Search NASA⌕ Search

SEARCH · Search NASA

Results for “program verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Historic American engineering record. Nevada national security site, Bren Tower Complex. Written historical and descriptive data and field records

The BREN (Bare Reactor Experiment, Nevada) Tower Complex is significant for its role in the history of nuclear testing, radiation dosimetry studies, and early field testing of the Strategic Missile Defense System designs. At the time it was built in 1962, the 1,527 ft (465 m) BREN Tower was the tallest structure west of the Mississippi River and exceeded the height of the Empire State Building by 55 ft (17 m). It remains the tallest ever erected specifically for scientific purposes and was designed and built to facilitate the experimental dosimetry studies necessary for the development of accurate radiation dose rates for the survivors of Hiroshima and Nagasaki. The tower was a key component of the Atomic Bomb Casualty Commission’s (ABCC) mission to predict the health effects of radiation exposure. Moved to its current location in 1966, the crucial dosimetry studies continued with Operation HENRE (High Energy Neutron Reactions Experiment). These experiments and the data they generated became the basis for a dosimetry system called the Tentative 1965 Dose or more commonly the T65D model. Used to estimate radiation doses received by individuals, the T65D model was applied until the mid-1980s when it was replaced by a new dosimetry system known as DS86 based on the Monte Carlo method of dose rate calculation. However, the BREN Tower data are still used for verification of the validity of the DS86 model. In addition to its importance in radiation heath effects research, the BREN Tower Complex is also significant for its role in the Brilliant Pebbles research project, a major component of the Strategic Defense Initiative popularly known as the “Star Wars” Initiative. Instigated under the Reagan Administration, the program’s purpose was to develop a system to shield the United States and allies from a ballistic missile attack. The centerpiece of the Strategic Defense System was space-based, kinetic-kill vehicles. In 1991, BREN Tower was used for the tether tests of the Brilliant Pebbles prototype vehicle at the earth’s surface prior to the more costly space testing program. The success of these tests established the Brilliant Pebbles program as an essential component of America’s space-based missile defense system even after the dismantling of the Soviet Union. Data from the Brilliant Pebbles research program continues to inspire current missile defense system research (Independent Working Group 2009).

54 ENVIRONMENTAL SCIENCES↗

Core Design of the Holos-Quad Microreactor

The Holos-Quad micro-reactor concept, developed by HolosGen LLC, is equipped with a 22 MWt (Mega-Watt thermal) core and an integral power conversion system converting the core thermal energy into approximately 10 MWe (Mega-Watt electric). This design can be configured to support a wide range of applications. It is a very innovative high-temperature gas-cooled reactor concept using TRI-structural ISOtropic particle fuel (TRISO) distributed in graphite hexagonal blocks, cooled with helium in a direct Brayton cycle independently executed by four Subcritical Power Modules (SPMs) fitted into a hardened 40-foot container whose dimensions are in compliance with ISO shipping containers requirements. In FY2019 HolosGen LLC was awarded by the Department of Energy Advanced Research Project Agency-Energy (DOE ARPA-E) under the MEITNER funding program. As part of the MEITNER award, the Argonne National Laboratory (ANL) contributed expertise through two specialized teams: The “Design Team” and the “Resource Team”. The Design Team was dedicated to validate feasibility of the Holos-Quad core and to optimize its core design through neutronics analyses. The Resource Team was dedicated to feasibility verification via high-fidelity codes of Holos-Quad thermal-hydraulic, heat transfer, shielding, and structural aspects. This report summarizes the activities conducted by ANL Design Team. A rigorous design approach based on multi-criteria optimization and code-to-code comparison involving stochastic and high-fidelity deterministic solutions was developed and employed at several evolutionary stages of the Holos-Quad design. Several generations of the Holos-Quad core were designed within this project before converging to the current full-scale Gen 2+ design that is detailed in this report. Figure EA-1 illustrates a cross-sectional view of Gen 2+ Holos-Quad core configuration, and Figure EA-2 provides a simplified perspective view of 1-of-4 SPMs. The Holos-Quad uses four thermal-hydraulically independent SPMs locked into stationary positions during power operation, surrounded by BeO reflector and structural component fully comprised within the dimensional constraints represented by traditional ISO containers. One of the benefits of this approach is to enable transportation of each SPM promptly after irradiation in shielded containers. The core is designed to operate for approximately 8 full-power years while the reactivity controls and power conversion system enable load-following operations. The reactivity controls are represented by independent, diversified, and redundant reactivity control systems based on control drums and redundant sets of shutdown rods. The high-fidelity simulation tools were used to assess detailed power and flux distributions of the three-dimensional full-core or quarter-core of the Gen 2+ configuration. Single-physics and multi-physics simulations of the neutronics code PROTEUS and the thermal-hydraulic code System Analysis Module (SAM) were performed to analyze the Holos design configurations with detailed high-fidelity solutions. The design work performed confirmed feasibility of the Holos-Quad concept, provided realistic design description for detailed design of the operational system, and identified several core design improvements to be further considered for future reactor development activities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Integral-based Technique to Accelerate the Monte Carlo Radiative Transfer Computation for Supernovae

