Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Synthesis, Development, and Testing of High-Surface-Area Polymer-Based Adsorbents for the Selective Recovery of Uranium from Seawater

The ocean contains uranium with an approximate concentration of 3.34 ppb, which can serve as an incredible supply source to sustain nuclear energy in the United States. Unfortunately, technology currently available to recover uranium from seawater is not efficient enough and mining uranium on land is still more economical. For this study, we have developed polymer-based adsorbents with high uranium adsorption capacities by grafting amidoxime onto high-surface-area polyethylene (PE) fibers. Various process conditions have been screened, in combination with developing a rapid testing protocol (<24 h), to optimize the process. These adsorbents are synthesized through radiation-induced grafting of acrylonitrile (AN) and methacrylic acid (MAA) onto PE fibers, followed by the conversion of nitriles to amidoximes and basic conditioning. In addition, the uranium adsorption capacity, measured in units of g U /kg ads , is greatly increased by reducing the diameter of the PE fiber or changing its morphology. An increase in the surface area of the PE polymer fiber allows for more grafting sites that are positioned in more-accessible locations, thereby increasing access to grafted molecules that would normally be located in the interior of a fiber with a larger diameter. Polymer fibers with hollow morphologies are able to adsorb beyond 1 order of magnitude more uranium from simulated seawater than current commercially available adsorbents. Finally, several high-surface-area fibers were tested in natural seawater and were able to extract 5–7 times more uranium than any adsorbent reported to date.

36 MATERIALS SCIENCE↗

Cy-Phy ADS: Cyber Physical Anomaly Detection Framework for EV Charging Systems

Today’s large-scale Electric Vehicle (EV) infrastructures are heavily dependent on information communication technologies to maintain their operation and to support communication within sub-system components as well as the outside world. These technologies are vulnerable to various cyber and physical threats. Timely identification and mitigation of these threats are critical for improving human safety, avoiding economic losses, and preventing catastrophic system failures. By addressing this, our work presents a ResNet Autoencoder (AE) based Cyber-Physical Anomaly Detection System (Cy-Phy ADS) for detecting anomalies in EV Controller Area Network (CAN) protocol communication. It consists of four main components: Cyber-Physical Feature Extractor, ResNet AE-based Anomaly Detection Framework, Cyber-Physical Health Metric (CPHM), and Visualization Dashboard. The presented framework was trained and tested using CAN data collected from the EV charging system testbed at the Idaho National Laboratory. The presented Cy-Phy ADS compared against six widely used unsupervised anomaly detection algorithms: One Class Support Vector Machine (OCSVM), Variational Autoencoder (VAE), LSTM Autoencoder (LSTM AE), Isolation Forest (IForest), Principle Component Analysis (PCA) and Local Outlier Factor (LOF). Here the presented approach showed the highest accuracy among the compared methods. Further, the proposed approach showed comparable performance in terms of precision, F1, and False positive rate. It also showed the lowest training and inference time compared to the neural network-based baseline algorithms compared against with. Additionally, the Cy-Phy ADS has advantages such as unsupervised training, the ability to provide a holistic metric for system health characterization, and non-linear feature extraction.

99 GENERAL AND MISCELLANEOUS↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

A Modern Ethernet Data Acquisition Architecture for Fermilab Beam Instrumentation

The Fermilab Accelerator Division, Instrumentation Department is adopting an open-source framework to replace our embedded VME-based data acquisition systems. Utilizing an iterative methodology, we first moved to embedded Linux, removing the need for VxWorks. Next, we adopted Ethernet on each data acquisition module eliminating the need for the VME backplane in addition to communicating with a rack mount server. Development of DDCP (Distributed Data Communications Protocol), allowed for an abstraction between the firmware and software layers. Each data acquisition module was adapted to read out using 1 GbE and aggregated at a switch which up linked to a 10 GbE network. Current development includes scaling the system to aggregate more modules, to increase bandwidth to support multiple systems and to adopt MicroTCA as a crate technology. The architecture was utilized on various beamlines around the Fermilab complex including PIP2IT, FAST/IOTA and the Muon Delivery Ring. In summary, we were able to develop a data acquisition framework which incrementally replaces VxWorks & VME hardware as well as increases our total bandwidth to 10 Gbit/s using off the shelf Ethernet technology.

