Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Laser-based conversion electron Mössbauer spectroscopy of 229 ThO 2

The exceptionally low-energy 229 Th nuclear isomeric state is expected to provide several new and powerful applications, including the construction of a robust and portable solid-state nuclear clock, perhaps contributing to a redefinition of the second, exploration of nuclear superradiance and tests of fundamental physics. Further, analogous to the capabilities of traditional Mössbauer spectroscopy, the sensitivity of the nucleus to its environment can be used to realize laser Mössbauer spectroscopy and, with it, new types of strain and temperature sensors and a new probe of the solid-state environment, all with excellent sensitivity. However, current models for examining the nuclear transition in a solid require the use of a high-bandgap, vacuum ultraviolet (VUV) transmissive host, severely limiting the applicability of these techniques. Here we report the first, to the authors’ knowledge, demonstration of laser-induced conversion electron Mössbauer spectroscopy (CEMS) of the 229 Th isomer in a thin ThO 2 sample whose bandgap (approximately 6 eV) is considerably smaller than the nuclear isomeric state energy (8.4 eV). Unlike fluorescence spectroscopy of the 229 Th isomeric transition, this technique is compatible with materials whose bandgap is less than the nuclear transition energy, opening a wider class of systems to study and the potential of a conversion-electron-based nuclear clock.

36 MATERIALS SCIENCE↗

Thermoelectric properties of SnSe nanowires with different diameters

Tin selenide (SnSe) has been the subject of great attention in the last years due to its highly efficient thermoelectricity and its possibilities as a green material, free of Pb and Te. Here, we report for the first time a thermoelectricity and transport study of individual SnSe micro- and nano-wires with diameters in the range between 130nm and 1.15μm. X-ray diffraction and transmission electron microscopy analyses confirm an orthorhombic SnSe structure with Pnma (62) symmetry group and 1:1 Sn:Se atomic ratio. Electrical and thermal conductivity and the Seebeck coeficient were measured in each individual nanowire using a specialized suspended microdevice in the 150–370K temperature range, yielding a thermal conductivity of 0.55Wm -1 K -1 at room temperature and ZT~0.156 at 370K for the 130nm diameter nanowire. The measured properties were correlated with electronic information obtained by model simulations and with phonon scattering analysis. The results confirm these structures as promising building blocks to develop efficient temperature sensors, refrigerators and thermoelectric energy converters. The thermoelectric response of the nanowires is compared with recent reports on crystalline, polycrystalline and layered bulk structures.

36 MATERIALS SCIENCE↗

Range Hood Use and Effectiveness in Reducing Indoor Air Pollution During Gas and Induction Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.

Fang, Yi↗

Development of the cryogenic system of AEgIS at CERN

The AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) experiment is located at the antiproton decelerator complex of CERN. The main goal of the experiment is to perform the first direct measurement of the Earth’s gravitational acceleration on antihydrogen atoms within 1% precision. The antihydrogen is produced in a cylindrical Penning trap by combining antiprotons with positrons. To reach the precision of 1%, the antihydrogen has to be cooled to 100 mK to reduce its random velocity. A dilution refrigerator is selected to deliver the necessary cooling capacity of 100 μW at 50 mK. The AEgIS cryogenic system basically consists of cryostats for a 1-T and for a 5-T superconducting magnet, a central region cryostat, a dilution refrigerator cryostat and a measurement cryostat with a Moiré deflectometer to measure the gravitational acceleration. In autumn 2012, the 1-T cryostat, 5-T cryostat and central region cryostat were assembled and commissioned. The apparatus is cooled down in eight days using 2500 L of liquid helium and liquid nitrogen. During operation, the average consumption of liquid helium is 150 L⋅day{sup −1} and of liquid nitrogen 5 L⋅day{sup −1}. The temperature sensors at the Penning traps measured 12 K to 18 K, which is higher than expected. Simulations show that this is caused by a bad thermalization of the trap wiring. The implementation of the sub-kelvin region is foreseen for mid-2015. The antihydrogen will be cooled down to 100 mK in an ultra-cold trap consisting of multiple high-voltage electrodes made of sapphire with gold plated electrode sectors.

