Search NASA⌕ Search

SEARCH · Search NASA

Results for “interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Interference effects of thrust reversing on horizontal tail effectiveness of twin-engine fighter aircraft at Mach numbers from 0.15 to 0.90

An investigation was conducted in the Langley 16 foot Transonic Tunnel to determine the interference effects of thrust reversing on horizontal tail effectiveness of a twin engine, general research fighter model at approach and in-flight speeds. Twin vertical tails at three longitudinal locations were tested at a cant angle of 0 deg. One configuration was also tested at a cant angle of 20 deg. Two nonaxisymmetric nozzle reverser concepts were studied. Test data were obtained at Mach numbers of 0.15, 0.60, and 0.90 and at angles of attack from -3 to 9 deg. Nozzle pressure ratios varied from jet off to 7.0, depending upon Mach number. At landing approach speed (Mach number 0.15), thrust reverser operation usually resulted in large variations (up to 70% increase) in horizontal tail effectiveness as nozzle pressure ratio was varied at zero angle of attack or as angle of attack was varied at constant nozzle pressure ratio. There was always a decrease in effectiveness at Mach numbers of 0.60 and 0.90 as a result of reverser operation.

Capone, F. J.↗

Automatic processing system for shadowgraph and interference patterns

The design and operation of an automatic system for the processing of shadowgraph and interference images are described. The system includes a two-coordinate processing table with an optical system for the projection of transparent images onto the photodetector, an image filter in the photodetector field, and a device for controlling the movement of the table and transmitting information to the minicomputer.

Vereninov, I. A.↗

Transonic interference reduction by limited ventilation wall panels

In two wind tunnels used for the two-dimensional airfoil tests, each wall above and below the model was modified by replacing small segments of the solid boundaries with perforated plates vented into sealed chambers. Perforated segments having approximately 40 percent open area were found to reduce the transonic wall interference to a negligible level, for a model chord-to-tunnel height ratio of 0.5. This report describes the physical arrangement and presents typical model pressure distributions to illustrate the effectiveness of the technique.

Lee, John D.↗

Characteristics of electromagnetic interference generated by arc discharges

Electromagnetic interference (EMI) signatures resulting from arc discharges are characterized, and the effects of electrostatic discharges (ESDs) on the design of spacecraft systems are investigated. EMI characterization experiments were performed on Mylar, Teflon, Kapton, fused silica, and fiberglass in a vacuum chamber with acrylic walls; the experimental design and procedures are described. Discharge current pulses and RF spectra generated by the sample materials are examined. The relation between the magnitude of EMI generated during an ESD event and the material, environment, and geometry is studied. The solar-array/plasma interaction is analyzed; particular attention is given to the rate of discharge as a function of plasma density. The physical mechanisms of ESD-generated EMI are discussed. The data reveal that ESD parameters are dependent on the test environment.

Leung, Philip↗

Avionics electromagnetic interference immunity and environment

Aircraft electromagnetic spectrum and radio frequency (RF) field strengths are charted, profiling the higher levels of electromagnetic voltages encountered by the commercial aircraft wiring. Selected military, urban, and rural electromagnetic field levels are plotted and provide a comparison of radiation amplitudes. Low frequency magnetic fields and electric fields from 400 H(Z) power systems are charted versus frequency and wire separation to indicate induced voltages on adjacent or neighboring circuits. Induced EMI levels and attenuation characteristics of electric, magnetic, RF fields, and transients are plotted and graphed for common types of wire circuits. The significance of wire circuit returns and shielding is emphasized to highlight the techniques that help block the paths of electromagnetic interference and maintain avionic interface signal quality.

Clarke, C. A.↗

Application of a panel code to unsteady wing-propeller interference

Attention is given to the predictions of unsteady, incompressible, potential flow, on the basis of an extension of Maskew's (1982) low-order paneling method. This approach, which is a nonlinear one in that the small-perturbation approximation is not made, is able to arrive at solutions for such general problems as that of the interference between a two-bladed propeller and a wing. Due to the geometry and flow field in question, a wake-snipping procedure is introduced.

