Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Complex Sources and Impacts on Remediation and Monitoring Approaches - 19058

Remedy selection, implementation, and coordination with tank farm activities for adjacent waste sites need to be facilitated by a technically defensible description of sources and their relative strength and temporal contributions to groundwater contamination. Detailed data describing contaminant source releases are typically not available, so source locations are highly uncertain. Furthermore, data on sources and model parameters are not readily available through direct measurements. Instead, source data are often derived by extrapolation from a few direct and/or indirect measurements, while model parameters are commonly estimated using inverse modeling or calibration methods. Because the conceptual model of sources will influence the mass and timing of the flux of contaminants to groundwater, uncertainty in the source terms should be considered. Even though a best-fit model can often be identified, it may not be the best representation of the sources given the sparse, uncertain nature of the data used for estimating source terms. To support future feasibility studies, a systematic approach is needed for identifying remediation and monitoring activities appropriate under conditions of uncertainty. In this study, an integrated assessment of alternative conceptual model elements has been examined using the B-Complex site in the Hanford Central Plateau to demonstrate how multiple sources in a waste management complex can be described to identify their relative contributions to groundwater. The heterogeneous structure of the system is modeled based on available field information on the lithological data for both the vadose zone and aquifer. The approach includes a simulation assessment and linkages to site data, with an uncertainty analysis applied to evaluate the effects of source term uncertainty on contaminant mass flux to groundwater. An integrated assessment of alternative conceptual model elements was evaluated to identify how parameter uncertainty impacts both temporal and spatial uncertainties associated with vadose zone source terms. Modeling scenarios identify important characteristics of remediation target zones to provide context for how surface barriers, in situ remedies, and water-table treatment zones can be designed to account for source dynamics. Ramifications for remediation and monitoring are discussed within the context of the source term uncertainty. The described approach facilitates systematically addressing alternative conceptual model questions in relation to remediation and monitoring and supports the remedial investigation/ feasibility study process and the remediation strategy development for the Hanford Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of mass reduction, flow reduction and enhanced biodecay of DNAPL source zones

A mathematical model and an analytical solution are presented to describe field-scale dense non-aqueous phase liquid (DNAPL) source dissolution and source zone biodecay rates coupled with advective-dispersive dissolved plume transport. The model is employed to investigate various source remediation options on source zone mass depletion, net source mass flux, and dissolved plume attenuation for different source zone 'architectures' (i.e., pools versus residual DNAPL) and compliance criteria. Remediation options considered include partial source mass removal, source flow reduction, and source zone enhanced biodecay. Partial mass reduction reduces the source zone mass flux and downgradient concentrations for residual DNAPL sources and pools, which can significantly reduce dissolved plume size and time to reach compliance criteria. Source zone flow reduction decreases the rate of source mass depletion, but can facilitate compliance, if concentrations at compliance locations are not too high initially. Increase in source biodecay rate, especially with concomitant increases in dissolution kinetics, can decrease the time to achieve compliance criteria over biodecay alone.

54 ENVIRONMENTAL SCIENCES↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗

Infrasonic directivity of monopole, dipole and bipole ground-surface reflected sources

Infrasound (acoustic waves below 20 Hz) can be used to detect, locate and quantify activity in the atmosphere such as volcanic eruptions and anthropogenic explosions. Attempts to quantify volcanic eruption parameters such as exit velocity, plume height and mass flow rate using infrasound data depend strongly on assumptions of the acoustic source type. Infrasonic sources may produce omnidirectional or directional wavefields, while propagation effects, such as interaction with topography, can induce further wavefield directivity that is measured by field instrumentation. Limited sampling of these wavefields can hinder our ability to infer the underlying source, and thus our understanding of the eruption characteristics. Equivalent sources are often used to represent acoustic source mechanisms and resultant wavefields. In this study, we review equivalent acoustic sources as they pertain to infrasonic scale and wavelengths commonly encountered in very local (⁠<5 km range) geophysical field deployments. We highlight the equivalent infrasonic bipole source that can be induced by ground-reflection of an elevated monopole; we are not aware of any prior infrasound studies that use the bipole source concept. We use analytical and numerical methods to explore source directivity of monopole, dipole and bipole ground-reflected sources at infrasonic frequencies as well as the additional directivity complications introduced by interactions with topography. We illustrate that for typical volcano-infrasound wavelengths, increasing height above the ground as well as increasing source frequency leads to increased wavefield directivity. Numerical modelling using a simple omnidirectional monopole source embedded in topography further illustrates that both horizontal and vertical infrasound directionality can be induced by topography at the distance scales appropriate for local volcano infrasound monitoring. Information summarized in this analytical and numerical exploration of infrasound directivity may be used to help guide future volcano-infrasound field deployments intended to estimate source parameters or quantify wavefield directivity. Analytic solutions for simple whole-space or half-space atmospheres provide useful formulations for planning or initially analysing geophysical field-scale experimental data; however, especially at very local distances from the source (⁠<5 km), 3-D simulations are necessary to account for complex topography commonly encountered in volcano-infrasound applications.

