Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Method and apparatus for temperature-gradient aware data-placement for 3D stacked DRAMs

A system including a stack of two or more layers of volatile memory, such as layers of a 3D stacked DRAM memory, places data in the stack based on a temperature or a refresh rate. When a threshold is exceeded, data are moved from a first region to a second region in the stack, the second region having one or both of a second temperature lower than a first temperature of the first region or a second refresh rate lower than a first refresh rate of the first region.

97 MATHEMATICS AND COMPUTING↗

Capture and decay of electroweak WIMPonium

The spectrum of Weakly-Interacting-Massive-Particle (WIMP) dark matter generically possesses bound states when the WIMP mass becomes sufficiently large relative to the mass of the electroweak gauge bosons. The presence of these bound states enhances the annihilation rate via resonances in the Sommerfeld enhancement, but they can also be produced directly with the emission of a low-energy photon. In this work we compute the rate for SU(2) triplet dark matter (the wino) to bind into WIMPonium—which is possible via single-photon emission for wino masses above 5 TeV for relative velocity v < O (10{sup −2}) —and study the subsequent decays of these bound states. We present results with applications beyond the wino case, e.g. for dark matter inhabiting a nonabelian dark sector; these include analytic capture and transition rates for general dark sectors in the limit of vanishing force carrier mass, efficient numerical routines for calculating positive and negative-energy eigenstates of a Hamiltonian containing interactions with both massive and massless force carriers, and a study of the scaling of bound state formation in the short-range Hulth and apos;(e)n potential. In the specific case of the wino, we find that the rate for bound state formation is suppressed relative to direct annihilation, and so provides only a small correction to the overall annihilation rate. The soft photons radiated by the capture process and by bound state transitions could permit measurement of the dark matter's quantum numbers; for wino-like dark matter, such photons are rare, but might be observable by a future ground-based gamma-ray telescope combining large effective area and a low energy threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding the Roles of Convective Trigger Functions in the Diurnal Cycle of Precipitation in the NCAR CAM5

The wrong diurnal cycle of precipitation is a common weakness of current global climate models (GCMs). To improve the simulation of the diurnal cycle of precipitation and understand what physical processes control it, we test a convective trigger function described in Xie et al. (2019) with additional optimizations in the NCAR Community Atmosphere Model version 5 (CAM5). The revised trigger function consists of three modifications: 1) replacing the Convective Available Potential Energy (CAPE) trigger with a dynamic CAPE (dCAPE) trigger, 2) allowing convection to originate above the top of planetary boundary layer (i.e., the unrestricted air parcel launch level - ULL), and 3) optimizing the entrainment rate and threshold value of the dynamic CAPE generation rate for convection onset based on observations. Results from 1°-resolution simulations show that the revised trigger can alleviate the long-standing GCM problem of too early maximum precipitation during the day and missing the nocturnal precipitation peak that is observed in many regions, including the U.S. southern Great Plains (SGP). The revised trigger also improves the simulation of the propagation of precipitation systems downstream of the Rockies and the Amazon region. A further composite analysis over the SGP unravels the mechanisms through which the revised trigger affects convection. Additional sensitivity tests show that both the peak time and the amplitude of the diurnal cycle of precipitation are sensitive to the entrainment rate and dCAPE threshold values.

54 ENVIRONMENTAL SCIENCES↗

SU-C-BRA-02: Gradient Based Method of Target Delineation On PET/MR Image of Head and Neck Cancer Patients

Purpose: Validate the consistency of a gradient-based segmentation tool to facilitate accurate delineation of PET/CT-based GTVs in head and neck cancers by comparing against hybrid PET/MR-derived GTV contours. Materials and Methods: A total of 18 head and neck target volumes (10 primary and 8 nodal) were retrospectively contoured using a gradient-based segmentation tool by two observers. Each observer independently contoured each target five times. Inter-observer variability was evaluated via absolute percent differences. Intra-observer variability was examined by percentage uncertainty. All target volumes were also contoured using the SUV percent threshold method. The thresholds were explored case by case so its derived volume matched with the gradient-based volume. Dice similarity coefficients (DSC) were calculated to determine overlap of PET/CT GTVs and PET/MR GTVs. Results: The Levene’s test showed there was no statistically significant difference of the variances between the observer’s gradient-derived contours. However, the absolute difference between the observer’s volumes was 10.83%, with a range from 0.39% up to 42.89%. PET-avid regions with qualitatively non-uniform shapes and intensity levels had a higher absolute percent difference near 25%, while regions with uniform shapes and intensity levels had an absolute percent difference of 2% between observers. The average percentage uncertainty between observers was 4.83% and 7%. As the volume of the gradient-derived contours increased, the SUV threshold percent needed to match the volume decreased. Dice coefficients showed good agreement of the PET/CT and PET/MR GTVs with an average DSC value across all volumes at 0.69. Conclusion: Gradient-based segmentation of PET volume showed good consistency in general but can vary considerably for non-uniform target shapes and intensity levels. PET/CT-derived GTV contours stemming from the gradient-based tool show good agreement with the anatomically and metabolically more accurate PET/MR-derived GTV contours, but tumor delineation accuracy can be further improved with the use PET/MR.

