Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Sharp Drop in the Mobility of Holes with a Decrease in Their Two-Dimensional Concentration by an External Voltage in Boron δ-Doped Diamond Layers

It is shown, both analytically and numerically, that the hole mobility in boron δ-doped (i.e., with a thickness on the order of several lattice constants) diamond layers drops with a decrease in their two-dimensional concentration during depletion of the δ-doped layer by an external voltage. This drop is most pronounced for the maximum initial two-dimensional hole concentrations ~ 3 × 10{sup 13} cm{sup –2} (limited from above by the condition for the possibility of their significant reduction without the electrical breakdown of diamond). This is explained by a decrease in the degree of screening of scattering Coulomb potentials of ionized boron atoms and an increase in the scattering efficiency of degenerate holes from these atoms due to a drop in the kinetic energy of holes. The corresponding calculations of the transport scattering cross section of holes are performed beyond the Born approximation (i.e., perturbation theory), which is inapplicable for boron δ-doped diamond layers. The predicted effect can be used to increase the efficiency of source-to-drain current modulation by a gate voltage in diamond field-effect transistors (FETs) with δ-doped conduction channels.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-478: Effect of Deconvolution in Analysis of Mega Voltage Photon Beam Profiles

Purpose: To study and compare the penumbra of 6 MV and 15 MV photon beam profiles after deconvoluting different volume ionization chambers. Methods: 0.125cc Semi-Flex chamber, Markus Chamber and PTW Farmer chamber were used to measure the in-plane and cross-plane profiles at 5 cm depth for 6 MV and 15 MV photons. The profiles were measured for various field sizes starting from 2×2 cm till 30×30 cm. PTW TBA scan software was used for the measurements and the “deconvolution” functionality in the software was used to remove the volume averaging effect due to finite volume of the chamber along lateral and longitudinal directions for all the ionization chambers. The predicted true profile was compared and the change in penumbra before and after deconvolution was studied. Results: After deconvoluting the penumbra decreased by 1 mm for field sizes ranging from 2 × 2 cm till 20 x20 cm. This is observed for along both lateral and longitudinal directions. However for field sizes from 20 × 20 till 30 ×30 cm the difference in penumbra was around 1.2 till 1.8 mm. This was observed for both 6 MV and 15 MV photon beams. The penumbra was always lesser in the deconvoluted profiles for all the ionization chambers involved in the study. The variation in difference in penumbral values were in the order of 0.1 till 0.3 mm between the deconvoluted profile along lateral and longitudinal directions for all the chambers under study. Deconvolution of the profiles along longitudinal direction for Farmer chamber was not good and is not comparable with other deconvoluted profiles. Conclusion: The results of the deconvoluted profiles for 0.125cc and Markus chamber was comparable and the deconvolution functionality can be used to overcome the volume averaging effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metronomic Small Molecule Inhibitor of Bcl-2 (TW-37) Is Antiangiogenic and Potentiates the Antitumor Effect of Ionizing Radiation

Purpose: To investigate the effect of a metronomic (low-dose, high-frequency) small-molecule inhibitor of Bcl-2 (TW-37) in combination with radiotherapy on microvascular endothelial cells in vitro and in tumor angiogenesis in vivo. Methods and Materials: Primary human dermal microvascular endothelial cells were exposed to ionizing radiation and/or TW-37 and colony formation, as well as capillary sprouting in three-dimensional collagen matrices, was evaluated. Xenografts vascularized with human blood vessels were engineered by cotransplantation of human squamous cell carcinoma cells (OSCC3) and human dermal microvascular endothelial cells seeded in highly porous biodegradable scaffolds into the subcutaneous space of immunodeficient mice. Mice were treated with metronomic TW-37 and/or radiation, and tumor growth was evaluated. Results: Low-dose TW-37 sensitized primary endothelial cells to radiation-induced inhibition of colony formation. Low-dose TW-37 or radiation partially inhibited endothelial cell sprout formation, and in combination, these therapies abrogated new sprouting. Combination of metronomic TW-37 and low-dose radiation inhibited tumor growth and resulted in significant increase in time to failure compared with controls, whereas single agents did not. Notably, histopathologic analysis revealed that tumors treated with TW-37 (with or without radiation) are more differentiated and showed more cohesive invasive fronts, which is consistent with less aggressive phenotype. Conclusions: These results demonstrate that metronomic TW-37 potentiates the antitumor effects of radiotherapy and suggest that patients with head and neck cancer might benefit from the combination of small molecule inhibitor of Bcl-2 and radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of laser-pulse-field harmonics in a gas upon impact ionisation of atoms

