Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Proton NMR spectra of lignin isolated from field grown transgenic poplar

Here we present a curated dataset of a series of 1H nuclear magnetic resonance (NMR) spectra of lignin isolated from transgenic monolignol 4-O-methyltransferase (MOMT4) engineered poplar. The transgenic poplar was collected from a 2-year-old rotation trees within a three-year field trial experiment. Two replicates were collected for each transgenic poplar for the 1H NMR analysis. The poplar samples were Soxhlet-extracted with toluene/ethanol to remove the extractives and the extractives-free poplar was then ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h. The ball-milled materials were subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96:4 (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide and transferred into a 5 mm NMR tube. 1H NMR experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence (zg) on a Prodigy platform cryoprobe. The NMR spectra were acquired with 16 ppm spectra width, 32k data points, 3s pulse delay, and 16 scans. All the data was processed using the Bruker’s TopSpin 3.6 software. Additional meta data is embedded in the raw spectra files.

1H NMR, lignin, poplar, field trial, MOMT4, CBI↗

Explicit expressions of quantum mechanical rotation operators for spins 1 to 2

Quantum mechanical rotation operators are the subject of quantum mechanics, mathematics and pulsed magnetic resonance spectroscopies, namely NMR, EPR and ENDOR. They are also necessary for spin based quantum information systems. The rotation operators of spin 1/2 are well known and can be found in related textbooks. But rotation operators of other spins greater than 1/2 can be found numerically by evaluating the series expansions of exponential operator obtained from Schrödinger equation, or by evaluating Wigner-d formula or by evaluating recently established expressions in polynomial forms discussed in the text. In this work, explicit symbolic expressions of x, y and z components of rotation operators for spins 1 to 2 are worked out by evaluating series expansion of exponential operator for each element of operators and utilizing linear curve fitting process. The procedures gave out exact expressions of each element of the rotation operators. The operators of spins greater than 2 are under study and will be published in a separate paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Resonance-Enhanced Multiphoton Ionization in the X-Ray Regime

In this work, we report on the nonlinear ionization of argon atoms in the short wavelength regime using ultraintense x rays from the European XFEL. After sequential multiphoton ionization, high charge states are obtained. For photon energies that are insufficient to directly ionize a 1s electron, a different mechanism is required to obtain ionization to Ar 17+ . We propose this occurs through a two-color process where the second harmonic of the FEL pulse resonantly excites the system via a 1s→2p transition followed by ionization by the fundamental FEL pulse, which is a type of x-ray resonance-enhanced multiphoton ionization (REMPI). This resonant phenomenon occurs not only for Ar 16+ , but also through lower charge states, where multiple ionization competes with decay lifetimes, making x-ray REMPI distinctive from conventional REMPI. With the aid of state-of-the-art theoretical calculations, we explain the effects of x-ray REMPI on the relevant ion yields and spectral profile.

74 ATOMIC AND MOLECULAR PHYSICS↗

Extracting Short Rise-Time Velocity Profiles with Digital Down-Shift Analysis of Optically Up-Converted PDV Data

This work describes the digital down-shift (DDS) technique, a new method of extracting short rise-time velocity profiles in the analysis of optically up-converted PDV data. The DDS technique manipulates the PDV data by subtracting a constant velocity (i.e., the DDS velocity νDDS) from the velocity profile. DDS exploits the simple fact that the optically up-converted data ride on top of a base velocity (ν0, the apparent velocity at no motion) with a rapid rise to a high velocity (νf) of a few km/s or more. Consequently, the frequency content of the signal must describe a velocity profile that increases from ν0 to ν0 + νf. The DDS technique produces velocity reversals in the processed data before shock breakout when ν0 < νDDS < ν0 + νf. The DDS analysis process strategically selects specific DDS velocities (velocity at which the user down shifts the data) that produce anomalous reversals (maxima and/or minima), which are predictable and easy to identify in the mid-range of the data. Additional analysis determines when these maxima and minima occur. By successive application of the DDS technique and iterative analysis, velocity profiles are extracted as time as a function of velocity rather than as a function of time as it would be in a conventional velocity profile. Presented results include a description of DDS, velocity profiles extracted from laser-driven shock data with rise times of 200 ps or less, and a comparison with other techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Property Evaluation of CuNb Composites Manufactured with High-Pressure Torsion

