Search NASA⌕ Search

SEARCH · Search NASA

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Experimental Investigation of Effects of Random Loading on the Fatigue Life of Notched Cantilever-Beam Specimens of 7075-T6 Aluminum Alloy

Results of random-loading fatigue tests on 125 notched cantilever-beam specimens and constant-amplitude fatigue tests on 46 similar specimens are presented in terms of the root-mean-square value of peak stresses. The results from the two sets of tests are compared on the basis of time to failure, where the results from the constant-amplitude tests are expressed in terms of an equivalent time to failure based on the natural period of vibration. Compared on this basis, failure at the lower stress levels occurred in a shorter time for the random loading than for the constant-amplitude loading, whereas at the higher stress levels failure occurred in the reverse order. A theoretical result for random loading is also presented and compared with the experimental results. The theoretical result shows good agreement with experiment for low values of stress but underestimates the time to failure at the higher stresses.

Fralich, Robert W.↗

Design, manufacture and spin test of high contact ratio helicopter transmission utilizing Self-Aligning Bearingless Planetary (SABP)

A 450 hp high ratio Self-Aligning Bearingless Planetary (SABP) for a helicopter application was designed, manufactured, and spin tested under NASA contract NAS3-24539. The objective of the program was to conduct research and development work on a high contact ratio helical gear SABP to reduce weight and noise and to improve efficiency. The results accomplished include the design, manufacturing, and no-load spin testing of two prototype helicopter transmissions, rated at 450 hp with an input speed of 35,000 rpm and an output speed of 350 rpm. The weight power density ratio of these gear units is 0.33 lb hp. The measured airborne noise at 35,000 rpm input speed and light load is 94 dB at 5 ft. The high speed, high contact ratio SABP transmission appears to be significantly lighter and quieter than comtemporary helicopter transmissions. The concept of the SABP is applicable not only to high ratio helicopter type transmissions but also to other rotorcraft and aircraft propulsion systems.

Folenta, Dezi↗

Development of a Fatigue Crack Growth Coupon for Highly Plastic Stress Conditions

The analytical approach used to develop a novel fatigue crack growth coupon for highly plastic stress field condition is presented in this paper. The flight hardware investigated is a large separation bolt that has a deep notch, which produces a large plastic zone at the notch root when highly loaded. Four test specimen configurations are analyzed in an attempt to match the elastic-plastic stress field and crack constraint conditions present in the separation bolt. Elastic-plastic finite element analysis is used to compare the stress fields and critical fracture parameters. Of the four test specimens analyzed, the modified double-edge notch tension - 3 (MDENT-3) most closely approximates the stress field, J values, and crack constraint conditions found in the flight hardware. The MDENT-3 is also most insensitive to load misalignment and/or load redistribution during crack growth.

Allen, Phillip A.↗

New Tools Being Developed for Engine- Airframe Blade-Out Structural Simulations

One of the primary concerns of aircraft structure designers is the accurate simulation of the blade-out event. This is required for the aircraft to pass Federal Aviation Administration (FAA) certification and to ensure that the aircraft is safe for operation. Typically, the most severe blade-out occurs when a first-stage fan blade in a high-bypass gas turbine engine is released. Structural loading results from both the impact of the blade onto the containment ring and the subsequent instantaneous unbalance of the rotating components. Reliable simulations of blade-out are required to ensure structural integrity during flight as well as to guarantee successful blade-out certification testing. The loads generated by these analyses are critical to the design teams for several components of the airplane structures including the engine, nacelle, strut, and wing, as well as the aircraft fuselage. Currently, a collection of simulation tools is used for aircraft structural design. Detailed high-fidelity simulation tools are used to capture the structural loads resulting from blade loss, and then these loads are used as input into an overall system model that includes complete structural models of both the engines and the airframe. The detailed simulation (shown in the figure) includes the time-dependent trajectory of the lost blade and its interactions with the containment structure, and the system simulation includes the lost blade loadings and the interactions between the rotating turbomachinery and the remaining aircraft structural components. General-purpose finite element structural analysis codes are typically used, and special provisions are made to include transient effects from the blade loss and rotational effects resulting from the engine s turbomachinery. To develop and validate these new tools with test data, the NASA Glenn Research Center has teamed with GE Aircraft Engines, Pratt & Whitney, Boeing Commercial Aircraft, Rolls-Royce, and MSC.Software.