The generation of harmonics of a high-power-laser-pulse field in a gas during impact ionisation of atoms by oscillating electrons is studied theoretically. Fields are considered under conditions when the oscillation energy of electrons in the radiation field, remaining nonrelativistic, considerably exceeds the ionisation potential of an atom. In addition, the radiation field was assumed weak compared to the atomic field (E{sub a} = 5.1x10{sup 9} V cm{sup -1}), which allowed us to neglect the field ionisation of atoms, taking into account only the impact ionisation of atoms by oscillating electrons. Under such conditions, along with the elastic scattering of electrons, the inelastic scattering of oscillating electrons accompanied by ionisation of gas atoms can make a significant contribution to a nonlinear current induced in the plasma. (special issue devoted to the 25th anniversary of the a.m. prokhorov general physics institute)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guided ion beam and theoretical studies of the reaction of Ag{sup +} with CS{sub 2}: Gas-phase thermochemistry of AgS{sup +} and AgCS{sup +} and insight into spin-forbidden reactions

The gas-phase reactivity of the atomic transition metal cation, Ag{sup +}, with CS{sub 2} is investigated using guided-ion beam mass spectrometry. Endothermic reactions forming AgS{sup +} and AgCS{sup +} are observed but are quite inefficient. This observation is largely attributed to the stability of the closed shell Ag{sup +}({sup 1}S,4d{sup 10}) ground state, but is also influenced by the fact that the reactions producing ground state AgS{sup +} and AgCS{sup +} products are both spin forbidden. Analysis of the kinetic energy dependence of the cross sections for formation of these two products yields the 0 K bond energies of D{sub 0}(Ag{sup +}-S)=1.40{+-}0.12 eV and D{sub 0}(Ag{sup +}-CS)=1.98{+-}0.14 eV. Quantum chemical calculations are used to investigate the electronic structure of the two product ions as well as the potential energy surfaces for reaction. The primary mechanism involves oxidative addition of a CS bond to the metal cation followed by simple Ag-S or Ag-CS bond cleavage. Crossing points between the singlet and triplet surfaces are located near the transition states for bond activation. Comparison with analogous work on other late second-row transition metal cations indicates that the location of the crossing points bears directly on the efficiency of these spin-forbidden processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of a wire scanner for monitoring residual gas ionization in Soreq Applied Research Accelerator Facility 20 keV/u proton/deuteron low energy beam transport beam line

The ion source end of the Soreq Applied Research Accelerator Facility accelerator consists of a proton/deuteron ECR ion source and a low energy beam transport (LEBT) beam line. An observed reduction of the radio frequency quadrupole transmission with increase of the LEBT current prompted additional study of the LEBT beam properties. Numerous measurements have been made with the LEBT bream profiler wire biased by a variable voltage. Current-voltage characteristics in presence of the proton beam were measured even when the wire was far out of the beam. The current-voltage characteristic in this case strongly resembles an asymmetric diodelike characteristic, which is typical of Langmuir probes monitoring plasma. The measurement of biased wire currents, outside the beam, enables us to estimate the effective charge density in vacuum.

43 PARTICLE ACCELERATORS↗

Texas Spectroscopic Search for Lyα Emission at the End of Reionization. III. The Lyα Equivalent-width Distribution and Ionized Structures at z > 7