Copper is under consideration as the optimum material for both high heat flux applications and high pulsed magnets. One challenge is that copper has low strength which is problematic to deployment in these applications. One solution is to alloy copper with BCC elements to improve its mechanical properties. However, the limited solubility of the BCC elements in copper requires high deformation processes to be used in order to manufacture these 3D composites. Here, high energy ball milling combined with high pressure torsion was used to manufacture 3D Cu-Nb composites. After the consolidation the mechanical properties of the composites were measured using micro- and nanohardness testing at room and elevated temperature. The results indicated that after 10 turns during the high-pressure torsion consolidation, the mechanical properties of the composites were completely saturated displaying uniform properties across the manufactured disk. Performing the high pressure torsion at temperature further improved consolidation of the disk. The high temperature nanoindentation also indicated a change in the deformation mechanism between 200 and 500 ºC.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Effective Purification Process for the Nuclear Radiation Detector Tl 6 SeI 4

The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6Se4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TU. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 10(11) Omega.cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV gamma-ray from Co-57 radiation source. The electron mobility-lifetime product mu(e)tau(e) for TI6SeI4 detector is 8.1 X 10(-5) cm(2).V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV alpha-particles from Am-241, the electron and hole mobilities were estimated to be 112 +/- 22 and 81 +/- 16 cm(2).V-1.s(-1), respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

Lin, Wenwen (ORCID:0000000216279558)↗

Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se

Purpose: The authors describe a detailed Monte Carlo (MC) method for the coupled transport of ionizing particles and charge carriers in amorphous selenium (a-Se) semiconductor x-ray detectors, and model the effect of statistical variations on the detected signal. Methods: A detailed transport code was developed for modeling the signal formation process in semiconductor x-ray detectors. The charge transport routines include three-dimensional spatial and temporal models of electron-hole pair transport taking into account recombination and trapping. Many electron-hole pairs are created simultaneously in bursts from energy deposition events. Carrier transport processes include drift due to external field and Coulombic interactions, and diffusion due to Brownian motion. Results: Pulse-height spectra (PHS) have been simulated with different transport conditions for a range of monoenergetic incident x-ray energies and mammography radiation beam qualities. Two methods for calculating Swank factors from simulated PHS are shown, one using the entire PHS distribution, and the other using the photopeak. The latter ignores contributions from Compton scattering and K-fluorescence. Comparisons differ by approximately 2% between experimental measurements and simulations. Conclusions: The a-Se x-ray detector PHS responses simulated in this work include three-dimensional spatial and temporal transport of electron-hole pairs. These PHS were used to calculate the Swank factor and compare it with experimental measurements. The Swank factor was shown to be a function of x-ray energy and applied electric field. Trapping and recombination models are all shown to affect the Swank factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Architecture and Implementation of OpenPET Firmware and Embedded Software

OpenPET is an open source, modular, extendible, and high-performance platform suitable for multi-channel data acquisition and analysis. Due to the versatility of the hardware, firmware, and software architectures, the platform is capable of interfacing with a wide variety of detector modules not only in medical imaging but also in homeland security applications. Analog signals from radiation detectors share similar characteristics-a pulse whose area is proportional to the deposited energy and whose leading edge is used to extract a timing signal. As a result, a generic design method of the platform is adopted for the hardware, firmware, and software architectures and implementations. The analog front-end is hosted on a module called a Detector Board, where each board can filter, combine, timestamp, and process multiple channels independently. The processed data is formatted and sent through a backplane bus to a module called Support Board, where 1 Support Board can host up to eight Detector Board modules. The data in the Support Board, coming from 8 Detector Board modules, can be aggregated or correlated (if needed) depending on the algorithm implemented or runtime mode selected. It is then sent out to a computer workstation for further processing. The number of channels (detector modules), to be processed, mandates the overall OpenPET System Configuration, which is designed to handle up to 1,024 channels using 16-channel Detector Boards in the Standard System Configuration and 16,384 channels using 32-channel Detector Boards in the Large System Configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnosis of high-intensity pulsed heavy ion beam generated by a novel magnetically insulated diode with gas puff plasma gun

