Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Serial crystallography using automated drop dispensing

Automated, pulsed liquid-phase sample delivery has the potential to greatly improve the efficiency of both sample and photon use at pulsed X-ray facilities. In this work, an automated drop on demand (DOD) system that accelerates sample exchange for serial femtosecond crystallography (SFX) is demonstrated. Four different protein crystal slurries were tested, and this technique is further improved here with an automatic sample-cycling system whose effectiveness was verified by the indexing results. Here, high-throughput SFX screening is shown to be possible at free-electron laser facilities with very low risk of cross contamination and minimal downtime. The development of this technique will significantly reduce sample consumption and enable structure determination of proteins that are difficult to crystallize in large quantities. This work also lays the foundation for automating sample delivery.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Countering sensor drift in x-ray micrscopy with fast and robust optimal control

In X-ray microscopy it is imperative that the relative position between the optics stage, that carries the X-ray focusing optics, and the sample stage follow a certain trajectory while either the optics or sample stage is being scanned. Main challenges in achieving this requirement include - open loop drift, environmental disturbance, measurement noise, sensor drift, and control hardware limit. The state-of-the-art in X-ray microscopy at Advanced Photon Source (APS) at Argonne National Laboratory (ANL) features an H ∞ control architecture applied to only the optics stage or both the optics and sample stage, achieving the objectives of large tracking bandwidth over 200 Hz, good positioning resolution on the order of nanometers, rejection of environmental disturbance, attenuation of measurement noise, good Xray diffraction image resolution and increased imaging bandwidth. However, an unaddressed issue in our existing robust control design is that the sensors and the fixtures that hold the sensors drift with time due to changing air temperature in the APS beamline. Since the drift of sensor itself is not measured, it affects the relative position between the focusing optics and sample resulting into imaging artifacts and reduced image resolution. In this article, we demonstrate the rejection of the sensor drift by directly measuring the displacement of the sensor with respect to the global reference frame. Both the measured sensor displacement (i.e. sensor drift) and optics stage displacement are incorporated in the H ∞ control architecture to achieve the above mentioned objectives in addition to minimal relative displacement between the optics stage and the sample stage. This will improve the Xray image resolution and reduce image artifacts.

Robust Control↗

Elevating the Quality of Space Omics Sequencing Data: Innovations and Methodologies from NASA GeneLab Sample Processing Laboratory

NASA’s GeneLab, part of the NASA Open Science Data Repository, is a space-related database that hosts a diverse range of transcriptomics, proteomics, epigenomics and genomics data. The NASA GeneLab Sample Processing Laboratory (SPL) generates omics data from biological experiments conducted aboard the International Space Station, Space Shuttle and space related ground experiments, this omics data then hosted on the GeneLab repository. Samples generated such experiments pose numerous technical challenges such as small experimental sample size, variance in dissection times, limited tissue preservation methods, prolonged storage time, and more. GeneLab SPL team had developed specialized expertise in nucleic acid extraction, library preparation and sequencing of such biological samples via extensive training and years of experience. In order to ensure data accuracy and consistency across experiments, SPL has developed standardized protocols for each species and tissue type. These protocols in conjunction with quality control metrics and data standards are crucial in generating of high-quality data. SPL protocols and standards have been developed in collaboration with the scientific community and had been made publicly available on the GeneLab portal, guaranteeing comparability of datasets across spaceflight experiments. To ensure reliability of data generation, SPL leverages cutting-edge innovations in laboratory automation for sample processing. By leveraging these state-of-the-art platforms, SPL achieves high levels of data reproducibility while significantly minimizing sources of bias and variability, especially across experiments with large numbers of samples. Over the past few years, the space biology investigator community has accessed SPL-generated data from the Open Science Data Repository for a myriad of data re-analysis and re-use studies. We observe a trend that in-house SPL-generated data consistently outperforms outsourced sequencing data in terms of technical standards, quality control metrics, timeliness of data delivery, and sequencing and reagent efficiency. Superior data generation has and will continue to enable discoveries in disease, diagnostic tools, and the biological effects of long duration spaceflight.