43 PARTICLE ACCELERATORS↗

A Framework to Demonstrate a DNP3 Interface With a CIM-Based Data Integration Platform: Preprint

The contemporary electrical grid is characterized by its complexity and abundance of data. A control-rich environment supported by information and communication technologies within an Advanced Distribution Management System (ADMS) presents a viable and cost-effective option for utility companies aiming to implement advanced real-time analytical schemes for monitoring and remotely controlling distribution feeders. Modular platform-based approaches to distribution operations require a structured framework for acquiring field device measurements, performing analytics, converting the setpoint to the correct protocol, and sending it on the appropriate communications network to the field devices. We present the development and deployment of an application service to integrate an open-source standardsbased platform with an ADMS test bed with field devices using the Distributed Network Protocol (DNP3) for data exchange. The step-by-step procedure for establishing the DNP3-Master service on an open-source distribution platform is outlined, comprehensively explaining the Master setup process. Moreover, sample use case results highlight the capabilities of the DNP3- Master service setup. Results demonstrate the scalability and configurability of the DNP3-Master service, making it adaptable for integration with other relevant applications, thus providing potential opportunities for real-world field trials and real-time assessments.

ADMS↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monte Carlo simulations in Nuclear Medicine

Molecular imaging technologies provide unique abilities to localise signs of disease before symptoms appear, assist in drug testing, optimize and personalize therapy, and assess the efficacy of treatment regimes for different types of cancer. Monte Carlo simulation packages are used as an important tool for the optimal design of detector systems. In addition they have demonstrated potential to improve image quality and acquisition protocols. Many general purpose (MCNP, Geant4, etc) or dedicated codes (SimSET etc) have been developed aiming to provide accurate and fast results. Special emphasis will be given to GATE toolkit. The GATE code currently under development by the OpenGATE collaboration is the most accurate and promising code for performing realistic simulations. The purpose of this article is to introduce the non expert reader to the current status of MC simulations in nuclear medicine and briefly provide examples of current simulated systems, and present future challenges that include simulation of clinical studies and dosimetry applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-17: Evaluation of Commercially Available Extension Plates for the ACR CT Accreditation Phantom

Purpose: To evaluate the impact of commercially available extension plates on Hounsfield Unit (HU) values in the ACR CT accreditation phantom (Model 464, Gammex Inc., Middleton, Wi). The extension plates are intended to improve water HU values in scanners where the traditional solution involves scanning the phantom with an adjacent water or CTDI phantom. Methods: The Model 464 phantom was scanned on 9 different CT scanners at 8 separate sites representing 16 and 64 slice MDCT technology from four CT manufacturers. The phantom was scanned with and without the extension plates (Gammex 464 EXTPLT-KIT) in helical and axial modes. A water phantom was also scanned to verify water HU calibration. Technique was 120 kV tube potential, 350 mAs, and 210 mm display field of view. Slice thickness and reconstruction algorithm were based on site clinical protocols. The widest available beam collimation was used. Regions of interest were drawn on the HU test objects in Module 1 of the phantom and mean values recorded. Results: For all axial mode scans, water HU values were within limits with or without the extension plates. For two scanners (both Lightspeed VCT, GE Medical Systems, Waukesha WI), axial mode bone HU values were above the specified range both with and without the extension plates though they were closer to the specified range with the plates installed. In helical scan mode, two scanners (both GE Lightspeed VCT) had water HU values above the specified range without the plates installed. With the plates installed, the water HU values were within range for all scanners in all scan modes. Conclusion: Using the plates, the Lightspeed VCT scanners passed the water HU test when scanning in helical mode. The benefit of the extension plates was evident in helical mode scanning with GE scanners using a nominal 4 cm beam. Disclosure: The extension plates evaluated in this work were provided free of charge to the authors. The authors have no other financial interest in Gammex Inc.