Infrasound↗

Surrogate Distributed Radiological Sources—Part II: Aerial Measurement Campaign

In this second part of a multipaper series, we present results from outdoor aerial measurements of surrogate distributed gamma-ray sources. Here we detail the design, manufacture, and testing of 300 individual ~7 mCi Cu-64 sealed sources at the Washington State University (WSU) research reactor and their deployment in various source patterns (each comprising up to 100 point sources) during the aerial measurement campaign. We show the results of two such measurements, in which approximate source shapes and qualitative source intensities can be seen from the count rate versus position plots, even without performing reconstructions. We also detail our efforts in ground-truthing the deployed sources and comparing measured gamma-ray data to model predictions. In particular, we compare measured versus expected count data using the Poisson deviance formalism of Part I to evaluate whether the fielded surrogate point-source arrays “look like” their truly continuous distributed source analogs. More generally, we find that the point-source array technique provides high source placement accuracy, relative ease of quantifying the true source configuration, scalability to source dimensions of ≲100 m, ease of reconfiguration and removal, and relatively low dose to personnel. Finally, we consider potential improvements and generalizations of the point-source array technique for future measurement campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-54: Determination of the AAPM TG-43 Brachytherapy Dosimetry Parameters for A New Titanium-Encapsulated Yb-169 Source by Monte Carlo Calculations

Purpose: To determine the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source designed to maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT). Methods: An existing Monte Carlo (MC) model of the titanium-encapsulated Yb-169 source, which was described in the current investigators’ published MC optimization study, was modified based on the source manufacturer’s detailed specifications, resulting in an accurate model of the titanium-encapsulated Yb-169 source that was actually manufactured. MC calculations were then performed using the MCNP5 code system and the modified source model, in order to obtain a complete set of the AAPM TG-43 parameters for the new Yb-169 source. Results: The MC-calculated dose rate constant for the new titanium-encapsulated Yb-169 source was 1.05 ± 0.03 cGy per hr U, indicating about 10% decrease from the values reported for the conventional stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were found similar to those reported for the conventional Yb-169 sources. Conclusion: In this study, the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source were determined by MC calculations. The current results suggested that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source, while it would allow more low energy photons being transmitted through the source filter thereby leading to an increased dose enhancement during GNRT. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1- 0198.

60 APPLIED LIFE SCIENCES↗

California GAMA Special Study: An isotopic and dissolved gas investigation of nitrate source and transport to a public supply well in California's Central Valley