GeneLab↗

Elevating the Quality of Space Omics Sequencing Data: Innovations and Methodologies from NASA GeneLab Sample Processing Laboratory

NASA’s GeneLab, part of the NASA Open Science Data Repository, is a space-related database that hosts a diverse range of transcriptomics, proteomics, epigenomics and genomics data. The NASA GeneLab Sample Processing Laboratory (SPL) generates omics data from biological experiments conducted aboard the International Space Station, Space Shuttle and space related ground experiments, this omics data then hosted on the GeneLab repository. Samples generated such experiments pose numerous technical challenges such as small experimental sample size, variance in dissection times, limited tissue preservation methods, prolonged storage time, and more. GeneLab SPL team had developed specialized expertise in nucleic acid extraction, library preparation and sequencing of such biological samples via extensive training and years of experience. In order to ensure data accuracy and consistency across experiments, SPL has developed standardized protocols for each species and tissue type. These protocols in conjunction with quality control metrics and data standards are crucial in generating of high-quality data. SPL protocols and standards have been developed in collaboration with the scientific community and had been made publicly available on the GeneLab portal, guaranteeing comparability of datasets across spaceflight experiments. To ensure reliability of data generation, SPL leverages cutting-edge innovations in laboratory automation for sample processing. By leveraging these state-of-the-art platforms, SPL achieves high levels of data reproducibility while significantly minimizing sources of bias and variability, especially across experiments with large numbers of samples. Over the past few years, the space biology investigator community has accessed SPL-generated data from the Open Science Data Repository for a myriad of data re-analysis and re-use studies. We observe a trend that in-house SPL-generated data consistently outperforms outsourced sequencing data in terms of technical standards, quality control metrics, timeliness of data delivery, and sequencing and reagent efficiency. Superior data generation has and will continue to enable discoveries in disease, diagnostic tools, and the biological effects of long duration spaceflight.

GeneLab↗

Remotely Controlled Mixers for Light Microscopy Module (LMM) Colloid Samples

Developed by NASA Glenn Research Center, the LMM aboard the International Space Station (ISS) is enabling multiple biomedical science experiments. Techshot, Inc., has developed a series of colloid specialty cell systems (C-SPECS) for use in the colloid science experiment module on the LMM. These low-volume mixing devices will enable uniform particle density and remotely controlled repetition of LMM colloid experiments. By automating the experiment process, C-SPECS allow colloid samples to be processed more quickly. In addition, C-SPECS will minimize the time the crew will need to spend on colloid experiments as well as eliminate the need for multiple and costly colloid samples, which are expended after a single examination. This high-throughput capability will lead to more efficient and productive use of the LMM. As commercial launch vehicles begin routine visits to the ISS, C-SPECS could become a significant means to process larger quantities of high-value materials for commercial customers.

Kurk, Michael A. (Andy)↗

OSIRIS-REx: Curating Samples from the Carbon rich Asteroid Bennu

The OSIRIS REx mission returned 121 g of pristine material from the asteroid Bennu. This talk will describe the how the sample was collected, returned to earth, retrieved, and how it is currently being curated at the NASA Johnson Space Center. In order to keep the samples pristine they are kept under an ultra pure nitrogen atomosphere inside and ISO 5 equivalent clean room. Special care is taken not to expose the samples to oxygen, or organic contaminants. NASA has implemented additional procedures to minimize the likelihood of biological contamination. The presentation will also include a brief description of the preliminary results from initial study of the samples.

Aaron B. Regberg↗

Atom Probe Tomography for understanding microstructural and chemical changes in nuclear materials

Atom Probe Tomography (APT) is routinely employed to determine 3D microstructure and chemistry changes in structural materials used in reactor to understand irradiation effect. These findings help to correlate changes to mechanical and physical properties of nuclear materials which are subjected to extreme reactor conditions. With safety and economics of a reactor in mind, it is essential to be able to predict the changes in the fuel composition and microstructure as a function of burnup. Also, there is current need to develop advanced fuels with improved properties and performance which requires the experimental data on changes in microstructure, physical and chemical properties after irradiation for feedback process. A novel approach is presented to determine the local burnup in irradiated fuels using isotopic quantification obtained by Atom Probe Tomography (APT). Considering the volume of sample used (<100?µm3) for APT experiments using the lift-out process in a scanning electron microscope equipped with a Focused Ion Beam (FIB), the presented method determines the local burnup from a nuclear fuel, where a minimal amount of waste is produced. In this work, three samples were analyzed with different burnup conditions to quantify the isotopes of 235U, 236U, and 238U for burnup calculation in the irradiated metallic U–7Mo dispersion fuel. The calculated values were found in excellent agreement with MCNP calculations. With regard to structural materials, one of the primary factors limiting the utilization of fuel rods of Zr alloys is hydrogen pick up during oxidation. Past experimental studies have shown that the hydrogen pickup in Zirconium alloys is influenced by the alloy composition as well by irradiation temperature and neutron dose. Oftentimes, it is not feasible to carry out comprehensive studies on understanding the microstructural evolution in neutron irradiated materials since in reactor irradiation programs are extremely costly, lengthy and logistically complicated. The use of ion irradiation as a substitute has grown in recent years for several reasons including less radioactivity, faster irradiations and lower costs. In the framework of the MUZIC 3 project, samples of Zircaloy-4 have been proton and Zr2+ irradiated at the Michigan Ion Beam Lab (MIBL) facility with aim to create a microstructure that is similar to that observed after in-reactor service. The temperature of the environment is adjusted to compensate for the higher dose rate, as has been done previously. As a first step in this project the irradiated microstructures have been characterized using Transmission Electron Microscopy and Atom Probe Tomography to elucidate the microstructural changes, including precipitate amorphization and dissolution and the formation of dislocation loops. This presentation plans to highlight initial finding of this project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An environmental sample chamber for reliable scanning transmission x-ray microscopy measurements under water vapor