60 APPLIED LIFE SCIENCES↗

Applied Mathematics at the U.S. Department of Energy: Past, Present and a View to the Future

Over the past half-century, the Applied Mathematics program in the U.S. Department of Energy's Office of Advanced Scientific Computing Research has made significant, enduring advances in applied mathematics that have been essential enablers of modern computational science. Motivated by the scientific needs of the Department of Energy and its predecessors, advances have been made in mathematical modeling, numerical analysis of differential equations, optimization theory, mesh generation for complex geometries, adaptive algorithms and other important mathematical areas. High-performance mathematical software libraries developed through this program have contributed as much or more to the performance of modern scientific computer codes as the high-performance computers on which these codes run. The combination of these mathematical advances and the resulting software has enabled high-performance computers to be used for scientific discovery in ways that could only be imagined at the program's inception. Our nation, and indeed our world, face great challenges that must be addressed in coming years, and many of these will be addressed through the development of scientific understanding and engineering advances yet to be discovered. The U.S. Department of Energy (DOE) will play an essential role in providing science-based solutions to many of these problems, particularly those that involve the energy, environmental and national security needs of the country. As the capability of high-performance computers continues to increase, the types of questions that can be answered by applying this huge computational power become more varied and more complex. It will be essential that we find new ways to develop and apply the mathematics necessary to enable the new scientific and engineering discoveries that are needed. In August 2007, a panel of experts in applied, computational and statistical mathematics met for a day and a half in Berkeley, California to understand the mathematical developments required to meet the future science and engineering needs of the DOE. It is important to emphasize that the panelists were not asked to speculate only on advances that might be made in their own research specialties. Instead, the guidance this panel was given was to consider the broad science and engineering challenges that the DOE faces and identify the corresponding advances that must occur across the field of mathematics for these challenges to be successfully addressed. As preparation for the meeting, each panelist was asked to review strategic planning and other informational documents available for one or more of the DOE Program Offices, including the Offices of Science, Nuclear Energy, Fossil Energy, Environmental Management, Legacy Management, Energy Efficiency & Renewable Energy, Electricity Delivery & Energy Reliability and Civilian Radioactive Waste Management as well as the National Nuclear Security Administration. The panelists reported on science and engineering needs for each of these offices, and then discussed and identified mathematical advances that will be required if these challenges are to be met. A review of DOE challenges in energy, the environment and national security brings to light a broad and varied array of questions that the DOE must answer in the coming years. A representative subset of such questions includes: (1) Can we predict the operating characteristics of a clean coal power plant? (2) How stable is the plasma containment in a tokamak? (3) How quickly is climate change occurring and what are the uncertainties in the predicted time scales? (4) How quickly can an introduced bio-weapon contaminate the agricultural environment in the US? (5) How do we modify models of the atmosphere and clouds to incorporate newly collected data of possibly of new types? (6) How quickly can the United States recover if part of the power grid became inoperable? (7) What are optimal locations and communication protocols for sensing devices in a remote-sensing network? (8) How can new materials be designed with a specified desirable set of properties? In comparing and contrasting these and other questions of importance to DOE, the panel found that while the scientific breadth of the requirements is enormous, a central theme emerges: Scientists are being asked to identify or provide technology, or to give expert analysis to inform policy-makers that requires the scientific understanding of increasingly complex physical and engineered systems. In addition, as the complexity of the systems of interest increases, neither experimental observation nor mathematical and computational modeling alone can access all components of the system over the entire range of scales or conditions needed to provide the required scientific understanding.

