Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Alignment Test Results of the JWST Pathfinder Telescope Mirrors in the Cryogenic Environment

After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASAs Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the SI detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.

OTIS↗

Alignment Test Results of the JWST Pathfinder Telescope Mirrors in the Cryogenic Environment

After integration of the Optical Telescope Element (OTE) to the Integrated Science Instrument Module (ISIM) to become the OTIS, the James Webb Space Telescope OTIS is tested at NASAs Johnson Space Center (JSC) in the cryogenic vacuum Chamber A for alignment and optical performance. The alignment of the mirrors comprises a sequence of steps as follows: The mirrors are coarsely aligned using photogrammetry cameras with reflective targets attached to the sides of the mirrors. Then a multi-wavelength interferometer is aligned to the 18-segment primary mirror using cameras at the center of curvature to align reflected light from the segments and using fiducials at the edge of the primary mirror. Once the interferometer is aligned, the 18 primary mirror segments are then adjusted to optimize wavefront error of the aggregate mirror. This process phases the piston and tilt positions of all the mirror segments. An optical fiber placed at the Cassegrain focus of the telescope then emits light towards the secondary mirror to create a collimated beam emitting from the primary mirror. Portions of the collimated beam are retro-reflected from flat mirrors at the top of the chamber to pass through the telescope to the SI detector. The image on the detector is used for fine alignment of the secondary mirror and a check of the primary mirror alignment using many of the same analysis techniques used in the on-orbit alignment. The entire process was practiced and evaluated in 2015 at cryogenic temperature with the Pathfinder telescope.

Interferometer↗

Violations of a new inequality for classical fields

Two entangled photons incident upon two distant interferometers can give a coincidence counting rate that depends nonlocally on the sum of the phases of the two interferometers. It has recently been shown that experiments of this kind may violate a simple inequality that must be satisfied by any classical or semi-classical field theory. The inequality provides a graphic illustration of the lack of objective realism of the electric field. The results of a recent experiment which violates this inequality and in which the optical path length between the two interferometers was greater than 100 m are briefly described.

Franson, J. D.↗

Laser-assisted embedding of all-glass optical fiber sensors into bulk ceramics for high-temperature applications

We develop a laser-assisted sensor embedding process to embed all-glass optical fiber sensors into bulk ceramics for high-temperature applications. A specially designed two-step microchannel was fabricated on an Al 2 O 3 substrate for sensor embedment using a picosecond (ps) laser. An optical fiber Intrinsic Fabry-Perot Interferometer (IFPI) sensor was embedded at the bottom of the microchannel and covered by Al 2 O 3 slurry which was subsequently sintered by a CO 2 laser. The sensor spectrum was in-situ monitored during the laser sintering process to ensure the survival of the sensor and optimize the laser sintering parameters. By testing in furnace through high temperature, the embedded optical fiber shows improved stability after CO 2 laser sealing, resulting in the linear temperature response of the embedded optical fiber IFPI sensor. To improve the embedded IFPI sensor for thermal strain measurement, a dummy fiber was co-embedded with the sensing fiber to improve the mechanical bonding between the sensing fiber and the ceramic substrate so that the thermal strain of the ceramic substrate can apply on the sensing fiber. The response sensitivity, measurement repeatability and high-temperature long-term stability of the embedded optical fiber IFPI sensor were evaluated in this work.

47 OTHER INSTRUMENTATION↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time-pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

Femtosecond Photon-Counting Receiver

An optical correlation receiver is described that provides ultra-precise distance and/or time/pulse-width measurements even for weak (single photons) and short (femtosecond) optical signals. A new type of optical correlation receiver uses a fourth-order (intensity) interferometer to provide micron distance measurements even for weak (single photons) and short (femtosecond) optical signals. The optical correlator uses a low-noise-integrating detector that can resolve photon number. The correlation (range as a function of path delay) is calculated from the variance of the photon number of the difference of the optical signals on the two detectors. Our preliminary proof-of principle data (using a short-pulse diode laser transmitter) demonstrates tens of microns precision.