This study investigates nitrate contamination of a deep municipal drinking water production well in Ripon, CA to demonstrate the utility of natural groundwater tracers in constraining the sources and transport of nitrate to deep aquifers in the Central Valley. The goal of the study was to investigate the origin (source) of elevated nitrate and the potential for the deep aquifer to attenuate anthropogenic nitrate. The site is ideal for such an investigation. The production well is screened from 165-325 feet below ground surface and a number of nearby shallow and deep monitoring wells were available for sampling. Furthermore, potential sources of nitrate contamination to the well had been identified, including a fertilizer supply plant located approximately 1000 feet to the east and local almond groves. A variety of natural isotopic and dissolved gas tracers including {sup 3}H-{sup 3}He groundwater age and the isotopic composition of nitrate are applied to identify nitrate sources and to characterize nitrate transport. An advanced method for sampling production wells is employed to help identify contaminant contributions from specific screen intervals. Nitrate transport: Groundwater nitrate at this field site is not being actively denitrified. Groundwater parameters indicate oxic conditions, the dissolved gas data shows no evidence for excess nitrogen as the result of denitrification, and nitrate-N and -O isotope compositions do not display patterns typical of denitrification. Contaminant nitrate source: The ambient nitrate concentration in shallow groundwater at the Ripon site ({approx}12 mg/L as nitrate) is typical of shallow groundwaters affected by recharge from agricultural and urban areas. Nitrate concentrations in Ripon City Well 12 (50-58 mg/L as nitrate) are significantly higher than these ambient concentrations, indicating an additional source of anthropogenic nitrate is affecting groundwater in the capture zone of this municipal drinking water well. This study provides two new pieces of evidence that the Ripon Farm Services Plant is the source of elevated nitrate in Ripon City Well 12. (1) Chemical mass balance calculations using nitrate concentration, nitrate isotopic composition, and initial tritium activity all indicate that that the source water for elevated nitrate to Ripon City Well 12 is a very small component of the water produced by City Well 12 and thus must have extremely high nitrate concentration. The high source water nitrate concentration ({approx}1500 mg/L as nitrate) required by these mass balance calculations precludes common sources of nitrate such as irrigated agriculture, dairy wastewater, and septic discharge. Shallow groundwater under the Ripon Farm Services RFS plant does contain extremely high concentrations of nitrate (>1700 mg/L as nitrate). (2) Nitrogen and oxygen isotope compositions of nitrate indicate that the additional anthropogenic nitrate source to Ripon City Well 12 is significantly enriched in {delta}{sup 18}O-NO{sub 3}, an isotopic signature consistent with synthetic nitrate fertilizer, and not with human or animal wastewater discharge (i.e. dairy operations, septic system discharge, or municipal wastewater discharge), or with organic fertilizer. Monitoring wells on and near the RFS plant also have high {delta}{sup 18}O-NO{sub 3}, and the plant has handled and stored synthetic nitrate fertilizer that will have this isotopic signature. The results described here highlight the complexity of attributing nitrate found in long screened, high capacity wells to specific sources. In this case, the presence of a very high concentration source near the well site combined with sampling using multiple isotopic tracer techniques and specialized depth-specific techniques allowed fingerprinting of the source in the mixed-age samples drawn from the production well.

54 ENVIRONMENTAL SCIENCES↗

Sources of Propane Consumed in California

Project Scope: The objective of this study is to specify the sources of propane consumed in California. It answers the questions, where does the propane used in California come from and how was it produced? The results of this study provide comprehensive, transparent, and verifiable estimates, based on the 2018 market. The information provided in this report is suitable for use to assess the life cycle carbon intensity of propane used as a transportation fuel in California. As the 2009 Low Carbon Fuel Standard (LCFS) aims to reduce California’s greenhouse gas (GHG) emissions and other smog-forming and toxic air pollutants, the appropriate designation of carbon intensity for propane as a transportation fuel is important for evaluating propane’s potential to contribute to GHG goals and understandings in the context of various actions. This study focuses on estimating the shares of total propane consumed in the state of California produced from petroleum refineries, natural gas plants, and bituminous sands sources inside California and elsewhere. Results: An estimated 590 million gallons of propane were consumed in California in 2018, of which, 59.5% originated from refinery production and 40.5% originated from natural gas plants. The majority of this was sourced from refinery production in California, 334 million gallons. Most of the propane imported to California for consumption was sourced from natural gas plants, 113 million gallons, with over half of the imported volume sourced from Canada. The volume sourced from bituminous sand upgrader and fractionator operations was negligible. Details from this analysis are presented in the table below which provides an overview of the propane flows estimated in this study by region and production method. The shares and volumes presented here represent a snapshot for 2018. A significant increase in propane demand, such as could be caused by increased use of propane as a transportation fuel in the state, would affect California’s propane production, imports, and exports. The method and data sources used for the estimates provided in this report also provide the framework which could be used for future updates. Key Method Considerations: The values presented here are based on a two-step approach where the first step was to determine the flows of propane into and out of California from different regions and the second step was to estimate the propane production methods in each region. A volume balance approach is used as the primary method for tracking the volume of propane in and out of California as propane production and import volumes are available by Petroleum Administration of Defense District (PADD) from EIA and neither inter-PADD propane transfers nor state-specific non-prime supplier consumption are available from a public data source. The volume balance performed for this study covered PADD 5 (the West Coast), which includes Arizona, California, Nevada, Oregon, and Washington. The volume balance used all available public datasets to determine propane production, imports, exports, and consumption. Volumes unaccounted for by these datasets were estimated using the resulting volume balance by assuming market equilibrium. Consumption within each state in PADD 5 was estimated based on known import, export, and production volumes and this amount was used to develop the volume balance. EIA only tracks consumption at the state level by prime supplier sales. The volume balance approach provides the basis to correct for additional propane consumed in-states where propane is transferred to California. To determine the California propane sources and trade in 2018. volume of propane consumed in California, the volume balance approach is again used where it was estimated all imported volumes not specifically flagged for re-export were consumed, and the remaining consumption was produced in-state. The California Energy Commission (CEC) provided the total volume of propane imported and exported from California in 2018; this volume data set along with commodity tracking from the Canada Energy Regulator (CER) and the International Trade Commission (ITC) which tracks port of entry and final destination was used to determine where propane originated from and where it was ultimately consumed. For example, the CER tracks propane leaving Canada and entering each state within the U.S. Imported propane from Canada to California – marked for California – is assumed to be consumed in California. When no further data were available, import volumes were assumed to be consumed in California without pass-through (i.e., no propane imported to California was directly sold and exported). In most cases, the production method for each propane source region was applied to the volume of propane transferred to California. In other words, the shares of propane sourced from natural gas and refineries for each production region was assigned to California imports based on their contribution to the total volume flows into California to determine the production method for propane consumed in-state. For volumes imported into California from PADD 4, Washington State, Canada, and the rest of the world (Argentina, Chile, Norway, Peru, South Korea, and Trinidad and Tobago), the volumes sourced from petroleum refineries and natural gas plants reflect the either production ratio for the region or, in cases where the sources specific to the amounts exported to California could be determined, the sources specific to the volumes transferred to California.