Rangwalla, A. A.↗

Canceling Electromagnetic Interference During Tests

Old technique solves modern problem. Simple amplitude-and-phase-cancellation technique removes strong electromagnetic interference from received test signal, enabling recovery of relatively weak signal from device under test. Useful in outdoor tests of devices for electromagnetic compatibility.

Robinson, Paul A., Jr.↗

Evaluation of a flexible wall testing technique to minimize wall interferences in the NASA Langley 0.3-m Transonic Cryogenic Tunnel

Free air simulations in conventional transonic wind tunnels require improvement which adaptive wall testing techniques can provide primarily by minimizing wall interferences. In addition, these techniques offer other substantial advantages such as increased Reynolds number capability and a reduction in tunnel drive power. The combination of an adaptive wall test section with a continuous flow cryogenic wind tunnel is unique. The test section has four solid walls with two flexible walls mounted between rigid sidewalls. This modification of an existing major facility stresses the practicalities of the testing technique. These practicalities were evaluated in terms of flexible wall test section design and operation. Increased hardware and operating complexity of the new test section is offset by a significant improvement in real-time data accuracy in two-dimensional testing. Validation testing has expanded the experience with flexible walled test sections into the realms of flight Reynolds numbers and high lift. Data accuracy has been assessed with regard to test section geometry and operating tolerances. The successful evaluation of the testing technique in two-dimensional testing has proved that a production type operation is possible, with suitable control system and test section design. The 0.3-m Transonic Cryogenic Tunnel with an adaptive wall test section currently represents the most advanced two-dimensional facility anywhere.

Wolf, Stephen W. D.↗

A procedure based on the Euler equations for correcting transonic wind tunnel wall interference

Based on an optimization formulation, a procedure has been developed to evaluate Mach number and angle-of-attack corrections. The Euler equations are assumed to be the flow governing equations. To obtain efficient solutions for the optimization problem, the iterative solutions for the flow variables and the design parameters are simultaneously updated. In addition to the model lift and geometry, the procedure requires pressure measurements near the tunnel walls. The accuracy and efficiency of several optimization techniques are investigated. The effect of perturbing certain test conditions on the residual interference is investigated.

Rizk, Magdi H.↗

A new class of stratospheric vacillations in a highly truncated model due to wave interference

A new class of vacillations is obtained in the Holton and Mass model with a different bottom boundary condition. The model is a highly truncated spectral model describing wave-zonal flow interactions in a forced-dissipative system. The mean zonal wind and the wave change their vertical structures periodically with a period of the wave progression (5-10 days for the parameters used in this study). The vacillations are interpreted as an interference between a stationary wave and a topographically modified Rossby wave. The modified Rossby wave is an eigenmode of baroclinic flow in the presence of bottom topography within the framework of the highly truncated system. Time variations of the mean zonal wind are essential for the modification of the Rossby wave.

Yoden, Shigeo↗

Cross-modal interference and task integration - Resources or preemption switching?

Data are reviewed from experiments that have contrasted intra-modal (visual-visual) information presentation with cross-modal (visual-auditory) presentation. Five different processing mechanisms that are operating in dual stimulus tasks are described, and it is concluded that in studies where visual scanning is not required, cross-modal effects are of two classes. When the visual task is continuous (tracking), a discrete auditory stimulus will preempt tracking performance relative to a discrete visual stimulus, leading to an effective shift in allocation bias. When both tasks are discrete, the data regarding the relative advantages of cross- vs. intra-modal interference are ambivalent.

Wickens, Christopher D.↗

A panel method procedure for interference assessment in slotted-wall wind tunnels

This paper describes a method for three-dimensional wind tunnel interference assessment developed specifically for slotted-wall tunnels. The method is an adaptation to the assessment problem of a previously published high-order panel method procedure for simulating the flow in slotted-wall tunnel test sections. The method uses a mixed outer boundary condition, primarily a Neumann condition, with measured pressure constraints used to control only those boundary phenomena which can not be specified accurately a priori. Assessment results are illustrated from a calibration test with variations in wall geometry, and from tests of a generic subsonic transport aircraft configuration.