We have designed, fabricated, and tested a compact gas-phase reactor for performing in situ soft x-ray scanning transmission x-ray microscopy (STXM) measurements. The reactor accommodates many gas atmospheres, including reactive or corrosive gasses, but was designed specically to address the needs of measurements under water vapor. An on-board sensor measures the relative humidity and temperature inside the reactor, minimizing uncertainties associated with measuring these quantities outside the instrument. The reactor mounts directly to the existing sample holder used in the majority of STXM instruments around the world and installs with minimal instrument reconguration. Using the reactor contributes over 85% less additional absorption compared to lling the STXM chamber with process gas, and results in much more stable imaging conditions. The reactor is in use at the STXM instruments at beamlines 11.0.2 and 5.3.2.2 at the Advanced Light Source.

Environmental Molecular Sciences Laboratory↗

A novel approach to determine the local burnup in irradiated fuels using Atom Probe Tomography (APT)

A novel approach is presented to determine the local burnup in irradiated fuels using isotopic quantification obtained by Atom Probe Tomography (APT). Considering the volume of sample used (<100 μm 3 ) for APT experiments using the lift-out process in a scanning electron microscope equipped with a Focused Ion Beam (FIB), the presented method determines the local burnup from a nuclear fuel, where a minimal amount of waste is produced. In this work, three samples were analyzed with different burnup conditions: as received low enriched 19.8% U-235, intermediate burnup (~52% U-235 fissioned) and high burnup (~69% U-235 fissioned) U–Mo fuel. APT is used to quantify the isotopes of 235 U, 236 U, 238 U, 239 Pu and 237 Np for burnup calculation in the irradiated metallic U–7Mo dispersion fuel. The equation used to estimate the burnup of fuels is derived by considering that the initial counts of U is equal to the sum of remaining atoms of U isotopes and all the U reactions undergone during irradiation. Here, this method provides U enrichment and local burnup with an unprecedented high spatial resolution based on quantification of isotopic ratios of U.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A high pressure cell for supercritical CO{sub 2} on-line chemical reactions studied with x-ray techniques

A versatile high pressure X-ray sample cell has been developed for conducting in situ time-resolved X-ray scattering experiments in the pressure and temperature regime required (pressures up to 210 bars and temperatures up to 120 °C) for chemical reactions in supercritical fluids. The large exit opening angle of the cell allows simultaneous performance of SAXS-WAXS experiments. Diamond windows are used in order to benefit from the combination of maximum strength, minimal X-ray absorption and chemical inertia. The sample cell can also be utilised for X-ray spectroscopy experiments over a wide range of photon energies. Results of the online synthesis of a block copolymer, poly(methyl methacrylate-block-poly(benzyl methacrylate), by Reversible Addition-Fragmentation Chain Transfer (RAFT) in a supercritical CO{sub 2} dispersion polymerisation will be discussed. The contribution of the density fluctuations, as function of temperature, to the X-ray scattering signal has been quantified in order to allow appropriate background subtractions.