We present an integral-based technique (IBT) algorithm to accelerate supernova (SN) radiative transfer calculations. The algorithm utilizes “integral packets,” which are calculated by the path integral of the Monte Carlo (MC) energy packets, to synthesize the observed spectropolarimetric signal at a given viewing direction in a 3D time-dependent radiative transfer program. Compared to the event-based technique (EBT) proposed by M. Bulla et al., our algorithm significantly reduces the computation time and increases the MC signal-to-noise ratio (S/N). Using a 1D spherical symmetric Type Ia SN ejecta model DDC10 and its derived 3D model, the IBT algorithm has successfully passed the verification of spherical symmetry and cross comparison on a 3D SN model with the direct-counting technique and EBT. Notably, with our algorithm implemented in the 3D MC radiative transfer code SEDONA, the computation time is faster than EBT by a factor of 10−30, and the S/N is better by a factor of 1.5−3, with the same number of MC quanta.

79 ASTRONOMY AND ASTROPHYSICS↗

A Robust and Flexible Design for GCEP Unattended Online Enrichment Monitoring: An OLEM Collection Node Network

Oak Ridge National Laoratory (ORNL) has engineered an on-line enrichment monitor (OLEM) to continuously measure U-235 emissions from the UF6 gas flowing through a unit header pipe of a gas centrifuge enrichment plant (GCEP) as a component of the International Atomic Energy Agency s (IAEA) new generation of technology to support enrichment plant safeguards1. In contrast to other enrichment monitoring approaches, OLEM calibrates and corrects for the pressure and temperature dependent UF6 gas-density without external radiation sources by using the inherent unit header pipe pressure dynamics and combining U-235 gamma-ray spectrometery using a shielded NaI detector with gas pressure and temperature data near the spectrum measurement point to obtain the enrichment of the gas as a function of time. From a safeguards perspective, OLEM can provide early detection of a GCEP being misused for production of highly enriched uranium, but would not detect directly the isolation and use of a cascade within the production unit to produce HEU. OLEM may also reduce the number of samples collected for destructive assay and, if coupled with load cell monitoring, could support isotope mass balance verification and unattended cylinder verification. The earlier paper presented OLEM as one component along with shared load cells and unattended cylinder verification, in the IAEA emering toolbox for unattended instruments at GCEPs1 and described the OLEM concept and how previous modeling studies and field measurements helped confirm the viability of a passive on-line enrichment monitor for meeting IAEA objectives and to support the development of performance targets. Phase I of the United States Support Program (USSP) OLEM project completed a preliminary hardware, software and communications design; phase II will build and test field prototypes in controlled laboratory settings and then at an operational facility. That paper also discussed many of the OLEM collection node commercial off the shelf (COTS) components and summarized the OLEM collection node data security provisions. This paper will discuss a secure and redundant network of OLEM collection nodes, auxiliary detection units and supporting junction boxes distributed throughout a facility for monitoring enrichment on product, feed and tails unit header pipes; the purpose and capability of the built-in Electronic Optical Sealing System (EOSS) network gateway; and a network approach for obtaining reliable and authenticated pressure measurements.

