Search NASASearch

SEARCH · Search NASA

Results for “4D STEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

66 records · Page 4

Radiation-induced vacancy injection in heterogeneous multiphase materials

Understanding the synergy between corrosion and defect dynamics is a key consideration in the development of advanced materials for extreme environments. Here, we reveal a surprising phenomenon for the transport of point defects induced by irradiation in a heterogeneous multiphase structure of a metal and an oxide, similar to that formed under metal corrosion that takes place in most environments. Despite the confinement of the produced damage within the oxide, vacancies were injected into the unirradiated metal and coarsened with dose. Furthermore, the results show that the nature of the oxide layer dictates the defect evolution in the metal layer. This work reveals an interesting mechanism for point defect interactions in multiphase materials, with broad implications in many fields, while also emphasizing the complex coupling between corrosion and irradiation. Corrosion leads to the formation of multiphase materials, while irradiation enhances diffusion within the heterogeneous phases, which can impact corrosion rates.

36 MATERIALS SCIENCE

Atomically resolved edges and defects in lead halide perovskites

Although edges and defects constitute only a small fraction of crystalline materials, they exert an outsized impact on a material′s properties. Organic–inorganic halide perovskites are promising next-generation semiconductor materials with superior cost effectiveness and interesting optoelectronic properties. However, clear images of their edges have remained challenging to obtain owing to their extreme sensitivity. Using truly high-speed ultralow-dose four-dimensional scanning transmission electron microscopy with dose fractionation, we perform ptychography at, to our knowledge, the lowest-dose atomic resolution to date, revealing not only the detailed atomic structure of the edges of a halide perovskite but also their structural dynamics. Here, a majority methylammonium (MA) and iodine (I) edge termination is observed in methylammonium lead iodide (MAPbI 3 ), and the damage rate of its edges and internal defects is found to depend on the concentration and type of vacancies present, with a preponderance of I vacancies in particular correlating with higher rates of damage.

4D-STEM

Real-space visualization of a defect-mediated charge density wave transition

Here, we study the coupled charge density wave (CDW) and insulator-to-metal transitions in the 2D quantum material 1T-TaS 2 . By applying in situ cryogenic 4D scanning transmission electron microscopy with in situ electrical resistance measurements, we directly visualize the CDW transition and establish that the transition is mediated by basal dislocations (stacking solitons). We find that dislocations can both nucleate and pin the transition and locally alter the transition temperature T c by nearly ~75 K. This finding was enabled by the application of unsupervised machine learning to cluster five-dimensional, terabyte scale datasets, which demonstrate a one-to-one correlation between resistance—a global property—and local CDW domain-dislocation dynamics, thereby linking the material microstructure to device properties. This work represents a major step toward defect-engineering of quantum materials, which will become increasingly important as we aim to utilize such materials in real devices.

4D-STEM

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION

Streaming Large-Scale Microscopy Data to a Supercomputing Facility

Data management is a critical component of modern experimental workflows. As data generation rates increase, transferring data from acquisition servers to processing servers via conventional file-based methods is becoming increasingly impractical. The 4D Camera at the National Center for Electron Microscopy generates data at a nominal rate of 480 Gbit s -1 (87,000 frames s -1 ⁠), producing a 700 GB dataset in 15 s. To address the challenges associated with storing and processing such quantities of data, we developed a streaming workflow that utilizes a high-speed network to connect the 4D Camera’s data acquisition system to supercomputing nodes at the National Energy Research Scientific Computing Center, bypassing intermediate file storage entirely. In this work, we demonstrate the effectiveness of our streaming pipeline in a production setting through an hour-long experiment that generated over 10 TB of raw data, yielding high-quality datasets suitable for advanced analyses. Additionally, we compare the efficacy of this streaming workflow against the conventional file-transfer workflow by conducting a postmortem analysis on historical data from experiments performed by real users. Our findings show that the streaming workflow significantly improves data turnaround time, enables real-time decision-making, and minimizes the potential for human error by eliminating manual user interactions.

4D-STEM

Exploring Structural Anisotropy in Amorphous Tb-Co via Changes in Medium-Range Ordering

Amorphous thin films grown by magnetron co-sputtering exhibit changes in atomic structure with varying growth and annealing temperatures. Structural variations influence the bulk properties of the films. Scanning nanodiffraction performed in a transmission electron microscope (TEM) is applied to amorphous Tb 17 Co 83 (a-Tb-Co) films deposited over a range of temperatures to measure relative changes in medium-range ordering (MRO). These measurements reveal an increase in MRO with higher growth temperatures and a decrease in MRO with higher annealing temperatures. The trend in MRO indicates a relationship between the growth conditions and local atomic ordering. By tilting select films, the TEM measures variations in the local atomic structure as a function of orientation within the films. The findings support claims that preferential ordering along the growth direction results from temperature-mediated adatom configurations during deposition, and that oriented MRO correlates with increased structural anisotropy, explaining the strong growth-induced perpendicular magnetic anisotropy found in rare earth–transition metal films. Beyond magnetic films, we propose the tilted FEM workflow as a method of extracting anisotropic structural information in a variety of amorphous materials with directionally dependent bulk properties, such as films with inherent bonding asymmetry grown by physical vapor deposition.

