Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A Survey of Techniques for Approximate Computing

Approximate computing trades off computation quality with the effort expended and as rising performance demands confront with plateauing resource budgets, approximate computing has become, not merely attractive, but even imperative. Here, we present a survey of techniques for approximate computing (AC). We discuss strategies for finding approximable program portions and monitoring output quality, techniques for using AC in different processing units (e.g., CPU, GPU and FPGA), processor components, memory technologies etc., and programming frameworks for AC. Moreover, we classify these techniques based on several key characteristics to emphasize their similarities and differences. Finally, the aim of this paper is to provide insights to researchers into working of AC techniques and inspire more efforts in this area to make AC the mainstream computing approach in future systems.

97 MATHEMATICS AND COMPUTING↗

Practical application of cross correlation technique to measure jitter of master-oscillator-power-amplifier laser system

The Linac coherent light source (LCLS) at the SLAC National Accelerator Laboratory (SLAC) is the world’s first hard X-ray free electron laser (XFEL) and is capable of producing high-energy, femtosecond duration X-ray pulses. A common technique to study fast timescale physical phenomena, various “pump/probe” techniques are used. In these techniques there are two lasers, one optical and one X-ray, that work as a pump and as a probe to study dynamic processes in atoms and molecules. In order to resolve phenomena that occur on femtosecond timescales, it is imperative to have very precise timing between the optical lasers and X-rays (on the order of ~ 20 fs or better). The lasers are synchronized to the same RF source that drives the accelerator and produces the X-ray laser. However, elements in the lasers cause some drift and time jitter, thereby de-synchronizing the system. This paper considers cross-correlation technique as a way to quantify the drift and jitter caused by the regenerative amplifier of the ultrafast optical laser.

cross-correlation↗

Detection of illicit HEU production in gaseous centrifuge enrichment plants using neutron counting techniques on product cylinders

Innovative and novel safeguards approaches are needed for nuclear energy to meet global energy needs without the threat of nuclear weapons proliferation. Part of these efforts will include creating verification techniques that can monitor uranium enrichment facilities for illicit production of highly-enriched uranium (HEU). Passive nondestructive assay (NDA) techniques will be critical in preventing illicit HEU production because NDA offers the possibility of continuous and unattended monitoring capabilities with limited impact on facility operations. Gaseous centrifuge enrichment plants (GCEP) are commonly used to produce low-enriched uranium (LEU) for reactor fuel. In a GCEP, gaseous UF{sub 6} spins at high velocities in centrifuges to separate the molecules containing {sup 238}U from those containing the lighter {sup 235}U. Unfortunately, the process for creating LEU is inherently the same as HEU, creating a proliferation concern. Insuring that GCEPs are producing declared enrichments poses many difficult challenges. In a GCEP, large cascade halls operating thousands of centrifuges work together to enrich the uranium which makes effective monitoring of the cascade hall economically prohibitive and invasive to plant operations. However, the enriched uranium exiting the cascade hall fills product cylinders where the UF{sub 6} gas sublimes and condenses for easier storage and transportation. These product cylinders hold large quantities of enriched uranium, offering a strong signal for NDA measurement. Neutrons have a large penetrability through materials making their use advantageous compared to gamma techniques where the signal is easily attenuated. One proposed technique for detecting HEU production in a GCEP is using neutron coincidence counting at the product cylinder take off stations. This paper discusses findings from Monte Carlo N-Particle eXtended (MCNPX) code simulations that examine the feasibility of such a detector.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty Analysis on the Design of Thermal Conductivity Measurement by a Guarded Cut-Bar Technique

A technique adapted from the guarded-comparative-longitudinal heat flow method was selected for the measurement of the thermal conductivity of a nuclear fuel compact over a temperature range characteristic of its usage. This technique fulfills the requirement for non-destructive measurement of the composite compact. Although numerous measurement systems have been created based on the guarded comparative method, comprehensive systematic (bias) and measurement (precision) uncertainty associated with this technique have not been fully analyzed. In addition to the geometric effect in the bias error, which has been analyzed previously, this paper studies the working condition which is another potential error source. Using finite element analysis, this study showed the effect of these two types of error sources in the thermal conductivity measurement process and the limitations in the design selection of various parameters by considering their effect on the precision error. The results and conclusions provide valuable reference for designing and operating an experimental measurement system using this technique.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Devices Materials and Processes for Nanoelectronics: Characterization with Advanced X-Ray Techniques Using Lab-Based and Synchrotron Radiation Sources

