Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D CT scans”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

63 records · Page 4

X-ray Computed Tomography Data of Dense Metallic Components

The data shared in here are X-ray computed tomography (XCT) scans of a hexagonal fuel nozzle in 3 sections with the Metrotom 800 system at the Manufacturing Demonstration Facility (MDF) at Oak Ridge National Laboratory. The data are used in the paper "Tomographic Sparse View Selection using the View Covariance Loss, by Lin et al. (doi:10.1109/TPAMI.2025.36000720), accepted to the international conference on computational imaging (ICCP 2025). Figures 4-7 in the paper describe the part/XCT scan. File name Descriptions: Bottom section: TCR- Single Channeled SRC L 2019-3-18 12-26-41.hdf5 Medium section: TCR- Single Channeled SRC M 2019-3-18 13-8-9.hdf5 Top section: TCR- Single Channeled SRC T 2019-3-18 13-45-39.hdf5 Each hdf5 file contains projection data, and all the relevant X-ray CT scan setting. The full list of included attributes: distance_unit: Units of all distances specified angle_unit : Units of the angles angles: Array of all angles used voxel_size_xy: Baseline recon (if any) has this voxel size in the in-plane direction voxel_size_z: Baseline recon (if any) has this voxel size in the cross-plane direction det_pixel_size_col: Size of the detector pixels in the column dimension det_pixel_size_row: Size of the detector pixels in the row dimension src_iso_dist: Source to iso-center distance iso_det_dist: Iso-center to detector distance det_angle: If the detector is rotated/tilted, this angle corresponds to that value det_row_offset: Center of rotation offset in the vertical direction det_col_offset: Center of rotation offset in the horizontal direction reconstruction: A baseline reconstruction stored as 3D array BHC params: Beam-hardening parameters - Van De Casteel Model - if it has been used to pre-process the projections We also provided a python script (hdf_io.py) that allows the user to read the relevant data from each hdf5 file.

Ziabari, Amir [Oak Ridge National Laboratory]↗

Pore-scale observations of natural hydrate-bearing sediments via pressure core sub-coring and micro-CT scanning

Abstract Both intra-pore hydrate morphology and inter-pore hydrate distribution influence the physical properties of hydrate-bearing sediments, yet there has been no pore-scale observations of hydrate habit under pressure in preserved pressure core samples so far. We present for the first time a pore-scale micro-CT study of natural hydrate-bearing cores that were acquired from Green Canyon Block 955 in UT-GOM2-1 Expedition and preserved within hydrate pressure–temperature stability conditions throughout sub-sampling and imaging processes. Measured hydrate saturation in the sub-samples, taken from units expected to have in-situ saturation of 80% or more, ranges from 3 ± 1% to 56 ± 11% as interpreted from micro-CT images. Pore-scale observations of gas hydrate in the sub-samples suggest that hydrate in silty sediments at the Gulf of Mexico is pore-invasive rather than particle displacive, and hydrate particles in these natural water-saturated samples are pore-filling with no evidence of grain-coating. Hydrate can form a connected 3D network and provide mechanical support for the sediments even without cementation. The technical breakthrough to directly visualize particle-level hydrate pore habits in natural sediments reported here sheds light on future investigations of pressure- and temperature-sensitive processes including hydrate-bearing sediments, dissolved gases, and other biochemical processes in the deep-sea environment.

58 GEOSCIENCES↗

The use of subchondral bone topography to approximate the center of rotation of the elbow joint in dogs

Abstract Objectives The aim of this study was to compare the approximate center of rotation in normal and diseased elbows in dogs. Study design Cross‐sectional study Sample population Computer tomography scans of nine dogs with unilateral fragmented medial coronoid process (FMCP). Methods A board certified radiologist confirmed that each dog had unilateral FMCP, and a normal contralateral elbow. Digital 3D models of all elbow joints were uploaded into a surgical planning software package. Four axes approximating the center of rotation (COR) of elbow joints were generated using five geometric shapes based on subchondral topography of the humeral condyle radius and ulna. Images showing the locations where axes exited the medial and lateral cortex of the humeral condyle were captured and imported into a second software package, for measurement of distances between exit points and the origin of a system of axes. Results In normal joints 20/27 (74%) axes exited the medial cortex, and 25/27 (93%) axes exited the lateral cortex cranial and distal to the medial and lateral epicondyles, respectively. In diseased joints 22/27 (81%) axes exited medial cortex and 19/27 (70%) axes exited the lateral cortex, caudal and distal to the medial and lateral epicondyles, respectively. Conclusion Based on CT‐ derived geometry, the COR of elbow affected with FMCP was generally more caudal than normal. Clinical significance External landmarks approximating the location of the elbow COR are provided, and while not validated, may assist in planning, creation, and assessment of procedures for FMCP.