03 NATURAL GAS↗

Complex Sources and Impacts on Remediation and Monitoring Approaches

Remedy selection, implementation, and coordination with tank farm activities for adjacent waste sites need to be facilitated by a technically defensible description of sources and their relative strength and temporal contributions to groundwater contamination. Detailed data describing contaminant source releases are typically not available, so source locations are highly uncertain. Furthermore, data on sources and model parameters are not readily available through direct measurements. Instead, source data are often derived by extrapolation from a few direct and/or indirect measurements, while model parameters are commonly estimated using inverse modeling or calibration methods. Because the conceptual model of sources will influence the mass and timing of the flux of contaminants to groundwater, uncertainty in the source terms should be considered. Even though a best-fit model can often be identified, it may not be the best representation of the sources given the sparse, uncertain nature of the data used for estimating source terms. To support future feasibility studies, a systematic approach is needed for identifying remediation and monitoring activities appropriate under conditions of uncertainty. In this study, an integrated assessment of alternative conceptual model elements has been examined using the B-Complex site in the Hanford Central Plateau to demonstrate how multiple sources in a waste management complex can be described to identify their relative contributions to groundwater. The heterogeneous structure of the system is modeled based on available field information on the lithological data for both the vadose zone and aquifer. The approach includes a simulation assessment and linkages to site data, with an uncertainty analysis applied to evaluate the effects of source term uncertainty on contaminant mass flux to groundwater. An integrated assessment of alternative conceptual model elements was evaluated to identify how parameter uncertainty impacts both temporal and spatial uncertainties associated with vadose zone source terms. Modeling scenarios identify important characteristics of remediation target zones to provide context for how surface barriers, in situ remedies, and water-table treatment zones can be designed to account for source dynamics. Ramifications for remediation and monitoring are discussed within the context of the source term uncertainty. The described approach facilitates systematically addressing alternative conceptual model questions in relation to remediation and monitoring and supports the remedial investigation/ feasibility study process and the remediation strategy development for the Hanford Central Plateau.

