At least 703 records · Page 39

Coolant and ambient temperature control for chillerless liquid cooled data centers

Cooling control methods and systems include measuring a temperature of air provided to one or more nodes by an air-to-liquid heat exchanger; measuring a temperature of at least one component of the one or more nodes and finding a maximum component temperature across all such nodes; comparing the maximum component temperature to a first and second component threshold and comparing the air temperature to a first and second air threshold; and controlling a proportion of coolant flow and a coolant flow rate to the air-to-liquid heat exchanger and the one or more nodes based on the comparisons.

42 ENGINEERING↗

Maintaining Trust in Reduction: Preserving the Accuracy of Quantities of Interest for Lossy Compression

As the growth of data sizes continues to outpace computational resources, there is a pressing need for data reduction techniques that can significantly reduce the amount of data and quantify the error incurred in compression. Compressing scientific data presents many challenges for reduction techniques since it is often on non-uniform or unstructured meshes, is from a high-dimensional space, and has many Quantities of Interests (QoIs) that need to be preserved. To illustrate these challenges, we focus on data from a large scale fusion code, XGC. XGC uses a Particle-In-Cell (PIC) technique which generates hundreds of PetaBytes (PBs) of data a day, from thousands of timesteps. XGC uses an unstructured mesh, and needs to compute many QoIs from the raw data, f.One critical aspect of the reduction is that we need to ensure that QoIs derived from the data (density, temperature, flux surface averaged momentums, etc.) maintain a relative high accuracy. We show that by compressing XGC data on the high-dimensional, nonuniform grid on which the data is defined, and adaptively quantizing the decomposed coefficients based on the characteristics of the QoIs, the compression ratios at various error tolerances obtained using a multilevel compressor (MGARD) increases more than ten times. We then present how to mathematically guarantee that the accuracy of the QoIs computed from the reduced f is preserved during the compression. We show that the error in the XGC density can be kept under a user-specified tolerance over 1000 timesteps of simulation using the mathematical QoI error control theory of MGARD, whereas traditional error control on the data to be reduced does not guarantee the accuracy of the QoIs.

Gong, Qian↗

Advanced data science toolkit for non-data scientists – A user guide

Emerging modern data analytics attracts much attention in materials research and shows great potential for enabling data-driven design. Data populated from the high-throughput CALPHAD approach enables researchers to better understand underlying mechanisms and to facilitate novel hypotheses generation, but the increasing volume of data makes the analysis extremely challenging. Here in this paper, we introduce an easy-to-use, versatile, and open-source data analytics frontend, ASCENDS (Advanced data SCiENce toolkit for Non-Data Scientists), designed with the intent of accelerating data-driven materials research and development. The toolkit is also of value beyond materials science as it can analyze the correlation between input features and target values, train machine learning models, and make predictions from the trained surrogate models of any scientific dataset. Various algorithms implemented in ASCENDS allow users performing quantified correlation analyses and supervised machine learning to explore any datasets of interest without extensive computing and data science background. The detailed usage of ASCENDS is introduced with an example of experimental high-temperature alloy data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Novel perovskite-related barium tungstate Ba{sub 11}W{sub 4}O{sub 23}