36 MATERIALS SCIENCE↗

Development of field-based separations for the rapid identification of uranium and plutonium

The development of rapid, radioanalytical techniques to separate uranium and plutonium from complex, field samples are needed for the timely and accurate determination of nuclear material origin, and processing activities. Widespread use of nuclear power and technology in the world has increased demands on analytical laboratories from the monitoring of numerous low-level, environmental samples with variable compositions. Environmental sampling has proven to be one of the strongest technical measures for detecting nuclear material and activities. With the increase in sampling demands, new technologies must offer improvements such as automation, high throughput, reproducible chemical separations, short analysis times, and reduced costs to be effective. We have been developing a portable, separations system for uranium (U) and plutonium (Pu) separations based upon selective extraction of target elements using an extraction chromatographic resin which would allow for simple and fast identifcation when coupled with the appropriate sample digestor and detection systems. The microfluidic design minimizes elution volumes and concentrates the elements of interest in a purified stream. Flowsheet development and testing was demonstrated on a single, micro-column system with an acidified, iron, uranium, and plutonium nitrate stream. The recovery of Pu was optimized by examining various reducing agents at different concentrations for rapid, quantitative recovery from the flow-through design. Quantitative recovery and high selectivity of U and Pu was achieved in the appropriate stripping stages and provided purified and concentrated U and Pu streams. The microfluidic system suggests automation in a small, footprint unit while exploiting the in-line processing of extraction chromatographic resins as the primary means of concentrating the radionuclides from the raw acidic feed and separating the elements into purified streams.

Extraction Chromatography↗

Coherent J/ψ photoproduction at forward rapidity in ultra-peripheral Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The ALICE collaboration performed the first rapidity-differential measurement of coherent J/ψ photoproduction in ultra-peripheral Pb–Pb collisions at a center-of-mass energy $ \sqrt{s_{NN}}$=5.02 TeV. The J/ψ is detected via its dimuon decay in the forward rapidity region (-4.0 < γ < -2.5) for events where the hadronic activity is required to be minimal. The analysis is based on an event sample corresponding to an integrated luminosity of about 750 μb -1 . The cross section for coherent J/ψ production is presented in six rapidity bins. The results are compared with theoretical models for coherent J/ψ photoproduction. These comparisons indicate that gluon shadowing effects play a role in the photoproduction process. The ratio of ψ' to J/ψ coherent photoproduction cross sections was measured and found to be consistent with that measured for photoproduction off protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Basic properties of eutectic chloride salts NaCl-KCl-ZnCl 2 and NaCl-KCl-MgCl 2 as HTFs and thermal storage media measured using simultaneous DSC-TGA

Concentrated solar power (CSP) technologies tend to work at high temperatures for better energy efficiency, which need high temperature heat transfer fluids (HTF) and thermal storage. A good HTF should have low melting point and be thermally stable at high temperatures. A thermal storage medium needs a high heat capacity in order to store more energy in per unit of mass or volume. The objective of this work is to study the basic thermophysical properties of several eutectic molten salts for HTF and thermal storage media, which can work at upper limit temperatures of 850 °C. The eutectic salts are mixtures by NaCl-KCl-ZnCl 2 , and by NaCl-KCl-MgCl 2 , respectively. The heat capacity, melting point, and heat of fusion of the eutectic salts at different temperatures were measured using Differential Scanning Calorimetry (DSC) and Thermal Gravimetric Analysis (TGA) simultaneously. Details of the measurements and obtained experience of operating the equipment are provided in the work. For each of the eutectic salts multiple samples were tested to check repeatability and to minimize random errors. Finally, in theoretical analysis, mixing rules from literature was used to estimate the heat capacity of the new HTFs, which showed good agreement with experimental data.

14 SOLAR ENERGY↗

Electrochemical properties of poly(ethylene oxide) electrolytes above the entanglement threshold

The ion transport in electrolytes depends on three transport coefficients, conductivity (κ), salt diffusion coefficient (D), and the cation transference number with respect to the solvent velocity ($t_+^0$), and the thermodynamic factor ($T_f$). Current methods for determining these parameters involve four separate experiments, and the coupled nature of the equations used to determine them generally results in large experimental uncertainty. We present data obtained from 64 independent polymer electrolytes comprising poly(ethylene oxide) (PEO) and lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) salt. The molecular weights of PEO ranged from 5 to 275 kg mol -1 ; these samples are all above the entanglement threshold. We minimize the experimental uncertainty in transport and thermodynamic measurements by exploiting the fact that ion transport in entangled polymer electrolytes should be independent of molecular weight. The dependence of $κ, D, t_+^0$, and $T_f$ as a function of salt concentration in the range 0.035 ≤ r ≤ 0.30 are presented with a 95% confidence interval, where r is the molar ratio of lithium ions to ethylene oxide monomer units. While κ, D, and $T_f$ are all positive as required by thermodynamic constraints, there is no constraint on the sign of $t_+^0$. We find that $t_+^0$ is negative in the salt concentration range of 0.093 ≤ r ≤ 0.189.

