping of the inlet confirmed that the tone reductions are due to a reduction in turbulence, as the low frequency power spectra of the streamwise and transverse turbulence were reduced by up to ten times and 100 times, respectively.

Kantola, R. A.↗

Effect of lip and centerbody geometry on aerodynamic performance of inlets for tilting-nacelle VTOL aircraft

Inlets for tilt-nacelle VTOL aircraft must operate over a wide range of incidence angles and engine weight flows without internal flow separation. Wind tunnel tests of scale model inlets were conducted to evaluate the effectiveness of three geometric variables to provide this capability. Increasing the lip contraction ratio increased the separation angle at all engine weight flows. The optimum axial location of the centerbody occurred when its leading edge was located just downstream of the inlet lip. Compared with a short centerbody, the optimum location of the centerbody resulted in an increase in separation angle at all engine weight flows. Decreasing the lip major-to-minor-axis ratio increased the separation angle at the lower engine weight flows.

Burley, R. R.↗

Performance of a vortex-controlled diffuser in an annular swirl-can combustor at inlet Mach numbers up to 0.53

A short, annular dump diffuser with suction stabilized vortices in the region of abrupt area change was tested with a full scale, annular swirl can combustor. The prediffuser area ratio was 1.4. Performance data were obtained for both isothermal and burning conditions at inlet temperatures of 589 to 895 K and pressures of 0.5 to 1.0 MPa for a range of diffuser inlet Mach numbers from 0.25 to 0.53. Suction rates were 0 to 20 percent of the total diffuser mass flow rate. Diffuser effectiveness increased from 47 percent without suction to approximately 80 percent for a total suction rate of 14 percent. Combustor total pressure loss for the same total suction rate was reduced from 6.8 percent without suction to 4.0 percent at an inlet Mach number of 0.40.

Smith, J. M.↗

Theoretical fan velocity distortions due to inlets and nozzles

Nonuniform velocity profiles imposed on the propulsion system fan can cause fan blade stresses and thrust losses. A theoretical parametric study of the effects of inlets with 0 deg and 90 deg nozzle deflection on the velocity profile at a hypothetical fan is presented. The parameters investigated are fan-to-nozzle spacing and inlet centerline offset. The interaction between the inlet and nozzle is also investigated. The study is made using a two-dimensional analysis.

Hawk, J. D.↗

Effect of steady-state temperature distortion and combined distortion on inlet flow to a turbofan engine

Flow angle, static pressure, total temperature and total pressure were measured in the inlet duct upstream of a turbofan engine operating with temperature distortion or combined pressure-temperature distortion. Such measurements are useful in the evaluation of analytical models of inlet distortion. A rotating gaseous-hydrogen burner and a circumferential 180 degrees-extent screen configuration mounted on a rotatable assembly generated the distortions. Reynolds number index was maintained at 0.5 and engine corrected low-rotor speeds were held at 6000 and 8600 rpm. The measurements showed that at the entrance to the engine, flow angle was largest in the hub region. As flow approached the engine, yaw angle (circumferential variation) increased and pitch angle (radial variation) decreased. The magnitude of static-pressure distortion measured along the inlet-duct and extended bullet nose walls increased exponentially as flow approached the engine.

Soeder, R. H.↗

Effect of inlet temperature on the performance of a catalytic reactor

A 12-cm-diameter by 15-cm-long catalytic reactor was tested with No. 2 diesel fuel in a combustion test rig at inlet temperatures of 700, 800, 900, and 1000 K. Other test conditions included pressures of 300,000 and 600,000 Pa, reference velocities of 10, 15, and 20 m/s, and adiabatic combustion temperatures in the range from 1100 to 1400 K. The combustion efficiency was calculated from measurements of carbon monoxide and unburned hydrocarbon emissions. Nitrogen oxide emissions and reactor pressure drop were also measured. At a reference velocity of 10 m/s, the CO and unburned hydrocarbons emissions and, therefore, the combustion efficiency were independent of inlet temperature. At an inlet temperature of 1000 K, they were independent of reference velocity. Nitrogen oxides emissions resulted from conversion of the small amount of fuel-bound nitrogen in the fuel. Up to 90% conversion was observed with no apparent effect of any of the test variables. For typical gas-turbine operating conditions, all three pollutants were below levels which would permit the most stringent proposed automotive emissions standards to be met.