43 PARTICLE ACCELERATORS↗

Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

36 MATERIALS SCIENCE↗

A nonlinear MEMS electrostatic kinetic energy harvester for human-powered biomedical devices

This article proposes a silicon-based electrostatic kinetic energy harvester with an ultra-wide operating frequency bandwidth from 1 Hz to 160 Hz. This large bandwidth is obtained, thanks to a miniature tungsten ball impacting with a movable proof mass of silicon. The motion of the silicon proof mass is confined by nonlinear elastic stoppers on the fixed part standing against two protrusions of the proof mass. The electrostatic transducer is made of interdigited-combs with a gap-closing variable capacitance that includes vertical electrets obtained by corona discharge. Below 10 Hz, the e-KEH offers 30.6 nJ per mechanical oscillation at 2 g{sub rms}, which makes it suitable for powering biomedical devices from human motion. Above 10 Hz and up to 162 Hz, the harvested power is more than 0.5 μW with a maximum of 4.5 μW at 160 Hz. The highest power of 6.6 μW is obtained without the ball at 432 Hz, in accordance with a power density of 142 μW/cm{sup 3}. We also demonstrate the charging of a 47-μF capacitor to 3.5 V used to power a battery-less wireless temperature sensor node.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microfluidic cells for the 1–10 2 MPa pressure range

Thin membrane-delimited fluid cells supporting up to 1 at (0.1 MPa) of pressure are well known and commercially available for use in vacuum chambers of electron, photon, or various particle beam microscopies or spectroscopies. Hereby, we report on the development of fluid cells capable of working at 1–10 MPa, extending the analysis domain for investigating chemical, biochemical, or physical processes at pressures of interest in chemical synthesis, underwater biochemistry studies or underground geology. We explored ways to optimize cell membranes to better resist pressure beyond simply increasing the thickness or decreasing the size of the membranes, using finite element analysis and experimental validation via membrane bulging experiments and failure statistics. Fluid cell prototypes were fabricated using ∼75 nm-thick SiN x membranes, engineered to withstand 4.7 MPa (average value), compared to regular (un-engineered) membranes withstanding only 3.4 MPa (average value). The fluid cell prototypes include eight microchannels for feeding/evacuating the fluids and applying pressure into micro-reaction chambers, two electrodes for electrochemical or conduction measurements in the sample, and a possible pressure or temperature sensor, customizable for specific experiments.

hi-pressure↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Canopy cover and microtopography control precipitation-enhanced thaw of ecosystem-protected permafrost

Abstract Northern high-latitudes are projected to get warmer and wetter, which will affect rates of permafrost thaw and mechanisms by which thaw occurs. To better understand the impact of rain, as well as other factors such as snow depth, canopy cover, and microtopography, we instrumented a degrading permafrost plateau in south-central Alaska with high-resolution soil temperature sensors. The site contains ecosystem-protected permafrost, which persists in unfavorable climates due to favorable ecologic conditions. Our study (2020–2022) captured three of the snowiest years and three of the four wettest years since the site was first studied in 2015. Average thaw rates along an across-site transect increased nine-fold from 6 ± 5 cm yr −1 (2015–2020) to 56 ± 12 cm yr −1 (2020–2022). This thaw was not uniform. Hummock locations, residing on topographic high points with relatively dense canopy, experienced only 8 ± 9 cm yr −1 of thaw, on average. Hollows, topographic low points with low canopy cover, and transition locations, which had canopy cover and elevation between hummocks and hollows, thawed 44 ± 6 cm yr −1 and 39 ± 13 cm yr −1 , respectively. Mechanisms of thaw differed between these locations. Hollows had high warm-season soil moisture, which increased thermal conductivity, and deep cold-season snow coverage, which insulated soil. Transition locations thawed primarily due to thermal energy transported through subsurface taliks during individual rain events. Most increases in depth to permafrost occurred below the ∼45 cm thickness seasonally frozen layer, and therefore, expanded existing site taliks. Results highlight the importance of canopy cover and microtopography in controlling soil thermal inputs, the ability of subsurface runoff from individual rain events to trigger warming and thaw, and the acceleration of thaw caused by consecutive wet and snowy years. As northern high-latitudes become warmer and wetter, and weather events become more extreme, the importance of these controls on soil warming and thaw is likely to increase.

54 ENVIRONMENTAL SCIENCES↗

Impact of remanent magnetic field on the heat load of original CEBAF cryomodule

The heat load of the original cryomodules for the CEBAF accelerator is ~50% higher than the target value of 100 W at 2.07 K for refurbished cavities operating at an accelerating gradient of 12.5 MV/m. This issue is due to the quality factor of the cavities being ~50% lower in the cryomodule than when tested in a vertical cryostat, even at low RF field. Previous studies were not conclusive about the origin of the additional losses. We present the results of a systematic study of the additional losses in a five-cell cavity from a decommissioned cryomodule after attaching components, which are part of the cryomodule, such as the cold tuner, the He tank and the cold magnetic shield, prior to cryogenic testing in a vertical cryostat. Flux-gate magnetometers and temperature sensors are used as diagnostic elements. Different cool-down procedures and tests in different residual magnetic fields were investigated during the study. Here, three flux-gate magnetometers attached to one of the cavities installed in the refurbished cryomodule C50-12 confirmed the hypothesis of high residual magnetic field as a major cause for the increased RF losses.