Berger, Chen↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

Multiscale Modeling of Reconstructed Tricalcium Silicate using NASA Multiscale Analysis Tool

To study microstructure characteristics of cementitious materials hydrated in space; previously, cement binder formations were processed under microgravity conditions and was further compared against ground-based experiments. For accurate estimation of process-structure-property linkage, particularly on samples hydrated in the microgravity environment, it is desired to have a high-fidelity volumetric representation of the microstructure. However, owing to small sample size and high porosity of the space-returned samples, conventional experimental characterization techniques are not viable. Hence, a deep learning-based reconstruction algorithm was employed to obtain high fidelity 3D volumes from sparse high resolution 2D Scanning Electron Microscopy (SEM) images, as inputs to micromechanics-based modeling. This machine learning-based reconstruction methodology validated against low-order statistical descriptors, captured the microstructural topology of both sample types (ground, 1g and microgravity, μg). Due to the lack of gravity, hydration products of the samples processed in space differed from those processed-on ground. Such AI-generated virtual samples were analyzed in a multiscale recursive micromechanics approach using the NASA Multiscale Analysis Tool (NASMAT). Here, we present a methodology to rapidly integrate and evaluate these AI-generated volumes in NASMAT. The synthesized microstructural volumes are directly employed as Representative Volume Elements (RVEs) to preserve the fidelity (1 pixel = 0.54 m). Invariably, analysis of such largescale problems (5123 voxels) requires huge amount of computational resources. By taking advantage of the NASMAT architecture, we also focused on systematic multiscale integration of these AI-reconstructed virtual volumes to reduce the computational demands. In this work, this methodology is demonstrated on the ground-based, 1g samples. The estimated stiffness value of 15.90 GPa is comparable to experimentally obtained modulus of hydrated tricalcium silicate sample. The workflow presented here paves the way for utilizing the NASMAT tool to perform multiscale analyses of other multi-phase material systems using either 3D virtual datasets synthesized using AI or obtained via micro-CT.

Machine Learning↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

Multiscale porosity characterization in additively manufactured polymer nanocomposites using micro-computed tomography

Extrusion-based additive manufacturing (AM) of polymer composites exhibits complex thermally driven phenomena that introduce severe discontinuities in the internal structure across length scales, especially voids or porosity. This study utilizes a high-throughput porosity characterization technique to analyze large datasets from numerous micro-computed tomography (mu CT) scans to capture the influence of AM print parameters on the size, shape, and location of porosity across multiple print layers (up to a few cm) on fused granular fabrication (FGF) printers. The materials investigated include nanocomposite formulations based on commercially relevant nylon-12 and polyether ketone ketone (PEKK) materials comprising nano- or micro- sized fillers. The estimated global porosity follows an inverse linear correlation against the bulk density of the printed samples. Increasing the extrusion multiplier (EM) and the nozzle temperature while decreasing the print speeds reduces the global porosity. Outlier analyses (local porosity morphology) show that faster print speeds and higher extrusion rates result in long, slender inter-layer voids, while lower nozzle temperatures lead to large, symmetrical, inter-bead voids (at the bead junction). Lack of active chamber temperature increases inter-layer and intra-bead voids with a two-fold increase in global porosity. Overall, the micro filler-reinforced composites exhibit higher global porosity than nanofiller-reinforced composites, which is attributed to the increased mismatch in the thermal expansion coefficient between the filler and the polymers used in the study.

36 MATERIALS SCIENCE↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Non-destructive simulation of node defects in additively manufactured lattice structures

Additive Manufacturing (AM), commonly referred to as 3D printing, offers the ability to not only fabricate geometrically complex lattice structures but parts in which lattice topologies in-fill volumes bounded by complex surface geometries. However, current AM processes produce defects on the strut and node elements which make up the lattice structure. This creates an inherent difference between the as-designed and as-fabricated geometries, which negatively affects predictions (via numerical simulation) of the lattice’s mechanical performance. Although experimental and numerical analysis of an AM lattice’s bulk structure, unit cell and struts have been performed, there exists almost no research data on the mechanical response of the individual as-manufactured lattice node elements. Here we propose a methodology that, for the first time, allows non-destructive quantification of the mechanical response of node elements within an as-manufactured lattice structure. A custom-developed tool is used to extract and classify each individual node geometry from micro-computed tomography scans of an AM fabricated lattice. Voxel-based finite element meshes are generated for numerical simulation and the mechanical response distribution is compared to that of the idealised computer-aided design model. The method demonstrates compatibility with Uncertainty Quantification methods that provide opportunities for efficient prediction of a population of nodal responses from sampled data. Overall, the non-destructive and automated nature of the node extraction and response evaluation is promising for its application in qualification and certification of additively manufactured lattice structures.

36 MATERIALS SCIENCE↗