Search NASA⌕ Search

SEARCH · Search NASA

Results for “range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Ares I-X Range Safety Simulation Verification and Analysis IV and V

NASA s ARES I-X vehicle launched on a suborbital test flight from the Eastern Range in Florida on October 28, 2009. NASA generated a Range Safety (RS) flight data package to meet the RS trajectory data requirements defined in the Air Force Space Command Manual 91-710. Some products included in the flight data package were a nominal ascent trajectory, ascent flight envelope trajectories, and malfunction turn trajectories. These data are used by the Air Force s 45th Space Wing (45SW) to ensure Eastern Range public safety and to make flight termination decisions on launch day. Due to the criticality of the RS data in regards to public safety and mission success, an independent validation and verification (IV&V) effort was undertaken to accompany the data generation analyses to ensure utmost data quality and correct adherence to requirements. Multiple NASA centers and contractor organizations were assigned specific products to IV&V. The data generation and IV&V work was coordinated through the Launch Constellation Range Safety Panel s Trajectory Working Group, which included members from the prime and IV&V organizations as well as the 45SW. As a result of the IV&V efforts, the RS product package was delivered with confidence that two independent organizations using separate simulation software generated data to meet the range requirements and yielded similar results. This document captures ARES I-X RS product IV&V analysis, including the methodology used to verify inputs, simulation, and output data for an RS product. Additionally a discussion of lessons learned is presented to capture advantages and disadvantages to the IV&V processes used.

Tarpley, Ashley↗

Multiple-Zone Diffractive Optic Element for Laser Ranging Applications

A diffractive optic element (DOE) can be used as a beam splitter to generate multiple laser beams from a single input laser beam. This technology has been recently used in LRO s Lunar Orbiter Laser Altimeter (LOLA) instrument to generate five laser beams that measure the lunar topography from a 50-km nominal mapping orbit (see figure). An extension of this approach is to use a multiple-zone DOE to allow a laser altimeter instrument to operate over a wider range of distances. In particular, a multiple-zone DOE could be used for applications that require both mapping and landing on a planetary body. In this case, the laser altimeter operating range would need to extend from several hundred kilometers down to a few meters. The innovator was recently involved in an investigation how to modify the LOLA instrument for the OSIRIS asteroid mapping and sample return mission. One approach is to replace the DOE in the LOLA laser beam expander assembly with a multiple-zone DOE that would allow for the simultaneous illumination of the asteroid with mapping and landing laser beams. The proposed OSIRIS multiple-zone DOE would generate the same LOLA five-beam output pattern for high-altitude topographic mapping, but would simultaneously generate a wide divergence angle beam using a small portion of the total laser energy for the approach and landing portion of the mission. Only a few percent of the total laser energy is required for approach and landing operations as the return signal increases as the inverse square of the ranging height. A wide divergence beam could be implemented by making the center of the DOE a diffractive or refractive negative lens. The beam energy and beam divergence characteristics of a multiple-zone DOE could be easily tailored to meet the requirements of other missions that require laser ranging data. Current single-zone DOE lithographic manufacturing techniques could also be used to fabricate a multiple-zone DOE by masking the different DOE zones during the manufacturing process, and the same space-compatible DOE substrates (fused silica, sapphire) that are used on standard DOE s could be used for multiple- zone DOE s. DOEs are an elegant and cost-effective optical design option for spacebased laser altimeters that require multiple output laser beams. The use of multiple-zone DOEs would allow for the design and optimization of a laser altimeter instrument required to operate over a large range of target distances, such as those designed to both map and land on a planetary body. In addition to space-based laser altimeters, this technology could find applications in military or commercial unmanned aerial vehicles (UAVs) that fly at an altitude of several kilometers and need to land. It is also conceivable that variations of this approach could be used in land-based applications such as collision avoidance and robotic control of cars, trains, and ships.