Younkin, James R↗

Southwestern Regional Partnership For Carbon Sequestration (Phase 2) Pump Canyon CO2- ECBM/Sequestration Demonstration, San Juan Basin, New Mexico

Within the Southwest Regional Partnership on Carbon Sequestration (SWP), three demonstrations of geologic CO{sub 2} sequestration are being performed -- one in an oilfield (the SACROC Unit in the Permian basin of west Texas), one in a deep, unmineable coalbed (the Pump Canyon site in the San Juan basin of northern New Mexico), and one in a deep, saline reservoir (underlying the Aneth oilfield in the Paradox basin of southeast Utah). The Pump Canyon CO{sub 2}-enhanced coalbed methane (CO{sub 2}/ECBM) sequestration demonstration project plans to demonstrate the effectiveness of CO{sub 2} sequestration in deep, unmineable coal seams via a small-scale geologic sequestration project. The site is located in San Juan County, northern New Mexico, just within the limits of the high-permeability fairway of prolific coalbed methane production. The study area for the SWP project consists of 31 coalbed methane production wells located in a nine section area. CO{sub 2} was injected continuously for a year and different monitoring, verification and accounting (MVA) techniques were implemented to track the CO{sub 2} movement inside and outside the reservoir. Some of the MVA methods include continuous measurement of injection volumes, pressures and temperatures within the injection well, coalbed methane production rates, pressures and gas compositions collected at the offset production wells, and tracers in the injected CO{sub 2}. In addition, time-lapse vertical seismic profiling (VSP), surface tiltmeter arrays, a series of shallow monitoring wells with a regular fluid sampling program, surface measurements of soil composition, CO{sub 2} fluxes, and tracers were used to help in tracking the injected CO{sub 2}. Finally, a detailed reservoir model was constructed to help reproduce and understand the behavior of the reservoir under production and injection operation. This report summarizes the different phases of the project, from permitting through site closure, and gives the results of the different MVA techniques.

01 COAL, LIGNITE, AND PEAT↗

FY17 ISCR Scholar End-of-Assignment Report - Robbie Sadre

Throughout this internship assignment, I did various tasks that contributed towards the starting of the SASEDS (Safe Active Scanning for Energy Delivery Systems) and CES-21 (California Energy Systems for the 21st Century) projects in the SKYFALL laboratory. The goal of the SKYFALL laboratory is to perform modeling and simulation verification of transmission power system devices, while integrating with high-performance computing. The first thing I needed to do was acquire official Online LabVIEW training from National Instruments. Through these online tutorial modules, I learned the basics of LabVIEW, gaining experience in connecting to NI devices through the DAQmx API as well as LabVIEW basic programming techniques (structures, loops, state machines, front panel GUI design etc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

NONDESTRUCTIVE EXAMINATION OF PLUTONIUM-BEARING MATERIAL CONTAINERS

The first nondestructive examination (NDE) of 3013-type containers as part of the Department of Energy's (DOE's) Integrated Surveillance Program (ISP) was performed in February, 2005. Since that date 280 NDE surveillances on 255 containers have been conducted. These containers were packaged with plutonium-bearing materials at multiple DOE sites. The NDE surveillances were conducted at Hanford, Lawrence Livermore National Laboratory (LLNL), and Savannah River Site (SRS). These NDEs consisted of visual inspection, mass verification, radiological surveys, prompt gamma analysis, and radiography. The primary purpose of performing NDE surveillances is to determine if there has been a significant pressure buildup inside the inner 3013 container. This is done by measuring the lid deflection of the inner 3013 container using radiography images. These lid deflection measurements are converted to pressure measurements to determine if a container has a pressure of a 100 psig or greater. Making this determination is required by Surveillance and Monitoring Plan (S&MP). All 3013 containers are designed to withstand at least 699 psig as specified by DOE-STD-3013. To date, all containers evaluated have pressures under 50 psig. In addition, the radiography is useful in evaluating the contents of the 3013 container as well as determining the condition of the walls of the inner 3013 container and the convenience containers. The radiography has shown no signs of degradation of any container, but has revealed two packaging anomalies. Quantitative pressure measurements based on lid deflections, which give more information than the 'less than or greater than 100 psig' (pass/fail) data are also available for many containers. Statistical analyses of the pass/fail data combined with analysis of the quantitative data show that it is extremely unlikely that any container in the population of 3013 containers considered in this study (e.g., containers packaged according to the DOE-STD-3013 by 2006) would exceed a pressure of 100 psig. At this time, Los Alamos National Laboratory (LANL) and LLNL continue to package containers. Future NDE surveillances will address containers packaged after 2006 for both sites as well as containers requested by the Materials Identification Surveillance (MIS) working group based on knowledge gained from shelf-life study and surveillance results.