Lawrence, Charles↗

Reducing Internal Resistance in Activated Carbon Supercapacitors via Exfoliated Coal-Derived Graphene Additive

Low equivalent series resistance (ESR) is critical for high-rate energy storage devices (e.g., supercapacitors), and graphene is a promising additive for reducing ESR in carbon-based supercapacitor electrodes. However, graphene can be costly and difficult to produce at scale. This study investigates the addition of graphene, produced through electrochemical exfoliation of domestic coal-derived graphite, in activated carbon-based supercapacitors. The coal-derived graphene was incorporated at varying weight loadings and tested in symmetric supercapacitors with aqueous electrolytes. ESR was evaluated using both direct current internal resistance (DCIR) and electrochemical impedance spectroscopy (EIS) measurements. DCIR measurements revealed ESR reductions of ∼34%, ∼18%, and ∼21% at 3, 5, and 10 wt % loadings, respectively, compared to the baseline (0 wt %) of ∼0.54 Ω. These results were further confirmed by EIS measurements. Correspondingly, power density increased by ∼52%, ∼27%, and ∼35% at 3, 5, and 10 wt % loadings relative to the baseline (∼29 kW/kg). Additionally, the electrodes exhibited moderate increases in specific capacitance and energy density, along with stable cycling performance (capacitance retention above 85% after 100,000 cycles) and capacitive behavior (α = 0.95−0.97), suggesting favorable charge transfer kinetics. These findings highlight the potential of exfoliated coal-derived graphene as an effective additive for supercapacitor electrodes.

capacitors↗

Fracture Strength of Silicon Solar Cells

Tests during processing show way to reduce breakage and increase yield. Silicon wafer twisted by four equally spaced dowel pins, two pushing up and two pushing down. Uniform shear stress found along line 45 degrees from axes of two load pairs. Test helping to develop reliable information on nature and source of flows causing cell fracture.

Chen, C. P.↗

Design and Flight Evaluation of a New Force-Based Flow Angle Probe

A novel force-based flow angle probe was designed and flight tested on the NASA F-15B Research Testbed aircraft at NASA Dryden Flight Research Center. The prototype flow angle probe is a small, aerodynamic fin that has no moving parts. Forces on the prototype flow angle probe are measured with strain gages and correlated with the local flow angle. The flow angle probe may provide greater simplicity, greater robustness, and better access to flow measurements in confined areas relative to conventional moving vane-type flow angle probes. Flight test data were obtained at subsonic, transonic, and supersonic Mach numbers to a maximum of Mach 1.70. Flight conditions included takeoff, landing, straight and level flight, flight at higher aircraft angles of attack, and flight at elevated g-loadings. Flight test maneuvers included angle-of-attack and angle-of-sideslip sweeps. The flow angle probe-derived flow angles are compared with those obtained with a conventional moving vane probe. The flight tests validated the feasibility of a force-based flow angle measurement system.

Corda, Stephen↗

Repurposing the James Webb Space Telescope’s center of curvature optical bench hexapod for future mirror calibration testing at NASA Marshall’s x-ray & cryogenic facility

The James Webb Space Telescope’s (JWST) center of curvature optical bench (CoCOB) hexapod was repurposed to enhance NASA Marshall Space Flight Center’s X-Ray & Cryogenic Facility (XRCF) optical metrology capabilities. This upgrade unlocked higher test article load capacity and extended the allowable ranges of motion of the CoCOB hexapod. The hexapod was also coupled to a new long-stroke, linear motion axis to form a 7 degrees of freedom system and allow for high precision testing of larger diameter test articles. A 9 degrees of freedom motion system, consisting of a three-axis linear mount in an X-Y-Z configuration and a commercially available hexapod, was also designed to allow high resolution positioning of the focal plane instrumentation over a large range of motion. A modern control architecture and graphical user interface was developed for the CoCOB hexapod and additional motion stages to permit streamlined commanding and operation. This paper discusses the justification for re-using the CoCOB hexapod by highlighting its unique precision motion control capabilities in a high vacuum and optically clean environment. The design, key component selection, and environmental compatibility for each of the additional motion stages is presented along with testing results for achieved range, repeatability, and minimum step size performance for all motion axes. Finally, a summary of the motion control system architecture and its flexibility to address tomorrow’s optical metrology needs are presented.

hexapod↗

Behavior of Compression-Loaded Composite Panels with Stringer Terminations and Impact Damage

The results of an analytical and experimental study of graphite-epoxy stiffened panels with impact-damaged stringer terminations are presented. Five stitched graphite-epoxy panels with stiffeners with a gradual reduction in either thickness or height were examined. Panels were analyzed using finite element analysis and tested by loading them in axial compression to a predetermined load. The panels were then subjected to impact damage and loaded to failure. Axial midplane strains, surface strains, interlaminar strains and failure results are discussed.

