Search NASA⌕ Search

SEARCH · Search NASA

Results for “test correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Single-drop impact damage prediction for low density, coated ceramic materials

A technique utilizing finite element analysis, liquid impact kinematics, and momentum theory is described and compared to single-drop impact test data performed on various configurations of coated ceramic material. The method correlates well with test data and is useful in predicting the single-drop impact damage velocity threshold for low-density, coated ceramic materials.

Mustelier, D.↗

Static strain and vibration characteristics of a metal semimonocoque helicopter tail cone of moderate size

The results are presented of an analytic and experimental research program involving a Sikorsky S-55 helicopter tail cone directed ultimately to the improved structural analysis of airframe substructures typical of moderate sized helicopters of metal semimonocoque construction. Experimental static strain and dynamic shake-testing measurements are presented. Correlation studies of each of these tests with a PC-based finite element analysis (COSMOS/M) are described. The tests included static loadings at the end of the tail cone supported in the cantilever configuration as well as vibrational shake-testing in both the cantilever and free-free configurations.

Bielawa, Richard L.↗

A Comparison Between The NORCAT Rover Test Results and the ISRU Excavation System Model Predictions Results

An Excavation System Model has been written to simulate the collection and transportation of regolith on the moon. The calculations in this model include an estimation of the forces on the digging tool as a result of excavation into the regolith. Verification testing has been performed and the forces recorded from this testing were compared to the calculated theoretical data. The Northern Centre for Advanced Technology Inc. rovers were tested at the NASA Glenn Research Center Simulated Lunar Operations facility. This testing was in support of the In-Situ Resource Utilization program Innovative Partnership Program. Testing occurred in soils developed at the Glenn Research Center which are a mixture of different types of sands and whose soil properties have been well characterized. This testing is part of an ongoing correlation of actual field test data to the blade forces calculated by the Excavation System Model. The results from this series of tests compared reasonably with the predicted values from the code.

Gallo, Christopher A.↗

Development of High-Resolution Soil Hydraulic Parameters with Use of Earth Observations for Enhancing Root Zone Soil Moisture Product

Regional quantification of energy and water balance fluxes depends inevitably on the estimation of surface and rootzone soil moisture. The simulation of soil moisture depends on the soil retention characteristics, which are difficult to estimate at a regional scale. Thus, the present study proposes a new method to estimate high-resolution Soil Hydraulic Parameters (SHPs) which in turn help to provide high-resolution (spatial and temporal) rootzone soil moisture (RZSM) products. The study is divided into three phases—(I) involves the estimation of finer surface soil moisture (1 km) from the coarse resolution satellite soil moisture. The algorithm utilizes MODIS 1 km Land Surface Temperature (LST) and 1 km Normalized difference vegetation Index (NDVI) for downscaling 25 km C-band derived soil moisture from AMSR-2 to 1 km surface soil moisture product. At one of the test sites, soil moisture is continuously monitored at 5, 20, and 50 cm depth, while at 44 test sites data were collected randomly for validation. The temporal and spatial correlation for the downscaled product was 70% and 83%, respectively. (II) In the second phase, downscaled soil moisture product is utilized to inversely estimate the SHPs for the van Genuchten model (1980) at 1 km resolution. The numerical experiments were conducted to understand the impact of homogeneous SHPs as compared to the three-layered parameterization of the soil profile. It was seen that the SHPs estimated using the downscaled soil moisture (I-d experiment) performed with similar efficiency as compared to SHPs estimated from the in-situ soil moisture data (I-b experiment) in simulating the soil moisture. The normalized root mean square error (nRMSE) for the two treatments was 0.37 and 0.34, respectively. It was also noted that nRMSE for the treatment with the utilization of default SHPs (I-a) and AMSR-2 soil moisture (I-c) were found to be 0.50 and 0.43, respectively. (III) Finally, the derived SHPs were used to simulate both surface soil moisture and RZSM. The final product, RZSM which is the daily 1 km product also showed a nearly 80% correlation at the test site. The estimated SHPs are seen to improve the mean NSE from 0.10 (I-a experiment) to 0.50 (I-d experiment) for the surface soil moisture simulation. The mean nRMSE for the same was found to improve from 0.50 to 0.31.

soil moisture downscaling↗

Using Multi-shaker Force Control Methods in Modal Analysis

Shaker excitation is a popular technique in experimental modal analysis because it gives the practitioner a high level of control and repeatability in the excitation. However, the dynamics of the shaker and test article can fundamentally limit the excitation bandwidth when a voltage-mode amplifier is used to power the shaker. Further, multiple shakers can couple to one-another through the test article and correlate the forces during a multiple-input / multiple-output modal test, potentially impa

Carter, Steven Phillip↗

Validation of a Mesoscale Fiber Kinking Model Through Test and Analysis of Double Edge Notch Compression Specimens

Tests and analyses were conducted on a series of geometrically-scaled double edge notch compression specimens to validate the capability of the fiber-kinking model in the NASA continuum damage mechanics code for progressive damage analysis, CompDam. The tests and analyses focused on the fiber-kinking damage mechanism, which is of critical importance for predicting accurately longitudinal compression failure in carbon fiber reinforced polymer laminates. The fiber-kinking model in CompDam was augmented with a new capability to represent a hardening response once a kink band has fully formed, enabling prediction of band broadening. Correlation of the test and analysis results showed agreement in stiffness and strength with less than 10% error. The analysis predicts the same sequence of events leading to ultimate failure that was found in the test. The overall excellent correlation in terms of stiffness, strength, and failure process validates the capability of the model for predicting longitudinal compression failure in notched laminates with cross-ply layups.