Future nanoelectronics manufacturing at extraordinary length scales, new device structures, and advanced materials will provide challenges to process development and engineering but also to process control and physical failure analysis. Advanced X-ray techniques, using lab systems and synchrotron radiation sources, will play a key role for the characterization of thin films, nanostructures, surfaces, and interfaces. The development of advanced X-ray techniques and tools will reduce risk and time for the introduction of new technologies. Eventually, time-to-market for new products will be reduced by the timely implementation of the best techniques for process development and process control. The development and use of advanced methods at synchrotron radiation sources will be increasingly important, particularly for research and development in the field of advanced processes and new materials but also for the development of new X-ray components and procedures. The application of advanced X-ray techniques, in-line, in out-of-fab analytical labs and at synchrotron radiation sources, for research, development, and manufacturing in the nanoelectronics industry is reviewed. The focus of this paper is on the study of nanoscale device and on-chip interconnect materials, and materials for 3D IC integration as well.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Absence and Importance of Operando Techniques for Metal-Free Catalysts

Operando characterization techniques have played an important role in modern technological developments. In contrast to the experimental uncertainties introduced by ex situ techniques, the simultaneous measurement of desired sample characteristics and near-realistic electrochemical testing provides a representative picture of the underlying physics. From Li-ion batteries to metal-based electrocatalysts, the insights offered by real-time characterization data have enabled more efficient research programs. As an emerging class of catalyst, much of the mechanistic understanding of metal-free electrocatalysts continues to be elusive in comparison to their metal-based counterparts. Yet, there is a clear absence of operando characterization performed on metal-free catalysts. Through the proper execution of operando techniques, it can be expected that metal-free catalysts can achieve exceptional technological progress. Here, the motivation of using operando characterization techniques for metal-free carbon-based catalyst system is considered, followed by a discussion of the possibilities, difficulties and benefits of their applications.

36 MATERIALS SCIENCE↗

Utilization of Data Augmentation Techniques in Automated Inspection Systems for Defect Detection in Metals With Limited Data

Accurate identification of defects on metal surfaces is of great interest to many industry sectors, such as the automotive and aerospace industries. In contrast to conventional manual inspection techniques, recent automated inspection systems employ deep learning models trained to detect defects rapidly and precisely. The development of these models often requires a substantial image dataset to acquire adequate knowledge of defect features and enhance their predictive accuracy. When data is limited, augmentation techniques are often used to improve the precision and accuracy of defect detection systems. This study examined the prediction performance of two object detection models, namely Faster Region‐based Convolutional Neural Network (Faster R‐CNN) and You Only Look Once version 8 (YOLOv8), to identify dent defects in limited images of cast iron cylinder head surfaces. The original image set contains 46 images with 563 dents. To overcome limited data availability, common image augmentation techniques along with a copy‐paste method were applied. Results show that standard augmentation improved YOLOv8 accuracy by 8.00% and average precision (AP) by 3.00%. On the other hand, the copy‐paste technique achieved a 20.00% increase in accuracy and a 1% increase in AP with just 200 synthetic dents. Furthermore, these results provide support for using the copy‐paste augmentation strategy to enhance defect detection performance, with a limited dataset, contributing to more accurate defect identification in remanufacturing processes.

36 MATERIALS SCIENCE↗

Emerging Electron Microscopy Techniques for Probing Functional Interfaces in Energy Materials

Abstract Interfaces play a fundamental role in many areas of chemistry. However, their localized nature requires characterization techniques with high spatial resolution in order to fully understand their structure and properties. State‐of‐the‐art atomic resolution or in situ scanning transmission electron microscopy and electron energy‐loss spectroscopy are indispensable tools for characterizing the local structure and chemistry of materials with single‐atom resolution, but they are not able to measure many properties that dictate function, such as vibrational modes or charge transfer, and are limited to room‐temperature samples containing no liquids. Here, we outline emerging electron microscopy techniques that are allowing these limitations to be overcome and highlight several recent studies that were enabled by these techniques. We then provide a vision for how these techniques can be paired with each other and with in situ methods to deliver new insights into the static and dynamic behavior of functional interfaces.