60 APPLIED LIFE SCIENCES↗

Reshock analysis for PMMA driven above the threshold for chemical decomposition

Polymethyl methacrylate (PMMA) is a transparent thermoplastic often used in shock compression science. Previous proceedings (AIP Conf. Proc. 845, 131 (2006)) described plate impact experiments in which PMMA was reshocked to pressures of up to ~130 GPa, well above that at which it decomposes on its principal Hugoniot. Because some of the conclusions of the original analysis were surprising, the results were reanalyzed in a later proceeding (ibid. 1426, 771 (2012)). In addition to our own reanalysis of the data, we performed hydrodynamic simulations of the experiments based on a new equation of state for PMMA shocked above its threshold for decomposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of measurement and simulation of ATLAS cavern radiation background

Sixteen Medipix2 pixel detector based (MPX) devices were operated at various positions within the ATLAS detector and cavern continuously from early 2008 up to 2013. In addition to photons, each MPX detector is capable to detect charged particles, and neutrons as it is covered with a mask of converter materials dividing its area into regions sensitive to thermal or fast neutrons. The MPX detector network was effectively used for real-time measurements of the spectral characteristics and composition of complex radiation fields in ATLAS. This article reports comparison of the results of measurements performed with MPX detectors during the LHC operation period in 2010 and 2011 with Monte Carlo simulations results from the FLUGG and GCALOR codes. For the purpose of this comparison, the MPX detectors were operated in tracking mode with low threshold (8–10 keV) allowing one to distinguish among particle categories based on the recognition of track patterns left by the particles in the MPX sensitive layer. The comparison of measurements with simulations shows that the agreement between measured and simulated data is satisfactory in most cases within a factor of two.

47 OTHER INSTRUMENTATION↗

COMPARISON OF SIMULATION CODES FOR MICROWAVE INSTABILITY IN BUNCHED BEAMS

In accelerator design, there is often a need to evaluate the threshold to the (longitudinal) microwave instability for a bunched beam in an electron storage ring. Several computational tools are available that allow them, once given the wakefield representing a ring, to numerically find the threshold current and to simulate the development of the instability. In this work, they present results of coputer simulations using two codes recently developed at the SLAC National Accelerator Laboratory: a Vlasov-Fokker-Planck (VFP) solver based on an algorithm by Warnock and Ellison, and a program that find the threshold from the linearized Vlasov equation. They apply the programs to find the instability threshold for three models of ring impedances: that of a Q = 1 resonator, of shielded coherent synchrotron radiation (CSR), and of a resistive wall. The first example is wel-bheaved, but the other two are singular wakes that need special care. Note that similar numerical studies of the threshold of a Q = 1 resonantor wake have been performed by Oide and Yokova, and others. They compare the results of the two programs and discuss their respective capabilities and limitations. In this report they assume the slippage factor {eta} is always positive. They work in Gaussian units.