42 ENGINEERING↗

The NRC's SPAR Models: Current Status, Future Development, and Modeling Issues

Probabilistic risk assessments (PRAs) play an increasingly important role in the regulatory framework of the U.S. nuclear power industry. The Nuclear Regulatory Commission (NRC) relies on a set of plant-specific Standardized Plant Analysis Risk (SPAR) models to provide critical risk-based input to the regulatory process. The Significance Determination Process (SDP), Management Directive 8.3 - NRC Incident Investigation Program, Accident Sequence Precursor (ASP) and Mitigating Systems Performance Index (MSPI) programs are among the regulatory initiatives that receive significant input from the SPAR models. Other uses of the SPAR models include: Screening & Resolution of Generic Safety Issues, License Amendment reviews and Notice of Enforcement Discretion (NOEDs). This paper presents the current status of SPAR model development activities, future development objectives, and issues related to the development, verification and maintenance of the SPAR models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from the whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP) (Grant No. 200900420)

60 APPLIED LIFE SCIENCES↗

Analysis of Validating and Verifying OpenACC Compilers 3.0 and Above

OpenACC is a high-level directive-based parallel programming model that can manage the sophistication of heterogeneity in architectures and abstract it from the users. The portability of the model across CPUs and accelerators has gained the model a wide variety of users. This means it is also crucial to analyze the reliability of the compilers’ implementations. To address this challenge, the OpenACC Validation and Verification team has proposed a validation testsuite to verify the OpenACC implementations across various compilers with an infrastructure for a more streamlined execution. This paper will cover the following aspects: (a) the new developments since the last publication on the testsuite, (b) outline the use of the infrastructure, (c) discuss tests that highlight our workflow process, (d) analyze the results from executing the testsuite on various systems, and (e) outline future developments.

Jarmusch, Aaron↗

SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

FY12 Quarter 3 Computing Utilization Report – LANL

DSW continues to dominate the capacity workload, with a focus in Q3 on common model baselining runs in preparation for the Annual Assessment Review (AAR) of the weapon systems. There remains unmet demand for higher fidelity simulations, and for increased throughput of simulations. Common model baselining activities would benefit from doubling the resolution of the models and running twice as many simulations. Capacity systems were also utilized during the quarter to prepare for upcoming Level 2 milestones. Other notable DSW activities include validation of new physics models and safety studies. The safety team used the capacity resources extensively for projects involving 3D computer simulations for the Furrow series of experiments at DARHT (a Level 2 milestone), fragment impact, surety theme, PANTEX assessments, and the 120-day study. With the more than tripling of classified capacity computing resources with the addition of the Luna system and the safety team's imminent access to the Cielo system, demand has been met for current needs. The safety team has performed successful scaling studies on Luna up to 16K PE size-jobs with linear scaling, running the large 3D simulations required for the analysis of Furrow. They will be investigating scaling studies on the Cielo system with the Lustre file system in Q4. Overall average capacity utilization was impacted by negative effects of the LANL Voluntary Separation Program (VSP) at the beginning of Q3, in which programmatic staffing was reduced by 6%, with further losses due to management backfills and attrition, resulting in about 10% fewer users. All classified systems were impacted in April by a planned 2 day red network outage. ASC capacity workload continues to focus on code development, regression testing, and verification and validation (V&V) studies. Significant capacity cycles were used in preparation for a JOWOG in May and several upcoming L2 milestones due in Q4. A network transition has been underway on the unclassified networks to increase access of all ASC users to the unclassified systems through the Yellow Turquoise Integration (YeTI) project. This will help to alleviate the longstanding shortage of resources for ASC unclassified code development and regression testing, and also make a broader palette of machines available to unclassified ASC users, including PSAAP Alliance users. The Moonlight system will be the first capacity resource to be made available through the YETI project, and will make available a significant increase in cycles, as well as GPGPU accelerator technology. The Turing and Lobo machines will be decommissioned in the next quarter. ASC projects running on Cielo as part of the CCC-3 include turbulence, hydrodynamics, burn, asteroids, polycrystals, capability and runtime performance improvements, and materials including carbon and silicone.