Ba{sub 11}W{sub 4}O{sub 23} was synthesized at 1300 deg. C, followed by quenching with liquid nitrogen. The crystal structure, which was known to be cryolite-related but has remained unclear, was initially determined by single-crystal X-ray diffraction for the isostructural Ru-substituted compound Ba{sub 11}(W{sub 3.1}Ru{sub 0.9})O{sub 22.5}, which was discovered during exploratory synthesis in the Ba-Ru-O system. The structure of Ba{sub 11}W{sub 4}O{sub 23} was refined by a combined powder X-ray and neutron Rietveld method (Fd-3m, a=17.1823(1) A, Z=8, R{sub p}=3.09%, R{sub wp}=4.25%, {chi}{sup 2}=2.8, 23 deg. C). The structure is an example of A-site vacancy-ordered 4x4x4 superstructure of a simple perovskite ABO{sub 3}, and it may be written as (Ba{sub 1.75}{open_square}{sub 0.25})BaWO{sub 5.75}{open_square}{sub 0.25}, emphasizing vacancies on both metal and anion sites. The local structure of one of two asymmetric tungsten ions is the WO{sub 6} octahedron, typical of perovskite. The other tungsten, however, is surrounded by oxygen and anionic vacancies statistically distributed over three divided sites to form 18 partially occupied oxygen atoms ({approx}30% on average), represented as WO{sub 18/3}. The A-site cation-vacancies are ordered at the 8a (1/8 , 1/8 , 1/8 ) site in between adjoining WO{sub 18/3} polyhedra which form 1-D arrangements along [110] and equivalent directions. In situ high-temperature XRD data have shown that the quenched Ba{sub 11}W{sub 4}O{sub 23} at room temperature is isostructural to the high-temperature phase at 1100 deg. C. - Graphical abstract: A slab of (0 0 1) plane around z=0 with a thickness of {approx}5.0 A for Ba{sub 11}W{sub 4}O{sub 23}. The oxide ions and the anionic vacancies on the WO{sub 18/3} polyhedron are statistically distributed over three divided sites. Cation-vacancies are ordered in between adjoining WO{sub 18/3} polyhedra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utah FORGE: Well 16B(78)-32 DTS, RFS DSS Strain, and Absolute Strain Circulation Test Fiber Optic Data - August 2024

This dataset contains processed fiber optic measurements collected during the extended cross-well circulation test at the Utah FORGE site in August 2024. The data was acquired from the 16B(78)-32 well using distributed fiber optic sensing (DFOS) technology, including distributed temperature sensing (DTS) on multimode fiber and distributed strain sensing (DSS) measurements on single-mode fiber. The dataset includes Brillouin absolute strain, Rayleigh frequency shift (RFS) DSS strain change, RFS DSS strain change rate, and temperature (DTS) data, all stored in HDF5 format. Time coordinates are provided in UTC, and depth measurements are given in measured depth relative to the rotary kelly bushing (MD RKB) in feet. The spatial sampling on the RFS DSS strain data and the Brillouin Absolute Total Strain data is 20 cm and the spatial sampling on the DTS data is 1m. The dataset is accompanied by a report from Neubrex, which provides further documentation.

15 GEOTHERMAL ENERGY↗

Nucleation and growth of Ag islands on the (.sqroot.3 × .sqroot.3)R30° phase of Ag on Si(111)

We use scanning tunneling microscopy to measure densities and characteristics of Ag islands that form on the ({radical}3 x {radical}3)R30{sup o}-Ag phase on Si(111), as a function of deposition temperature. Nucleation theory predicts that the logarithm of island density varies linearly with inverse deposition temperature. The data show two linear regimes. At 50-125 K, islands are relatively small, and island density decreases only slightly with increasing temperature. At 180-250 K, islands are larger and polycrystalline, and island density decreases strongly with increasing temperature. At 300 K, Ag atoms can travel for distances of the order of 1 {micro}m. Assuming that Ag diffusion occurs via thermally activated motion of single atoms between adjacent sites, the data can be explained as follows. At 50-125 K, the island density does not follow conventional Arrhenius scaling due to limited mobility and a consequent breakdown of the steady-state condition for the adatom density. At {approx} 115-125 K, a transition to conventional Arrhenius scaling with critical nucleus size (i = 1) begins, and at 180-250 K, i > 1 prevails. The transition points indicate a diffusion barrier of 0.20-0.23 eV and a pairwise Ag-Ag bond strength of 0.14 eV. These energy values lead to an estimate of i {approx} 3-4 in the regime 180-250 K, where island density varies strongly with temperature.