43 PARTICLE ACCELERATORS↗

On the consistency of Monte Carlo track structure DNA damage simulations

Purpose: Monte Carlo track structures (MCTS) simulations have been recognized as useful tools for radiobiological modeling. However, the authors noticed several issues regarding the consistency of reported data. Therefore, in this work, they analyze the impact of various user defined parameters on simulated direct DNA damage yields. In addition, they draw attention to discrepancies in published literature in DNA strand break (SB) yields and selected methodologies. Methods: The MCTS code Geant4-DNA was used to compare radial dose profiles in a nanometer-scale region of interest (ROI) for photon sources of varying sizes and energies. Then, electron tracks of 0.28 keV–220 keV were superimposed on a geometric DNA model composed of 2.7 × 10{sup 6} nucleosomes, and SBs were simulated according to four definitions based on energy deposits or energy transfers in DNA strand targets compared to a threshold energy E{sub TH}. The SB frequencies and complexities in nucleosomes as a function of incident electron energies were obtained. SBs were classified into higher order clusters such as single and double strand breaks (SSBs and DSBs) based on inter-SB distances and on the number of affected strands. Results: Comparisons of different nonuniform dose distributions lacking charged particle equilibrium may lead to erroneous conclusions regarding the effect of energy on relative biological effectiveness. The energy transfer-based SB definitions give similar SB yields as the one based on energy deposit when E{sub TH} ≈ 10.79 eV, but deviate significantly for higher E{sub TH} values. Between 30 and 40 nucleosomes/Gy show at least one SB in the ROI. The number of nucleosomes that present a complex damage pattern of more than 2 SBs and the degree of complexity of the damage in these nucleosomes diminish as the incident electron energy increases. DNA damage classification into SSB and DSB is highly dependent on the definitions of these higher order structures and their implementations. The authors’ show that, for the four studied models, different yields are expected by up to 54% for SSBs and by up to 32% for DSBs, as a function of the incident electrons energy and of the models being compared. Conclusions: MCTS simulations allow to compare direct DNA damage types and complexities induced by ionizing radiation. However, simulation results depend to a large degree on user-defined parameters, definitions, and algorithms such as: DNA model, dose distribution, SB definition, and the DNA damage clustering algorithm. These interdependencies should be well controlled during the simulations and explicitly reported when comparing results to experiments or calculations.

60 APPLIED LIFE SCIENCES↗

Photodissociation resonances of jet-cooled NO{sub 2} at the dissociation threshold by CW-CRDS

Around 398 nm, the jet-cooled-spectrum of NO{sub 2} exhibits a well identified dissociation threshold (D{sub 0}). Combining the continuous-wave absorption-based cavity ringdown spectroscopy technique and laser induced fluorescence detection, an energy range of ∼25 cm{sup −1} is analyzed at high resolution around D{sub 0}. In addition to the usual molecular transitions to long-lived energy levels, ∼115 wider resonances are observed. The position, amplitude, and width of these resonances are determined. The resonance width spreads from ∼0.006 cm{sup −1} (i.e., ∼450 ps) to ∼0.7 cm{sup −1} (∼4 ps) with large fluctuations. The identification of at least two ranges of resonance width versus the excess energy can be associated with the opening of the dissociation channels NO{sub 2}→NO(X {sup 2}Π{sub 1/2}, v=0, J=1/2)+O({sup 3}P{sub 2}) and NO{sub 2}→NO(X {sup 2}Π{sub 1/2}, v=0, J=3/2)+O({sup 3}P{sub 2}). This analysis corroborates the existence of loose transition states close to the dissociation threshold as reported previously and in agreement with the phase space theory predictions as shown by Tsuchiya’s group [Miyawaki et al., J. Chem. Phys. 99, 254–264 (1993)]. The data are analyzed in the light of previously reported frequency- and time-resolved data to provide a robust determination of averaged unimolecular dissociation rate coefficients. The density of reactant levels deduced (ρ{sub reac} ∼ 11 levels/cm{sup −1}) is discussed versus the density of transitions, the density of resonances, and the density of vibronic levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the limits of waveform correlation event detection as applied to three earthquake aftershock sequences.