Lyα emission from galaxies can be utilized to characterize the ionization state in the intergalactic medium (IGM). We report our search for Lyα emission at z > 7 using a comprehensive Keck/MOSFIRE near-infrared spectroscopic data set, as part of the Texas Spectroscopic Search for Lyα Emission at the End of Reionization Survey. We analyze data from 10 nights of MOSFIRE observations which together target 72 high-z candidate galaxies in the GOODS-N field, all with deep exposure times of 4.5–19 hr. Utilizing an improved automated emission-line search, we report 10 Lyα emission lines detected (>4σ) at z > 7, significantly increasing the spectroscopically confirmed sample. Our sample includes large equivalent-width (EW) Lyα emitters (>50 Å), and additional tentative Lyα emission lines detected at 3σ–4σ from five additional galaxies. We constrain the Lyα EW distribution at z ~ 7.6, finding a significant drop from z ≲ 6, suggesting an increasing fraction of neutral hydrogen (H I) in the IGM in this epoch. We estimate the Lyα transmission through the IGM (=EW(z)~7.6/EW(z~2–6)) and infer an IGM H I fraction (X(HI)) of 49 (+19,-19)% at z ~ 7.6, which is lower in modest tension (>1σ) with recent measurements at z ~ 7.6. The spatial distribution of the detected Lyα emitters implies the presence of a potential highly ionized region at z ~ 7.55, which hosts four Lyα emitters within a ∼40 cMpc spatial separation. The prominence of this ionized region in our data set could explain our lower inferred value of X(HI), though our analysis is also sensitive to the chosen reference Lyα EW distribution values and reionization models.

Intae Jung↗

Anomalous laser-induced ionization rates of molecules and rare-gas atoms

Electron tunnel ionization is considered as the mechanism for producing free electrons in gases under laser radiation. The Keldysh result and the Ammosov-Delone-Krainov (ADK) formulation are amended by considering the excess forces due to the interaction of the electric field of the laser with the electron cloud in a simple mass-on-a-spring approximation. The result of this excess force is a kinetic energy that is directed along the polarization vector of the laser field and an induced potential energy that are proposed as a determining factor in electron tunnel ionization. Relative ionization rates for various pairs of gases are calculated and compared with reported figures. Comparisons were made between several combinations of O{sub 2}, Xe, Ar, N{sub 2}, Cl{sub 2}, H{sub 2}, CO, Kr, NO, F{sub 2}, and D{sub 2}. Predicted ratios of ionization rates between pairs of gases are compared to ADK predictions. Apparently anomalous ionization rates of O{sub 2}, D{sub 2}, and H{sub 2} are explained. A simple expression is developed that reveals why the ionization rate of Xe is about an order of magnitude larger than that of O{sub 2} even though their ionization potentials are nearly identical; why CO is only about half that of Kr even though their ionization potentials are nearly the same; why the ratio of O{sub 2} to O is about ten times larger than predicted by ADK; and why the ratio of NO to Xe is about an order of magnitude less than predicted by ADK.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-G-TeP2-03: Comparison of Standard Dosimetry Protocol in Japan and AAPM TG-51 Addendum in Order to Establish Optimal Dosimetry for FFF Beam

Purpose: Japan Standard Dosimetry of Absorbed dose to water in external beam radiotherapy (JSDP12) is widely used to measure radiation dose in radiotherapy. However, JSDP12 does not take flattening-filter-free (FFF) beam into consideration. In addition, JSDP12 applied TPR20,10 for dose quality index for photon beam. The purpose of this study is to compare JSDP12 with AAPM TG-51 addendum in order to establish optimal dosimetry procedure for FFF beam. Method: We evaluated the ion-recombination factor (ks) and the correction factor of radial beam profile (Prp) in FFF beam dosimetry. The ks was introduced by 2 voltages method and verified by Jaffe’s plot. The Prp was given by both film measurement and calculation of treatment planning system, and compared them. Next, we compared the dose quality indexes (kQ) between TPR20,10 method and PDD(10)x method. Finally we considered optimal dosimetry protocol for FFF photon beam using JSDP12 with referring TG-51 addendum protocols. The FFF photon beams of 6 MV (6X-FFF) and 10 MV (10X-FFF) from TrueBeam were investigated in this study. Results: The ks for 6X-FFF and 10X-FFF beams were 1.005 and 1.010, respectively. The Prp of 0.6 cc ionization chamber for 6X-FFF and 10X-FFF beams (Film, TPS) were (1.004, 1.008) and (1.005, 1.008), respectively. The kQ for 6X-FFF and 10X-FFF beams (JSDP12, TG-51 addendum) were (0.9950, 0.9947) and (0.9851, 0.9845), respectively. The most effective factor for uncertainty in FFF photon beam measurement was Prp for JSDP12 formalism. Total dosimetric differences between JSDP12 and TG-51 addendum for 6X-FFF and 10X-FFF were -0.47% and -0.73%, respectively. Conclusion: The total dosimetric difference between JSDP12 and TG-51 addendum was within 1%. The introduction of kQ given by JSDP is feasible for FFF photon beam dosimetry. However, we think Prp should be considered for optimal dosimetry procedure even if JSDP12 is used for FFF photon beam dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-289: MLC Fluence Sonogram Based Delivery Quality Assurance for Bilateral Breast Irradiation