Ramos-Izquierdo, Luis A.↗

Surveillance Range and Interference Impacts on Self-Separation Performance

Self-separation is a concept of flight operations that aims to provide user benefits and increase airspace capacity by transferring traffic separation responsibility from ground-based controllers to the flight crew. Self-separation is enabled by cooperative airborne surveillance, such as that provided by the Automatic Dependent Surveillance-Broadcast (ADSB) system and airborne separation assistance technologies. This paper describes an assessment of the impact of ADS-B system performance on the performance of self-separation as a step towards establishing far-term ADS-B performance requirements. Specifically, the impacts of ADS-B surveillance range and interference limitations were analyzed under different traffic density levels. The analysis was performed using a batch simulation of aircraft performing self-separation assisted by NASA s Autonomous Operations Planner prototype flight-deck tool, in two-dimensional airspace. An aircraft detected conflicts within a look-ahead time of ten minutes and resolved them using strategic closed trajectories or tactical open maneuvers if the time to loss of separation was below a threshold. While a complex interaction was observed between the impacts of surveillance range and interference, as both factors are physically coupled, self-separation performance followed expected trends. An increase in surveillance range resulted in a decrease in the number of conflict detections, an increase in the average conflict detection lead time, and an increase in the percentage of conflict resolutions that were strategic. The majority of the benefit was observed when surveillance range was increased to a value corresponding to the conflict detection look-ahead time. The benefits were attenuated at higher interference levels. Increase in traffic density resulted in a significant increase in the number of conflict detections, as expected, but had no effect on the conflict detection lead time and the percentage of conflict resolutions that were strategic. With surveillance range corresponding to ADS-B minimum operational performance standards for Class A3 equipment and without background interference, a significant portion of conflict resolutions, 97 percent, were achieved in the preferred strategic mode. The majority of conflict resolutions, 71 percent, were strategic even with very high interference (over three times that expected in 2035).

Idris, Husni↗

Laser Ranging Simulation Program

Laser Ranging Simulation Program (LRSP) is a computer program that predicts selected aspects of the performances of a laser altimeter or other laser ranging or remote-sensing systems and is especially applicable to a laser-based system used to map terrain from a distance of several kilometers. Designed to run in a more recent version (5 or higher) of the MATLAB programming language, LRSP exploits the numerical and graphical capabilities of MATLAB. LRSP generates a graphical user interface that includes a pop-up menu that prompts the user for the input of data that determine the performance of a laser ranging system. Examples of input data include duration and energy of the laser pulse, the laser wavelength, the width of the laser beam, and several parameters that characterize the transmitting and receiving optics, the receiving electronic circuitry, and the optical properties of the atmosphere and the terrain. When the input data have been entered, LRSP computes the signal-to-noise ratio as a function of range, signal and noise currents, and ranging and pointing errors.

Piazolla, Sabino↗

Frequency-Modulated, Continuous-Wave Laser Ranging Using Photon-Counting Detectors

Optical ranging is a problem of estimating the round-trip flight time of a phase- or amplitude-modulated optical beam that reflects off of a target. Frequency- modulated, continuous-wave (FMCW) ranging systems obtain this estimate by performing an interferometric measurement between a local frequency- modulated laser beam and a delayed copy returning from the target. The range estimate is formed by mixing the target-return field with the local reference field on a beamsplitter and detecting the resultant beat modulation. In conventional FMCW ranging, the source modulation is linear in instantaneous frequency, the reference-arm field has many more photons than the target-return field, and the time-of-flight estimate is generated by balanced difference- detection of the beamsplitter output, followed by a frequency-domain peak search. This work focused on determining the maximum-likelihood (ML) estimation algorithm when continuous-time photoncounting detectors are used. It is founded on a rigorous statistical characterization of the (random) photoelectron emission times as a function of the incident optical field, including the deleterious effects caused by dark current and dead time. These statistics enable derivation of the Cramér-Rao lower bound (CRB) on the accuracy of FMCW ranging, and derivation of the ML estimator, whose performance approaches this bound at high photon flux. The estimation algorithm was developed, and its optimality properties were shown in simulation. Experimental data show that it performs better than the conventional estimation algorithms used. The demonstrated improvement is a factor of 1.414 over frequency-domainbased estimation. If the target interrogating photons and the local reference field photons are costed equally, the optimal allocation of photons between these two arms is to have them equally distributed. This is different than the state of the art, in which the local field is stronger than the target return. The optimal processing of the photocurrent processes at the outputs of the two detectors is to perform log-matched filtering followed by a summation and peak detection. This implies that neither difference detection, nor Fourier-domain peak detection, which are the staples of the state-of-the-art systems, is optimal when a weak local oscillator is employed.