Swarms of earthquakes and/or aftershock sequences can dramatically increase the level of seismicity in a region for a period of time lasting from days to months, depending on the swarm or sequence. Such occurrences can provide a large amount of useful information to seismologists. For those who monitor seismic events for possible nuclear explosions, however, these swarms/sequences are a nuisance. In an explosion monitoring system, each event must be treated as a possible nuclear test until it can be proven, to a high degree of confidence, not to be. Seismic events recorded by the same station with highly correlated waveforms almost certainly have a similar location and source type, so clusters of events within a swarm can quickly be identified as earthquakes. We have developed a number of tools that can be used to exploit the high degree of waveform similarity expected to be associated with swarms/sequences. Dendro Tool measures correlations between known events. The Waveform Correlation Detector is intended to act as a detector, finding events in raw data which correlate with known events. The Self Scanner is used to find all correlated segments within a raw data steam and does not require an event library. All three techniques together provide an opportunity to study the similarities of events in an aftershock sequence in different ways. To comprehensively characterize the benefits and limits of waveform correlation techniques, we studied 3 aftershock sequences, using our 3 tools, at multiple stations. We explored the effects of station distance and event magnitudes on correlation results. Lastly, we show the reduction in detection threshold and analyst workload offered by waveform correlation techniques compared to STA/LTA based detection. We analyzed 4 days of data from each aftershock sequence using all three methods. Most known events clustered in a similar manner across the toolsets. Up to 25% of catalogued events were found to be a member of a cluster. In addition, the Waveform Correlation Detector and Self Scanner identified significant numbers of new events that were not in either the EDR or regional catalogs, showing a lowering of the detection threshold. We extended our analysis to study the effect of distance on correlation results by applying the analysis tools to multiple stations along a transect of nearly constant azimuth when possible. We expected the number of events found via correlation would drop off as roughly 1/r2, where r is the distance from mainshock to station. However, we found that regional geological conditions influenced the performance of a given station more than distance. For example, for one sequence we clustered 25% of events at the nearest station to the mainshock (34 km), while our performance dropped to 2% at a station 550 km distant. However, we matched our best performance (25% clustering) at a station 198 km distant.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Life-Cycle Assessment of Energy and Environmental Impacts of LED Lighting Products, Part 3: LED Environmental Testing

This report covers the third part of a larger U.S. Department of Energy (DOE) project to assess the life- cycle environmental and resource impacts associated with the manufacturing, transport, use, and disposal of light-emitting diode (LED) lighting products in relation to incumbent lighting technologies. All three reports are available on the DOE website (www.ssl.energy.gov/tech_reports.html). Part 1: Review of the Life-Cycle Energy Consumption of Incandescent, Compact Fluorescent and LED Lamps; Part 2: LED Manufacturing and Performance; Part 3: LED Environmental Testing. Parts 1 and 2 were published in February and June 2012, respectively. The Part 1 report included a summary of the life-cycle assessment (LCA) process and methodology, provided a literature review of more than 25 existing LCA studies of various lamp types, and performed a meta-analysis comparing LED lamps with incandescent and compact fluorescent lamps (CFLs). Drawing from the Part 1 findings, Part 2 performed a more detailed assessment of the LED manufacturing process and used these findings to provide a comparative LCA taking into consideration a wider range of environmental impacts. Both reports concluded that the life-cycle environmental impact of a given lamp is dominated by the energy used during lamp operation—the upstream generation of electricity drives the total environmental footprint of the product. However, a more detailed understanding of end-of-life disposal considerations for LED products has become increasingly important as their installation base has grown. The Part 3 study (reported herein) was undertaken to augment the LCA findings with chemical analysis of a variety of LED, CFL, and incandescent lamps using standard testing procedures. A total of 22 samples, representing 11 different models, were tested to determine whether any of 17 elements were present at levels exceeding California or Federal regulatory thresholds for hazardous waste. Notably, this type of testing does not provide an indication of product safety during use. Key findings include: • The selected models were generally found to be below thresholds for Federally regulated elements, although volatile mercury in the CFLs is presumed to have escaped detection; • Nearly all of the lamps (regardless of technology) exceeded at least one California threshold— typically for copper, zinc, antimony, or nickel; • The greatest contributors were the metal screw bases, drivers, ballasts, and wires or filaments— internal LED light sources generally did not cause LED lamps to exceed thresholds. This study was exploratory in nature and was not intended to provide a definitive indication of regulatory compliance for any specific lamp model or technology. Further study would be needed to more broadly characterize the various light source technologies; to more accurately and precisely characterize a specific model; or to determine whether product redesign would be appropriate. However, concentrations of regulated elements in LED lamps were found to be comparable to cell phones and other types of electronic devices, which like incandescent lamps and CFLs have also have been shown to exceed the stringent California thresholds for hazardous waste. Although LED lamps offer reduced life-cycle energy and environmental impacts when compared to CFLs and incandescent lamps, recycling will likely gain importance as consumer adoption of this emerging technology continues to increase.