36 MATERIALS SCIENCE↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗

Comment on Comment on “Anomalous structural recovery in the near glass transition range in a polymer glass: Data revisited in light of temperature variability in vacuum oven‐based experiments”*

Abstract Cangialosi, Alegría, and Colmenero have made a comment on a paper of ours [Polym. Eng. Sci. 2022:1–13], in which we discussed the concern that the enthalpy recovery data reported by Cangialosi and co‐workers [Phys. Rev. Lett. 2013;111(9):095701] for polystyrene aged up to 15 K below glass transition temperature was anomalous and contradicted existing experimental results from the literature over a similar range of aging conditions. Their response shifts the focus away from the raised questions about their experimental results and attempts to invalidate the data that we cited in support of our argument. Here we respond to the comment and add additional analysis that suggests the structural recovery response of glassy materials exhibits smooth behavior over the full range of measurements, up to 7 or 8 logarithmic decades. We do this by referring to the work on the intrinsic isotherm down‐jump and memory responses of poly(vinyl acetate) between 40°C and 15°C over six logarithmic decades by Kovacs [Fortsch. Hochpolym. Fo. 1963;3(1/2):394–508], the small‐strain tensile creep of poly(vinyl chloride) quenched from 90°C to 40°C (approximately 40°C below T g ) over seven logarithmic decades from Struik [Polym Eng. Sci., 1977;17:165–173], and the volume recovery behavior for aging times up to 3 months in a temperature range between 95°C and −50°C by Greiner and Schwarzl [Rheol. Acta. 1984;23(4):378–395]. We also add discussion that an isothermal aging procedure using a vacuum oven is highly vulnerable to temperature errors due to the problem of good temperature control when the heat transfer mechanism is primarily radiative.

Jin, Shuang↗

Oceanographic Conditions. 2007 - 2040. North Slope Alaska.

Complete representations of oceanographic conditions require spatial and temporal information about the significant wave height (Hs), peak wave period (Tp), wind speed, wind direction, wave direction, water level, salinity, and temperature. This data develops location-independent typologies to reduce the number of boundary conditions needed to assess nearshore oceanographic environments in both a Historical (2007-2019) and Future (2020-2040) timespan along the Alaskan North Slope. Wave information for both time spans were generated from WaveWatch III, Delft3D-FLOW, and Delft3D-WAVE simulations forced by wind conditions from reanalysis data (e.g., ASRv2 and ERA5) for the historical simulations while projected conditions were obtained from downscaled GFDL-CM3 forced under RCP8.5 conditions. Salinity was generated from GOFS 3.1 for the years between 2008-2015 and skin temperature of the ocean was obtained from ASRv2 reanalysis data for the years between 2007-2016. To identify generalized oceanographic typologies, K-means clustering was applied to the energy-weighted joint-probability distribution of Hs and Tp at six sites along the North Slope of Alaska. Distributions of wave and wind direction, wind speed, and water level associated with locaiton-indepndent centroids were assigned single values to describe a reduced order, typological rendition of offshore oceanographic conditions. These final typologies and their constituent data are provided here and can be used to evaluate the change in ocean energy over the next two decades in response to climate change and provide insight into expected consequences such as coastal erosion and flooding. A full assessment of the findings and techniques developed can be found in: Eymold, W.K., Flanary, C., Erikson, L., Nederhoff, K., Chartrand, C.C., Jones, C., Kasper, J., and Bull, D.L. Typological Representation of the Offshore Oceanographic Environment along the Alaskan North Slope. Continental Shelf Research (2022). 10.1016/j.csr.2022.104795

54 ENVIRONMENTAL SCIENCES↗

Mining Thermophile Photosynthesis Genes: A Synthetic Operon Expressing Chloroflexota Species Reaction Center Genes in Rhodobacter sphaeroides

Photosynthesis is the foundation of the vast majority of life systems, and is therefore the most important bioenergetic process on earth. The greatest diversity of photosynthetic systems is found in microorganisms. However, our understanding of the biophysical and biochemical processes that transduce light into chemical energy is derived from a relatively small subset of proteins from microbes that are amenable to cultivation, in contrast to the huge number of predicted proteins that catalyze the initial photochemical reactions deposited in databases, such as from metagenomics. We describe the use of a Rhodobacter sphaeroides laboratory strain for the expression of heterologous photosynthesis genes to demonstrate the feasibility of mining this resource, focusing on hot spring Chloroflexota gene sequences. Using a synthetic operon of genes, we produced a photochemically active complex of reaction center proteins in our biological system. We also present bioinformatic analyses of anoxygenic type II reaction center sequences from metagenomic samples collected from hot (42–90 °C) springs available through the JGI IMG database, to generate a resource of diverse sequences that are potentially adapted to photosynthesis at such temperatures. These data provide a view into the natural diversity of anoxygenic photosynthesis, through a lens focused on high-temperature environments. The approach we took to express such genes can be applied for potential biotechnology purposes as well as for studies of fundamental catalytic properties of these heretofore inaccessible protein complexes.