Erkmen, Baris I.↗

Performance of Wide Operating Temperature Range Electrolytes in Quallion Prototype Li-Ion Cells

For a number of applications, there is a continued interest in the development of rechargeable lithium-based batteries that can effectively operate over a wide temperature range (i.e., -40 to +70 deg C). These applications include powering future planetary rovers for NASA, enabling the next generation of automotive batteries for DOE, and supporting many DOD applications. Li-ion technology has been demonstrated to have good performance over a reasonably wide temperature range with many systems; however, there is still a desire to improve the low temperature rate capacity as well as the high temperature resilience. In the current study, we would like to present recent results obtained with prototype Li-Ion cells (manufactured by Quallion, LLC) which include various wide operating temperature range electrolytes developed by both JPL and Quallion. To demonstrate the viability of the technology, a number of performance tests were carried out, including: (a) discharge rate characterization over a wide temperature range (down to -60 deg C) using various rates (up to 20C rates), (b) discharge rate characterization at low temperatures with low temperature charging, (c) variable temperature cycling over a wide temperature range (-40 to +70 deg C), and (d) cycling at high temperature (50 deg C). As will be discussed, impressive rate capability was observed at low temperatures with many systems, as well as good resilience to high temperature cycling. To augment the performance testing on the prototype cells, a number of experimental three electrodes cells were fabricated (including Li reference electrodes) to allow the determination of the lithium kinetics of the respective electrodes and interfacial properties as a function of temperatures.

Lithium-ion↗

ICESAT GLAS Altimetry Measurements: Received Signal Dynamic Range and Saturation Correction

NASAs Ice, Cloud, and land Elevation Satellite (ICESat), which operated between 2003 and 2009, made the first satellite-based global lidar measurement of earths ice sheet elevations, sea-ice thickness, and vegetation canopy structure. The primary instrument on ICESat was the Geoscience Laser Altimeter System (GLAS), which measured the distance from the spacecraft to the earth's surface via the roundtrip travel time of individual laser pulses. GLAS utilized pulsed lasers and a direct detection receiver consisting of a silicon avalanche photodiode and a waveform digitizer. Early in the mission, the peak power of the received signal from snow and ice surfaces was found to span a wider dynamic range than anticipated, often exceeding the linear dynamic range of the GLAS 1064-nm detector assembly. The resulting saturation of the receiver distorted the recorded signal and resulted in range biases as large as approximately 50 cm for ice- and snow-covered surfaces. We developed a correction for this saturation range bias based on laboratory tests using a spare flight detector, and refined the correction by comparing GLAS elevation estimates with those derived from Global Positioning System surveys over the calibration site at the salar de Uyuni, Bolivia. Applying the saturation correction largely eliminated the range bias due to receiver saturation for affected ICESat measurements over Uyuni and significantly reduced the discrepancies at orbit crossovers located on flat regions of the Antarctic ice sheet.

Sun, Xiaoli↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. The study findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. These findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗

UAS Pilot Performance Comparisons with Different Low Size, Weight and Power Sensor Ranges

The present study evaluated the performance of UAS pilots under four simulated low size, weight, and power (SwaP) sensor ranges: 1.5nmi, 2.0nmi, 2.5nmi, and 3.0nmi. Nine active-duty UAS pilots responded to scripted DAA conflicts against non-cooperative intruders while flying a simulated RQ-7 Shadow at varied speeds along a pre-filed flight path in Class E airspace. Findings revealed a linear effect of sensor range on alerting time and separation performance, with nearly every DAA well clear (DWC) violation and all Near Mid-Air Collision (NMAC) events occurring below 2.5nmi. Response time differences at these reduced ranges were negligible due to the high frequency of warning-level alerts that require an immediate response. Since caution alert duration was truncated to some degree by each tested declaration range, pilots were often unable to coordinate their avoidance maneuvers with ATC prior to their uploads. Nonetheless, the 2.5nmi range allowed minimum alerting times that were sufficient for acceptable pilot performance. These findings will inform DAA system requirements for UAS with alternative surveillance equipment and aircraft performance capabilities. Implications on DAA display and sensor requirements are discussed.

