Simulator study of the effect of control-system time delays on the occurrence of pilot-induced oscillations and on pilot tracking performance with a space-shuttle-orbiter configuration

Using a six degree-of-freedom motion-base simulator, the effect of control-system time delays on the occurrence of pilot-induced oscillations (PIO's) on the vehicle handling qualities and on pilot tracking performance for a landing-approach configuration of the Space Shuttle orbiter was studied. A linearized math model was employed which represented a 300-knot orbiter with almost all time delays removed. Additional time delays were then inserted following the pilot's hand-controller signals. Only pitch and roll commands were used for vehicle control. The simulation employed an air to air tracking task as a means of emphasizing PIO tendencies. Two astronauts, two research pilots, and one simulation engineer served as test subjects. Results showed that PIO's occurred when the amount of added time delay approximated that existing for the orbiter configuration flown in the approach and landing tests. Increasing the amount of delay increased PIO occurrences and resulted in degraded tracking performance. Decreasing the amount of time delay eliminated the PIO's.

Riley, D. R.↗

TU-AB-303-11: Predict Parotids Deformation Applying SIS Epidemiological Model in H&N Adaptive RT

Purpose: The aim is to investigate the use of epidemiological models to predict morphological variations in patients undergoing radiation therapy (RT). The susceptible-infected-susceptible (SIS) deterministic model was applied to simulate warping within a focused region of interest (ROI). Hypothesis is to consider each voxel like a single subject of the whole sample and to treat displacement vector fields like an infection. Methods: Using Raystation hybrid deformation algorithms and automatic re-contouring based on mesh grid, we post-processed 360 MVCT images of 12 H&N patients treated with Tomotherapy. Study focused on parotid glands, identified by literature and previous analysis, as ROI more susceptible to warping in H&N region. Susceptible (S) and infectious (I) cases were identified in voxels with inter-fraction movement respectively under and over a set threshold. IronPython scripting allowed to export positions and displacement data of surface voxels for every fraction. A MATLAB homemade toolbox was developed to model the SIS. Results: SIS model was validated simulating organ motion on QUASAR phantom. Applying model in patients, within a [0–1cm] range, a single voxel movement of 0.4cm was selected as displacement threshold. SIS indexes were evaluated by MATLAB simulations. Dynamic time warping algorithm was used to assess matching between model and parotids behavior days of treatments. The best fit of the model was obtained with contact rate of 7.89±0.94 and recovery rate of 2.36±0.21. Conclusion: SIS model can follow daily structures evolutions, making possible to compare warping conditions and highlighting challenges due to abnormal variation and set-up errors. By epidemiology approach, organ motion could be assessed and predicted not in terms of average of the whole ROI, but in a voxel-by-voxel deterministic trend. Identifying anatomical region subjected to variations, would be possible to focus clinic controls within a cohort of pre-selected patients eligible for adaptive RT. The research is partially co-funded by the Italian Research Grant: Dose warping methods for IGRT and Adaptive RT: dose accumulation based on organ motion and anatomical variations of the patients during radiation therapy treatments,MoH (GR-2010-2318757) and Tecnologie Avanzate S.r.l.(Italy)

60 APPLIED LIFE SCIENCES↗

Simulations of radiation damage as a function of the temporal pulse profile in femtosecond X-ray protein crystallography

Serial femtosecond X-ray crystallography of protein nanocrystals using ultrashort and intense pulses from an X-ray free-electron laser has proved to be a successful method for structural determination. However, due to significant variations in diffraction pattern quality from pulse to pulse only a fraction of the collected frames can be used. Experimentally, the X-ray temporal pulse profile is not known and can vary with every shot. This simulation study describes how the pulse shape affects the damage dynamics, which ultimately affects the biological interpretation of electron density. The instantaneously detected signal varies during the pulse exposure due to the pulse properties, as well as the structural and electronic changes in the sample. Here ionization and atomic motion are simulated using a radiation transfer plasma code. Pulses with parameters typical for X-ray free-electron lasers are considered: pulse energies ranging from 10 4 to 10 7 J cm -2 with photon energies from 2 to 12 keV, up to 100 fs long. Radiation damage in the form of sample heating that will lead to a loss of crystalline periodicity and changes in scattering factor due to electronic reconfigurations of ionized atoms are considered here. The simulations show differences in the dynamics of the radiation damage processes for different temporal pulse profiles and intensities, where ionization or atomic motion could be predominant. Overall, the different dynamics influence the recorded diffracted signal in any given resolution and will affect the subsequent structure determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pore-scale CFD simulations of clay mobilization in natural porous media due to fresh water injection