bulb↗

Parton distributions with threshold resummation

We construct a set of parton distribution functions (PDFs) in which fixed-order NLO and NNLO calculations are supplemented with soft-gluon (threshold) resummation up to NLL and NNLL accuracy respectively, suitable for use in conjunction with any QCD calculation in which threshold resummation is included at the level of partonic cross sections. These resummed PDF sets, based on the NNPDF3.0 analysis, are extracted from deep-inelastic scattering, Drell-Yan, and top quark pair production data, for which resummed calculations can be consistently used. We find that, close to threshold, the inclusion of resummed PDFs can partially compensate the enhancement in resummed matrix elements, leading to resummed hadronic cross-sections closer to the fixed-order calculations. On the other hand, far from threshold, resummed PDFs reduce to their fixed-order counterparts. Our results demonstrate the need for a consistent use of resummed PDFs in resummed calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automated aortic calcium scoring on low-dose chest computed tomography

Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm{sup 3} out of 965 mm{sup 3} (97.9%) calcified plaque volume in the aorta with an average of 64 mm{sup 3} of false positive volume per scan. Spearman rank correlation coefficient was {rho}=0.960 between the system and the first observer compared to {rho}=0.961 between the two observers. Conclusions: Automatic calcium scoring in the aorta thus appears feasible with good correlation between manual and automatic scoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structured sequences emerge from random pool when replicated by templated ligation

The central question in the origin of life is to understand how structure can emerge from randomness. The Eigen theory of replication states, for sequences that are copied one base at a time, that the replication fidelity has to surpass an error threshold to avoid that replicated specific sequences become random because of the incorporated replication errors [M. Eigen, Naturwissenschaften 58 (10), 465–523 (1971)]. Here, we showed that linking short oligomers from a random sequence pool in a templated ligation reaction reduced the sequence space of product strands. We started from 12-mer oligonucleotides with two bases in all possible combinations and triggered enzymatic ligation under temperature cycles. Surprisingly, we found the robust creation of long, highly structured sequences with low entropy. At the ligation site, complementary and alternating sequence patterns developed. However, between the ligation sites, we found either an A-rich or a T-rich sequence within a single oligonucleotide. Our modeling suggests that avoidance of hairpins was the likely cause for these two complementary sequence pools. What emerged was a network of complementary sequences that acted both as templates and substrates of the reaction. This self-selecting ligation reaction could be restarted by only a few majority sequences. The findings showed that replication by random templated ligation from a random sequence input will lead to a highly structured, long, and nonrandom sequence pool. This is a favorable starting point for a subsequent Darwinian evolution searching for higher catalytic functions in an RNA world scenario.

60 APPLIED LIFE SCIENCES↗

Interactions between Polyelectrolyte Gel Surfaces

We see surfaces formed by charged polymeric species are highly abundant in both synthetic and biological systems, for which maintaining an optimum contact distance and a pressure balance is paramount. Here we investigate interactions between surfaces of two same-charged and highly swollen polyelectrolyte gels, using extensive molecular dynamic simulations and minimal analytical methods. The external-pressure responses of the gels and the polymer-free ionic solvent layer separating two surfaces are considered. Simulations confirmed that the surfaces are held apart by osmotic pressure resulting from excess charges diffusing out of the network. At a threshold pressure, the counterion-induced osmotic pressure in the gel interiors becomes nearly equal to that in solvent gap, and the gels begin to deform. At the threshold pressure, the distance between surfaces is equivalent to the electrostatic screening length imposed by excess charges. Both the solvent layer and pressure dependence are well described by an analytical model based on the Poisson–Boltzmann solution for low and moderate electrostatic strengths. Scaling descriptions for the threshold pressure and critical distance compare well with the simulations. The threshold pressure decreases with increasing polymerization degree of network chains, similar to sparsely grafted polyelectrolyte brushes. As the electrostatic coupling strength is increased, the deviations from the analytical model also increase due to condensed counterions. Our results are of great importance for systems where charged gels or gel-like structures interact in various solvents, including systems encapsulated by gels and microgels in confinement.

36 MATERIALS SCIENCE↗

SU-C-207B-03: A Geometrical Constrained Chan-Vese Based Tumor Segmentation Scheme for PET

