Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Group contribution methodology based on the statistical associating fluid theory for heteronuclear molecules formed from Mie segments

A generalization of the recent version of the statistical associating fluid theory for variable range Mie potentials [Lafitte et al., J. Chem. Phys. 139, 154504 (2013)] is formulated within the framework of a group contribution approach (SAFT-γ Mie). Molecules are represented as comprising distinct functional (chemical) groups based on a fused heteronuclear molecular model, where the interactions between segments are described with the Mie (generalized Lennard-Jonesium) potential of variable attractive and repulsive range. A key feature of the new theory is the accurate description of the monomeric group-group interactions by application of a high-temperature perturbation expansion up to third order. The capabilities of the SAFT-γ Mie approach are exemplified by studying the thermodynamic properties of two chemical families, the n-alkanes and the n-alkyl esters, by developing parameters for the methyl, methylene, and carboxylate functional groups (CH{sub 3}, CH{sub 2}, and COO). The approach is shown to describe accurately the fluid-phase behavior of the compounds considered with absolute average deviations of 1.20% and 0.42% for the vapor pressure and saturated liquid density, respectively, which represents a clear improvement over other existing SAFT-based group contribution approaches. The use of Mie potentials to describe the group-group interaction is shown to allow accurate simultaneous descriptions of the fluid-phase behavior and second-order thermodynamic derivative properties of the pure fluids based on a single set of group parameters. Furthermore, the application of the perturbation expansion to third order for the description of the reference monomeric fluid improves the predictions of the theory for the fluid-phase behavior of pure components in the near-critical region. The predictive capabilities of the approach stem from its formulation within a group-contribution formalism: predictions of the fluid-phase behavior and thermodynamic derivative properties of compounds not included in the development of group parameters are demonstrated. The performance of the theory is also critically assessed with predictions of the fluid-phase behavior (vapor-liquid and liquid-liquid equilibria) and excess thermodynamic properties of a variety of binary mixtures, including polymer solutions, where very good agreement with the experimental data is seen, without the need for adjustable mixture parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Axis switching and spreading of an asymmetric jet: Role of vorticity dynamics

The effects of vortex generators and periodic excitation on vorticity dynamics and the phenomenon of axis switching in a free asymmetric jet are studied experimentally. Most of the data reported are for a 3:1 rectangular jet at a Reynolds number of 450,000 and a Mach number of 0.31. The vortex generators are in the form of 'delta tabs', triangular shaped protrusions into the flow, placed at the nozzle exit. With suitable placement of the tabs, axis switching could be either stopped or augmented. Two mechanisms are identified governing the phenomenon. One, as described by previous researchers and referred to here as the omega(sub theta)-induced dynamics, is due to difference in induced velocities for different segments of a rolled up azimuthal vortical structure. The other, omega(sub x)-induced dynamics, is due to the induced velocities of streamwise vortex pairs in the flow. Both dynamics can be active in a natural asymmetric jet; the tendency for axis switching caused by the omega(sub theta)-induced dynamics may be, depending on the streamwise vorticity distribution, either resisted or enhanced by the omega(sub x)-induced dynamics. While this simple framework qualitatively explains the various observations made on axis switching, mechanisms actually in play may be much more complex. The two dynamics are not independent as the flow field is replete with both azimuthal and streamwise vortical structures which continually interact. Phase averaged flow field data for a periodically forced case, over a volume of the flow field, are presented and discussed in an effort to gain insight into the dynamics of these vortical structures.

Zaman, K. B. M. Q.↗

Method for Cleanly and Precisely Breaking Off a Rock Core Using a Radial Compressive Force

The Mars Sample Return mission has the goal to drill, break off, and retain rock core samples. After some results gained from rock core mechanics testing, the realization that scoring teeth would cleanly break off the core after only a few millimeters of penetration, and noting that rocks are weak in tension, the idea was developed to use symmetric wedging teeth in compression to weaken and then break the core at the contact plane. This concept was developed as a response to the break-off and retention requirements. The wedges wrap around the estimated average diameter of the core to get as many contact locations as possible, and are then pushed inward, radially, through the core towards one another. This starts a crack and begins to apply opposing forces inside the core to propagate the crack across the plane of contact. The advantage is in the simplicity. Only two teeth are needed to break five varieties of Mars-like rock cores with limited penetration and reasonable forces. Its major advantage is that it does not require any length of rock to be attached to the parent in order to break the core at the desired location. Test data shows that some rocks break off on their own into segments or break off into discs. This idea would grab and retain a disc, push some discs upward and others out, or grab a segment, break it at the contact plane, and retain the portion inside of the device. It also does this with few moving parts in a simple, space-efficient design. This discovery could be implemented into a coring drill bit to precisely break off and retain any size rock core.