Rockhold, Mark L.↗

Ionic debris measurement of three extreme ultraviolet sources

Generation of debris in extreme ultraviolet (EUV) light sources is an inherent and real threat to the lifetime of collection optics. Debris measurement of these sources is useful to enable source suppliers to estimate collector lifetime. At the Center for Plasma Material Interactions (CPMI) at the University of Illinois, an Illinois calibrated spherical sector electrostatic energy analyzer (ICE) was built to measure the ion debris flux in absolute units. In addition to ion flux, the detector is also capable of identifying different ion species present in the plasma utilizing energy-to-charge ratio discrimination. The lifetime of the collector optics is calculated using the measured ion flux. In the current investigation we compare the measurement of ion debris production in three different EUV sources: the Energetiq EQ-10M, the AIXUV-100, and the XTREME XTS 13-35. In the EQ-10M source, three angular measurements are coupled with three variations in operating pressure to measure consequent effects on debris production. These measurements reveal four predominant ion species in the energetic debris analysis: C{sup +}, Si{sup +}, Xe{sup +}, and Xe{sup 2+}. The amount of debris is reduced as pressure is increased. Various debris mitigation methods are implemented in the AIXUV-100 source and results reveal that four ion species are observed (Ar{sup +}, Xe{sup +}, Xe{sup 2+}, and W{sup +}), though there does not seem to be a dominant species. The first mitigation technique, backstreaming argon toward the source, reduces the amount of Ar{sup +}, Xe{sup 2+}, and W{sup +}, yet increases the amount of Xe{sup +} The increase in Xe{sup +} flux is explained based on charge exchange phenomena. The ICE machine was then attached 1.92 m away from the pinch of XTS 13-35 source, and placed at 25 deg. away from the normal line. The comparison of results reveals that the XTS 13-35 and the EQ-10M sources produced comparable amounts of energetic ion flux per watt of EUV light produced. The AIXUV-100 source generated more ion debris flux per watt of EUV light than the other two sources, though it should be noted that the AIXUV-100 source was capable of producing more than ten times the amount of EUV light power compared to any of the other sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Primary calibration of coiled {sup 103}Pd brachytherapy sources

Coiled {sup 103}Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S{sub K}) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S{sub K} of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S{sub K} of the longer coiled sources. The UW VAFAC has shown agreement in S{sub K} values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S{sub K} of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Approach for Long-Term Management of Disused Sealed Radioactive Sources - 13630

Radioactive sources are used widely throughout the world in a variety of medical, industrial, research and military applications. When such radioactive sources are no longer used and are not intended to be used for the practice for which an authorization was granted, they are designated as 'disused sources'. Whether appropriate controls are in place during the useful life of a source or not, the end of this useful life is often a turning point after which it is more difficult to ensure the safety and security of the source over time. For various reasons, many disused sources cannot be returned to the manufacturer or the supplier for reuse or recycling. When these attempts fail, disused sources should be declared as radioactive waste and should be managed as such, in compliance with relevant international legal instruments and safety standards. However, disposal remains an unresolved issue in many counties, due to in part to limited public acceptance, insufficient funding, and a lack of practical examples of strategies for determining suitable disposal options. As a result, disused sources are often stored indefinitely at the facilities where they were once used. In order to prevent disused sources from becoming orphan sources, each country must develop and implement a comprehensive waste management strategy that includes disposal of disused sources. The International Atomic Energy Agency (IAEA) fosters international cooperation between countries and encourages the development of a harmonized 'cradle to grave' approach to managing sources consistent with international legal instruments, IAEA safety standards, and international good practices. This 'cradle to grave' approach requires the development of a national policy and implementing strategy, an adequate legal and regulatory framework, and adequate resources and infrastructure that cover the entire life cycle, from production and use of radioactive sources to disposal. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Ion source development for various applications in Korea (invited) (abstract)

Ion source development in Korea has been related with various applications from accelerator to nanotechnology. Conventional ion sources such as Duoplasmatron and PIG ion sources were developed for high power proton accelerator and small cyclotron accelerators. To improve lifetime of the high current proton ion source, helicon plasma ion sources were developed with external rf antenna and applied for neutron generation in drive-in-target configuration. Negative hydrogen ion sources were also developed for tandem and cyclotron accelerators by using both rf and filament discharges. Large-area high-current ion sources for the KSTAR NBI system were developed and successfully tested for long-pulse operation of up to 300 s. Several broad beam ion sources for industrial applications such as ion implantation and surface treatment were also developed by using arc, rf, and microwave discharges. Recently, ion source applications become diversified to the area of nano- and biotechnologies. For example, C60 ion source was developed for the use of bioapplications in nanometer scale. For focused ion beam as a nanofabrication tool, liquid metal ion sources were improved and a novel plasma ion source was developed by utilizing localized sheath discharges. Research and development activities of these ion sources will be discussed with short description of appropriate applications.