43 PARTICLE ACCELERATORS↗

On Undecidability Aspects of Resilient Computations and Implications to Exascale

Future Exascale computing systems with a large number of processors, memory elements and interconnection links, are expected to experience multiple, complex faults, which affect both applications and operating-runtime systems. A variety of algorithms, frameworks and tools are being proposed to realize and/or verify the resilience properties of computations that guarantee correct results on failure-prone computing systems. We analytically show that certain resilient computation problems in presence of general classes of faults are undecidable, that is, no algorithms exist for solving them. We first show that the membership verification in a generic set of resilient computations is undecidable. We describe classes of faults that can create infinite loops or non-halting computations, whose detection in general is undecidable. We then show certain resilient computation problems to be undecidable by using reductions from the loop detection and halting problems under two formulations, namely, an abstract programming language and Turing machines, respectively. These two reductions highlight different failure effects: the former represents program and data corruption, and the latter illustrates incorrect program execution. These results call for broad-based, well-characterized resilience approaches that complement purely computational solutions using methods such as hardware monitors, co-designs, and system- and application-specific diagnosis codes.

Exascale systems↗

Initial 1.5D BISON Simulation Verification and Validation CASL FY17 Letter Report

This milestone report describes the current efforts to improve the usability of the recently developed 1.5 dimensional capability in BISON, the initial verification of this BISON capability, and initial validation of the 1.5 dimensional models against existing 2 dimensional axisymmetric full length light water reactor (LWR) fuel rods. The 1.5 dimensional (1.5D) capability in BISON was developed to enable the simulation of LWR fuel rods in a less computationally demanding simulation formulation while retaining key physics of interest. BISON was originally developed to solve 2D axisymmetric and 3D models, and this original development focus allows BISON to examine a wider range of fuel types and geometrically complexity than can be solved with lower dimensional frameworks. As the set of problems which BISON is used to solve expands, the software design requirements continue to evolve. Coupling physics in a higher dimensional geometry is not always required to resolve the physics of interest, such as the modeling of radial heat transfer and radial displacement. BISON, built on the dimension-agnostic MOOSE framework, is able to solve problems in 3D, 2D, and 1D with only minor modifications to the material definition code so that the appropriate geometrical representation can be applied in different problems of interest. The motivation for the development and validation of the BISON 1.5D capability is the CASL program's need for a simplified and computationally efficient version of BISON for use in the large multi-physics VERA simulations which include hundreds of individual fuel rods. The original development of the BISON 1.5D simulation capability is described in the CASL FY17 Letter Report from January 2017, and this report documents the continuing work identified in the previous report. The improvements to the usability of the 1.5D capability through input file simplifications, the results of the verification simulations, the results of the initial validation against the 2D assessment cases in BISON, and the future development needs are included within this report.

1.5D Capability↗

Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate

Winchester/Camberley Homes collaborated with the Building America team Partnership for Home Innovation to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, the project team demonstrated through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the HVAC systems to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

2x6 walls↗

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples – Final Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc. (ESI), the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA® and UTEVA® resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. Based on the initial experience at ORNL with the prepFAST-MC2, a second-generation model, the prepFAST-SR, was built by ESI. The newly designed prepFAST-SR has several upgrades compared with the original prepFAST-MC2. The upgrades largely addressed issues with the reliability of unpacking the Eichrom columns and with ventilation to ensure adequate removal of acid vapors. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL. Separations of mixed uranium and plutonium samples containing certified reference materials were analyzed by multi-collector inductively coupled plasma mass spectrometry and yielded good results. Current efforts have demonstrated a wider applicability of the prepFAST system. Near-quantitative removal of metal interferences was achieved with the system in both uranium and plutonium separated fractions. Successful system validation was completed with several archived samples. Isotopic results from archived samples and certified reference materials were well within data quality limits for the IAEA NWAL. Additional COTS equipment has been evaluated for its potential to aid the prepFAST-SR system in reducing the time allotments and cleanroom infrastructure requirements for accurate separations. Overall, these efforts help ensure continued efficient and effective operation of the NWAL. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced cost by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical Assessment of the Application of Digital Twin and Prognostic Tools for Condition Monitoring