Richardson, Megan↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

Development and evaluation of an efficient approach to volumetric arc therapy planning

An efficient method for volumetric intensity modulated arc therapy (VMAT) planning was developed, where a single arc (360 deg. or less) is delivered under continuous variation of multileaf collimator (MLC) segments, dose rate, and gantry speed. Plans can be generated for any current linear accelerator that supports these degrees of freedom. MLC segments are derived from fluence maps at relatively coarsely sampled angular positions. The beam segments, dose rate, and gantry speed are then optimized using direct machine parameter optimization based on dose volume objectives and leaf motion constraints to minimize arc delivery time. The method can vary both dose rate and gantry speed or alternatively determine the optimal plan at constant dose rate and gantry speed. The method was used to retrospectively generate variable dose rate VMAT plans to ten patients (head and neck, prostate, brain, lung, and tonsil). In comparison to step-and-shoot intensity modulated radiation therapy, dosimetric plan quality was comparable or improved, estimated delivery times ranged from 70 to 160 s, and monitor units were consistently reduced in nine out of the ten cases by an average of {approx}6%. Optimization and final dose calculation took between 5 and 35 min depending on plan complexity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Growth from Solutions: Kink dynamics, Stoichiometry, Face Kinetics and stability in turbulent flow

1. Kink dynamics. The first segment of a polygomized dislocation spiral step measured by AFM demonstrates up to 60% scattering in the critical length l*- the length when the segment starts to propagate. On orthorhombic lysozyme, this length is shorter than that the observed interkink distance. Step energy from the critical segment length based on the Gibbs-Thomson law (GTL), l* = 20(omega)alpha/(Delta)mu is several times larger than the energy from 2D nucleation rate. Here o is tine building block specific voiume, a is the step riser specific free energy, Delta(mu) is the crystallization driving force. These new data support our earlier assumption that the classical Frenkel, Burton -Cabrera-Frank concept of the abundant kink supply by fluctuations is not applicable for strongly polygonized steps. Step rate measurements on brushite confirms that statement. This is the1D nucleation of kinks that control step propagation. The GTL is valid only if l* <Dk/vk, the diffusion path of a kink that has diffusivity Dk and average growth velocity vk. This is equivalent to supersaturations sigma less than approx. alpha/2l*, where alpha is the building block size. For lysozyme, sigma much less than (1%). Conventionally used interstep distance generated by screw dislocation, 19(omega)alpha/Delta(mu) should be replaced by the very different real one, approx.4l*. 2. Stoichiometry. Kink, and thus step and face rates of a non-Kossel complex molecular monocomponent or any binary, AB, lattice was found theoretically to be proportional to 1/(zeta(sup 1/2) + zeta(sup - 1/2)), where zeta = [B]/[A] is the stoichiometry ratio in solution. The velocities reach maxima at zeta = 1. AFM studies of step rates on CaOxalate monohydrate (kidney stones) from aqueous solution was found to obey the law mentioned above. Generalization for more complex lattice will be discussed. 3. Turbulence. In agreement with theory, high precision in-situ laser interferometry of the (101) KDP crystal face shows step bunching if solution flows parallel to the step flow. The bunch height increases with the distance the bunch travels, i.e. with the face size. However, when the flow rate, u, increases, at u greater than approx. 1 m / s , the average step bunch height decreases as 1/u. The pheonomenon is attributed to the turbulent rather than laminar viscous boundary layer where diffusivity Dt = 0.5u(sub tau),y, i.e. increases linearly with the distance y from the solid face. Friction velocity, u(sub tau) approx. u(sup 7/8). Dramatically larger rate of the mass/heat transport within the turbulent, as compared to the laminar, viscous layer will be discussed.