Photons↗

FUNDAMENTAL PERFORMANCE OF A DISPERSED FIXED DELAY INTERFEROMETER IN SEARCHING FOR PLANETS AROUND M DWARFS

We present a new method to calculate fundamental Doppler measurement limits with a dispersed fixed delay interferometer (DFDI) in the near-infrared (NIR) wavelength region for searching for exoplanets around M dwarfs in the coming decade. It is based on calculating the Q factor, a measure of flux-normalized Doppler sensitivity in the fringing spectra created with DFDI. We calculate the Q factor as a function of spectral resolution R, stellar-projected rotational velocity Vsin i, stellar effective temperature T{sub eff}, and optical path difference (OPD) of the interferometer. We also compare the DFDI Q factor to that for the popular cross-dispersed echelle spectrograph method (the direct echelle (DE) method). We find that (1) Q{sub DFDI} is a factor of 1.5-3 higher than Q{sub DE} at R ranging from 5000 to 20,000; (2) Q{sub DFDI} and Q{sub DE} converge at a very high R (R {>=} 100,000); (3) Q{sub DFDI} increases as R increases and Vsin i deceases; (4) for a given R, Q{sub DFDI} increases as T{sub eff} drops from 3100 K to 2400 K (M4V to M9V). We also investigate how Q{sub DFDI} is affected by OPD and find that a 5 mm deviation from the optimal OPD does not significantly affect Q{sub DFDI} (10% or less) for a wide range of R. Given that the NIR Doppler measurement is likely to be detector-limited for a while, we introduce new merit functions, which is directly related to photon-limited radial velocity (RV) uncertainty, to evaluate Doppler performance with the DFDI and DE methods. We find that DFDI has strength in wavelength coverage and multi-object capability over the DE for a limited detector resource. We simulate the performance of the InfraRed Exoplanet Tracker (IRET) based on the DFDI design, being considered for the next generation IR Doppler measurements. The predicted photon-limited RV uncertainty suggests that IRET is capable of detecting Earth-like exoplanets in habitable zone around nearby bright M dwarfs if they exist. A new method is developed to quantitatively estimate the influence of telluric lines on RV uncertainty. Our study shows that photon-limited RV uncertainty can be reached if 99% of the strength of telluric lines can be removed from the measured stellar spectra. At low to moderate levels of telluric line strength removal (50%-90%), the optimal RV uncertainty is typically a factor of two to three times larger than photon-limited RV uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication of the Advanced X-ray Astrophysics Facility (AXAF) Optics: A Deterministic, Precision Engineering Approach to Optical Fabrication

The mirror assembly of the AXAF observatory consists of four concentric, confocal, Wolter type 1 telescopes. Each telescope includes two conical grazing incidence mirrors, a paraboloid followed by a hyperboloid. Fabrication of these state-or-the-art optics is now complete, with predicted performance that surpasses the goals of the program. The fabrication of these optics, whose size and requirements exceed those of any previous x-ray mirrors, presented a challenging task requiring the use of precision engineering in many different forms. Virtually all of the equipment used for this effort required precision engineering. Accurate metrology required deterministic support of the mirrors in order to model the gravity distortions which will not be present on orbit. The primary axial instrument, known as the Precision Metrology Station (PMS), was a unique scanning Fizeau interferometer. After metrology was complete, the optics were placed in specially designed Glass Support Fixtures (GSF's) for installation on the Automated Cylindrical Grinder/Polishers (ACG/P's). The GSF's were custom molded for each mirror element to match the shape of the outer surface to minimize distortions of the inner surface. The final performance of the telescope is expected to far exceed the original goals and expectations of the program.

Gordon, T. E.↗

Atom Interferometers with Scalable Enclosed Area

Bloch oscillations (i.e., coherent acceleration of matter waves by an optical lattice) and Bragg diffraction are integrated into light-pulse atom interferometers with large momentum splitting between the interferometer arms, and hence enhanced sensitivity. Simultaneous acceleration of both arms in the same internal states suppresses systematic effects, and simultaneously running a pair of interferometers suppresses the effect of vibrations. Ramsey-Borde interferometers using four such Bloch-Bragg-Bloch beam splitters exhibit 15% contrast at 24(Planck constant/2pi)k splitting, the largest so far ((Planck constant/2pi)k is the photon momentum); single beam splitters achieve 88(Planck constant/2pi)k. The prospects for reaching 100 s of (Planck constant/2pi)k and applications such as gravitational wave sensors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of a space-station-associated multiple spacecraft Michelson spatial interferometer

One approach to Michelson spatial interferometry at optical wavelengths involves use of an array of spacecraft in which two widely-separated telescopes collect light from a star and direct it to a third, centrally-located, device which combines the beams in order to detect and measure interference fringes. The original version of a spacecraft array for Michelson spatial interferometry (SAMSI) was modified so that the system uses the fuel resupply capability of a space station. The combination of this fuel resupply capability with a method of obtaining image Fourier transform phase information, necessary for full image reconstruction, permits SAMSI to be used to synthesize images equivalent to those produced by huge apertures in space. Synthesis of apertures in the 100 to 500 meter range is discussed. Reconstruction can be performed to a visual magnitude of at least 8 for a 100 A passband in 9 hours. Data are simultaneously collected for image generation from 0.1 micron to 18 microns. In the one-dimensional mode, measurements can be made every 90 minutes (including acquisition and repointing time) for objects as faint as 19th magnitude in the visible.