25 ENERGY STORAGE↗

Effect of Al 2 O 3 coating on fretting wear performance of Zr alloy

Fretting wear caused by flow-induced vibration (FIV) is one of the predominant tribological failure modes in nuclear power plants and industry. This paper presents an experimental study of the effect on fretting performance of alumina (Al 2 O 3 ) coatings produced by atomic layer deposition (ALD) on Zirlo (a Zr alloy), a common nuclear fuel cladding alloy. A coating with uniform thickness of about 750 nm was deposited onto a Zirlo flat. Because the typical thickness of fuel cladding is 1 mm, an ultra-thin coating is required. The hardness and elastic modulus of the ALD coating were measured by nano-indentation techniques. With a pin-on-flat contact configuration in low-amplitude reciprocating contact, fretting performance was measured for uncoated Zirlo, Al2O 3 -coated Zirlo, and Al 2 O 3 -coated Zirlo followed by heat treatment. Results showed that the as-deposited Al 2 O 3 coating provided slight improvement in fretting wear performance. However, the heat-treated coating showed two orders of magnitude reduction in fretting wear of the Zr alloy. Wear in the uncoated material involves some local plastic deformation and debris accumulation at the contact interface. In the Al 2 O 3 -coated material, wear occurred by transfer of transparent Al 2 O 3 oxide into the steel pin counterface. Localized removal of coating from the Zirlo alloy flat resulted in a “shark whale” pattern in a scanning electron microscopy image. There was minimal debris accumulation with the heat-treated sample.

36 MATERIALS SCIENCE↗

A shock tube with a high-repetition-rate time-of-flight mass spectrometer for investigations of complex reaction systems

A conventional membrane-type stainless steel shock tube has been coupled to a high-repetition-rate time-of-flight mass spectrometer (HRR-TOF-MS) to be used to study complex reaction systems such as the formation of pollutants in combustion processes or formation of nanoparticles from metal containing organic compounds. Opposed to other TOF-MS shock tubes, our instrument is equipped with a modular sampling unit that allows to sample with or without a skimmer. The skimmer unit can be mounted or removed in less than 10 min. Thus, it is possible to adjust the sampling procedure, namely, the mass flux into the ionization chamber of the HRR-TOF-MS, to the experimental situation imposed by species-specific ionization cross sections and vapor pressures. The whole sampling section was optimized with respect to a minimal distance between the nozzle tip inside the shock tube and the ion source inside the TOF-MS. The design of the apparatus is presented and the influence of the skimmer on the measured spectra is demonstrated by comparing data from both operation modes for conditions typical for chemical kinetics experiments. The well-studied thermal decomposition of acetylene has been used as a test system to validate the new setup against kinetics mechanisms reported in literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of bulk FeHfBO soft magnetic materials and its loss characterization at megahertz frequency

Magnetic core materials with low loss, high saturation magnetization, large permeability, and operating frequency above 1 MHz are in high demands for the next generation of miniaturized power electronics. Amorphous FeHfB ribbons with thickness around 20 {mu}m have been fabricated through melt-spinning. Different heat treatments were performed on the FeHfB ribbons, and the relations among heat treatments, microstructure, and magnetic properties have been explored. Properties such as coercivity (H{sub c}) of 2.0 Oe and saturation magnetic flux density (B{sub S}) of 1.2 T have been achieved in samples with exchange coupling. The losses can be minimized by balancing the hysteretic and eddy current losses and can be further reduced with additional magnetic field annealing. At 5 MHz with peak magnetic flux density of 20 mT, the materials show core losses comparable to the best ferrites, but with higher permeability value of about 200 and superior saturation induction of more than 1 T.

36 MATERIALS SCIENCE↗

Equation of state of rhenium and application for ultra high pressure calibration

The isothermal equation of state of rhenium has been measured by powder X-ray diffraction experiments up to 144 GPa at room temperature in a diamond anvil cell. A helium pressure transmitting medium was used to minimize the non-hydrostatic stress on the sample. The fit of pressure-volume data yields a bulk modulus K{sub 0} = 352.6 GPa and a pressure derivative of the bulk modulus K′{sub 0}=4.56. This equation of state differs significantly from a recent determination [Dubrovinsky et al., Nat. Commun. 3, 1163 (2012)], giving here a lower pressure at a given volume. The possibility of using rhenium gasket X-ray diffraction signal, with the present equation of state, to evaluate multi-Mbar pressures in the chamber of diamond anvil cells is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