The present work investigates mechanisms of permeability impairment as a result of low-salinity fluid injection into brine-saturated porous media containing dispersible clays. Here, we present a computational fluid dynamics model at the pore-scale to simulate detachment, migration and straining of fine particles in porous media. The model uses an immersed boundary method to simulate the motion of clay fines in a fluid. In addition to the hydrodynamic forces, we model the Derjaguin-Landau-Verwey-Overbeek forces (DLVO) between clay fines and grains. Our simulations show the impact of the injected fluid's salinity and velocity on the concentration of clay fines retained on the grain surface. We see clay particles dislodging from the grain surface in clusters of up to 12 particles. Our simulation results also demonstrate clogging of narrow pore spaces by the detached particles from the grain surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-389: Validation in 4D Dosimetry Using Dynamic Phantom

Purpose: Tumor motion due to respiration causes the uncertainties during the radiotherapy. This study aims to find the differences between planning dose by treatment planning and the received dose using dynamic phantom. Methods: Respiratory motion was simulated by the DYNAMIC THORAX PHANTOM (Model 008A). 4D-CT scans and maximum intensity projection (MIP) images for GTV were acquired for analysis. The amplitude of craniocaudal tumor motion including 2mm, 5mm, 10mm and 20mm with 3cm2 tumor size were performed in this study. The respiratory cycles of 4-seconds and 6-seconds were included as the different breathing modes. IMRT, VAMT, and Tomotherapy were utilized for treatment planning. Ion chamber and EBT3 were used to measure the point dose and planar dose. Dose distributions with different amplitudes, respiratory cycles, and planning techniques were all measured and compared to calculations. Results: The variations between the does measurements and calculation dose by treatment planning system were found in both point dose and dose distribution. The 0.83% and 5.46 % differences in dose average were shown on phantom with motions using 2mm amplitude in 4 second respiratory cycle, and 20mm amplitude in 4 second respiratory cycle, respectively. The most point dose overestimation as compared of the calculations was shown the plan generated by Tomotherapy. The underestimations of planar dose as compared of calculations was found in the 100% coverage doses for GTV. Conclusion: The loss of complete (100%) GTV coverage was the predominant effect of respiratory motion observed in this study. Motion amplitude and treatment planning system were the major factors leading the dose measurement variation as compared of planning calculations.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signals recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.

60 APPLIED LIFE SCIENCES↗

Transient dynamic analysis of high-speed lightly loaded cylindrical roller bearings. 2: Computer program and results

The governing differential equations of motion for a high speed cylindrical roller bearing are programmed for numerical solution and plotted output. This computer program has the capability of performing a two dimensional or three dimensional simulation. Two numerical solutions of the governing differential equations were obtained to simulate the motion of a roller bearing, one for the two dimensional equations of motion and one for the three dimensional equations of motion. Computer generated plots were obtained and present such data as roller/cage interaction forces, roller/race traction forces, roller/race relative slip velocities and cage angular speed over a nondimensional time equivalent to 1.2 revolutions of the inner race. Roller axial displacement, roller skew angle, and skew moment are also plotted for the three dimensional solution. The trajectory of the cage center is plotted for both the two dimensional and three dimensional solutions.

Conry, T. F.↗

On the simulation of space based manipulators with contact

An efficient method of simulating the motion of space based manipulators is presented. Since the manipulators will come into contact with different objects in their environment while carrying out different tasks, an important part of the simulation is the modeling of those contacts. An inverse dynamics controller is used to control a two armed manipulator whose task is to grasp an object floating in space. Simulation results are presented and an evaluation is made of the performance of the controller.

Walker, Michael W.↗

Suppression of biodynamic interference in head-tracked teleoperation

Results are reported from an experimental simulation study examining improvements achievable in pointing and tracking precision using dynamic display shifting in helmet-mounted displays. The experiment was conducted in a 6-deg-of-freedom motion base simulator with an emulated helmet-mounted sight. It is shown that, for tracking tasks involving continuously moving targets, improvements of up to 70 percent can be achieved in percent on-target dwelling time and of up to 35 percent in rms tracking error, with the adaptive plus low-pass filter configuration. The results with the same filter configuration for the task of capturing randomly positioned, stationary targets show an increase of up to 340 percent in the number of targets captured and an improvement of up to 24 percent in the average capture time. The adaptive plus low-pass filter combination is considered to exhibit the best overall display dynamics by each of the subjects.