unmanned aircraft systems↗

An Evaluation of UAS Pilot Workload and Acceptability Ratings with Four Simulated Radar Declaration Ranges

Currently, minimum operational performance standards (MOPS) are being developed for a broader range of unmanned aircraft system (UAS) platforms, including smaller UAS that will feature onboard sensors that are low in size, weight, and power, otherwise known as low SWaP. The low SWaP sensors used to detect non-cooperative traffic will have limited declaration ranges compared to those designed for medium-to-large UAS. A human-in-the-loop (HITL) study was conducted examining four possible radar declaration ranges (i.e., 1.5 NM, 2 NM, 2.5 NM, and 3 NM) for a potential low SWaP sensor with a detect and avoid (DAA) system encountering various non-cooperative encounters in Oakland Center airspace. Participants had lower workload, particularly workload associated with temporal demand and effort, in scenarios that featured larger declaration ranges. Furthermore, participants reported better ability to remain DAA well clear within the larger declaration range conditions, specifically with the 2.5 NM and 3 NM conditions.

UAS↗

An Evaluation of UAS Pilot Workload and Acceptability Ratings with Four Simulated Radar Declaration Ranges

Currently, minimum operational performance standards (MOPS) are being developed for a broader range of unmanned aircraft system (UAS) platforms, including smaller UAS that will feature onboard sensors that are low in size, weight, and power, otherwise known as low SWaP. The low SWaP sensors used to detect non-cooperative traffic will have limited declaration ranges compared to those designed for medium-to-large UAS. A human-in-the-loop (HITL) study was conducted examining four possible radar declaration ranges (i.e., 1.5 NM, 2 NM, 2.5 NM, and 3 NM) for a potential low SWaP sensor with a detect and avoid (DAA) system encountering various non-cooperative encounters in Oakland Center airspace. Participants had lower workload, particularly workload associated with temporal demand and effort, in scenarios that featured larger declaration ranges. Furthermore, participants reported better ability to remain DAA well clear within the larger declaration range conditions, specifically with the 2.5 NM and 3 NM conditions.

UAS↗

Recent Progress in the International Laser Ranging Service (ILRS)

The International Laser Ranging Service (ILRS) provides Satellite Laser Ranging (SLR) and Lunar Laser Ranging (LLR) observations and data products with a focus on Earth and Lunar science and engineering applications. The basic observables are the precise two-way time-of-flight of ultra-short laser pulses from ground stations to retroreflector arrays on satellites and the Moon and the one-way time-of-flight measurements to space-borne receivers (transponders). SLR is one of the four space geodetic techniques (along with VLBI, GNSS, and DORIS). The International Terrestrial Reference Frame (ITRF) development, maintained by IERS, is based on these geodetic observations. Fundamental data products include accurate satellite ephemerides, Earth orientation parameters, three dimensional coordinates and velocities of the ILRS tracking stations, time-varying geocenter coordinates, static and time-varying coefficients of the Earth’s gravity field, fundamental physical constants, lunar ephemerides and librations, and lunar orientation parameters. The ILRS continues to expand spatial and temporal coverage of SLR observations. New stations with new technologies are being deployed; existing stations are being upgraded. Some of these stations are multi-technique Core Sites. New satellites are expanding applications and strengthening the ILRS contribution to the reference frame. New analysis, modeling, and data processing techniques are improving data products. New campaigns are expanding our applications into relativity and the study of non-gravitational forces. New activities are underway on Lunar Laser Ranging, Time Transfer, and Space Debris Tracking, helping to expand laser ranging applications. This talk will give an update on the current ILRS activities and their impact on ILRS data products.