This report was prepared for the U.S. Nuclear Regulatory Commission (NRC) to present use cases of the application of advanced technologies toward meeting the current and future regulatory requirements for maintenance and condition monitoring of structures, systems, and components (SSCs). The advanced technologies considered in this work, collectively referred to as digital twin (DT) technologies, are advanced sensors and instrumentation, data analytics, machine learning and artificial intelligence (ML/AI), and physics-based models. The report presents two use cases of reactor coolant pumps (RCPs) and heat pipes in nuclear power plants (NPPs) with technical and regulatory considerations and opportunities in using advanced technologies for conditional monitoring. Key findings from the exploration of these considerations are as follows: - Uncertainties in sensor data and model predictions must be rigorously addressed through validation and verification processes - Regulatory compliance is paramount, necessitating data driven models to be developed in line with existing codes and standards, as well as considering potential future guidelines for advanced reactors - Explainability and transparency in ML/AI models are essential for developing operator trust and regulatory review, including methods that enhance the interpretability of complex data-driven predictions - Condition monitoring programs must be evaluated for their effectiveness in reducing maintenance-preventable function failures (MPFF) and aligning with plant performance criteria - The deployment of advanced technologies for condition monitoring could lead to a transition from periodic to continuous monitoring, thereby optimizing maintenance schedules - Collaborative efforts between industry stakeholders, regulatory bodies, and technology developers are crucial for the successful adoption of advanced technologies for condition monitoring systems in nuclear facilities In summary, the introduction of advanced technologies into condition monitoring programs represents a significant leap forward in the domain of NPP maintenance. By harnessing the capabilities of advanced sensors, data analytics, and ML/AI, NPP operators can transition from a time-based to a condition-based maintenance approach. This shift can potentially enhance the reliability and safety of critical plant components while optimizing maintenance efforts and minimizing unnecessary outages. The NRC is continuing to explore the regulatory aspects of advanced technologies as part of inservice inspection and inservice testing (ISI and IST) programs by pursuing additional research in this technical area.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The NREL Sensor Laboratory: Status and Future Directions for Hydrogen Detection

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for the national and international hydrogen community to ensure the availability and proper use of hydrogen sensors. Since then, the Sensor Laboratory has provided unbiased verification of hydrogen sensor performance for sensor developers, end-users, and regulatory agencies and has also provided active support for numerous code and standards development organizations. Although sensor performance assessment remains a core capability, the mission of the NREL Sensor Laboratory has expanded toward a more holistic approach regarding the role of hydrogen detection and its implementation strategy for both assurance of facility safety as well as for process control applications. Active monitoring for detection of unintended releases has been identified by the NFPA 2 Storage Task Group as a viable approach for improving facility safety and lowering setbacks. The current research program for the Sensor Laboratory addresses both conventional and advanced developing detection strategies in response to the emerging large-scale markets, such as those envisioned by H2@Scale. These emerging hydrogen applications may require alternative detection strategies that supplement and may ultimately supplant the use of traditional sensors for monitoring hydrogen releases. Research focus areas for the NREL Sensor Laboratory now encompasses the characterization of released hydrogen behavior to optimize detection strategies for both indoor and outdoor applications, advanced methods of hydrogen leak detection such as hydrogen wide area monitoring approaches for large scale and distributed applications, the incorporation of active monitoring as a risk reduction strategy to improve safety at hydrogen facilities, and continuing support of hydrogen safety codes and standards. In addition to assurance of safety, detection will be critical for process control applications, such as hydrogen fuel quality verification for fuel cell vehicle applications and for monitoring and controlling of hydrogen-natural gas blend composition.

codes and standards↗