Lifshitz, S.↗

Visual Performance Challenges to Low-Frequency Perturbations After Long-Duration Space Flight, and Countermeasure Development

Astronauts experience sensorimotor disturbances after long-duration space flight. After a water landing, crewmembers may need to egress the vehicle within a few minutes for safety and operational reasons in various sea state conditions. Exposure to even low-frequency motions induced by sea conditions surrounding a vessel can cause significant motor control problems affecting critical functions. The first objective of this study was to document human visual performance during simulated wave motion below 2.0 Hz. We examined the changes in accuracy and reaction time when subjects performed a visual target acquisition task in which the location of the target was offset vertically during horizontal rotation at an oscillating frequency of 0.8 Hz. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements occurring when vertical targets were acquired at perturbing frequencies of 0.8 Hz in the horizontal plane. A second objective was to develop a countermeasure, base d on stochastic resonance (SR), to enhance sensorimotor capabilities with the aim of facilitating rapid adaptation to gravitational transitions after long-duration space flight. SR is a mechanism by which noise can enhance the response of neural systems to relevant sensory signals. Recent studies have shown that applying imperceptible stochastic electrical stimulation to the vestibular system (SVS) significantly improved balance and oculomotor responses. This study examined the effectiveness of SVS on improving balance performance. Subjects performed a standard balance task while bipolar SVS was applied to the vestibular system using constant current stimulation through electrodes placed over the mastoid process. The main finding of this study was that balance performance with the application of SR showed significant improvement in the range of 10%-25%. Ultimately an SR-based countermeasure might be fielded either as preflight training to enhance adaptability, or as a miniature patch-type stimulator worn post flight.

Mulavara, Ajitkumar↗

Effects of thrust reversing in ground proximity

The changes in stability and control characteristics encountered by a thrust reversing aircraft during its final approach, landing, and ground roll are described. These changes include a strong pitch-up accompanied by the loss of horizontal tail and aileron control effectiveness. The magnitude of reverser induced changes in ground effect are much larger than corresponding changes in free air. Some unexpected unsteady motions exhibited in wind tunnel by an aircraft model with reversers operating in ground proximity are also described. The cause of this oscillatory behavior was determined to be an unsteady interaction between the wall jets formed by impingement of reverser jets on the ground and the on-coming free stream. Time histories of rolling moments measured by the wind tunnel balance or support system were removed and frequencies were scaled by Strouhal number to full scale. Corrected time series were used to simulate the motion of a fighter aircraft with thrust reversers in ground effect. The simulation predicted large roll angles and nose down attitude at touchdown. Some phenomena of jet attachment to solid surfaces are discussed and areas for future research are recommended.

Joshi, P. B.↗

Piloted-simulation study of effects of vortex flaps on low-speed handling qualities of a Delta-wing airplane

A piloted-simulation study was conducted to investigate the effects of vortex flaps on low-speed handling qualities of a delta-wing airplane. The simulation math model was developed from wind tunnel tests of a 0.15 scale model of the F-106B airplane. Pilot evaluations were conducted using a six-degree-of-freedom motion base simulator. The results of the investigation showed that the reduced static longitudinal stability caused by the vortex flaps significantly degraded handling qualities in the approach-to-landing task. Acceptable handling qualities could be achieved by limiting the aft center-of-gravity location, consequently reducing the operational envelope of the airplane. Further improvement were possible by modifying the flight control force-feel system to reduce pitch-control sensitivity.

Brandon, Jay M.↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cloud scale influences on mesoscale precipitation patterns

A two dimensional time dependent finite difference grid cloud model is discussed. The model simulates atmospheric motions, potential temperature, water vapor, cloud liquid, cloud ice, rain and small hail. Lateral boundary conditions are open allowing flow in and out of the model domain. Various amounts of convergence were simulated to test the effects on cloud initiation and development. Soundings were run and results discussed.

