Search NASA⌕ Search

SEARCH · Search NASA

Results for “AC grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Models and methods for assessing the value of HVDC adn MVDC technologies in modern power grids (Annual Report, Executive Summary)

Evolution of today’s predominantly alternating current (ac) transmission grid in to mixed ac transmission – high-voltage direct current (HVdc) systems is expected with the decreasing costs of and advancements in power electronics technologies. The recent technological advancements include the development of more efficient and compact voltage source converters (VSCs) that can provide fast response. Because of their controllability and fast response, HVdc systems provide the ability to enhance reliability of the ac transmission grid through frequency support, voltage control, and congestion relief. The HVdc systems can also provide other ancillary services to enhance the economics and reliability of the ac transmission grids, and to optimize their performance. The tools, models, and methods developed to evaluate their benefits will be key enablers to understanding the value proposition introduced by the fast-acting HVdc systems. The main motivation of this work was to develop models and methods to explore and quantify the technical and economic benefits of HVdc systems and fast response VSC technologies in the future grid of United States. The models and methods explore the benefits of HVdc systems through provision of controlled active/reactive power and fast response. The fast response can provide much-needed multiobjective services to the grid (e.g., frequency response, voltage control) while moving blocks of energy. The models and methods can be applied to study other power electronics technologies and scenarios such as those undertaken in ongoing studies led by the North American Electric Reliability Corporation (NERC) Inverter-based Resource Performance Task Force (IRPTF). The IRPTF studies identify the problems associated with power electronics-based technologies as they are integrated in to the bulk power system (or the ac transmission system).

24 POWER TRANSMISSION AND DISTRIBUTION↗

AC and DC Hybrid Distribution Grids with Solar Integration: Architecture, Stabilization and Cost Assessment

In this project, a holistic analysis of architecture, stabilization, and cost/efficiency analysis in hybrid AC and DC distribution grids are conducted. Particularly, versatile and cost-efficient multiport converters are developed to not only integrate solar sources and other DERs in DC grids, but also facilitate the interactive operation of DC sub-grids and conventional AC distribution grids. Meanwhile, a universal and extended impedance-based stabilization approach with a decentralized and adaptive virtual impedance loop is developed in hybrid AC and DC distribution grids, which comprehensively covers the active stabilization of DC sections, AC sections, and interface inverters interlinking both AC and DC sections. Furthermore, to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and quantify the improvement of hybrid AC and DC grids over conventional pure AC grids, the project team develops an alpha-version tool to monitor and calculate the efficiency and cost of the DC, AC, or hybrid AC and DC grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart-PGSim: Using Neural Network to Accelerate AC-OPF Power Grid Simulation

In this work we address the problem of accelerating complex power-grid simulation through machine learning ( ML). Specifically, we develop a framework, Smart-PGSim,which generates multitask-learning (MTL) neural network (NN)models to predict the initial values of variables critical to the problem convergence. MTL models allow information sharing when predicting multiple dependent variables while including customized layers to predict individual variables. We show that,to achieve the required accuracy, it is paramount to embed domain-specific constraints derived from the specific power-grid components in the MTL model. Smart-PGSim then employs the predicted initial values as a high-quality initial condition for the power-grid numerical solver (warm start), resulting in both higher performance compared to state-of-the-art solutions while maintaining the required accuracy. Smart-PGSim brings 2.60×speedup on average (up to 3.28×) computed over 10,000 problems, without losing solution optimality.

machine learning, neural networks↗

1 kV, 10-kW SiC-Based Quadruple Active Bridge DCX Stage in a DC to Three-Phase AC Module for Medium-Voltage Grid Integration

Interfacing low voltage dc to medium voltage three-phase ac grid is often based on series-stackable modular converter architectures. To minimize energy storage requirements, it is advantageous to employ a quadruple active bridge (QAB) stage operating as a "dc transformer" in each stackable module. The QAB stage offers three isolated dc link voltages, which then allow for flexible stacking of three single-phase dc-to-ac inverter stages. Each of the module phases processes a pulsating power having a component at twice the line frequency. This presents a challenge in maintaining zero voltage switching (ZVS) on the secondary sides of the QAB during low-power portions of the line cycle. This article is focused on the design of the QAB stage. A detailed analysis of ZVS switching waveforms is presented, including effects of nonlinear device capacitances. It is shown how ZVS can be achieved at all times using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. Analytical expressions are given for the optimal values of the magnetizing inductance and the dead times of the QAB primary and secondary bridges. This approach is verified by experimental results on a 1 kV, 10-kW SiC-based prototype, demonstrating a relatively flat efficiency curve with a peak efficiency of 97.1% at 75% load.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Single-Stage Multilevel AC-DC Bidirectional Converter With Natural Grid Harmonic Elimination

Generally, AC-DC converters have an AC-DC stage followed by a DC-DC stage. In these two stage approaches, the AC-DC stage is hard-switched, whereas the DC-DC stage is soft-switched. Therefore, the devices in the AC-DC stage can be switched only at tens of kHz to avoid excessive switching losses, thus limiting the bandwidth of the current control loop. Hence, the control of these converters with distorted grid voltages requires multiple harmonic compensation loops or other complex control algorithms in order for the grid currents to comply with IEEE standards. By integrating both the stages, the devices in the AC-DC stage can also be soft-switched, thus facilitating higher switching frequency, and thereby higher current control bandwidth. This paper proposes an integrated multilevel bidirectional AC-DC converter with improved control bandwidth and disturbance rejection. It is shown experimentally that the high bandwidth current control loop of the converter can reject grid harmonic current disturbances, without the need for any compensation loops or complex control techniques, and comply with IEEE standards.