36 MATERIALS SCIENCE

Super-Resolution Ptychography with Small Segmented Detectors

To overcome the spatial resolution limit set by aperture-limited diffraction in traditional scanning transmission electron microscopy, microscopists have developed ptychography enabled by iterative phase retrieval algorithms and high-dynamic-range pixel array detectors. Current detector designs are limited by the data rate off chip, so a high-pixel-count detector has a proportionally lower frame rate than the few-segment detectors used for differential phase contrast (DPC) imaging. This slower acquisition speed leads to heightened vulnerability to scan noise, drift, and potential sample damage. This creates opportunities for repurposing fast segmented detectors for ptychography by trading a reduction in reciprocal space pixels for an increase in real space pixels. Here, we explore a strategy of oversampling in real space and instead apply detector pixel upsampling during the reconstruction process. Further, we demonstrate the viability of achieving super-resolution ptychography on thin objects using only 2 × 2 detector pixels, surpassing the resolution of integrated DPC (iDPC) imaging. With optimization using simulated datasets and experiments on MoTe 2 /WSe 2 bilayer moiré superlattices, we achieved super-resolution ptychography reconstructions under rapid acquisition conditions (37.5 pA, 1 μs dwell time), yielding over 50% improvements in contrast and information limit compared to annular dark field and iDPC imaging on the same detectors.

2D materials

Quantitative Structure Determination from Experimental Four-Dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix

Considerable inroads have recently been made on algorithms to determine the sample potential from four-dimensional scanning transmission electron microscopy data from thick samples where multiple scattering cannot be neglected. This paper further develops the scattering matrix approach to such structure determination. Through simulation, we demonstrate how this approach can be modified to better handle partial spatial coherence, unknown probe defocus, and information from the dark field region. By combining these developments we reconstruct the electrostatic potential of a monolithic SrTiO 3 crystal showing good quantitative agreement with the expected structure.

4D STEM

Nion Swift FY2021 phase I Final Technical Report DE-SC0021546

Phase I of the project is an on-going success. The enhanced and extended new application programming interface (API) developed in Phase I is in use at customer sites around the world: Berlin, UK, US, China, France, Austria. The modules developed to demonstrate the new API features are in daily use at these sites for acquiring, processing, and analyzing microscopy data from 4D- and 5D-STEM to single-point spectroscopy at highest resolution.

Lovejoy, Tracy

Time Resolution Characterization of 4H-SiC LGADs with a 90 Sr Source

This work presents timing measurements of 4H-SiC Low Gain Avalanche Detectors (4H-SiC LGADs) using beta particles from a 90Sr source. The 4H-SiC LGADs exhibit fast signal responses, and a time resolution of 61 ps was achieved, comparable to that of standard Si LGADs. The present limitation in the time resolution of 4H-SiC LGADs appears to stem from limited charge generation. Nevertheless, their higher voltage tolerance and faster carrier drift suggest that, with increased charge collection, their timing performance could approach or even surpass that of Si LGADs. Furthermore, these results demonstrate the strong potential of 4H-SiC LGADs as a robust platform for precision timing in future 4D tracking detectors, while also highlighting that signal charge is the dominant factor currently limiting their performance, indicating that further optimization of gain and drift structures will be essential for future development.

43 PARTICLE ACCELERATORS

NASA Tech Briefs, June 2011

Topics covered include: Wind and Temperature Spectrometry of the Upper Atmosphere in Low-Earth Orbit; Health Monitor for Multitasking, Safety-Critical, Real-Time Software; Stereo Imaging Miniature Endoscope; Early Oscillation Detection Technique for Hybrid DC/DC Converters; Parallel Wavefront Analysis for a 4D Interferometer; Schottky Heterodyne Receivers With Full Waveguide Bandwidth; Carbon Nanofiber-Based, High-Frequency, High-Q, Miniaturized Mechanical Resonators; Ultracapacitor-Based Uninterrupted Power Supply System; Coaxial Cables for Martian Extreme Temperature Environments; Using Spare Logic Resources To Create Dynamic Test Points; Autonomous Coordination of Science Observations Using Multiple Spacecraft; Autonomous Phase Retrieval Calibration; EOS MLS Level 1B Data Processing Software, Version 3; Cassini Tour Atlas Automated Generation; Software Development Standard Processes (SDSP); Graphite Composite Panel Polishing Fixture; Material Gradients in Oxygen System Components Improve Safety; Ridge Waveguide Structures in Magnesium-Doped Lithium Niobate; Modifying Matrix Materials to Increase Wetting and Adhesion; Lightweight Magnetic Cooler With a Reversible Circulator; The Invasive Species Forecasting System; Method for Cleanly and Precisely Breaking Off a Rock Core Using a Radial Compressive Force; Praying Mantis Bending Core Breakoff and Retention Mechanism; Scoring Dawg Core Breakoff and Retention Mechanism; Rolling-Tooth Core Breakoff and Retention Mechanism; Vibration Isolation and Stabilization System for Spacecraft Exercise Treadmill Devices; Microgravity-Enhanced Stem Cell Selection; Diagnosis and Treatment of Neurological Disorders by Millimeter-Wave Stimulation; Passive Vaporizing Heat Sink; Remote Sensing and Quantization of Analog Sensors; Phase Retrieval for Radio Telescope and Antenna Control; Helium-Cooled Black Shroud for Subscale Cryogenic Testing; Receive Mode Analysis and Design of Microstrip Reflectarrays; and Chance-Constrained Guidance With Non-Convex Constraints.

Source record