Purpose: Performing DQA for Bilateral (B-L) breast tomotherapy is a challenging task due to the limitation of any commercially available detector array or film. Aim of this study is to perform DQA for B-L breast tomotherapy plan using MLC fluence sinogram. Methods: Treatment plan was generated on Tomotherapy system for B-L breast tumour. B-L breast targets were given 50.4 Gy prescribed over 28 fractions. Plan is generated with 6 MV photon beam & pitch was set to 0.3. As the width of the total target is 39 cm (left & right) length is 20 cm. DQA plan delivered without any phantom on the mega voltage computed tomography (MCVT) detector system. The pulses recorded by MVCT system were exported to the delivery analysis software (Tomotherapy Inc.) for reconstruction. The detector signals are reconstructed to a sonogram and converted to MLC fluence sonogram. The MLC fluence sinogram compared with the planned fluence sinogram. Also point dose measured with cheese phantom and ionization chamber to verify the absolute dose component Results: Planned fluence sinogram and reconstructed MLC fluence sinogram were compared using Gamma metric. MLC positional difference and intensity of the beamlet were used as parameters to evaluate gamma. 3 mm positional difference and 3% beamlet intensity difference were used set for gamma calculation. A total of 26784 non-zero beamlets were included in the analysis out of which 161 beamlets had gamma more than 1. The gamma passing rate found to be 99.4%. Point dose measurements were within 1.3% of the calculated dose. Conclusion: MLC fluence sinogram based delivery quality assurance performed for bilateral breast irradiation. This would be a suitable alternate for large volume targets like bilateral breast, Total body irradiation etc. However conventional method of DQA should be used to validate this method periodically.

60 APPLIED LIFE SCIENCES↗

Guided ion beam and theoretical study of the reactions of Au{sup +} with H{sub 2}, D{sub 2}, and HD

Reactions of the late third-row transition metal cation Au{sup +} with H{sub 2}, D{sub 2}, and HD are examined using guided ion beam tandem mass spectrometry. A flow tube ion source produces Au{sup +} in its {sup 1}S (5d{sup 10}) electronic ground state level. Corresponding state-specific reaction cross sections for forming AuH{sup +} and AuD{sup +} as a function of kinetic energy are obtained and analyzed to give a 0 K bond dissociation energy of D{sub 0}(Au{sup +}-H) = 2.13 {+-} 0.11 eV. Quantum chemical calculations at the B3LYP/HW+/6-311+G(3p) and B3LYP/Def2TZVPP levels performed here show good agreement with the experimental bond energy. Theory also provides the electronic structures of these species and the reactive potential energy surfaces. We also compare this third-row transition metal system with previous results for analogous reactions of the first-row and second-row congeners, Cu{sup +} and Ag{sup +}. We find that Au{sup +} has a stronger M{sup +}-H bond, which can be explained by the lanthanide contraction and relativistic effects that alter the relative size of the valence s and d orbitals. Results from reactions with HD provide insight into the reaction mechanism and indicate that ground state Au{sup +} reacts largely via a direct mechanism, in concordance with the behavior of the lighter group 11 metal ions, but includes more statistical behavior than these metals as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental analysis of a novel and low-cost pin photodiode dosimetry system for diagnostic radiology

Silicon PIN photodiode has recently found broad and exciting applications in the ionizing radiation dosimetry. In this study a compact and novel dosimetry system using a commercially available PIN photodiode (BPW34) has been experimentally tested for diagnostic radiology. The system was evaluated with clinical beams routinely used for diagnostic radiology and calibrated using a secondary reference standard. Measured dose with PIN photodiode (Air Kerma) varied from 10 to 430 μGy for tube voltages from 40 to 100 kVp and tube current from 0.4 to 40 mAs. The minimum detectable organ dose was estimated to be 10 μGy with 20% uncertainty. Results showed a linear correlation between the PIN photodiode readout and dose measured with standard dosimeters spanning doses received. The present dosimetry system having advantages of suitable sensitivity with immediate readout of dose values, low cost, and portability could be used as an alternative to passive dosimetry system such as thermoluminescent dosimeter for dose measurements in diagnostic radiology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics-Based Spectra of Accretion Disks around Black Holes

