Search NASA⌕ Search

SEARCH · Search NASA

Results for “load Balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Power capture and power take-off load of a self-balanced dual-flap oscillating surge wave energy converter

Wave energy converters are an important part of future renewable energy infrastructure. Predicting their power matrix, capture width ratio, and power take-off loads at a targeted site is required for performance assessment before deployment. Because their testing is very expensive, numerical modeling and simulations play a significant role in those assessments. Linear potential flow theory has limited accuracy under large amplitude wave forcing. More accurate predictions can be obtained by using higher-fidelity models, which are computationally expensive. We present a framework for multi-fidelity numerical simulations to determine the hydrodynamic response, wave capture capability, and power take-off load of a full-scale dual-flap oscillating surge wave energy converter. This design exploits out-of-phase motion by setting the distance between the flaps to half the wavelength of the most occurring wave. The simulations are validated using a 1:10 model experiments in a wave tank. Based on these validations, it was determined that Euler simulations provide an acceptable prediction with 90% reduction in computational time with only 11% error. Utilizing Euler simulations at full-scale, the results demonstrate that the annual electrical energy output is 1.79 GWh under regular wave conditions. Here, one significant improvement over single-flap designs is the capture width ratio which exceeds unity.

16 TIDAL AND WAVE POWER↗

A Universal Threshold for the Assessment of Load and Output Residuals of Strain-Gage Balance Data

A new universal residual threshold for the detection of load and gage output residual outliers of wind tunnel strain{gage balance data was developed. The threshold works with both the Iterative and Non{Iterative Methods that are used in the aerospace testing community to analyze and process balance data. It also supports all known load and gage output formats that are traditionally used to describe balance data. The threshold's definition is based on an empirical electrical constant. First, the constant is used to construct a threshold for the assessment of gage output residuals. Then, the related threshold for the assessment of load residuals is obtained by multiplying the empirical electrical constant with the sum of the absolute values of all first partial derivatives of a given load component. The empirical constant equals 2.5 microV/V for the assessment of balance calibration or check load data residuals. A value of 0.5 microV/V is recommended for the evaluation of repeat point residuals because, by design, the calculation of these residuals removes errors that are associated with the regression analysis of the data itself. Data from a calibration of a six-component force balance is used to illustrate the application of the new threshold definitions to real{world balance calibration data.

wind tunnel balance↗

Explicit modeling and computational load distribution for concurrent processing simulation of the space station

Two important aspects of concurrent processing under development at TRW are discussed. These are: (1) the derivation of explicit mathematical models of multibody dynamic systems, and (2) a balanced computational load distribution (BCLD) among loosely coupled computational units (processors) of a concurrent processing system. The developed methodologies are demonstrated by way of an application to the Phase 1 of the Space Station - a task being performed by TRW under NASA/JSC contract NAS9-17778. The mathematical model of the Space Station consists of three interconnected flexible bodies capable of undergoing large, rigid-body motion with respect to each other. Body 1 is the main central body and contains the pressurized modules inboard of the two Alpha gimbals. Bodies 2 and 3 are the starboard and port bodies connected to Body 1 at the Alpha gimbals and include all components on the transverse booms outboard of the Alpha gimbals (including the solar arrays). The control systems in the model maintain Body 1 in a prescribed 3-axis attitude control mode, while producing large-angle rotations of the flexible solar arrays to position them normal to the sun-line.

Gluck, R.↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?: Preprint

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converterinterfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. An interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a variedlength transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

14 SOLAR ENERGY↗

A Universal Tare Load Prediction Algorithm for Strain-Gage Balance Calibration Data Analysis