Intense pulsed heavy ion beam is expected to be applied to materials processing including surface modification and ion implantation. For those applications, it is very important to generate high-purity ion beams with various ion species. For this purpose, we have developed a new type of a magnetically insulated ion diode with an active ion source of a gas puff plasma gun. When the ion diode was operated at a diode voltage of about 190 kV, a diode current of about 15 kA, and a pulse duration of about 100 ns, the ion beam with an ion current density of 54 A/cm{sup 2} was obtained at 50 mm downstream from the anode. By evaluating the ion species and the energy spectrum of the ion beam via a Thomson parabola spectrometer, it was confirmed that the ion beam consists of nitrogen ions (N{sup +} and N{sup 2+}) of energy of 100-400 keV and the proton impurities of energy of 90-200 keV. The purity of the beam was evaluated to be 94%. The high-purity pulsed nitrogen ion beam was successfully obtained by the developed ion diode system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Pulse Width Dependence and Ionization Mechanism of Matrix-Assisted Laser Desorption/Ionization

Ultraviolet laser pulses at 355 nm with variable pulse widths in the region from 170 ps to 1.5 ns were used to investigate the ionization mechanism of matrix-assisted laser desorption/ionization (MALDI) for matrices 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and sinapinic acid (SA). The mass spectra of desorbed ions and the intensity and velocity distribution of desorbed neutrals were measured simultaneously for each laser shot. These quantities were found to be independent of the laser pulse width. A comparison of the experimental measurements and numerical simulations according to the multiphoton ionization, coupled photophysical and chemical dynamics (CPCD), and thermally induced proton transfer models showed that the predictions of thermally induced proton transfer model were in agreement with the experimental data, but those of the multiphoton ionization model were not. Moreover, the predictions of the CPCD model based on singlet–singlet energy pooling were inconsistent with the experimental data of CHCA and SA, but were consistent with the experimental data of DHB only when some parameters used in the model were adjusted to extreme values. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon counting imaging with an electron-bombarded CCD: Towards a parallel-processing photoelectronic time-to-amplitude converter

We have used an electron-bombarded CCD for optical photon counting imaging. The photon event pulse height distribution was found to be linearly dependent on the gain voltage. We propose on this basis that a gain voltage sweep during exposure in an electron-bombarded sensor would allow photon arrival time determination with sub-frame exposure time resolution. This effectively uses an electron-bombarded sensor as a parallel-processing photoelectronic time-to-amplitude converter, or a two-dimensional photon counting streak camera. Several applications that require timing of photon arrival, including Fluorescence Lifetime Imaging Microscopy, may benefit from such an approach. A simulation of a voltage sweep performed with experimental data collected with different acceleration voltages validates the principle of this approach. Moreover, photon event centroiding was performed and a hybrid 50% Gaussian/Centre of Gravity + 50% Hyperbolic cosine centroiding algorithm was found to yield the lowest fixed pattern noise. Finally, the camera was mounted on a fluorescence microscope to image F-actin filaments stained with the fluorescent dye Alexa 488 in fixed cells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on the dynamic holdup distribution of the pulsed extraction column

In the study, a CSTR cascade dynamic hydraulic model was developed to investigate the dynamic holdup distribution of the pulsed extraction column. It is assumed that the dynamic process of the dispersed phase holdup of pulsed extraction column has equal effects with the operational process of multiple cascade CSTRs. The process is consistent with the following assumptions: the holdups vary on different stages but maintain uniform on each stage; the changes of the hydraulic parameters have impact initially on the inlet of dispersed phase, and stability will be reached gradually through stage-by-stage blending. The model was tested and verified utilizing time domain response curves of the average holdup. Nearly 150 experiments were carried out with different capillary columns, various feed liquids, and diverse continuous phases and under different operation conditions. The regression curves developed by the model show a good consistency with the experimental results. After linking parameters of the model with operational conditions, the study further found that the parameters are only linearly correlated with pulse conditions and have nothing to do with flow rate for a specific pulsed extraction column. The accuracy of the model is measured by the average holdup, and the absolute error is ±0.01. The model can provide supports for the boundary studies on hydraulics and mass transfer by making simple and reliable prediction of the dynamic holdup distribution, with relatively less accessible hydraulic experimental data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of a co-micronized composite containing palmitoylethanolamide and polydatin in an experimental model of benign prostatic hyperplasia