Bergan, Andrew C.↗

Spectro-Photometer for the History of the Universe, Epoch of Reionization, and Ices Explorer, One Quarter Scale Prototype Thermal Testing

The Spectro-Photometer for the History of the Universe, Epoch of Reionization, and Ices Explorer (SPHEREx) instrument has been proposed as NASA Small Explorer (SMEX) and Medium Explorer (MIDEX) missions designed to perform an all-sky near-infrared survey. The primary science objective of the SPHEREx instrument is the mapping and cataloging of data on galaxy red shifts and absorption spectra. The SPHEREx instrument utilizes a linear variable band pass filter to provide discrete spectral coverage of the 0.75 to 5.0 μm range. The nominal on-orbit mission lifetime for the instrument is two years with continuous primary science imaging. The SPHEREx instrument will be placed in a near-circular LEO sun-synchronous terminator orbit with a mean altitude of 600 km, and solar beta angles ranging from 59° to 90°. A passive V-groove radiator cooling system was selected for the SPHEREx instrument. This design was chosen for its simplicity and lack of vibration. It includes five radiator stages with the coldest two stages providing temperatures below 80K and 55K for the 2.5μm and 5.3μm detectors respectively. A one quarter scale thermal prototype was constructed to characterize the performance of the SPHEREx thermal control subsystem. This prototype was directly derived and scaled from the current flight design, and accurately replicates all heat flow paths at scale. The prototype was tested in two bounding hot flight-like environments in the Cryogenic Systems Engineering, Advanced Thermal Technology Lab at NASA’s Jet Propulsion Laboratory. Following testing, a previously developed one quarter scale thermal model was correlated to the two conditions seen in test. The resultant correlated model is able to predict the prototype test temperatures to within 1K for all critical radiator stages. An overview of the thermal control design approach, the test configuration, and test and correlation results are presented.

Bolton, Douglas A.↗

Test for Cosmological Parity Violation Using the 3D Distribution of Galaxies

Here we show how the galaxy four-point correlation function can test for cosmological parity violation. The detection of cosmological parity violation would reflect previously unknown forces present at the earliest moments of the Universe. Recent developments both in rapidly evaluating galaxy N-point correlation functions and in determining the corresponding covariance matrices make the search for parity violation in the four-point correlation function possible in current and upcoming surveys such as those undertaken by Dark Energy Spectroscopic Instrument, the Euclid satellite, and the Vera C. Rubin Observatory. We estimate the limits on cosmic parity violation that could be set with these data.

79 ASTRONOMY AND ASTROPHYSICS↗

Analyses of flight model spacecraft performance during thermal-vacuum tests

Malfunction data from the thermal-vacuum tests of 39 flight-model spacecraft were analyzed. The results are interpreted in terms of the test variables, and in terms of the spacecraft performance. The malfunction data are correlated with the test time as a single variable, and also with the composite variable of time plus temperature. The improvement in spacecraft performance is examined by means of malfunction rates, malfunctions per spacecraft, and the probability of no failure related to test time. The minimum thermal-vacuum test profile required for Goddard Space Flight Center spacecraft is verified, and the probability of a defect remaining undetected is estimated.

Timmins, A. R.↗

Oxidation of Carbon Fibers in Water Vapor Studied

T-300 carbon fibers (BP Amoco Chemicals, Greenville, SC) are a common reinforcement for silicon carbide composite materials, and carbon-fiber-reinforced silicon carbide composites (C/SiC) are proposed for use in space propulsion applications. It has been shown that the time to failure for C/SiC in stressed oxidation tests is directly correlated with the fiber oxidation rate (ref. 1). To date, most of the testing of these fibers and composites has been conducted in oxygen or air environments; however, many components for space propulsion, such as turbopumps, combustors, and thrusters, are expected to operate in hydrogen and water vapor (H2/H2O) environments with very low oxygen contents. The oxidation rate of carbon fibers in conditions representative of space propulsion environments is, therefore, critical for predicting component lifetimes for real applications. This report describes experimental results that demonstrate that, under some conditions, lower oxidation rates of carbon fibers are observed in water vapor and H2/H2O environments than are found in oxygen or air. At the NASA Glenn Research Center, the weight loss of the fibers was studied as a function of water pressure, temperature, and gas velocity. The rate of carbon fiber oxidation was determined, and the reaction mechanism was identified.

Opila, Elizabeth J.↗

Investigation of correlation between full-scale and fifth-scale wind tunnel tests of a Bell helicopter Textron Model 222

Reasons for lack of correlation between data from a fifth-scale wind tunnel test of the Bell Helicopter Textron Model 222 and a full-scale test of the model 222 prototype in the NASA Ames 40-by 80-foot tunnel were investigated. This investigation centered around a carefully designed fifth-scale wind tunnel test of an accurately contoured model of the Model 222 prototype mounted on a replica of the full-scale mounting system. The improvement in correlation for drag characteristics in pitch and yaw with the fifth-scale model mounted on the replica system is shown. Interference between the model and mounting system was identified as a significant effect and was concluded to be a primary cause of the lack of correlation in the earlier tests.

Squires, P. K.↗

TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20 minutes for film-based methods. The techniques introduced can potentially isolate errors in individual joints of the CK robot. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wire Crimp Termination Verification Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.

Perey, Daniel F.↗