Purpose: Accurate segmentation of tumor in PET is challenging when part of tumor is connected with normal organs/tissues with no difference in intensity. Conventional segmentation methods, such as thresholding or region growing, cannot generate satisfactory results in this case. We proposed a geometrical constrained Chan-Vese based scheme to segment tumor in PET for this special case by considering the similarity between two adjacent slices. Methods: The proposed scheme performs segmentation in a slice-by-slice fashion where an accurate segmentation of one slice is used as the guidance for segmentation of rest slices. For a slice that the tumor is not directly connected to organs/tissues with similar intensity values, a conventional clustering-based segmentation method under user’s guidance is used to obtain an exact tumor contour. This is set as the initial contour and the Chan-Vese algorithm is applied for segmenting the tumor in the next adjacent slice by adding constraints of tumor size, position and shape information. This procedure is repeated until the last slice of PET containing tumor. The proposed geometrical constrained Chan-Vese based algorithm was implemented in Matlab and its performance was tested on several cervical cancer patients where cervix and bladder are connected with similar activity values. The positive predictive values (PPV) are calculated to characterize the segmentation accuracy of the proposed scheme. Results: Tumors were accurately segmented by the proposed method even when they are connected with bladder in the image with no difference in intensity. The average PPVs were 0.9571±0.0355 and 0.9894±0.0271 for 17 slices and 11 slices of PET from two patients, respectively. Conclusion: We have developed a new scheme to segment tumor in PET images for the special case that the tumor is quite similar to or connected to normal organs/tissues in the image. The proposed scheme can provide a reliable way for segmenting tumors.

60 APPLIED LIFE SCIENCES↗

Comparison of Standardized Uptake Value-Based Positron Emission Tomography and Computed Tomography Target Volumes in Esophageal Cancer Patients Undergoing Radiotherapy

Purpose: To study various standardized uptake value (SUV)-based approaches to ascertain the best strategy for delineating metabolic tumor volumes (MTV). Methods and Materials: Twenty-two consecutive previously treated esophageal cancer patients with positron emission tomography (PET) imaging and computed tomography (CT)-based radiotherapy plans were studied. At the level of the tumor epicenter, MTVs were delineated at 11 different thresholds: SUV {>=}2, {>=}2.5, {>=}3, {>=}3.5 (SUV{sub n}); {>=}40%, {>=}45%, and {>=}50% of the maximum (SUV{sub n%}); and mean liver SUV + 1, 2, 3, and 4 standard deviations (SUV{sub Ln{sigma}}). The volume ratio and conformality index were determined between MTVs, and the corresponding CT/endoscopic ultrasound-based gross tumor volume (GTV) at the epicenter. Means were analyzed by one-way analysis of variance for repeated measures and further compared using a paired t test for repeated measures. Results: The mean conformality indices ranged from 0.33 to 0.48, being significantly (p < 0.05) closest to 1 at SUV{sub 2.5} (0.47 {+-} 0.03) and SUV{sub L4{sigma}} (0.48 {+-} 0.03). The mean volume ratios ranged from 0.39 to 2.82, being significantly closest to 1 at SUV{sub 2.5} (1.18 {+-} 0.36) and SUV{sub L4{sigma}} (1.09 {+-} 0.15). The mean value of the SUVs calculated using the SUV{sub L4{sigma}} approach was 2.4. Conclusions: Regardless of the SUV thresholding method used (i.e., absolute or relative to liver mean), a threshold of approximately 2.5 yields the highest conformality index and best approximates the CT-based GTV at the epicenter. These findings may ultimately aid radiation oncologists in the delineation of the entire GTV in esophageal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BeZnCdSe quantum-well ridge-waveguide laser diodes under low threshold room-temperature continuous-wave operation

Low threshold current ridge-waveguide BeZnCdSe quantum-well laser diodes (LDs) have been developed by completely etching away the top p-type BeMgZnSe/ZnSe:N short-period superlattice cladding layer, which can suppress the leakage current that flows laterally outside of the electrode. The waveguide LDs are covered with a thick SiO{sub 2} layer and planarized with chemical-mechanical polishing and a reactive ion etching process. Room-temperature lasing under continuous-wave condition is achieved with the laser cavity formed by the cleaved waveguide facets coated with high-reflectivity dielectric films. For a 4 μm-wide green LD lasing around a wavelength of 535 nm, threshold current and voltage of 7.07 mA and 7.89 V are achieved for a cavity length of 300 μm, and the internal differential quantum efficiency, internal absorption loss, gain constant, and nominal transparency current density are estimated to be 27%, 4.09 cm{sup −1}, 29.92 (cm × μm)/kA and 6.35 kA/(cm{sup 2 }× μm), respectively. This compact device can realize a significantly improved performance with much lower threshold power consumption, which would benefit the potential application for ZnSe-based green LDs as light sources in full-color display and projector devices installed in consumer products such as pocket projectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