Report on the ILRS activities↗

Assembling a Cyber Range to Evaluate Artificial Intelligence / Machine Learning (AI/ML) Security Tools

In this case study, we will describe the design and assembly of a cyber security test range we have built at Oak Ridge National Laboratory in Oak Ridge, TN, USA. The range is designed to provide a flexible environment to evaluate cyber security tools—particularly those involving AI/ML—in a way that provides realistic environments and where we can control the experiments to determine the strengths and weaknesses of the tools. We have designed in the ability to repeat the evaluations, so additional tools can be evaluated and compared at a later time. The system is one that can be scaled up or down for experiment sizes. At the time of the conference we will have completed two full-scale, national, government challenges on this range. These challenges are evaluating the performance and operating costs for AI/ML-based cyber security tools for application into large, government-sized environments. These evaluations will be described, in order to provide motivation and context for various design decisions and adaptations we have made. The first challenge measured end-point security tools against 100K malware samples chosen across a range of types. The second is network detection of attempted penetration and exploitations with varying levels of covertness in a high-volume, business network. The scale of each of these challenges is requiring us to create automation systems to repeat the experiments identically for each tool. Preventing there being easy signs of malicious activity for the AI/ML tools to focus on has been a particularly interesting and challenging aspect of designing and executing these challenge events. After the events, the range continues to be used for other research such as adversarial machine learning where the repeatability, scale, and automation required for the national challenge events become essential elements for research.

Nichols, Jeff↗

Wide-range fission chambers signal simulator - 373

Fission chambers (FC) signal simulators are a useful means to test neutron flux instrumentation channels of the reactors control and protection systems (CPS). Well-known signal simulators do not provide a secondary equipment testing in all modes of measurement. A wide range simulator that simulates a full range of FC signal changes (pulse, fluctuation, current) was designed. The simulator takes into account the statistical nature of neutrons detection in the FC, including the shape of the pulse and the spectrum of the pulse amplitude distribution. The simulator uses the principle of mathematical simulation of the fission chambers signal with realtime calculations using the FPGA. The wide-range simulator reproduces a FC signal in the range of ten orders without switching ranges or playback modes while ensuring very good linearity. It allows to generate both static and dynamic test signals such as: stair-step, linearly and exponential varying signals, exponential varying signals with a linearly changing period or a signal change simulating the response of the nuclear reactor power to a given reactivity response. Continuity of reproduced signals and the ability to playback dynamic effects makes it possible the simulator using to check the algorithms of cross-linking of measuring paths, reactivity and period measuring tools and to monitor the operation of interlocking and alarm CPS functions. This article discusses the simulator's software and hardware, its features and specifications, user interface and example of the simulator using to check the neutron flux monitoring channels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Benchmark $k$ eff Sensitivity and Uncertainty for 239 Pu fission in Specific Energy Ranges

Nuclear data at intermediate energies (from 1 to 100s of keV) are evaluated based on scarce differential data and theory unable to capture physics’ expected structure. There is also a lack of integral data. This is a known deficiency and is challenging to address. Calculated effective multiplication factor, k eff , values for intermediate energy experiments are ~25× further from experiment than for fast energies and are often well outside the experimental uncertainties. The goal of the PARADIGM (PARallel Approach of Differential and InteGral Measurements) project is to significantly re duce the uncertainties of intermediate energy nuclear data for 239 Pu. To this end, PARADIGM simultaneously optimizes experiments at both the Los Alamos Neutron Science Center (LANSCE) and National Criticality Experiments Research Center (NCERC). The combined set of data will inform new intermediate-energy nuclear data. By execution of differential and integral experiments, establishment of new theory, and undertaking nuclear data evaluation in parallel, the timeline to deliver improved nuclear data to users will be reduced significantly that is to three years. For the PARADIGM project, it was decided to optimize an integral experiment for two neutron energy ranges, within the full intermediate energy range. The low energy range goes from 1 to 30 keV, while the higher energy range goes from 30 to 600 keV. This work focuses on nuclear data sensitivities and uncertainties for 239 Pu fission for existing experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). When designing new experiments, it is important to understand what benchmarks currently exist. For a more traditional experiment design (in which a specific application model(s) exists), comparisons would be made between the application model(s) and existing benchmarks. For PARADIGM, there is no specific application model, but instead the specific nuclear data reaction and energy ranges of interest can be explored for existing benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced tunable magnetoresistance properties over a wide temperature range in epitaxial (La{sub 0.7}Sr{sub 0.3}MnO{sub 3}){sub 1−x}:(CeO{sub 2}){sub x} nanocomposites