43 PARTICLE ACCELERATORS↗

HIGH-FREQUENCY RADIO SPECTRAL ENERGY DISTRIBUTIONS AND POLARIZATION FRACTIONS OF SOURCES IN AN ATACAMA COSMOLOGY TELESCOPE SURVEY FIELD

We present flux densities and polarization percentages of 159 radio galaxies based on nearly simultaneous Very Large Array observations at four frequencies, 4.86, 8.46, 22.46, and 43.34 GHz. This sample is selected from the high-frequency Australia Telescope 20 GHz (AT20G) survey and consists of all sources with flux density S{sub 20GHz} > 40 mJy in an equatorial field of the Atacama Cosmology Telescope (ACT) survey. For a subset of 25 of these sources, we used the Green Bank Telescope (GBT) to obtain 90 GHz data. The goals of this program are: (1) a characterization of the spectra, polarization, and variability of high-frequency-selected radio sources, (2) extrapolating from the few GHz regime to the {approx}150 GHz regime of the ACT survey, allowing for more accurate removal of the radio source signal in our particular field, and (3) providing a data set that will allow more accurate modeling of the high-frequency radio source contamination in current and future Sunyaev-Zeldovich and cosmic microwave background experiments. We find that, as expected, this sample consists of flatter spectrum and more compact or point-like sources than low-frequency-selected samples. In the K band, variability is typically {approx}<20%, although there are exceptions. The higher frequency data are well suited to the detection of extreme gigahertz peak spectrum sources. The inclusion of the 43 GHz data causes the relative fraction of inverted spectrum sources to go down and of peaked spectrum sources to go up when compared with the AT20G survey results. The trend largely continues with the inclusion of the 90 GHz data, although {approx}10% of the sources with GBT data show a spectral upturn from 43 GHz to 90 GHz. The measured polarization fractions are typically <5%, although in some cases they are measured to be up to {approx}20%. For sources with detected polarized flux in all four bands, about 40% of the sample, the polarization fractions typically increase with frequency. This trend is stronger for steeper spectrum sources as well as for the lower flux density sources.

79 ASTRONOMY AND ASTROPHYSICS↗

DEEP CHANDRA MONITORING OBSERVATIONS OF NGC 4649. I. CATALOG OF SOURCE PROPERTIES

We present the X-ray source catalog for the Chandra monitoring observations of the elliptical galaxy, NGC 4649. The galaxy has been observed with Chandra ACIS-S3 in six separate pointings, reaching a total exposure of 299 ks. There are 501 X-ray sources detected in the 0.3-8.0 keV band in the merged observation or in one of the six individual observations; 399 sources are located within the D{sub 25} ellipse. The observed 0.3-8.0 keV luminosities of these 501 sources range from 9.3 Multiplication-Sign 10{sup 36} erg s{sup -1} to 5.4 Multiplication-Sign 10{sup 39} erg s{sup -1}. The 90% detection completeness limit within the D{sub 25} ellipse is 5.5 Multiplication-Sign 10{sup 37} erg s{sup -1}. Based on the surface density of background active galactic nuclei (AGNs) and detection completeness, we expect Almost-Equal-To 45 background AGNs among the catalog sources ( Almost-Equal-To 15 within the D{sub 25} ellipse). There are nine sources with luminosities greater than 10{sup 39} erg s{sup -1}, which are candidates for ultraluminous X-ray sources. The nuclear source of NGC 4649 is a low-luminosity AGN, with an intrinsic 2.0-8.0 keV X-ray luminosity of 1.5 Multiplication-Sign 10{sup 38} erg s{sup -1}. The X-ray colors suggest that the majority of the catalog sources are low-mass X-ray binaries (LMXBs). We find that 164 of the 501 X-ray sources show long-term variability, indicating that they are accreting compact objects. We discover four transient candidates and another four potential transients. We also identify 173 X-ray sources (141 within the D{sub 25} ellipse) that are associated with globular clusters (GCs) based on Hubble Space Telescope and ground-based data; these LMXBs tend to be hosted by red GCs. Although NGC 4649 has a much larger population of X-ray sources than the structurally similar early-type galaxies, NGC 3379 and NGC 4278, the X-ray source properties are comparable in all three systems.