Chernov, A. A.↗

MO-DE-BRA-01: Flipped Physics Courses Within a Radiologic Technologist Program: Video Production and Long Term Outcomes

Purpose: To determine if the flipped class format has an effect on examination results for a radiologic technologist (RT) program and discuss benefits from creating video resources. Methods: From 2001–2015, students had taken both a radiological physics and quality control (QC) class as a part of their didactic training. In 2005/2006, the creation of videos of didactic lectures and QC test demonstrations allowed for a flip where content was studied at home while exercises and reviews were done in-class. Final examinations were retrospectively reviewed from this timeframe. 12 multiple choice physics questions (MCP) and 5 short answer QC questions (SAQC) were common to pre and post flip exams. The RT program’s ARRT exam scores were also obtained and compared to national averages. Results: In total, 36 lecture videos and 65 quality control videos were created for the flipped content. Data was ∼2.4GB and distributed to students via USB or CD media. For MCP questions, scores improved by 7.9% with the flipped format and significance (Student’s t-test, p<0.05) was found for 3 of the 12 questions. SAQC questions showed improvement by 14.6% and significance was found for 2 of the 5 questions. Student enrollment increased from ∼14 (2001–2004) to ∼23 students (2005–15). Content was continuously added post-flip due to the efficiency of delivery. The QC class in 2003 covered 45 test setups in-class while 65 were covered with video segments in 2014. Flipped materials are currently being repurposed. In 2015, this video content was restructured into an ARRT exam review guide and in 2016, the content was reorganized for fluoroscopy training for physicians. Conclusion: We believe that flipped classes can improve efficiency of content delivery and improve student performance even with an increase in class size. This format allows for flexibility in learning as well as re-use in multiple applications.

07 ISOTOPE AND RADIATION SOURCES↗

WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absorption and scattering of laser radiation by the diffusion flame of aviation kerosene

The absorption coefficient of the radiation of a repetitively pulsed Nd : YAG laser with an average output power up to 6 W and of a cw ytterbium optical fibre laser with an output power up to 3 kW was measured in the diffusion flame of aviation kerosene burning on a free surface in the atmospheric air. The absorption coefficient as a function of flame length, radiation power, and radiation intensity, which was varied in the {approx}10{sup 3} - 5 Multiplication-Sign 10{sup 4} W cm{sup -2} range, was obtained for two distances (1 and 2 cm) between the laser beam axis and the surface. The coefficient of radiation absorption by kerosene flame was compared with that in ethanol and kerosene - ethanol mixture flames. The radiation power scattered by a small segment of the kerosene flame irradiated by Nd : YAG laser radiation was measured as a function of longitudinal and azimuthal coordinates. An estimate was made of the total scattered radiation power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-139: Dynamic Conformal Arcs Vs. VMAT for Stereotactic Lung Target Treatment Planning

Purpose: To investigate if Dynamic Conformal Arcs (DCA) can be used to achieve similar target coverage and conformality as that of using VMAT for Stereotactic Body Radiation Therapy (SBRT) for Lung cases. Methods: We retrospectively re-planned 11 patients that were treated with SBRT for lung tumors using only a single conformal arc, broken into three or four arc segments and weighted differentially in order to achieve the dosimetric constraints as outlined in RTOG 0915 protocol. These re-plans of using DCA were compared with those of using VMAT in terms of the Planning Tumor Volume (PTV) coverage goals, Maximum Dose 2 cm away (D {sub 2}cm), High Dose Spillage, Intermediate Dose Spillage, Lung volume getting 5 Gy (V{sub 5}), and number of monitor units (MU). Results: Of the 11 cases, only three DCA plans failed the D{sub 2}cm parameter, and one VMAT plan failed. None of the 11 patients failed the High Dose Spillage in either technique. For Intermediate Dose Spillage, one DCA plan failed and none failed for VMAT plans. The average V{sub 5} for DCA was 10.5 percent, with VMAT reporting 11.7 percent. The average number of MU for DCA and VMAT were 2605 and 3451, respectively. Conclusion: DCA is able to achieve very similar treatment planning goals as that of using VMAT in treating SBRT Lung tumors in most cases with simplicity. In addition, the DCA technique produces an acceptable plan with lower V{sub 5} in less MU when dose to OAR concerns are at minimum. However, DCA has shown its limitations when the target is close to multiple OAR.