43 PARTICLE ACCELERATORS↗

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗

OPET Hardware (Open PV Electrical Tool Hardware) [SWR-25-42]

OPET (Open-source Photovoltaic Electrical Tool) is used for performance measurements of solar photovoltaic (PV) devices in the field under natural sunlight or in the lab under artificial light. Its primary use is in research and development of solar cells and modules, specifically in reliability and durability research of PV devices. Some features and functions include: -IV curve measurements with linear or cosine distributed measurement points -PV device active loading at open circuit voltage (Voc), short circuit current (Isc) and maximum power point (Pmp) -Bias power supply to overcome series resistance in contact wires for Isc measurements and loading -PV voltage input in five ranges from 1V to 100V -PV current input ranges -Low current version, six current ranges from 1.1mA to 340mA -High current version, six current ranges from 50mA to 15A -IO ports for I2C and SPI temperature sensor Arduino extension boards -Integrated fan control This repository contains everything relating to the hardware of the OPET device. If you are looking for the firmware or software repositories, links are below: https://github.com/NREL/opet-firmware https://github.com/NREL/opet-control

McDanold, Byron [National Renewable Energy Laborat↗

Development and Implementation of an Automatic Continuous Online Monitoring and Control Platform for Polymerization Reactions to Sharply Boost Energy and Resource Efficiency in Polymer Manufacturing

The project goal was to create an energy saving paradigm shift in how polymers are manufactured in the 21st century. It used Automatic Continuous Online Monitoring of Polymerization reactions (ACOMP) integrated for the first time with automatic active control to create the innovative ‘ACOMP/Control Interface’, or ‘ACOMP/CI’. ACOMP/CI will begin the transformation from old, inefficient processes into highly evolved, energy and resource efficient ones. The ACOMP platform is broadly applicable to many types of reactions and processes throughout the vast polymer industry. The industry provides materials for sectors such as automotive, aerospace, oil recovery, agriculture, paints, resins, adhesives, pharmaceuticals and therapeutic proteins, optics, electronics, lightweight building materials, and many more. The U.S. chemical industry is one of the last major sectors in which the U.S. has top global stature. It consumes 24% of all U.S. manufacturing energy, produces over $800B of product annually, supports 25% of the U.S. GDP and employs over 6 million people. It is also a major source of GHG emissions. Polymers make up approximately 30% of this sector. It is estimated that annually 60 TBtu of energy could be saved and 3 million tons less of GHG emissions produced by optimizing production in the polyolefin manufacturing sector alone. The project scope included first time design and prototyping of an ACOMP/CI, creation of active reaction controllers, and demonstration of control capabilities on ideal, low concentration polymerization reactions. All these elements of the scope were met, including advances and findings not originally anticipated. Extensions to more complex reactions, beyond the reactor capabilities of the current project ACOMP/CI, such as polyolefins and other high pressure/high temperature reactions, are being proposed in Fall 2017 to CESMII, a DoE based NNMI. The initial proposal was for a three year funded project, but this was reduced to a two year project and budget due to funding constraints. Hence, some of the original plans, such as adaptation of the ACOMP/CI to more relevant industrial processes, such as emulsion and dispersion technologies, could not be carried out. A third year of funding was requested at the end of the project, but DoE did not have resources to grant this. The sub-contractor Fluence Analytics (previously Advanced Polymer Monitoring Technologies, Inc) designed, prototyped, and commissioned a working ACOMP/CI by June 2015. The reaction characteristics to be automatically controlled were i) conversion kinetics, ii) molecular weight, iii) copolymer composition, and iv) simultaneous molecular weight and composition. A two pronged control strategy was used. The Tulane/Fluence group took a basic principles approach that did not rely on kinetic models. The LSU group took a more complex, non-linear model-oriented approach involving complete kinetic descriptions of the reaction system Each of these approaches proved successful in their own way. By April 2016 fully automatic control of conversion and weight average molecular weight, Mw, trajectories was achieved using the Tulane/Fluence (TF) basic principles controller. Similar results were obtained by the LSU non-linear model controller by August 2016. The demonstration system was aqueous free radical polymerization of acrylamide, Am. The control variables were temperature and semi-batch feed to the reactor of Am monomer and initiator. A demonstration of active manual conversion control in an industrial process using high solids in inverse emulsion polymerization of Am was achieved. During Summer 2016 the TF controller was used in conjunction with a chain transfer agent, another control variable, to automatically produce multi-modal molecular weight distributions, MWD, in a single reactor. Industrially, multi-modal MWD are produced by mixing products made in separate reactors, requiring significant extra time, energy, and reactor resources. Recognizing the industrial potential a patent on automatic production of multi-modal polymers was filed, and DoE acknowledged. In Fall 2016 the TF team developed a basic principles controller for copolymer composition and demonstrated it on aqueous free radical copolymerization of comonomers Am and styrene sulfonate, SS. TF then fused the Mw and composition controllers to achieve simultaneous control of both Mw and copolymer composition trajectories. Numerous simultaneous trajectories were demonstrated, including a trimodal composition distribution with constant Mw. Meanwhile, the LSU group developed a Kalman filter to improve the results of their automatic Mw and conversion controller and successful tests were made. During the project the TF team developed a means of computing full MWD during polymer synthesis without need for any chromatographic separation, based on model distributions. This means the polymer product is ‘born characterized’ and this can eliminate post-manufacture analytical laboratory quality control. TF filed a joint patent application on this new approach to chromatography-free determination of MWD with acknowledgment to DoE. The Tulane group obtained a 60MHz NMR during the project and recently completed the first work on separating three comonomers, Am, SS, and Na-acrylate, with a first demonstration of terpolymer composition control with the TF basic principles controller. Widespread dissemination of ACOMP/CI in the polymer manufacturing sector will bolster DoE goals of energy efficiency and reduced GHG emissions: The ability to monitor and actively control polymerization reactions will lead to more efficient use of energy and non-renewable resources, plant and labor time, increase the safety of manufacturing personnel, and will enhance product quality and lead to feasibility of manufacturing of polymers currently too complex for industrial scale production, while leading to less GHG emissions per kilo of product, and allowing for increased U.S. competitiveness in this enormous manufacturing sector. When ACOMP/CI is expanded to the polyolefin industry it is estimated that 60 TeraBTU/year of energy can be saved. Much of this saving is anticipated to come from optimized control of grade changeovers in steady state reactors and maintenance of steady states. Conclusions: ACOMP’s ability to provide continuous realtime data streams of measured polymer and reaction characteristics made it possible, for the first time, to directly and automatically control free radical polymerization reactions. An industrial client of Fluence Analytics has requisitioned the first ACOMP/CI which uses the TF basic principles controller. This sets the stage for FA to add control features to the ACOMP systems it has begun to install on the industrial scale beginning in 2014. Recommendations: This successful project was mainly limited to ideal polymerizations not of an industrial sort. The most energy intensive portion of polymer manufacturing is polyolefins. Adoption of ACOMP/CI to this enormous industrial sector faces the enormous challenges of high temperature, high pressure continuous sampling and high temperature sensor operation to obtain the continuous data needed for direct reaction control. The project team has a strategy for achieving this ambitious goal and will present it in Fall 2017 as a proposal to CESMII/DoE. It is recommended that this upcoming proposal be funded in order to make full use of the achievements of this just ended DoE project as the next step towards making polyolefin ACOMP/CI an energy saving reality. It is projected that ACOMP/CI can have its first polyolefin testbed demonstrations within two years of beginning the proposed project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas Final Technical Report