79 ASTRONOMY AND ASTROPHYSICS↗

UNVEILING THE NATURE OF THE UNIDENTIFIED GAMMA-RAY SOURCES. IV. THE SWIFT CATALOG OF POTENTIAL X-RAY COUNTERPARTS

A significant fraction (∼30%) of the high-energy γ-ray sources listed in the second Fermi Large Area Telescope (LAT) catalog are still of unknown origin, having not yet been associated with counterparts at lower energies. To investigate the nature of these enigmatic sources, we present an extensive search of X-ray sources lying in the positional uncertainty region of a selected sample of these unidentified gamma-ray sources (UGSs) that makes use of all available observations performed by the Swift X-ray Telescope before 2013 March 31, available for 205 UGSs. To detect the fainter sources, we merged all the observations covering the Fermi LAT positional uncertainty region at a 95% level of confidence of each UGS. This yields a catalog of 357 X-ray sources, finding candidate X-ray counterparts for ∼70% of the selected sample. In particular, 25% of the UGSs feature a single X-ray source within their positional uncertainty region, while 45% have multiple X-ray sources. For each X-ray source, we also looked in the corresponding Swift UVOT merged images for optical and ultraviolet counterparts, also performing source photometry. We found ultraviolet-optical correspondences for ∼70% of the X-ray sources. We searched several major radio, infrared, optical, and ultraviolet surveys for possible counterparts within the positional error of the sources in the X-ray catalog to obtain additional information on their nature. Applying the kernel density estimation technique to infrared colors of Wide-Field Infrared Survey Explorer counterparts of our X-ray sources we select six γ-ray blazar candidates. In addition, comparing our results with previous analyses, we select 11 additional γ-ray blazar candidates.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon energy spectrum emitted by a novel polymer-encapsulated {sup 103}Pd source and its effect on the dose rate constant

Two independent groups have published intrinsic dosimetry parameters for the recently introduced OptiSeed{sup 103} interstitial brachytherapy source which contains {sup 103}Pd encapsulated by a novel polymer shell. The dose rate constant ({lambda}) reported by the two groups, however, differed by more than 6% and there is currently no AAPM recommended consensus value for this source in clinical dosimetry. The aim of this work was to perform an independent determination of {lambda} for the OptiSeed{sup 103} source using a recently developed photon spectrometry technique. Three OptiSeed{sup 103} sources (model 1032P) with known air-kerma strength were used in this study. The photon energy spectrum emitted along the radial direction on the source's bisector was measured in air using a high-resolution intrinsic germanium spectrometer designed and established for low-energy brachytherapy source spectrometry. The dose rate constant of each source was determined from its emitted energy spectrum and the spatial distribution of radioactivity in the source. Unlike other sources made with traditional titanium encapsulation, the photons emitted by the OptiSeed{sup 103} sources exhibited only slight spectral hardening, yielding a relative energy spectrum closer to that emitted by bare {sup 103}Pd. The dose rate constant determined by the photon spectrometry technique for water was 0.664{+-}0.025 cGy h{sup -1} U{sup -1}. This value agreed, within experimental uncertainties, with the Monte Carlo-calculated value ({sub MC}{lambda}) of 0.665{+-}0.014 cGy h{sup -1} U{sup -1} and the TLD-measured value (with a Monte Carlo-calculated solid-phantom-to-water conversion factor) of 0.675{+-}0.051 cGy h{sup -1} U{sup -1} reported by Wang and Hertel [Appl. Radiat. Isot. 63, 311-321 (2005)]. However, it differed by -6.7% from the {sub MC}{lambda} of 0.712{+-}0.043 cGy h{sup -1} U{sup -1} reported by Bernard and Vynckier [Phys. Med. Biol. 50, 1493-1504 (2005)]. The results obtained in this work provide additional information needed for establishing a consensus value for the dose rate constant for the OptiSeed{sup 103} source. It suggests that an eventual consensus value of {lambda} for the OptiSeed{sup 103} source is likely to be closer to a value of 0.668 cGy h{sup -1} U{sup -1} rather than 0.693 cGy h{sup -1}U{sup -1} as initially recommended by the source manufacturer based on the two previously published results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