Palmitoylethanolamide (PEA), a fatty acid amide-signaling molecule has well-known anti-inflammatory and neuroprotective effects. Nevertheless, PEA does not possess the ability to prevent free radicals formation. Polydatin (PLD), a biological precursor of resveratrol, has antioxidant activity. A combination of PEA and PLD could, conceivably, have beneficial effects on oxidative stress produced by inflammatory processes. In the present study we investigated the effects of a co-micronized composite containing PEA and PLD (m(PEA/PLD)) in a model of testosterone-induced benign hyperplasia (BPH). BPH was provoked in rats by daily administration of testosterone propionate (3 mg/kg) for 14 days. This protocol leads to alterations in prostate morphology and increased levels of prostaglandin E2 and dihydrotestosterone as well as of 5α-reductase 1 and 5α-reductase 2 expression. Moreover, testosterone induced marked inflammation in terms of an increase in nuclear translocation of nuclear factor-κB p65 and consequently in IκB-α degradation as well as disregulation of inducible nitric oxide synthase, cyclooxygenase-2 and manganese superoxide dismutase expression and in the apoptosis pathway. Our results show, for the first time, that m(PEA/PLD) is capable of decreasing prostate weight and dihydrotestosterone production in BPH-induced rats. These effects were most likely correlated to the anti-inflammatory and apoptotic effects of m(PEA/PLD). Accordingly, these results support the view that m(PEA/PLD) should be further studied as a potent candidate for the management of BPH. - Highlights: • Chronic inflammation has emerged as a potential factor in the pathogenesis of BPH. • We evaluate the effects of m(PEA/PLD) in terms of impact on the inflammatory process and oxidative stress in BPH. • m(PEA/PLD) should be further explored as a valid candidate for the treatment of BPH.

60 APPLIED LIFE SCIENCES↗

SHINE and Mini-SHINE Column Designs for Recovery of Mo from 140 g-U/L Uranyl Sulfate

Argonne is assisting SHINE Medical Technologies (SHINE) in their efforts to develop an accelerator-driven process that utilizes a uranyl-sulfate solution for the production of fission Mo-99. In an effort to design a Mo-recovery system for the SHINE project using low-enriched uranium (LEU), we conducted batch, breakthrough, and pulse tests to determine the Mo isotherm, mass-transfer zone (MTZ), and system parameters for a 130 g-U/L uranyl sulfate solution at pH 1 and 80°C, as described previously. The VERSE program was utilized to calculate the MTZ under various loading times and velocities. The results were then used to design Mo separation and recovery columns employing a pure titania sorbent (110-μm particles, S110, and 60 Å pore size). The plant-scale column designs assume Mo will be separated from 271 L of a 141 g-U/L uranyl sulfate solution, pH 1, containing 0.0023 mM Mo. The VERSE-designed recovery systems have been tested and verified in laboratory-scale experiments, and this approach was found to be very successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nano-Engineering of Detector Surfaces to Offer Unprecedented Imager Sensitivity to Soft X-rays and Low Energy Electrons

The focus of this document is to record the learning and process development achieved by the completion of the Nano-Engineering of Detector Surfaces to Offer Unprecedented Imager Sensitivity to Soft X-rays and Low Energy Electrons LDRD. The goal of this effort was to study different silicon detector surface preparation methods such as ion implant parameters, and the addition of a quantum 2-layer superlattice. Enabling the preparation of the surface of silicon detectors (front side illuminated or bonded backside illuminated) increases the responsivity of the diode to shallowly absorbed photons. This increased sensitivity in turn allows for greater fidelity in imaging events that emit low soft X-rays or low energy electrons. Prior work has focused on passivating the surface of a silicon detectors with thin layers (tens of nm thick) of materials to reduce surface recombination sites. Measurements of visible light quantum efficiency, electron responsivity, and pulsed x-ray response indicate that detectors with a 2- layer superlattice enjoy a significant benefit over equivalent detectors using an ion implant at the illuminated surface.

42 ENGINEERING↗

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