Stachnik, R. V.↗

The Hawaii Imaging Fabry-Perot Interferometer (HIFI)

At Mauna Kea Observatory, researchers conducted optical, imaging spectrophotometric studies of selected active galaxies using both the Canada-France-Hawaii 3.6m and University of Hawaii 2.2m telecopes (Tully, Bland and Cecil 1988). To maximize spatial resolution, researchers select galaxies independent of luminosity but known to possess interesting morphologies or high-velocity, extranuclear ionized gas (Walker 1968; Rubin and Ford 1968). They study both the large-scale patterns produced in IR-luminous, starburst systems (e.g., M82, NGC 253, NGC 6240) and those with compact, but spatially extended, circumnuclear, narrow line regions (e.g., M51, NGC 1068, NGC 4151). Current studies are restricted to the optical (SII), (NII) and (OIII) lines and the brightest Balmer recombination lines. These lines are, in principle, sufficient to constrain the dynamical structure and dominant excitation mechanism of the ionized component.

Bland, Jonathan↗

Influence of intensity loss in the cavity of a folded Fabry-Perot interferometer on interferometric signals

Fabry-Perot interferometer is often used for the micro-displacement, because of its common optical path structure being insensitive to the environmental disturbances. Recently, the folded Fabry-Perot interferometer has been investigated for displacement measurements in large ranges. The advantages of a folded Fabry-Perot interferometer are insensitive to the tilt angle and higher optical resolution. But the design of the optical cavity has become more and more complicated. For this reason, the intensity loss in the cavity will be an important parameter for the distribution of the interferometric intensity. To obtain a more accurate result of such interferometer utilized for displacement measurements, the intensity loss of the cavity in the fabricated folded Fabry-Perot interferometer and the modified equation of the folded Fabry-Perot interferometer will be described. According to the theoretical and experimental results, the presented model is available for the analysis of displacement measurements by a folded Fabry-Perot interferometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collinear interferometer with variable delay for carrier-envelope offset frequency measurement

We demonstrate a novel scheme for measuring the carrier-envelope offset frequency in a femtosecond optical frequency comb. Our method is based on a common-path interferometer with a calcite Babinet-Soleil compensator employed to control the delay between the two interfering beams of pulses. The large delay range (up to 8 ps) of our device is sufficient for systems that rely on spectral broadening in microstructured fibers. We show an experimental proof that the stability of a common-path arrangement is superior to that of the standard interferometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-mode fiber, velocity interferometry

In this paper, we describe a velocity interferometer system based entirely on single-mode fiber optics. This paper includes a description of principles used in developing the single-mode velocity interferometry system (SMV). The SMV design is based on polarization-insensitive components. Polarization adjusters are included to eliminate the effects of residual birefringence and polarization dependent losses in the interferometers. Characterization measurements and calibration methods needed for data analysis and a method of data analysis are described. Calibration is performed directly using tunable lasers. During development, we demonstrated its operation using exploding-foil bridge-wire fliers up to 200 m/s. In a final test, we demonstrated the SMV in a gas gun experiment up to 1.2 km/sec. As a basis for comparison in the gas gun experiment, we used another velocimetry technique that is also based on single-mode fiber optics: photonic Doppler velocimetry (PDV). For the gas gun experiment, we split the light returned from a single target spot and performed a direct comparison of the homodyne (SMV) and heterodyne (PDV) techniques concurrently. The two techniques had a negligible mean difference and a 1.5% standard deviation in the one-dimensional shock zone. Within one interferometer delay time after a sudden Doppler shift, a SMV unencumbered by multimode-fiber dispersion exhibits two color beats. These beats have the same period as PDV beats--this interference occurs between the ''recently'' shifted and ''formerly unshifted'' paths within the interferometer. We believe that recognizing this identity between homodyne and heterodyne beats is novel in the shock-physics field. SMV includes the conveniences of optical fiber, while removing the time resolution limitations associated with the multimode delivery fiber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of infinite and wedge fringe settings in Mach Zehnder interferometer for temperature field measurement

Interferometric method, which utilizes the interference of coherent light beams, is used to determine the temperature distribution in the vicinity of a vertical heater plate. The optical components are arranged so as to obtain wedge fringe and infinite fringe patterns and isotherms obtained in each case were compared. In wedge fringe setting, image processing techniques has been used for obtaining isotherms by digital subtraction of initial parallel fringe pattern from deformed fringe pattern. The experimental results obtained are compared with theoretical correlations. The merits and demerits of the fringe analysis techniques are discussed on the basis of the experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High sensitivity laser interferometry for detection of boundary-layer transition

A high sensitivity laser interferometry for continuous monitoring of optical path changes is presented. The sensitivity to small changes in the optical path is achieved by means of a feedback system which keeps the interferometer at its maximum (and linear) position. Two experiments were designed to verify the interferometer's performance, both in direct and in scattering configurations. In each case, small temperature fluctuations were introduced as the signal source. Simultaneous measurement of temperature were compared with the results of the interferometer. Good correlation between the results were obtained. Finally, the application of the high sensitivity interferometer for detection of boundary-layer transition is examined. Optical signal strength and possible sources of noise are examined. Some methods of model surface preparation for enhancement of signal-to-noise ratio are discussed.

Modarress, D.↗