60 APPLIED LIFE SCIENCES↗

SU-C-213-01: 3D Printed Patient Specific Phantom Composed of Bone and Soft Tissue Substitute Plastics for Radiation Therapy

Purpose: 3D printed phantoms constructed of multiple tissue approximating materials could be useful in both clinical and research aspects of radiotherapy. This work describes a 3D printed phantom constructed with tissue substitute plastics for both bone and soft tissue; air cavities were included as well. Methods: 3D models of an anonymized nasopharynx patient were generated for air cavities, soft tissues, and bone, which were segmented by Hounsfield Unit (HU) thresholds. HU thresholds were chosen to define air-to-soft tissue boundaries of 0.65 g/cc and soft tissue-to-bone boundaries of 1.18 g/cc based on clinical HU to density tables. After evaluation of several composite plastics, a bone tissue substitute was identified as an acceptable material for typical radiotherapy x-ray energies, composed of iron and PLA plastic. PET plastic was determined to be an acceptable soft tissue substitute. 3D printing was performed on a consumer grade dual extrusion fused deposition model 3D printer. Results: MVCT scans of the 3D printed heterogeneous phantom were acquired. Rigid image registration of the patient and the 3D printed phantom scans was performed. The average physical density of the soft tissue and bone regions was 1.02 ± 0.08 g/cc and 1.39 ± 0.14 g/cc, respectively, for the patient kVCT scan. In the 3D printed phantom MVCT scan, the average density of the soft tissue and bone was 1.01 ± 0.09 g/cc and 1.44 ± 0.12 g/cc, respectively. Conclusion: A patient specific phantom, constructed of heterogeneous tissue substitute materials was constructed by 3D printing. MVCT of the 3D printed phantom showed realistic tissue densities were recreated by the 3D printing materials. Funding provided by intra-department grant by University of Minnesota Department of Radiation Oncology.

60 APPLIED LIFE SCIENCES↗

Correlated Changes in Retinal Thickness and Visuomotor Function in Asymptomatic Plaquenil Toxicity Patients

We have previously shown that a 5-minute eye-movement test can capture a number of largely independent “oculometric” parameters of human visual/visuomotor function (Liston & Stone, 2014). This test has been successfully used to characterize mild neural impairment due to traumatic brain injury, sleep and circadian disruption, and alcohol consumption (Liston et al., 2017; Stone et al, 2019; Tyson et al, 2021). Here, we extend this approach to study patients at risk of progressive posterior-segment illness to see how oculometrics relate to standard clinical ophthalmological measures. Five female patients (<20:40 BCVA, 34-60 years old) undergoing hydroxychloroquine treatment (2-7mg/kg/day for 10-23 years for rheumatologic illness) have participated thus far. Under monocular viewing conditions in randomized order, they tracked a moving spot undergoing radial step-ramp motion in one of 90 randomized directions, at one of 5 randomized speeds, starting at random times (for details, see Stone et al, 2019). We computed nine independent oculometrics (latency, initial acceleration, steady-state gain, proportion smooth, saccadic rate, saccadic amplitude, direction noise, speed responsiveness, and speed noise). Spectral-domain optical coherence tomography (Zeiss, Dublin, CA) was used to measure the average thickness of the nine Early Treatment Diabetic Retinopathy Study macular sectors from the internal limiting membrane to the retinal pigmented epithelium. We used Pearson’s correlation between retinal thickness and our oculometrics with t-statistics to test separate one-sided hypotheses across 10 retinae. Our preliminary analysis found significant changes in several different aspects of visuomotor performance. Most notably, latency increased, initial acceleration decreased, and steady-state pursuit gain decreased as retinal thickness decreased (r2 = 0.364, 0.579, and 0.692; one-tailed P = 0.032, 0.005, and 0.001, respectively). Speed responsiveness appeared to decrease, but this effect was marginal for our current sample (r2 = 0.253, P = 0.069). Lastly, direction discrimination and saccadic behavior appeared unchanged. We conclude that oculometrics may provide sensitive measures of changes in retinal thickness. More importantly, oculometrics have the potential to detect impairment before it becomes evident with standard clinical imaging tools, while also providing insight into the behavioral implications of any resulting deficits in visual/visuomotor function.