An algorithm is discussed that may be used to estimate tare loads of wind tunnel strain-gage balance calibration data. The algorithm was originally developed by R. Galway of IAR/NRC Canada and has been described in the literature for the iterative analysis technique. Basic ideas of Galway's algorithm, however, are universally applicable and work for both the iterative and the non-iterative analysis technique. A recent modification of Galway's algorithm is presented that improves the convergence behavior of the tare load prediction process if it is used in combination with the non-iterative analysis technique. The modified algorithm allows an analyst to use an alternate method for the calculation of intermediate non-linear tare load estimates whenever Galway's original approach does not lead to a convergence of the tare load iterations. It is also shown in detail how Galway's algorithm may be applied to the non-iterative analysis technique. Hand load data from the calibration of a six-component force balance is used to illustrate the application of the original and modified tare load prediction method. During the analysis of the data both the iterative and the non-iterative analysis technique were applied. Overall, predicted tare loads for combinations of the two tare load prediction methods and the two balance data analysis techniques showed excellent agreement as long as the tare load iterations converged. The modified algorithm, however, appears to have an advantage over the original algorithm when absolute voltage measurements of gage outputs are processed using the non-iterative analysis technique. In these situations only the modified algorithm converged because it uses an exact solution of the intermediate non-linear tare load estimate for the tare load iteration.

balance calibration analysis↗

Forming Interphase Microgrids in Distribution Systems Using Cooperative Inverters

Interphase-microgrids formed by three islanded single-phase feeders in distribution systems are proposed in this paper. Loss of utility caused by natural and human-made disasters may isolate each residential subdivision from the utility. In this case, the household loads are supplied by distributed generation (DG) units which may not be enough to meet the load demand. This can lead to deviations in voltage and frequency, and the deviations may vary for each phase. The proposed solution is to form an interphase-microgrid by seamlessly interconnecting the islanded single-phase feeders. This interphase-microgrid can effectively balance the load demands and DG generation in distribution systems after losing the utility supply. This paper presents different case studies to demonstrate the viability of forming interphase-microgrids for residential distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Using Distributed Energy Resources to Reduce Peak Loads in Vermont

To help the United States develop a modern electricity grid that provides reliable power from multiple resources as well as resiliency under extreme conditions, the U.S. Department of Energy (DOE) is leading the Grid Modernization Initiative (GMI) to help shape the future of the nation's grid. Under the GMI, DOE funded the Vermont Regional Initiative project to provide the technical support and analysis to utilities that need to mitigate possible impacts of increasing renewable generation required by statewide goals. Advanced control of distributed energy resources (DER) can both support higher penetrations of renewable energy by balancing controllable loads to wind and photovoltaic (PV) solar generation and reduce peak demand by shedding noncritical loads. This work focuses on the latter. This document reports on an experiment that evaluated and quantified the potential benefits and impacts of reducing the peak load through demand response (DR) using centrally controllable electric water heaters (EWHs) and batteries on two Green Mountain Power (GMP) feeders. The experiment simulated various hypothetical scenarios that varied the number of controllable EWHs, the amount of distributed PV systems, and the number of distributed residential batteries. The control schemes were designed with several objectives. For the first objective, the primary simulations focused on reducing the load during the independent system operator (ISO) peak when capacity charges were the primary concern. The second objective was to mitigate DR rebound to avoid new peak loads and high ramp rates. The final objective was to minimize customers' discomfort, which is defined by the lack of hot water when it is needed. We performed the simulations using the National Renewable Energy Laboratory's (NREL's) Integrated Energy System Model (IESM) because it can simulate both electric power distribution feeder and appliance end use performance and it includes the ability to simulate multiple control strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of mpi_EPIC model for global agroecosystem modeling

Models that address policy-maker concerns about multi-scale effects of food and bioenergy production systems are computationally demanding. We integrated the message passing interface algorithm into the process-based EPIC model to accelerate computation of ecosystem effects. Simulation performance was further enhanced by applying the Vampir framework. When this enhanced mpi_EPIC model was tested, total execution time for a global 30-year simulation of a switchgrass cropping system was shortened to less than 0.5 hours on a supercomputer. The results illustrate that mpi_EPIC using parallel design can balance simulation workloads and facilitate large-scale, high-resolution analysis of agricultural production systems, management alternatives and environmental effects.