99 GENERAL AND MISCELLANEOUS↗

Quantitative interpretation of molecular dynamics simulations for X-ray photoelectron spectroscopy of aqueous solutions

Over the past decade, energy-dependent ambient pressure X-ray photoelectron spectroscopy (XPS) has emerged as a powerful analytical probe of the ion spatial distributions at the vapor (vacuum)-aqueous electrolyte interface. These experiments are often paired with complementary molecular dynamics (MD) simulations in an attempt to provide a complete description of the liquid interface. There is, however, no systematic protocol that permits a straightforward comparison of the two sets of results. XPS is an integrated technique that averages signals from multiple layers in a solution even at the lowest photoelectron kinetic energies routinely employed, whereas MD simulations provide a microscopic layer-by-layer description of the solution composition near the interface. Here, we use the National Institute of Standards and Technology database for the Simulation of Electron Spectra for Surface Analysis (SESSA) to quantitatively interpret atom-density profiles from MD simulations for XPS signal intensities using sodium and potassium iodide solutions as examples. We show that electron inelastic mean free paths calculated from a semi-empirical formula depend strongly on solution composition, varying by up to 30% between pure water and concentrated NaI. The XPS signal thus arises from different information depths in different solutions for a fixed photoelectron kinetic energy. XPS signal intensities are calculated using SESSA as a function of photoelectron kinetic energy (probe depth) and compared with a widely employed ad hoc method. SESSA simulations illustrate the importance of accounting for elastic-scattering events at low photoelectron kinetic energies (<300 eV) where the ad hoc method systematically underestimates the preferential enhancement of anions over cations. Finally, some technical aspects of applying SESSA to liquid interfaces are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diazotroph Community Characterization via a High-Throughput nifH Amplicon Sequencing and Analysis Pipeline

The dinitrogenase reductase gene ( nifH ) is the most widely established molecular marker for the study of nitrogen-fixing prokaryotes in nature. A large number of PCR primer sets have been developed for nifH amplification, and the effective deployment of these approaches should be guided by a rapid, easy-to-use analysis protocol. Bioinformatic analysis of marker gene sequences also requires considerable expertise. In this study, we advance the state of the art for nifH analysis by evaluating nifH primer set performance, developing an improved amplicon sequencing workflow, and implementing a user-friendly bioinformatics pipeline. Furthermore, the developed amplicon sequencing workflow is a three-stage PCR-based approach that uses established technologies for incorporating sample-specific barcode sequences and sequencing adapters. Based on our primer evaluation, we recommend the Ando primer set be used with a modified annealing temperature of 58°C, as this approach captured the largest diversity of nifH templates, including paralog cluster IV/V sequences. To improve nifH sequence analysis, we developed a computational pipeline which infers taxonomy and optionally filters out paralog sequences. In addition, we employed an empirical model to derive optimal operational taxonomic unit (OTU) cutoffs for the nifH gene at the species, genus, and family levels. A comprehensive workflow script named TaxADivA (TAXonomy Assignment and DIVersity Assessment) is provided to ease processing and analysis of nifH amplicons. Our approach is then validated through characterization of diazotroph communities across environmental gradients in beach sands impacted by the Deepwater Horizon oil spill in the Gulf of Mexico, in a peat moss-dominated wetland, and in various plant compartments of a sugarcane field. IMPORTANCE: Nitrogen availability often limits ecosystem productivity, and nitrogen fixation, exclusive to prokaryotes, comprises a major source of nitrogen input that sustains food webs. The nifH gene, which codes for the iron protein of the nitrogenase enzyme, is the most widely established molecular marker for the study of nitrogen-fixing microorganisms (diazotrophs) in nature. In this study, a flexible sequencing/analysis pipeline, named TaxADivA, was developed for nifH amplicons produced by Illumina paired-end sequencing, and it enables an inference of taxonomy, performs clustering, and produces output in formats that may be used by programs that facilitate data exploration and analysis. Diazotroph diversity and community composition are linked to ecosystem functioning, and our results advance the phylogenetic characterization of diazotroph communities by providing empirically derived nifH similarity cutoffs for species, genus, and family levels. Thus, the utility of our pipeline is validated for diazotroph communities in a variety of ecosystems, including contaminated beach sands, peatland ecosystems, living plant tissues, and rhizosphere soil.