Zachman, Michael J.↗

Emerging Electron Microscopy Techniques for Probing Functional Interfaces in Energy Materials

Interfaces play a fundamental role in many areas of chemistry. However, their localized nature requires characterization techniques with high spatial resolution in order to fully understand their structure and properties. State-of-the-art atomic resolution or in situ scanning transmission electron microscopy and electron energy-loss spectroscopy are indispensable tools for characterizing the local structure and chemistry of materials with single-atom resolution, but they are not able to measure many properties that dictate function, such as vibrational modes or charge transfer, and are limited to room-temperature samples containing no liquids. Here, we outline emerging electron microscopy techniques that are allowing these limitations to be overcome and highlight several recent studies that were enabled by these techniques. We then provide a vision for how these techniques can be paired with each other and with in situ methods to deliver new insights into the static and dynamic behavior of functional interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crack detection in fuel cell electrodes using a spatial filtering technique for overcoming noisy backgrounds

Image processing is a powerful tool that allows for rapid and automated data parsing in settings that occupy large variable spaces and require large data sets. Feature detection on difficultly discerned backgrounds is a subset of image processing that facilitates the extraction of quantitative metrics from otherwise subjective data. Crack detection and quantification is an important capability in polymer electrolyte membrane fuel cell quality control, failure analysis, and optimization. This work presents a technique to perform crack detection and quantification which overcomes challenges faced by commonly used image segmentation techniques. We demonstrate the use of a geometrically filtered noise‐level detection technique to select a binary threshold value from which we then quantify how cracked a sample is. Furthermore, we demonstrate the accuracy of our technique using programmatically generated test images of known crack amounts and their performance on real‐world fuel cell catalyst layer samples.

30 DIRECT ENERGY CONVERSION↗

Application of side-hole catheter technique for transradial arterial chemoembolization in patients with hepatocellular carcinoma

Purpose: The purpose of this study was to retrospectively evaluate the efficacy and safety of side-hole catheter technique for transarterial chemoembolization (TACE) via transradial artery access (TRA) in patients with hepatocellular carcinoma. Materials and methods: From November 2015 to August 2017, a total of 1040 TACE procedures were performed via TRA for hepatocellular carcinoma. In 10 (1%) of these 1040 TACE procedures via TRA, conventional microcatheter technique (CMT) failed and side-hole catheter technique was attempted. Results: Ten procedures of selective catheterizations by CMT failed due to the poor stability of the angiographic catheters or the target artery arising from the very proximal portion of the parent artery. These arteries included the right inferior phrenic artery in eight patients, one left gastric artery, and one right renal capsular artery. Cobra or MPA catheter with the microcatheter through the side-hole yielded a technical success rate of 100%. No procedure-related complications were observed. The mean time required to catheterize the target artery with the side-hole catheter was 9.5 min (5–15 min). Conclusion: Side-hole catheter technique may enable the completion of chemoembolization in cases that a potential tumor-feeding vessel cannot be catheterized by means of CMT for TACE via TRA.

60 APPLIED LIFE SCIENCES↗

Radiofrequency Ablation of Colorectal Liver Metastases: Small Size Favorably Predicts Technique Effectiveness and Survival

The objective of this study was to analyze long-term results of radiofrequency thermal ablation (RFA) for colorectal metastases (MTS), in order to evaluate predictors for adverse events, technique effectiveness, and survival. One hundred ninety-nine nonresectable MTS (0.5-8 cm; mean, 2.9 cm) in 122 patients underwent a total of 166 RFA sessions, percutaneously or during surgery. The technique was 'simple' or 'combined' with vascular occlusion. The mean follow-up time was 24.2 months. Complications, technique effectiveness, and survival rates were statistically analyzed. Adverse events occurred in 8.1% of lesions (major complication rate: 1.1%), 7.1% with simple and 16.7% with combined technique (p = 0.15). Early complete response was obtained in 151 lesions (81.2%), but 49 lesions (26.3%) recurred locally after a mean of 10.4 months. Sustained complete ablation was achieved in 66.7% of lesions {<=}3 cm versus 33.3% of lesions >3 cm (p < 0.0001). Survival rates at 1, 3, and 5 years were 91%, 54%, and 33%, respectively, from the diagnosis of MTS and 79%, 38%, and 22%, respectively, from RFA. Mean survival time from RFA was 31.5 months, 36.2 in patients with main MTS {<=}3 cm and 23.2 in those with at least one lesion >3 cm (p = 0.006). We conclude that 'simple' RFA is safe and successful for MTS {<=}3 cm, contributing to prolong survival when patients can be completely treated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plug Anchoring Technique to Stabilize the Delivery System for Microcoil Embolization

PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to the first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Simple Hepatic Cysts: The Long-Term Results of PAIR and Catheterization Techniques as Single-Session Procedures

PurposeThe purpose of our study is to evaluate results of percutaneous aspiration with alcohol sclerotherapy in symptomatic patients with simple hepatic cysts by employing single-session techniques either by a needle or a catheter.Materials and MethodsWe retrospectively included 39 simple hepatic cysts in 35 patients treated via percutaneous aspiration and single-session alcohol sclerotherapy between years 1993 and 2012. Indications were pain (n = 28) or ruling out cystic echinococcus (CE) disease (n = 7). 29 cysts in 26 patients were treated by needle technique (Group A) and ten cysts in nine patients were treated by single-session catheter technique (Group B). Patients were followed for 4–173 months (median: 38 months).ResultsAll patients were successfully treated. Before procedure, cyst volumes were 21–676 cc (median: 94 cc). Post-procedure cyst volumes at last follow-up were 0-40 cc (median: 1 cc). The mean decrease in cyst volume was 95.92 ± 2.86 % in all patients (95.96 ± 3.26 % in Group A and 95.80 ± 6.20 % in Group B). There was no statistically significant difference between the volume reduction rates of Group A and Group B. Only one patient, in Group B, developed a major complication, an abscess. Hospitalization period was 1 day for all patients.ConclusionsFor patients with symptomatic simple hepatic cysts smaller than 500 cc in volume by using puncture, aspiration, injection, and reaspiration (PAIR) technique with only needle, single-session alcohol sclerotherapy of 10 min is a safe and effective procedure with high success rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A “Train-Track” Technique in Anatomic Reconstruction of SVC Bifurcation Complicated by Cardiac Tamponade: An Introspection

This report describes a stenting technique used to anatomically reconstruct superior vena cava (SVC) bifurcation in a patient with benign SVC syndrome. After recanalizing the SVC bifurcation, we exchanged two 0.035-in. wires for two 0.018-in. wires, deployed the SVC stent over these two wires (“train-track” technique), and stented each innominate vein over one wire. However, our decisions to recanalize both innominate veins, use the “buddy-wire” technique for SVC dilation, and dilate the SVC to 16 mm before stent deployment likely contributed to SVC tear, which was managed by resuscitation, SVC stent placement, and pericardial drainage. Here, we describe the steps of the train-track technique, which can be adopted to reconstruct other bifurcations; we also discuss the controversial aspects of this case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Barreled and Branched Endografting for Thoracoabdominal Aortic Aneurysm: The Hexapus Technique

Objective: To treat thoracoabdominal aortic aneurysm (TAAA), we introduced an alternative “Hexapus” technique by double-barreled and branched endografting. Technique and Result: We established 2 transfemoral and 2 transaxillary access routes first and then deployed two abdominal bifurcated stentgrafts landing at the descending thoracic aorta through transfemoral routes, respectively. Two pairs of parallel stentgrafts were deployed via bilateral transaxillary route from each of contralateral limbs of main body stentgrafts to visceral arteries. Finally, we extended the ipsilateral limbs of main body stentgrafts to bilateral common iliac arteries as distal landings. The creation of six branches (four viscerals and two iliacs) resembles a hexapus. We have executed this Hexapus technique in three patients, and the final angiography during operation and postoperative 12-month image follow-up showed patent visceral branches and no any endoleaks. Conclusion: Our Hexapus technique is feasible in treating TAAA if patient is inoperable or no commercial fenestrated or branched stentgraft is available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of thermal transport in micro/nanoscale wires by steady-state electro-Raman-thermal technique

In this work, a novel steady-state electro-Raman-thermal (SERT) technique is developed to characterize the thermal transport in one-dimensional micro/nanoscale materials. The SERT technique involves steady-state joule heating of a suspended sample and measuring its middle point temperature based on the temperature dependence of the Raman shift peak intensity. The thermal conductivity is determined from a linear fitting of the temperature against heating power. Multi-wall carbon nanotube bundles are characterized using the SERT technique to verify its measurement capacity. As it does not need to track the transient process of heat transfer, the SERT technique has the great potential for measuring short materials down to nm long.

77 NANOSCIENCE AND NANOTECHNOLOGY↗