54 ENVIRONMENTAL SCIENCES↗

Improving Unstructured Mesh Partitions for Multiple Criteria Using Mesh Adjacencies

The scalability of unstructured mesh based applications depends on partitioning methods that quickly balance the computational work while reducing communication costs. Zhou et al. [SIAM J. Sci. Comput., 32 (2010), pp. 3201{3227; J. Supercomput., 59 (2012), pp. 1218{1228] demonstrated the combination of (hyper)graph methods with vertex and element partition improvement for PHASTA CFD scaling to hundreds of thousands of processes. Our work generalizes partition improvement to support balancing combinations of all the mesh entity dimensions (vertices, edges, faces, regions) in partitions with imbalances exceeding 70%. Improvement results are then presented for multiple entity dimensions on up to one million processes on meshes with over 12 billion tetrahedral elements.

97 MATHEMATICS AND COMPUTING↗

Investigating and Analyzing Applied Loads Higher Than Limit Loads

The results of the analysis for Balance 1621 indicate that the stresses are high near sharp corners. It is important to increase the size of the fillets to relieve some of the high stresses for the balances that will be designed. For the existing balances, the stresses are high and do not satisfy the established criteria. Two options are considered here. One is a possible modification of the existing balances, and two is to consider other load options. Redesigning a balance can be done in order to enhance the structural integrity of the balance. Because an existing balance needs to be modified, it is not possible to increase the fillet sizes without some further modifications to the balance. It is required that some materials be extracted from the balance in order to have larger fillet sizes. Researchers are interested in being able to apply some components of the load on the balance above the limit loads assigned. Is it possible to enhance the load on the same balance and maintain the factor of safety required? Some loads were increased above their limit loads and analyzed here.

Karkehabadi, R.↗

Detection and Use of Load and Gage Output Repeats of Wind Tunnel Strain-Gage Balance Data

Criteria are discussed that may be used for the detection of load and gage output repeats of wind tunnel strain-gage balance data. First, empirical thresholds are introduced that help determine if the loads or electrical outputs of a pair of balance calibration or check load data points match. A threshold of 0.01 percent of the load capacity is suggested for the identification of matching loads. Similarly, a threshold of 0.1 microV/V is recommended for the identification of matching electrical outputs. Two examples for the use of load and output repeats are discussed to illustrate benefits of the implementation of a repeat point detection algorithm in a balance data analysis software package. The first example uses the suggested load threshold to identify repeat data points that may be used to compute pure errors of the balance loads. This type of analysis may reveal hidden data quality issues that could potentially be avoided by making calibration process improvements. The second example uses the electrical output threshold for the identification of balance fouling. Data from the calibration of a six-component force balance is used to illustrate the calculation of the pure error of the balance loads.

strain-gage balance↗

Calibration and Data Analysis Recommendations for Three-Component Moment Balances

Fundamental characteristics of design, calibration, and application of three-component moment balances are investigated in great detail. These balances are typically used to determine loads on control surfaces, canards, or other parts that are attached to a wind tunnel model. First, three different descriptions of the load state of a moment balance are reviewed. Then, load transformations between different load formats and the combined load diagram for two of the three load components are discussed. An error analysis showed that it is critical to maximize the product of the distance between the bending moment gages and their sensitivities in order to minimize the overall error in the normal force prediction. In addition, it is important to apply a sufficient number of calibration loadings near the first bending moment gage. Then, unwanted near-linear dependencies between the two bending moment gage outputs can be avoided. The error in the bending moment prediction is also investigated that results from the elastic deformation of the metric part of the balance under load. Finally, the application of the Non-Iterative Method to three-component moment balance calibration data is described in order to obtain regression models that can be used to predict loads from measured outputs during a wind tunnel test.

Strain-Gage Balance↗

Built‐in Carbon Nanotube Network inside a Biomass‐Derived Hierarchically Porous Carbon to Enhance the Performance of the Sulfur Cathode in a Li‐S Battery

Abstract The practical application of lithium‐sulfur batteries is usually hindered by the unstable discharge intermediates and the low conductivity of the sulfur cathode. Herein, we propose to improve the performance of the sulfur cathode by introducing a built‐in carbon nanotube network inside a biomass‐derived hierarchically porous carbon for the subsequent sulfur loading. This balanced structural design of the carbon substrate enables effective trapping of active sulfur within the cathode and provides a highly efficient pathway for electron transmission, contributing to an increased conductivity and structural integrity of the cathode. By using a potentiostatic process at the end of charge, the reversibility of the electrode reaction of sulfur is improved. The sulfur cathode delivers an initial discharge capacity of 1739 mA h g −1 and reaches a high initial Columbic efficiency of 87.6 %, and maintains its efficiency to >97.5 % from the 2nd cycle. It also shows admirable cycling and rate performance.