59 BASIC BIOLOGICAL SCIENCES↗

Spectral and Temperature-Dependent Optical Metrology: Towards More Robust, Effective and Durable Materials for Concentrated Solar Power

The primary objective of this project is to develop reliable and standardized spectroscopic measurement techniques to determine radiative properties, specifically the emittance and reflectance, of materials relevant for the next generation (Gen3) concentrated solar power (CSP) technologies. Experimental measurements will span near- and mid-infrared wavelengths (1–20 µm) with emphasis on quantifying the influences of: (1) operating temperatures of 25–1000 °C, (2) thermal cycling, and (3) environmental exposure of materials during operation (vacuum/air). A secondary goal is to develop open-access and digitized databases to host and share experimental data, together with standardized measurement protocols and operating procedures to determine optical properties of materials. This project will also include reasonable emphasis on developing predictive modeling tools to augment experimental data to extract more fundamental and material-specific radiative properties.

14 SOLAR ENERGY↗

Hafnium Isotope Ratio Method for Enhanced Safeguards at Research Reactors

Pacific Northwest National Laboratory (PNNL) is developing a Hafnium (Hf)-based, enhanced safeguards measure for the verification of energy production in a research reactor. Historically, verification of nuclear reactor use has been based on extracting and measuring physical samples from non-fuel components of the reactor. The Hafnium Isotope Ratio Method for Enhanced Safeguards (HIRMES) provides a means of verifying reactor operation based upon measuring the changes in isotopic ratios in purpose-built coupons. The first activity is installing a purpose-built, integrated sample collection coupon containing hafnium which undergoes isotopic changes when irradiated in the reactor. The second activity is analysis of the isotopic changes of the irradiated coupon after removal of the coupon using the isotope ratio method (IRM). The energy, or plutonium production, in a fission reactor can be estimated using IRM by measuring and correlating stable isotope ratios in non-fuel reactor components using standard reactor modelling methods. This paper presents HIRMES, a technology intended to provide an inexpensive, accurate, and robust measurement capability for validating operator declarations at low-power research reactors. Deploying HIRMES in research reactors would provide the IAEA with an in-core reactor “odometer” on total energy production with higher accuracy than other methods. HIRMES could be integrated in new fuel or reactor core designs as part of a protocol that is simple to implement and minimizes effort required of the operator or inspector. This paper also discusses early demonstrations at U.S. research reactors to-date, which demonstrate HIRMES as a practical tool for independent verification of low-power research reactor utilization. Specifically, the measurement uncertainty during an irradiation campaign of 39766 MWh was 22 MWh, representing two hours at a 10 MW reactor for a total irradiation campaign over the course of approximately six months.

research reactor safeguards, isotope ratio method↗

Witnessing Entanglement and Quantum Correlations in Condensed Matter: A Review

The detection and certification of entanglement and quantum correlations in materials is of fundamental and far-reaching importance, and has seen significant recent progress. It impacts both the understanding of the basic science of quantum many-body phenomena as well as the identification of systems suitable for novel technologies. Frameworks suitable to condensed matter that connect measurements to entanglement and coherence have been developed in the context of quantum information theory. These take the form of entanglement witnesses and quantum correlation measures. Here, the underlying theory of these quantities, their relation to condensed matter experimental techniques, and their application to real materials are comprehensively reviewed. In addition, their usage in, e.g., protocols, the relative advantages and disadvantages of witnesses and measures, and future prospects in, e.g., correlated electrons, entanglement dynamics, and entangled spectroscopic probes, are presented. Consideration is given to the interdisciplinary nature of this emerging research and substantial ongoing progress by providing an accessible and practical treatment from fundamentals to application. Particular emphasis is placed on quantities accessible to collective measurements, including by susceptibility and spectroscopic techniques. This includes the magnetic susceptibility witness, one-tangle, concurrence and two-tangle, two-site quantum discord, and quantum coherence measures such as the quantum Fisher information.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Complications of Microwave Ablation for Liver Tumors: Results of a Multicenter Study