eye movements↗

MO-AB-BRA-05: [18F]NaF PET/CT Imaging Biomarkers in Metastatic Prostate Cancer

Purpose: Clinical use of {sup 18}F-Sodium Fluoride (NaF) PET/CT in metastatic settings often lacks technology to quantitatively measure full disease dynamics due to high tumor burden. This study assesses radiomics-based extraction of NaF PET/CT measures, including global metrics of overall burden and local metrics of disease heterogeneity, in metastatic prostate cancer for correlation to clinical outcomes. Methods: Fifty-six metastatic Castrate-Resistant Prostate Cancer (mCRPC) patients had NaF PET/CT scans performed at baseline and three cycles into chemotherapy (N=16) or androgen-receptor (AR) inhibitors (N=39). A novel technology, Quantitative Total Bone Imaging (QTBI), was used for analysis. Employing hybrid PET/CT segmentation and articulated skeletal-registration, QTBI allows for response assessment of individual lesions. Various SUV metrics were extracted from each lesion (iSUV). Global metrics were extracted from composite lesion-level statistics for each patient (pSUV). Proportion of detected lesions and those with significant response (%-increase or %-decrease) was calculated for each patient based on test-retest limits for iSUV metrics. Cox proportional hazard regression analyses were conducted between imaging metrics and progression-free survival (PFS). Results: Functional burden (pSUV{sub total}) assessed mid-treatment was the strongest univariate predictor of PFS (HR=2.03; p<0.0001). Various global metrics outperformed baseline clinical markers, including fraction of skeletal burden, mean uptake (pSUV{sub mean}), and heterogeneity of average lesion uptake (pSUV{sub hetero}). Of 43 patients with paired baseline/mid-treatment imaging, 40 showed heterogeneity in lesion-level response, containing populations of lesions with both increasing/decreasing metrics. Proportion of lesions with significantly increasing iSUV{sub mean} was highly predictive of clinical PFS (HR=2.0; p=0.0002). Patients exhibiting higher proportion of lesions with decreasing iSUV{sub total} saw prolonged radiographic PFS (HR=0.51; p=0.02). Conclusion: Technology presented here provides comprehensive disease quantification on NaF PET/CT imaging, showing strong correlation to clinical outcomes. Total functional burden as well as proportions of similarly responding lesions was predictive of PFS. This supports ongoing development of NaF PET/CT based imaging biomarkers in mCRPC. Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

AOPA Survey Summary of AGATE Concepts Demonstration October 17-19, 1996: Basic Report - Volume 1

An AGATE Concepts Demonstration was conducted at the Annual Aircraft Owners and Pilots Association (AOPA) Convention in 1996. The demonstration consisted of an interactive simulation of a single-pilot, single-engine aircraft in which the participant took off, flew a brief enroute segment and then flew a Global Positioning System (GPS) approach and landing. The participant was provided an advanced 'pathway-in-the-sky' presentation on both a head-up display and a head-down display to follow throughout the flight. A single lever power control and display concept was also provided for control of the engine throughout the flight. A second head-down, multifunction display in the instrument panel provided a moving map display for navigation purposes and monitoring of the status of the aircraft's systems. An estimated 352 people observed or participated in the demonstration, and 144 surveys were collected. The pilot ratings of the participants ranged from student to Air Transport Rating with an average of 1850 hours total flight time. The performance of the participants was surprisingly good, considering the minimal training in a completely new system concept. The overwhelming response was that technologies that simplify piloting tasks are enthusiastically welcomed by pilots of all experience levels. The increase in situation awareness and reduction in pilot workload were universally accepted and lauded as steps in the right direction.