The purpose of this grant was to begin the process of deriving the light output of accretion disks around black holes directly from the actual processes that inject heat into the accreting matter, rather than from guessed dependences of heating rate on physical parameters. At JHU, the effort has focussed so far on models of accretion onto "intermediate mass black holes", a possible class of black holes, examples of which may have recently been discovered in nearby galaxies. There, Krolik and his student (Yawei Hui) have computed stellar atmospheres for uniformly-heated disks around this class of black holes. Their models serve two purposes: they are the very first serious attempts to compute the spectrum from accreting black holes in this mass range; and a library of such models can be used later in this program as contrasts for those computed on the basis of real disk dynamics. The output from these local disk calculations has also been successfully coupled to a program that applies the appropriate relativistic transformations and computes photon trajectories in order to predict the spectrum received by observers located at different polar angles. The principal new result of these calculations is the discovery of potentially observable ionization edges of H-like C and O at frequencies near the peak in flux from these objects. Most of the grant money at UCSB was spent on supporting graduate student Shane Davis. In addition. some money was spent on supporting two other students: Ari Socrates (now a Hubble Fellow at Princeton), and Laura Melling. Davis spent the year constructing stellar atmosphere models of accretion disks appropriate for the high/soft (thermal) state of black hole X-ray binaries. As with AGN models published previously by our collaboration with NASA support. our models include a complete general relativistic treatment of both the disk structure and the propagation of photons from the disk to a distant observer. They also include all important continuum opacity sources, including Compton scattering and bound-free opacity from abundant metal species. The principal new result is that bound-free opacity is very significant in altering the continuum spectral shape, resulting for example in quite different "color correction factors" compared to those predicted previously. In addition, the models predict a relationship between luminosity and inner disk temperature that is, for the first time, in accord with that observed. The primary purpose of the grant was to incorporate more realistic accretion disk physics, learned largely from simulations, into such spectral models. The Davis et al. paper includes consideration of a vertical dissipation profile computed from radiation magneto-hydrodynamic simulations of MRI turbulence by N. J. Turner (2004). So long as the disk is effectively thick, such dissipation profiles do not affect the predicted spectrum significantly. (More work needs to be done on these simulations, however.) A potentially more serious issue is that MRI turbulence produces substantial inhomogeneities, as do photon bubble instabilities. These inhomogeneities can affect the spectra by enhancing the effects of absorption opacity over scattering opacity. We have done some preliminary Monte Carlo calculations to explore these effects.

Krolik, Julian H.↗

Response to high-energy photons of PTW31014 PinPoint ion chamber with a central aluminum electrode

Since its introduction the PinPoint (PTW-Freiburg) micro-ionization chamber has been proposed for relative dosimetry (output factors, depth dose curves, and beam profiles) as well as for determination of absolute dose of small high-energy photon beams. This paper investigates the dosimetric performance of a new design (type 31014) of the PinPoint ion chamber with a central aluminum electrode. The study included characterization of inherent and radiation-induced leakage, ion collection efficiency and polarity effect, relative response of the chamber, measurement of beam profiles, and depth dose curves. The 6 and 15 MV photon beams of a Varian 2100 C/D were considered. At the nominal operating voltage of 400 V the PinPoint type 31014 chamber was found to present a strong field size dependence of the polarity correction factor and an excess of the collected charge, which can lead to an underestimation of the collection efficiency if determined with the conventional ''two-voltage'' method. In comparison to the original PinPoint design (type 31006) the authors found for type 31014 chamber no overresponse to large-area fields if polarity correction is applied. If no correction is taken into consideration, the authors found the chamber's output to be inaccurate for large-area fields (0.5% accuracy limited up to the 12x12 and 20x20 cm{sup 2} field for the 6 and 15 MV beams, respectively), which is a direct consequence of the stem and polarity effects due to the chamber's very small sensitive volume (0.015 cc) and cable irradiation. Beam profiles and depth dose curves measured with type 31014 PinPoint chamber for small and medium size fields were compared to data measured with a 0.125 cc ion chamber and with high-resolution Kodak EDR2 films. Analysis of the penumbra (80%-20% distance) showed that the spatial resolution of type 31014 PinPoint ion chamber approaches (penumbra broadening {<=}0.6 mm) EDR2 film results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Density-Functional Tight-Binding Methods for Simulation of Protic Molecular Ion Pairs