Xu, Da‐Wei↗

Planning of distributed data production for High Energy and Nuclear Physics

Modern experiments in High Energy and Nuclear Physics heavily rely on distributed computations using multiple computational facilities across the world. One of the essential types of the computations is a distributed data production where petabytes of raw files from a single source has to be processed once (per production campaign) using thousands of CPUs at distant locations and the output has to be transferred back to that source. The data distribution over a large system does not necessary match the distribution of storage, network and CPU capacity. Therefore, bottlenecks may appear and lead to increased latency and degraded performance. In this paper we propose a new scheduling approach for distributed data production which is based on the network flow maximization model. In our approach a central planner defines how much input and output data should be transferred over each network link in order to maximize the computational throughput. Such plans are created periodically for a fixed planning time interval using up-to-date information on network, storage and CPU resources. The centrally created plans are executed in a distributed manner by dedicated services running at participating sites. In conclusion, our simulations based on the log records from the data production framework of the experiment STAR (Solenoid Tracker at RHIC) have shown that the proposed model systematically provides a better performance compared to the simulated traditional techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scalable multiscale modeling of platelets with 100 million particles

Here, we developed the core components of the AI-aided multiple time stepping algorithm for multiscale modeling of cell dynamics. This algorithm was implemented and analyzed on two supercomputer architectures with an application of simulating the aggregation of 250 platelets, or 102 million particles. To scale on these computers with complex memory and network architectures with GPUs, we devised a biomechanics-informed task mapping scheme to optimize load imbalance, communications, and memory utilization. Our simulations, scaling well up to 192 nodes on a Summit-like supercomputer with a peak speed of 11 petaflops, achieved a rate of 423 μs/day which is 500 times faster than the conventional algorithm using static time step and this has enabled studies of record size blood clots at record spatial–temporal resolutions. Additionally, we discovered the sensitive dependence of the scalability and execution time on the methods of decomposition, CPU–GPU coupling, and task mapping.

97 MATHEMATICS AND COMPUTING↗

Integrating high levels of variable renewable energy into electric power systems

As more variable renewable energy (VRE) such as wind and solar are integrated into electric power systems, technical challenges arise from the need to maintain the balance between load and generation at all timescales. This paper examines the challenges with integrating ultra-high levels of VRE into electric power system, reviews a range of solutions to these challenges, and provides a description of several examples of ultra-high VRE systems that are in operation today.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large-scale production of 88 Y and 88 Zr/ 88 Y generators: A proof of concept study for a 70 MeV H – cyclotron

Here, the large-scale production of 88 Y with proton-induced reactions has been investigated from the perspective of new generation 70 MeV H – cyclotrons. Tandem target configurations are presented for both the direct production of 88 Y as well as for producing 88 Zr/ 88 Y generators. Based on the relevant excitation functions, physical yields have been derived for 88 Y production with Y 2 O 3 /SrCO 3 tandem targets and 88 Zr production with Zr/Y 2 O 3 tandem targets. Yields are presented for optimized targets (i.e. optimum yield) as well as for balanced thermal loads on the individual targets. Liquid 88 Zr/ 88 Y generators have been produced using both natural Zr and Nb target materials, the former for dedicated productions and the latter as a byproduct by processing spent irradiated Nb capsules which normally would constitute radioactive waste. These stock solutions, which contain both the target material and 88 Zr precursor, are retained virtually unchanged after processing except for the removal of 88 Y on AG MP-50 macroporous cation-exchange resin. Methods are presented for the preparation of Nb stock solutions in hydrofluoric acid and Zr stock solutions in sulfuric acid. It is shown that multi-Ci productions of 88 Y are feasible at a 70 MeV cyclotron facility, suitable for the needs of fracking applications. In addition, 88 Zr/ 88 Y generators can provide 88 Y with very high specific activity, suitable for labelling of biomolecules.

07 ISOTOPE AND RADIATION SOURCES↗