Source record↗

AOPA Survey Summary of AGATE Concepts Demonstration, October 17-19, 1996: Original Survey Data - Volume 2

An AGATE Concepts Demonstration was conducted at the Annual Aircraft Owners and Pilots Association (AOPA) Convention in 1996. The demonstration consisted of an interactive simulation of a single-pilot, single-engine aircraft in which the participant took off, flew a brief enroute segment and then flew a Global Positioning System (GPS) approach and landing. The participant was provided an advanced 'pathway-in-the-sky' presentation on both a head-up display and a head-down display to follow throughout the flight. A single lever power control and display concept was also provided for control of the engine throughout the flight A second head-down, multifunction display in the instrument panel provided a moving map display for navigation purposes and monitoring of the status of the aircraft's systems. An estimated 352 people observed or participated in the demonstration, and 144 surveys were collected. The pilot ratings of the participants ranged from student to Air Transport Rating with an average of 1850 hours total flight time. The performance of the participants was surprisingly good, considering the minimal training in a completely new system concept. The overwhelming response was that technologies that simplify piloting tasks are enthusiastically welcomed by pilots of all experience levels. The increase in situation awareness and reduction in pilot workload were universally accepted and lauded as steps in the right direction.

Source record↗

Automated Parameterized CFD Simulations of Phase-Change Material Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers is typically computationally intensive due to the relative complex time-dependent underlying physics. This paper presents a study investigating a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 37oC nominal melting temperature, leveraging automated parametric CFD simulations. The computational domain is reduced to 2D axisymmetric for a segment of the HX comprising a region in between two fins with constant wall temperature as boundary condition. This approach allows for faster evaluations of the transient thermal characteristics for a given design space of interest. Correlations and reduced order models (ROM’s) are developed. Results indicate that the ROM’s reproduce the CFD simulations with high accuracy for designs from the training data set, however, designs from cross-validation and test sets do not always have good agreement. The limited number of designs in the training set is a possible cause for the lack of robustness of the ROM’s and thus additional training designs will be added in future work. The ROM’s solve the simulations on average 500,000 times faster than CFD.

25 ENERGY STORAGE↗

The Combined Influence of Molecular Weight and Temperature on the Aging and Viscoelastic Response of a Glassy Thermoplastic Polyimide

The effect of molecular weight on the viscoelastic performance of an advanced polymer (LaRC-SI) was investigated through the use of creep compliance tests. Testing consisted of short-term isothermal creep and recovery with the creep segments performed under constant load. The tests were conducted at three temperatures below the glass transition temperature of five materials of different molecular weight. Through the use of time-aging-time superposition procedures, the material constants, material master curves and aging-related parameters were evaluated at each temperature for a given molecular weight. The time-temperature superposition technique helped to describe the effect of temperature on the timescale of the viscoelastic response of each molecular weight. It was shown that the low molecular weight materials have higher creep compliance and creep rate, and are more sensitive to temperature than the high molecular weight materials. Furthermore, a critical molecular weight transition was observed to occur at a weight-average molecular weight of M (bar) (sub w) 25000 g/mol below which, the temperature sensitivity of the time-temperature superposition shift factor increases rapidly. The short-term creep compliance data were used in association with Struik's effective time theory to predict the long-term creep compliance behavior for the different molecular weights. At long timescales, physical aging serves to significantly decrease the creep compliance and creep rate of all the materials tested.

Nicholson, Lee M.↗

Building Stock Segmentation Cluster Development: Technical Reference Document

The building stock in the United States (U.S.) varies significantly as a function of several macro variables such as: climate, building type, vintage, and density. These variables change across the U.S. and can also significantly impact energy usage of the individual buildings and overall stock. For example, the square foot density and building type varies by several orders of magnitude from Manhattan to the eastern plains of Colorado. The diversity in energy use of the building stock of different areas of the U.S. is significant, and as a result, analyses that require localized results need to consider the relevant geography and the current makeup of the building stock. This document discusses the development and implementation of a stock clustering algorithm that produces a technically rigorous, consistent, and repeatable collection of geographies which are used as the basis for localized analysis. This framework considers the impact of built environment density, diversity, and climate in creating groupings of counties that create a far more nuanced analysis framework than national averages. Clustering of counties together represents a similarity of building characteristics and climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