Jegley, Dawn C.↗

Examination, evaluation and repair of laminated wood blades after service on the Mod-OA wind turbine

Laminated wood blades were designed, fabricated, and installed on a 200-KW wind turbine (Mod-OA). The machine uses a two-blade rotor with a diameter of 38.1 m (125 ft). Each blade weights less than 1361 kg (3000 lb). After operating in the field, two blade sets were returned for inspection. One set had been in Hawaii for 17 months (7844 hr of operation) and the other had been at Block Island, Rhode Island, for 26 months (22 months operating - 7564 hr). The Hawaii set was returned because of one of the studs that holds the blade to the hub had failed. This was found to be caused by a combination of improper installation and inadequate corrosion protection. No other problems were found. The broken stud (along with four others that were badly corroded) was replaced and the blades are now in storage. The Block Island set of blades was returned at the completion of the test program, but one blade was found to have developed a crack in the leading edge along the entire span. This crack was found to be the result of a manufacturing process problem but was not structurally critical. When a load-deflection test was conducted on the cracked blade, the response was identical to that measured before installation. In general, the laminate quality of both blade sets was excellent. No significant internal delamination or structural defects were found in any blade. The stud bonding process requires close tolerance control and adequate corrosion protection, but studs can be removed and replaced without major problems. Moisture content stabilization does not appear to be a problem, and laminated wood blades are satisfactory for long-term operation on Mod-OA wind turbines.

Faddoul, J. R.↗

Loftid Aeroshell Engineering Development Unit Structural Testing

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology was selected for a Technology Demonstration Mission under the Space Technology Mission Directorate in 2017. HIAD is an enabling technology that can facilitate atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to avoid the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher pay-load mass and/or volume, higher landing altitude at Mars). The Low Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is currently scheduled for late-2021. LOFTID will be launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. The flight test features a 6m diameter, 70-deg sphere-cone aeroshell and will provide invaluable high-energy orbital re-entry flight data. This data will be essential in supporting the HIAD team to mature the technology to diameters of 10m and greater. Aeroshells of this scale are applicable to potential near-term commercial applications and future NASA missions. Currently the LOFTID project has completed fabrication of the engineering design unit (EDU) inflatable structure (IS) and the flexible thermal protection system (F-TPS). These two components along with the rigid nose and center body comprise the HIAD aeroshell system. This EDU aeroshell is the precursor to the LOFTID aeroshell that will be used for flight. The EDU was built to verify the design given the subtle differences between the LOFTID aeroshell and past aeroshell designs that have been fabricated under the NASA HIAD project. To characterize the structural performance of the LOFTID aeroshell design, three structural tests will be performed. The first test to be conducted is static load testing, which will induce a uniform load across the forward surface of the aeroshell to simulate the expected pressure forces during atmospheric entry. The IS integrated with the rigid center body will first be tested alone to provide data for analytical model correlation, and then the F-TPS will be integrated for a second series of static load testing of the full aeroshell system. Instrumentation will be employed during the test series to measure component loads during testing, and a laser scanner will be used to generate a 3D map of the aeroshell surface to verify that the shape of the structure is acceptable at the simulated flight loads. After static load testing, pack and deployment testing will be conducted multiple times on the integrated system to demonstrate the aeroshell’s ability to fit within the required packed volume for the LOFTID mission without experiencing significant damage. Finally, the aeroshell will undergo modal testing to characterize its structural response. This presentation will discuss the setup and execution of each of the three tests that the EDU aeroshell will undergo. In addition, initial results of the testing will be presented outlining key findings as LOFTID moves for-ward with fabrication of the flight aeroshell.

Swanson, G. T.↗

Accelerated fatigue durability of a high performance composite

The fatigue behavior of multidirectional graphite-epoxy laminates was analyzed theoretically and experimentally in an effort to establish an accelerated testing methodology. Analysis of the failure mechanism in fatigue of the laminates led to the determination of the failure mode governing fracture. The nonlinear, cyclic-dependent shear modulus was used to calculate the changing stress field in the laminate during the fatigue loading. Fatigue tests were performed at three different temperatures: 25 C, 74 C, and 114 C. The prediction of the S-N curves was made based on the artificial static strength artificial static strength at a reference temperature and the fatigue functions associated with them. The prediction of an S-N curve at other temperatures was performed using shifting factors determined for the specific failure mode. For multidirectional laminates, different S-N curves at different temperatures could be predicted using these shifting factors. Different S-N curves at different temperatures occur only when the fatigue failure mode is matrix dominated. It was found that whenever the fatigue failure mode is fiber dominated, temperature, over the range investigated, had no influence on the fatigue life. These results permit the prediction of long-time, low temperature fatigue behavior from data obtained in short time, high temperature testing, for laminates governed by a matrix failure mode.