Chloroflexota↗

Google.org US Resource Project Update

The results from a new geothermal resource assessment of the United States, including for the first time detailed data for much of the eastern US, are summarized along with the techniques used to accomplish the assessment. Bottom hole temperature (BHT) data were incorporated in the eastern US, where conventional heat flow data is sparse, using BHT corrections and calculated conductivities from a regional lithology model; comparing results to overlapping conventional heat flow and BHT data for error calibration. A total of 5,000 points are now available in the northeast as opposed to the 1,000 used to produce the 2004 Geothermal Map of North America. Where neither heat flow or BHT data were not available, geophysical data (regional gravity and magnetics) were used as an ancillary predictor to the process for areas with sedimentary cover. The effectiveness of that process is demonstrated. This study uses the new heat flow data to improve the calculated heat in place to 10 km for the US. Based the preliminary results from this wok, the Appalachian Basin may contain some of the most favorable potential targets for EGS geothermal exploration in the eastern 1/3 of the United States and especially in eastern West Virginia, where temperatures of at least 150°C are predicted at a depth of 4.5 km in localized areas.

15 GEOTHERMAL ENERGY↗

Surface Temperature Anomalies Derived from Night Time ASTER Data Corrected for Solar and Topographic Effects, Archuleta County

This map shows areas of anomalous surface temperature in Alamosa and Saguache Counties identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2o were considered ASTER modeled "very warm modeled surface temperature" are shown in red on the map. Areas that had temperatures between 1o and 2o were considered ASTER modeled "warm modeled surface temperature" are shown in yellow on the map. This map also includes the locations of shallow temperature survey points, locations of springs or wells with favorable geochemistry, faults, transmission lines, and areas of modeled basement weakness "fairways." Note: 'o' is used in this description to represent lowercase sigma.

15 GEOTHERMAL ENERGY↗

Surface Temperature Anomalies Derived from Night Time ASTER Data Corrected for Solar and Topographic Effects, Dolores County

This map shows areas of anomalous surface temperature in Alamosa and Saguache Counties identified from ASTER thermal data and spatial based insolation model. The temperature is calculated using the Emissivity Normalization Algorithm that separate temperature from emissivity. The incoming solar radiation was calculated using spatial based insolation model developed by Fu and Rich (1999). Then the temperature due to solar radiation was calculated using emissivity derived from ASTER data. The residual temperature, i.e. temperature due to solar radiation subtracted from ASTER temperature was used to identify thermally anomalous areas. Areas that had temperature greater than 2o were considered ASTER modeled "very warm modeled surface temperature" are shown in red on the map. Areas that had temperatures between 1o and 2o were considered ASTER modeled "warm modeled surface temperature" are shown in yellow on the map. This map also includes the locations of shallow temperature survey points, locations of springs or wells with favorable geochemistry, faults, transmission lines, and areas of modeled basement weakness "fairways." Note: 'o' is used in this description to represent lowercase sigma.

15 GEOTHERMAL ENERGY↗

AGR-2 Data Qualification Report for ATR Cycle 154B

This report provides the data qualification status of Advanced Gas Reactor-2 (AGR-2) fuel irradiation experimental data from Advanced Test Reactor (ATR) Cycle 154B as recorded in the Nuclear Data Management and Analysis System (NDMAS). This is the last cycle of AGR-2 irradiation, as the test train was pulled from the ATR core during the outage portion of ATR Cycle 155A. The AGR-2 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates including new Fission Product Monitoring (FPM) downstream flows from Fission Product Monitoring System (FPMS) detectors, pressure, and moisture content), and FPMS data (release rates and release-to-birth rate ratios [R/Bs]) for each of the six capsules in the AGR-2 experiment. The final data qualification status for these data streams is determined by a Data Review Committee (DRC) comprised of AGR technical leads, Sitewide Quality Assurance (QA), and NDMAS analysts. The Data Review Committee reviewed the data acquisition process, considered whether the data met the requirements for data collection as specified in QA-approved Very High Temperature Reactor (VHTR) data collection plans, examined the results of NDMAS data testing and statistical analyses, and confirmed the qualification status of the data as given in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton{sup reg.} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200--350 F. Room temperature leak test failures have been experienced in 5 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30--48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200--300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the O-rings displayed a compression set ranging from 51--95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350--400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests that CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures is needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