Exhaust control is critical for sustained and safe operation of magnetic confinement fusion (MCF), which requires bolometers to measure the radiations converted from the exhaust power. Traditional bolometers are based on a radiation absorber and a resistive temperature sensor and their performance is greatly compromised by the strong electromagnetic interference (EMI). Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. However, it shows relatively large noise that limits its usefulness in MCF applications. In this project, we reduced the noise by more than 20 times through novel sensor design and signal demodulation. The availability of such bolometers will help to better understand and control the exhaust control strategies in MCF. The original project duration was three years. Because the PI moved to another institution on 1/1/2018, the project was closed after four months and a new grant was awarded to the PI in his new institution to continue the work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Hydraulic Experimental Test Article: Status Report for FY2019

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, the secondary system in the 18-inch Test Vessel #6, and its sodium-to-air heat exchanger will occupy the location for 18-inch Test Vessel #5 (Test Vessel #5 will not be installed), Figure 2. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Hydraulic Experimental Test Article - Status Report for FY2019 (Rev. 1)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in an SFR. High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. The design work for the facility has been completed and is currently in the procurement, manufacturing and initial testing stage. The THETA primary system, including the redan, inlet and outlet plenum, 38 kW electric core simulant heater, submerged flowmeter, pump, and all instrumentation has either been procured or is currently being tested at Argonne. The secondary sodium system for cooling the tube-side sodium of the intermediate heat exchanger has all been analyzed according to ASME code and is in the final development stages before procurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Battery Monitoring System

The component that is powered by the battery pack being monitored is a valuable asset and must be in working condition at all times. Battery chemistry and characteristics have a major role in how to evaluate the state of the battery. The battery monitoring system has many parts that lead to an accurate battery reading. The components consist of a coulomb counting device, end of life voltage detection, a consideration of use for a real-time clock (RTC), temperature sensor, and non-volatile random-access memory (NVRAM). The combination of these elements allows the monitoring system to be highly reliant. Moving forward a better implementation of the ideas in this paper and further testing should ensure a high-quality battery monitoring system.

25 ENERGY STORAGE↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