Kopp, F. J.↗

PEBBLES

The PEBBLES code is a computer program designed to simulate the motion, packing and vibration of spheres that undergo various mechanical forces including gravitation, Hooke's law force and various friction forces. The frictional forces include true static friction that allows non-zero angles of repose. Each pebble is individually simulated using the distinct element method. The program outputs various tallies as textual numbers. These tallies include pebble position, pebble angular and linear velocity, force on the wall and between pebbles, probabilities of pebbles moving between different locations, accumulated amount of linear motion between pebbles, and average velocity in different regions of the container.

Cogliati, JoshuaJ.↗

Rupture Dynamics Simulations of Shallow Crustal Earthquakes on Reverse Slip Faults

The main goal of this study was to perform dynamic rupture simulations in order constrain the characterization of kinematic rupture models implemented in techniques for simulating strong ground motion for crustal earthquakes. First, we investigated the rupture process of the 2008 Iwate-Miyagi Nairiku earthquake by developing a dynamic rupture model on a reverse fault using a trial-and-error technique that produced a slip distribution and near-fault ground motion that matched the recorded ones. The simulations were performed in the frequency range 0-2 Hz, using a 3D staggered grid finite-difference method and a linear slip weakening friction law. Constrained by the observed slip distribution and consistent with dynamic rupture models, the derived kinematic rupture model of the Iwate-Miyagi Nairiku earthquake contains areas with relatively large slip rate, representing strong motion generation areas, set against lower amplitude heterogeneous background slip, and a relatively low slip rate in the weak zone of the top-most crust (upper 3km). Second, we performed rupture dynamics modeling to constrain shallow slip characterization in rupture models for strike-slip crustal earthquakes. The objective was to establish general rules about the characterization of slip rate function and slip at shallow depths and in the strong motion generation areas (SMGAs). The simulations of spontaneous rupture were performed in the frequency range 0-2.0Hz, using a 3D staggered-grid finite-difference method and a layer over half-space 1D crustal velocity model with a minimum shear-wave velocity of 2.8 km/s. In order to account for changes in material ductility and reduction of stress drop, observed in the shallow crust (upper 3-5 km), and the transition from ductile state to brittle state in the upper seismogenic zone, in our stress models we included a shallow weak zone (<4km). In this zone the stress drop was set to zero at the free surface and gradually increased with depth, while the slip weakening distance was set to 75 cm at the free surface and decreased to 50 cm at the base of the weak zone. As in the case of reverse faulting during the Iwate-Miyagi Nairiku earthquake, from these computations we found a systematic change in the shape of the slip-rate function, from Kostrov-type in the deeper part of the fault to a more symmetric cosine-type in the upper few kilometers, near the free-surface. Moreover, the average slip duration in the weak zone, with respect to slip duration in the deeper parts of the fault, increases by at most a factor of 1.5. We found a systematic and gradual change in the shape of the slip-rate function from Kostrov-type in the asperity areas (SMGAs), to more symmetric cosine-type in the upper few km near the free-surface, on the long period motion generation area (LMGA). The effective rise time in the LMGA, with respect to that in the SMGAs, increases by at most a factor of 2. Effective rise time is the time difference between the time at which the slip rate drops to a level that is equal to 25% of its peak and the onset time of the signal. In addition, the slip in the LMGA located above the SMGAs is almost the same as the one in the SMGAs, and about 1.5 times larger than the average slip.

58 GEOSCIENCES↗

Results of NASA/FAA ground and flight simulation experiments concerning helicopter IFR airworthiness criteria

A sequence of ground and flight simulation experiments was conducted to investigate helicopter instrument-flight-rules airworthiness criteria. The first six of these experiments and major results are summarized. Five of the experiments were conducted on large-amplitude motion base simulators. The NASA-Army V/STOLAND UH-1H variable-stability helicopter was used in the flight experiment. Artificial stability and control augmentation, longitudinal and lateral control, and in pitch and roll attitude augmentation were investigated.

Lebacqz, J. V.↗

A summary of NASA/FAA experiments concerning helicopter IFR airworthiness criteria

A sequence of ground and flight simulation experiments was conducted to investigate helicopter instrument-flight-rules airworthiness criteria. The first six of these experiments and major results are summarized. Five of the experiments were conducted on large-amplitude motion base simulators. The NASA-Army V/STOLAND UH-1H variable-stability helicopter was used in the flight experiment. Artificial stability and control augmentation, longitudinal and lateral control, and in pitch and roll attitude augmentation were investigated. Previously announced in STAR as N82-23219