Purpose: New technologies for microwave ablation (MWA) have been conceived, designed to achieve larger areas of necrosis compared with radiofrequency ablation (RFA). The purpose of this study was to report complications by using this technique in patients with focal liver cancer. Methods: Members of 14 Italian centers used a 2.45-GMHz generator delivering energy through a cooled miniature-choke MW antenna and a standardized protocol for follow-up. They completed a questionnaire regarding number and type of deaths, major and minor complications and side effects, and likelihood of their relationship to the procedure. Enrollment included 736 patients with 1.037 lesions: 522 had hepatocellular carcinoma with cirrhosis, 187 had metastases predominantly from colorectal cancer, and 27 had cholangiocellular carcinoma. Tumor size ranged from 0.5 to 10 cm. In 13 centers, the approach used was percutaneous, in 4 videolaparoscopic, and in 3 laparotomic. Results: No deaths were reported. Major complications occurred in 22 cases (2.9%), and minor complications in 54 patients (7.3%). Complications of MWA do not differ from those RFA, both being based on the heat damage. Conclusion: Results of this multicenter study confirmed those of single-center experiences, indicating that MWA is a safe procedure, with no mortality and a low rate of major complications. The low rate of complications was probably due to precautions adopted, knowing in advance possible risk conditions, on the basis of prior RFA experience.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mimicking Martian dust: An in-vacuum dust deposition system for testing the ultraviolet sensors on the Curiosity rover

We have designed and developed an in-vacuum dust deposition system specifically conceived to simulate and study the effect of accumulation of Martian dust on the electronic instruments of scientific planetary exploration missions. We have used this device to characterize the dust effect on the UV sensor of the Rover Environmental Monitoring Station in the Mars science Laboratory mission of NASA in similar conditions to those found on Mars surface. The UV sensor includes six photodiodes for measuring the radiation in all UV wavelengths (direct incidence and reflected); it is placed on the body of Curiosity rover and it is severely affected by the dust deposited on it. Our experimental setup can help to estimate the duration of reliable reading of this instrument during operation. We have used an analogous of the Martian dust in chemical composition (magnetic species), color, and density, which has been characterized by X-ray spectroscopy. To ensure a Brownian motion of the dust during its fall and a homogeneous coverage on the instrumentation, the operating conditions of the vacuum vessel, determined by partial pressures and temperature, have to be modified to account for the different gravities of Mars with respect to Earth. We propose that our designed device and operational protocol can be of interest to test optoelectronic instrumentation affected by the opacity of dust, as can be the degradation of UV photodiodes in planetary exploration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast valley polarization in bilayer graphene

We study theoretically the interaction of a bilayer graphene with a circularly polarized ultrafast optical pulse of a single oscillation at an oblique incidence. The normal component of the pulse breaks the inversion symmetry of the system and opens up a dynamical bandgap due to which a valley-selective population of the conduction band becomes sensitive to the angle of incident of the pulse. We show that the magnitude of the valley polarization can be controlled by the angle of incidence, the amplitude, and the angle of in-plane polarization of the chiral optical pulse. Subsequently, a sequence of a circularly polarized pulse followed by a linearly polarized femtosecond-long pulse can be used to control and probe the valley polarization created by the preceding pulse. Our protocol provides a favorable platform to design ultrafast all-optical valleytronic information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave quantum memory on a controlled frequency comb

We consider a protocol of broadband quantum memory on a controlled frequency comb of spectral lines of ring microwave resonators connected to a common strip waveguide. A prototype of this memory is manufactured, on which the room-temperature preservation of microwave pulses with an efficiency of about 3 % is demonstrated. The experimentally obtained efficiency can be enhanced to a level above 90 % using modern microwave technologies and conducting experiments at helium temperatures, which opens a new way for the development of integrated microwave quantum memory. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