Anderson, D. N.↗

Effect of lip and centerbody geometry on aerodynamic performance of inlets for tilting-nacelle VTOL aircraft

Inlets for tilt-nacelle VTOL aircraft must operate over a wide range of incidence angles and engine weight flows without internal flow separation. Wind tunnel tests of scale model inlets were conducted to evaluate the effectiveness of three geometric variables to provide this capability. Increasing the lip contraction ratio increased the separation angle at all engine weight flows. The optimum axial location of the centerbody occurred when its leading edge was located just downstream of the inlet lip. Compared with a short centerbody, the optimum location of the centerbody resulted in an increase in separation angle at all engine weight flows. Decreasing the lip major-to-minor-axis ratio increased the separation angle at the lower engine weight flows.

Burley, R. R.↗

Theoretical fan velocity distortions due to inlets and nozzles

Nonuniform velocity profiles imposed on the propulsion system fan can cause fan blade stresses and thrust losses. This paper presents a theoretical parametric study of the effects of inlets with 0 deg and 90 deg nozzle deflection on the velocity profile at a hypothetical fan. The parameters investigated are fan-to-nozzle spacing and inlet centerline offset. The interaction between the inlet and nozzle is also investigated. The study is made using a two-dimensional analysis

Hawk, J. D.↗

Recent applications of theoretical analysis to V/STOL inlet design

A brief description of the axisymmetric potential flow and boundary layer analysis methods used at the NASA Lewis Research Center, is presented. Application of this method to inlet problems arising from both tilt-nacelle and fixed-nacelle V/STOL aircraft configurations is illustrated. A three-dimensional inlet analysis computer program is described and the preliminary results presented. Finally, a suggested approach to optimum design of inlets for high angle-of-attack operation is discussed.

Stockman, N. O.↗

Flow field in supersonic mixed-compression inlets

Program uses method of characteristics for steady three-dimensional flow to calculate flow field in supersonic portion of mixed-compression aircraft inlet at non-zero angle of attack. Results agree well with experimental data except in regions of high viscous interaction. Flow field for variety of mixed-compression inlets can be calculated. Input includes geometry and attack of inlet. Output consists of list of parameters, solution planes, and description of shock waves. Program is written in FORTRAN IV for batch execution on CDC 6000-series.

Bishop, A. R.↗

Calculation of two-dimensional inlet flow fields in a supersonic free stream: Program documentation and test cases

The use of a computer code for the calculation of two dimensional inlet flow fields in a supersonic free stream and a nonorthogonal mesh-generation code are illustrated by specific examples. Input, output, and program operation and use are given and explained for the case of supercritical inlet operation at a subdesign Mach number (M Mach free stream = 2.09) for an isentropic-compression, drooped-cowl inlet. Source listings of the computer codes are also provided.

Biringen, S. H.↗

A two-dimensional potential flow model for ground-induced effects on jet and fan inlets

A free-streamline potential flow model is developed for the flowfield external to a stationary jet or fan inlet in proximity to a ground plane. It is assumed that the flow is steady, incompressible, and irrotational. A two-dimensional flat plate geometry models the inlet configuration, and free streamline theory is used to avoid unrealistic infinite flow velocities at the lips of the inlet, and to account somewhat for flow separation. A water table experiment is used to verify the analytical results. The fact that the solutions are found to be limited to only a certain range of diameter-height ratios implies an overdetermination of the problem by free streamline theory. Also studied are the convective properties of small vortical disturbances superimposed on the ideal flow solution.

Newman, W. H.↗