Search NASA⌕ Search

SEARCH · Search NASA

Results for “rotating flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Simulating Wind Around Isolated Buildings with the System for Atmospheric Modeling

A method to represent the flow around obstacles such as buildings is implemented in the System for Atmospheric Modeling (SAM). The method, which we call a Quasi-Solid Box Method (QSBM), introduces a simple modification to the anelastic equations that forces the flow to stagnate within the obstacle's boundaries. The performance of the modified SAM is evaluated using CEDVAL (Compilation of Experimental Data for Validation of Microscale Dispersion Models) wind tunnel measurements of the wind and tracer dispersion around a single rectangular building. All major observed features of the flow are quite well reproduced. The dispersion of the tracer released at the building base is also simulated. The results of simulation of a flow around a cubic building rotated by 45 degrees relative to the flow, and around a building in the form of a cylinder of aspect ratio of one, are also presented.

54 ENVIRONMENTAL SCIENCES↗

Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock.

Evans, D. G.↗

Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated, as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock.

Evans, D. G.↗

Drop size distribution and air velocity measurements in air assist swirl atomizer sprays

Detailed measurements of mean drop size (SMD) and size distribution parameters have been made using a Fraunhofer diffraction particle sizing instrument in a series of sprays generated by an air assist swirl atomizer. Thirty-six different combinations of fuel and air mass flow rates were examined with liquid flow rates up to 14 lbm/hr and atomizing air flow rates up to 10 lbm/hr. Linear relationships were found between SMD and liquid to air mass flow rate ratios. SMD increased with distance downstream along the center line and also with radial distance from the axis. Increase in obscuration with distance downstream was due to an increase in number density of particles as the result of deceleration of drops and an increase in the exposed path length of the laser beam. Velocity components of the atomizing air flow field measured by a laser anemometer show swirling jet air flow fields with solid body rotation in the core and free vortex flow in the outer regions.

Mao, C.-P.↗

Experimental analysis and flow visualization of a thin liquid film on a stationary and rotating disk

The mean thickness of a thin liquid film of deionized water with a free surface on a stationary and rotating horizontal disk has been measured with a nonobtrusive capacitance technique. The measurements were taken when the rotational speed ranged from 0-300 rpm and the flow rate varied from 7.0-15.0 lpm. A flow visualization study of the thin film was also performed to determine the characteristics of the waves on the free surface. When the disk was stationary, a circular hydraulic jump was present on the disk. Upstream from the jump, the film thickness was determined by the inertial and frictional forces on the fluid, and the radial spreading of the film. The surface tension at the edge of the disk affected the film thickness downstream from the jump. For the rotating disk, the film thickness was dependent upon the inertial and frictional forces near the center of the disk and the centrifugal forces near the edge of the disk.

Thomas, S.↗

Dispersion Validation for Flow Involving a Large Structure Revisited: 45 Degree Rotation

The atmospheric dispersion of contaminants in the wake of a large urban structure is a challenging fluid mechanics problem of interest to the scientific and engineering communities. Magnetic Resonance Velocimetry (MRV) and Magnetic Resonance Concentration (MRC) are relatively new techniques that leverage diagnostic equipment used primarily by the medical field to make 3D engineering measurements of flow and contaminant dispersal. SIERRA/Fuego, a computational fluid dynamics (CFD) code at Sandia National Labs is employed to make detailed comparisons to the dataset to evaluate the quantitative and qualitative accuracy of the model. This work is the second in a series of scenarios. In the prior work, a single large building in an array of similar buildings was considered with the wind perpendicular to a building face. In this work, the geometry is rotated by 45 degrees and improved studies are performed for simulation credibility. The comparison exercise shows conditionally good comparisons between the model and experiment. Model uncertainties are assessed through parametric variations. Various methods of quantifying the accuracy between experiments and data are examined Three-dimensional analysis of accuracy is performed. The effort helped identify deficiencies in the techniques used to make these comparisons, and further methods development therefore becomes one of the main recommendations for follow-on work.

42 ENGINEERING↗

Observation of plasma deceleration at a rotational magnetopause discontinuity

This letter presents a detailed experimental analysis of the electric fields and electron flow velocities at a rotational magnetopause discontinuity. It is shown for this event that the magnetosheath plasma velocity is sharply decelerated on entry into the magnetosphere in very good agreement with a theoretical magnetohydrodynamic fit. This type of event is remarkable because the product of the electric-field vector and the Chapman-Ferraro magnetopause current is negative during the magnetopause crossing. This case represents one of two types of valid solution to the MHD boundary conditions. It differs from previously published examples of reconnective magnetopause geometries in that energy is being transferred locally from kinetic energy into electromagnetic energy at the time of these measurements.

Aggson, T. L.↗

Vibroacoustic Process Monitoring of 5-Stage Centrifugal Contactors

Vibroacoustic monitoring was investigated to aid in informing process operators with parameters regarding aqueous separation techniques. These techniques have a wide range of applications including nuclear fuel reprocessing. A small-scale solvent extraction system was set up with five magnetic drive contactors and two piston pumps to collect realistic operation. Vibration sensors were placed on three of the contactors and both pumps, and a microphone was placed near the system. Contactor rotational speed and pump flow rate were varied with known values to compare against measured vibroacoustic signatures. Spectral analysis allowed for the determination of contactor rotational speed and the ratio of organic to aqueous flow rate, an important parameter for ensuring optimal extraction. Vibration metrics such as kurtosis and crest factor provided additional details regarding individual rotational speeds and have potential in examination of faults for predictive maintenance. Overall, results indicate the capability of vibroacoustic monitoring to improve operator awareness and process outcomes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

Flow angle sensor and readout system

Sensor determines fluid flow angles by means of a simple vane that positions itself in the direction of the flow. The vane rotates a small light-reflecting disc as it moves while the readout system uses two cyclically polarized light beams.

Hansen, I. G.↗

Autorotating wings - An experimental investigation.

The autorotation of a flat plate about its spanwise axis was experimentally studied. Most of the work was done with a wing mounted in a 5 x 7 ft low-speed wind tunnel. The measurements consisted of the unsteady lift, drag, angular acceleration and the wing rotation rate. The flow pattern was very different from that over a static wing. The maximum and average lift, drag and angular acceleration were measured for Reynolds numbers from 25,000 to 250,000. The effect of applying driving and retarding torques to the wing was studied. A variety of wing configurations were tested, together with freely falling wings. For Reynolds numbers above 4000 the average lift and drag coefficients were comparable to those observed in the fixed axis tests, and it appeared that the flow pattern was similar.

Smith, E. H.↗