Rotem, A.↗

An examination of the relations between rotor vibratory loads and airframe vibrations

Harmonic rotor hub loads and airframe interactions in steady flight are reviewed, with regard to the objective of achieving lower airframe vibration by modifying blade root loads. Flight test and wind tunnel data are reviewed, along with sample fuselage response data. Trends which could provide a generalized approach to the above objective are found to be very limited. Recent analytical and corresponding experimental blade tuning modifications are reviewed and compared. Rotor vibratory load modification and substantial vibration changes were achieved over a wide range of rotor operating conditions.

Niebanck, C. F.↗

Fatigue-test acceleration with flight-by-flight loading and heating to simulate supersonic-transport operation

Possibilities for reducing fatigue-test time for supersonic-transport materials and structures were studied in tests with simulated flight-by-flight loading. In order to determine whether short-time tests were feasible, the results of accelerated tests (2 sec per flight) were compared with the results of real-time tests (96 min per flight). The effects of design mean stress, the stress range for ground-air-ground cycles, simulated thermal stress, the number of stress cycles in each flight, and salt corrosion were studied. The flight-by-flight stress sequences were applied to notched sheet specimens of Ti-8Al-1Mo-1V and Ti-6Al-4V titanium alloys. A linear cumulative-damage analysis accounted for large changes in stress range of the simulated flights but did not account for the differences between real-time and accelerated tests. The fatigue lives from accelerated tests were generally within a factor of two of the lives from real-time tests; thus, within the scope of the investigation, accelerated testing seems feasible.

Imig, L. A.↗

Free-spinning-tunnel Tests of a 1/26th Scale Model of the Douglas XTB2D-1 Airplane

A spin-tunnel investigation of a 1/26 scale model of the Douglas XTB2D-1 airplane has been conducted in the Langley 20-foot free-spinning tunnel. The effects of control settings and movements upon the erect- and inverted-spin and recovery characteristics of the model were determined for various loading conditions. Tests were also performed to determine the effects of various tail modifications. The investigation included emergency spin-recovery parachute tests as well as crew-escape and rudder- and elevator-force tests. All tests were performed at an equivalent spin altitute of 20,000 feet. The recovery characteristics of the model in the original design were found to be unsatisfactory. Installation of a large ventral fin, installation of tip fins on the horizontal tail, or installation of a small ventral fin in combination with antispan fillets and a spanwise extension of the horizontal-tail surfaces satisfactorily improved the recovery characteristics of the model.

Stone, Ralph W↗

Performance and loads data from a hover test of a full-scale XV-15 rotor

A hover test of a full-scale XV-15 rotor was conducted at the Outdoor Aerodynamic Research Facility at Ames Research Center. The primary objective of the test was to obtain accurate measurements of the hover performance of the original, metal-blade XV-15 rotor system. Data were acquired for rotor tip Mach numbers ranging from 0.60 to 0.73. This report presents data on rotor performance, rotor wake downwash velocities, and rotor loads.

Felker, F. F.↗

Assessment of the Uniqueness of Wind Tunnel Strain-Gage Balance Load Predictions

A new test was developed to assess the uniqueness of wind tunnel strain-gage balance load predictions that are obtained from regression models of calibration data. The test helps balance users to gain confidence in load predictions of non-traditional balance designs. It also makes it possible to better evaluate load predictions of traditional balances that are not used as originally intended. The test works for both the Iterative and Non-Iterative Methods that are used in the aerospace testing community for the prediction of balance loads. It is based on the hypothesis that the total number of independently applied balance load components must always match the total number of independently measured bridge outputs or bridge output combinations. This hypothesis is supported by a control volume analysis of the inputs and outputs of a strain-gage balance. It is concluded from the control volume analysis that the loads and bridge outputs of a balance calibration data set must separately be tested for linear independence because it cannot always be guaranteed that a linearly independent load component set will result in linearly independent bridge output measurements. Simple linear math models for the loads and bridge outputs in combination with the variance inflation factor are used to test for linear independence. A highly unique and reversible mapping between the applied load component set and the measured bridge output set is guaranteed to exist if the maximum variance inflation factor of both sets is less than the literature recommended threshold of five. Data from the calibration of a six{component force balance is used to illustrate the application of the new test to real-world data.

strain-gage balance↗