Kemp, William B., Jr.↗

A transonic wind tunnel wall interference prediction code

A small disturbance transonic wall interference prediction code has been developed that is capable of modeling solid, open, perforated, and slotted walls as well as slotted and solid walls with viscous effects. This code was developed by modifying the outer boundary conditions of an existing aerodynamic wing-body-pod-pylon-winglet analysis code. The boundary conditions are presented in the form of equations which simulate the flow at the wall, as well as finite difference approximations to the equations. Comparisons are presented at transonic flow conditions between computational results and experimental data for a wing alone in a solid wall wind tunnel and wing-body configurations in both slotted and solid wind tunnels.

Phillips, Pamela S.↗

Adaptive wall technology for minimization of wall interferences in transonic wind tunnels

Modern experimental techniques to improve free air simulations in transonic wind tunnels by use of adaptive wall technology are reviewed. Considered are the significant advantages of adaptive wall testing techniques with respect to wall interferences, Reynolds number, tunnel drive power, and flow quality. The application of these testing techniques relies on making the test section boundaries adjustable and using a rapid wall adjustment procedure. A historical overview shows how the disjointed development of these testing techniques, since 1938, is closely linked to available computer support. An overview of Adaptive Wall Test Section (AWTS) designs shows a preference for use of relatively simple designs with solid adaptive walls in 2- and 3-D testing. Operational aspects of AWTS's are discussed with regard to production type operation where adaptive wall adjustments need to be quick. Both 2- and 3-D data are presented to illustrate the quality of AWTS data over the transonic speed range. Adaptive wall technology is available for general use in 2-D testing, even in cryogenic wind tunnels. In 3-D testing, more refinement of the adaptive wall testing techniques is required before more widespread use can be planned.

Wolf, Stephen W. D.↗

Interference effects on the hypersonic, rarefied flow about a flat plate

The Direct Simulation Monte Carlo method is used to study the hypersonic, rarified flow interference effects on a flat plate caused by nearby surfaces. Calculations focus on shock-boundary-layer and shock-lip interactions in hypersonic inlets. Results are presented for geometries consisting of a flat plate with different leading-edge shapes over a flat lower wall and a blunt-edge flat plate over a 5-degree wedge. The problems simulated correspond to a typical entry flight condition of 7.5 km/s at altitudes of 75 to 90 km. The results show increases in predicted local heating rates for shock-boundary-layer and shock-lip interactions that are quantitatively similar to those observed experimentally at much higher densities.

Wilmoth, Richard G.↗

Radio frequency interference survey over the 1.0-10.4 GHz frequency range at the Goldstone-Venus Development Station

The results of a low sensitivity Radio Frequency Interference (RFI) survey carried out at the Venus Station of the Goldstone Communications Complex are reported. The data cover the spectral range from 1 GHz to 10.4 GHz with a 10-kHz instantaneous bandwidth. Frequency and power levels were observed using a sweep-frequency spectrum analyzer connected to a 1-m diameter antenna pointed at zenith. The survey was conducted from February 16, 1987 through February 24, 1987.

Gulkis, S.↗

Wall interference assessment and corrections

Wind tunnel wall interference assessment and correction (WIAC) concepts, applications, and typical results are discussed in terms of several nonlinear transonic codes and one panel method code developed for and being implemented at NASA-Langley. Contrasts between 2-D and 3-D transonic testing factors which affect WIAC procedures are illustrated using airfoil data from the 0.3 m Transonic Cryogenic Tunnel and Pathfinder 1 data from the National Transonic Facility. Initial results from the 3-D WIAC codes are encouraging; research on and implementation of WIAC concepts continue.

Newman, P. A.↗