In this work, we benchmark the accuracy of the density-functional tight-binding (DFTB) method, namely the long-range corrected second-order (LC-DFTB2) and third-order (DFTB3) models, for predicting energetics of imidazolium-based ionic liquid (IL) ion pairs. We compare the DFTB models against popular density functionals such as LC-ωPBE and B3LYP, using ab initio domain-based local pair-natural orbital coupled cluster (DLPNO-CC) energies as reference. Calculations were carried out in the gas phase, as well as in aqueous solution using implicit solvent methods. We find that the LC-DFTB2 model shows excellent performance in the gas phase and agrees well with reference energies in implicit solvent, often outperforming DFTB3 predictions for complexation energetics. Our study identifies a range of opportunities for use of the LC-DFTB method and quantifies its sensitivity to protonation states and the types of chemical interactions between ion pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Near-threshold absolute photoionization cross-sections of some reaction intermediates in combustion

The use of photoionization mass spectrometry for the development of quantitative kinetic models for the complex combustion chemistry of both conventional hydrocarbon fuels and oxygenated biofuels requires near-threshold measurements of absolute photoionization cross-sections for numerous reaction intermediates. Near-threshold absolute cross-sections for molecular and dissociative photoionization for 20 stable reaction intermediates (methane, ethane, propane, n-butane, cyclopropane, methylcyclopentane, 1-butene, cis-2-butene, isobutene, 1-pentene, cyclohexene. 33 -dimethyl-1-butene, 1,3-hexadiene, 1,3-cyclohexadiene, methyl acetate, ethyl acetate, tetrahydrofuran, propanal, 1-butyne, 2-butyne) are presented. Previously measured total photoionization cross-sections for 9 of these molecules are in good agreement with the present results. The measurements are performed with photoionization mass spectrometry (PIMS) using a monochromated VUV synchrotron light source with an energy resolution of 40 meV (fwhm) comparable to that used for flame-sampling molecular beam PIMS studies of flame chemistry and reaction kinetics.

10 SYNTHETIC FUELS↗

Methane activation by cobalt cluster cations, Co{sub n}{sup +} (n=2-16): Reaction mechanisms and thermochemistry of cluster-CH{sub x} (x=0-3) complexes

The kinetic energy dependences of the reactions of Co{sub n}{sup +} (n=2-16) with CD{sub 4} are studied in a guided ion beam tandem mass spectrometer over the energy range of 0-10 eV. The main products are hydride formation, Co{sub n}D{sup +}, dehydrogenation to form Co{sub n}CD{sub 2}{sup +}, and double dehydrogenation yielding Co{sub n}C{sup +}. These primary products decompose to form secondary and higher order products, Co{sub n}CD{sup +}, Co{sub n-1}D{sup +}, Co{sub n-1}C{sup +}, Co{sub n-1}CD{sup +}, and Co{sub n-1}CD{sub 2}{sup +} at higher energies. Adduct formation of Co{sub n}CD{sub 4}{sup +} is also observed for the largest cluster cations, n{>=}10. In general, the efficiencies of the single and double dehydrogenation processes increase with cluster size, although the hexamer cation shows a reduced reactivity compared to its neighbors. All reactions exhibit thresholds, and cross sections for the various primary and secondary reactions are analyzed to yield reaction thresholds from which bond energies for cobalt cluster cations to D, C, CD, CD{sub 2}, and CD{sub 3} are determined. The relative magnitudes of these bond energies are consistent with simple bond order considerations. Bond energies for larger clusters rapidly reach relatively constant values, which are used to estimate the chemisorption energies of the C, CD, CD{sub 2}, and CD{sub 3} molecular fragments to cobalt surfaces.

36 MATERIALS SCIENCE↗