42 ENGINEERING↗

FIFTH INTERIM STATUS REPORT: MODEL 9975 PCV O-RING FIXTURE LONG-TERM LEAK PERFORMANCE

A series of experiments to monitor the aging performance of Viton{reg_sign} GLT O-rings used in the Model 9975 package has been ongoing for six years at the Savannah River National Laboratory. Sixty-seven mock-ups of 9975 Primary Containment Vessels (PCVs) were assembled and heated to temperatures ranging from 200 to 450 F. They were leak-tested initially and have been tested at nominal six month intervals to determine if they meet the criterion of leaktightness defined in ANSI standard N14.5-97. Fourteen additional tests were initiated in 2008 with GLT-S O-rings heated to temperatures ranging from 200 to 400 F. High temperature aging continues for 36 GLT O-ring fixtures at 200-350 F. Room temperature leak test failures have been experienced in 6 of the GLT O-ring fixtures aging at 300 and 350 F, and in all 3 of the GLT O-ring fixtures aging at higher temperatures. No failures have yet been observed in GLT O-ring fixtures aging at 200 F for 30-48 months, which is still bounding to O-ring temperatures during storage in KAMS. High temperature aging continues for 6 GLT-S O-ring fixtures at 200-300 F. Room temperature leak test failures have been experienced in all 8 of the GLT-S O-ring fixtures aging at 350 and 400 F. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 or 300 F for 19 months. For O-ring fixtures that have failed the room temperature leak test and been disassembled, the Orings displayed a compression set ranging from 51-95%. This is significantly greater than seen to date for packages inspected during KAMS field surveillance (23% average). For GLT O-rings, service life based on the room temperature leak rate criterion is comparable to that predicted by compression stress relaxation (CSR) data at higher temperatures (350-400 F). While there are no comparable failure data yet at aging temperatures below 300 F, extrapolations of the data for GLT O-rings suggests the CSR model predictions provide a conservative prediction of service life relative to the leak rate criterion. Failure data at lower temperatures are needed to verify this apparent trend. Insufficient failure data exist currently to perform a similar comparison for GLT-S O-rings. Aging and periodic leak testing will continue for the remaining fixtures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling the First Hydrogen Direct Reduction Pilot Reactor for Ironmaking in the USA Using Finite Element Analysis and Its Validation Using Pilot Plant Trial Data

Direct reduction of hematite pellets with hydrogen (H 2 ) was used to produce directly reduced iron (DRI) in a pilot scale reactor at a pellet feed rate of 21.4 kg/h. At a steady state, operational parameters of the pilot plant (gas recycling rate and inlet temperature) along with key reactor output parameters, the pellet metallization, and the internal temperature profile of the reactor were reported for two scenarios with high recycle and low recycle rate of H 2 . Scenario 1, with a high recycle rate of 400 L/min H 2 along with external heating of 870 °C, gave an average metallization of 91.8%, while Scenario 2, with low recycle rate of 100 L/min H 2 and external heating of 850 °C gave a metallization of 67.8% due to the higher moles of H 2 available for reduction and the external energy required for the endothermic reduction reaction in Scenario 1 as compared with Scenario 2. Finite element analysis was used to build a model of the shaft reactor, which was validated against the metallization and internal temperature profile data. The average metallization values predicted by the model were very close to the metallization values obtained from the pilot plant samples, with 90.9% average metallization for Scenario 1 and 65.6% average metallization for Scenario 2. The internal temperature profiles in the lower region of the reactor obtained from the model were very close to these pilot plant data, with a maximum difference of 52.7 °C and 67.6 °C for Scenarios 1 and 2, respectively. The pilot plant reactor model was used extensively in the commissioning of the pilot plant and to predict the startup outcomes for a given set of operating parameters.

08 HYDROGEN↗