Vertically aligned nanocomposite (VAN) (La{sub 0.7}Sr{sub 0.3}MnO{sub 3}){sub 1−x}:(CeO{sub 2}){sub x} (LSMO:CeO{sub 2}) thin films have been grown on SrTiO{sub 3} (001) substrates by pulsed laser deposition. Tunable magnetoresistance properties as well as microstructures are demonstrated in these VAN films by modulating the film composition (x = 0, 0.3, 0.4, 0.45, 0.5, and 0.55). The sample of x = 0.3 shows a large low-field magnetoresistance (LFMR) in a high temperature range, i.e., over 10% at the range of 280 K to 320 K under 1 T and with a peak value of ∼13.5% at 310 K. In addition, a vast enhancement of LFMR in a low temperature range of 20–150 K with peak of ≈34.3% at 45 K for 1 T could be achieved with x = 0.5. The enhanced LFMR properties can be attributed to both the phase boundary induced spin fluctuation and the magnetic tunneling effect through vertical ferromagnetic/insulator/ferromagnetic structures. The observed enhanced LFMR performance, especially at high temperatures, as well as its simple growth method, offers a great potential for LSMO:CeO{sub 2}nanocomposites to be used in spintronic devices in a large temperature range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acoustic time-of-flight for proton range verification in water

Purpose: Measurement of the arrival times of thermoacoustic waves induced by pulsed proton dose depositions (protoacoustics) may provide a proton range verification method. The goal of this study is to characterize the required dose and protoacoustic proton range (distance) verification accuracy in a homogeneous water medium at a hospital-based clinical cyclotron. Methods: Gaussian-like proton pulses with 17 μs widths and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 3.4 cGy/pulse at the Bragg peak) were generated by modulating the cyclotron proton source with a function generator. After energy degradation, the 190 MeV proton pulses irradiated a water phantom, and the generated protoacoustic emissions were measured by a hydrophone. The detector position and proton pulse characteristics were varied. The experimental results were compared to simulations. Different arrival time metrics derived from acoustic waveforms were compared, and the accuracy of protoacoustic time-of-flight distance calculations was assessed. Results: A 27 mPa noise level was observed in the treatment room during irradiation. At 5 cm from the proton beam, an average maximum pressure of 5.2 mPa/1 × 10{sup 7} protons (6.1 mGy at the Bragg peak) was measured after irradiation with a proton pulse with 10%–90% rise time of 11 μs. Simulation and experiment arrival times agreed well, and the observed 2.4 μs delay between simulation and experiment is attributed to the difference between the hydrophone’s acoustic and geometric centers. Based on protoacoustic arrival times, the beam axis position was measured to within (x, y) = (−2.0, 0.5) ± 1 mm. After deconvolution of the exciting proton pulse, the protoacoustic compression peak provided the most consistent measure of the distance to the Bragg peak, with an error distribution with mean = − 4.5 mm and standard deviation = 2.0 mm. Conclusions: Based on water tank measurements at a clinical hospital-based cyclotron, protoacoustics is a potential method for measuring the beam’s position (x and y within 2.0 mm) and Bragg peak range (2.0 mm standard deviation), although range verification will require simulation or experimental calibration to remove systematic error. Based on extrapolation, a protoacoustic arrival time reproducibility of 1.5 μs (2.2 mm) is achievable with 2 Gy of total deposited dose. Of the compared methods, deconvolution of the excitation proton pulse is the best technique for extracting protoacoustic arrival times, particularly if there is variation in the proton pulse shape.

07 ISOTOPE AND RADIATION SOURCES↗