30 DIRECT ENERGY CONVERSION↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Scale Power Router: Dynamic Control of Grid Assets Using Direct AC Converter Cells

ADEPT Project: Georgia Tech is developing a cost-effective, utility-scale power router that uses an enhanced transformer to more efficiently direct power on the grid. Existing power routing technologies are too expensive for widespread use, but the ability to route grid power to match real-time demand and power outages would significantly reduce energy costs for utilities, municipalities, and consumers. Georgia Tech is adding a power converter to an existing grid transformer to better control power flows at about 1/10th the cost of existing power routing solutions. Transformers convert the high-voltage electricity that is transmitted through the grid into the low-voltage electricity that is used by homes and businesses. The added converter uses fewer steps to convert some types of power and eliminates unnecessary power storage, among other improvements. The enhanced transformer is more efficient, and it would still work even if the converter fails, ensuring grid reliability.

ADEPT↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

25 ENERGY STORAGE↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

25 ENERGY STORAGE↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid regulation services for energy storage devices based on grid frequency

Disclosed herein are representative embodiments of methods, apparatus, and systems for charging and discharging an energy storage device connected to an electrical power distribution system. In one exemplary embodiment, a controller monitors electrical characteristics of an electrical power distribution system and provides an output to a bi-directional charger causing the charger to charge or discharge an energy storage device (e.g., a battery in a plug-in hybrid electric vehicle (PHEV)). The controller can help stabilize the electrical power distribution system by increasing the charging rate when there is excess power in the electrical power distribution system (e.g., when the frequency of an AC power grid exceeds an average value), or by discharging power from the energy storage device to stabilize the grid when there is a shortage of power in the electrical power distribution system (e.g., when the frequency of an AC power grid is below an average value).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Permanent Magnet Synchronous Motors for Commercial Refrigeration (Final Report)

This report provides background information on various fractional-horsepower electric motor technologies used for evaporator fan applications in commercial refrigeration and summarizes data from a DOE-sponsored evaporator fan motor laboratory and field demonstration project. This report also extrapolates that data to project the potential economic and environmental benefits resulting from upgrading the current installed base of commercial refrigeration evaporator fan motors to permanent magnet synchronous (PMS) motors.Evaporator fan motors used in commercial refrigeration applications are fractional horsepower in size, responsible for moving air across the evaporator coil, and typically run at one speed. Historically, shaded-pole induction motors have been the most commonly used evaporator fan motors in commercial refrigeration equipment and beverage vending machines. These are the simplest and least expensive type of fractional-horsepower motor, with an efficiency of approximately 20%. Electronically commutated (EC) permanent magnet motors, also known as brushless DC motors, were initially commercialized in the late 1980s, and their use in commercial refrigeration applications has increased within the last 10 to 15 years because of economic incentives and regulatory requirements. State-of-the-art EC motors are approximately 66% efficient. Another induction motor type, the permanent split capacitor (PSC) motor, offers a mid-point between shaded-pole and EC motor price and efficiency levels. PSC motors are typically about 29% efficient.A permanent magnet synchronous (PMS) AC motor that can directly use grid-supplied AC current without the need to rectify to DC has recently been commercialized. This new motor exhibits a peak efficiency of 75% and has the potential to significantly reduce the energy consumption of evaporator fan motors in commercial refrigeration equipment. Laboratory evaluation of evaporator fan motor technologies was performed to quantify and compare the performance of shaded-pole, PSC, EC, and PMS evaporator fan motors in a controlled environment, so as to minimize the influence of external factors and anomalies. The laboratory evaluation included dynamometer testing of the fan motors and airflow testing of the motor/fan assemblies. It was found that the 6–12 W PMS motor exhibited a peak efficiency of 75% with a power factor of approximately 0.9 at a power output of 11 W. It was also found that a 38–50 W PMS motor exhibited a peak efficiency of 82% with a power factor of approximately 0.9 at a power output of 35 W.Airflow testing of shaded-pole, PSC, EC, and PMS motor/fan assemblies was performed using an airflow test chamber, which was designed in accordance with ANSI/AMCA Standard 210-16/ASHRAE Standard 51-16, to measure the performance of the subject motor/fan assembly and to determine the incumbent display case system impedance (AMCA 2016). A family of fan curves (static pressure vs airflow rate and electrical power input vs airflow rate) was generated for the 6–12 W PMS motor/fan assemblies with 8-inch fan blades pitched from 17 to 32 degrees. A similar set of curves was generated for the 38–50 W motors paired with 10 and 12-inch blades. Various incumbent motor/fan assemblies were also tested in the laboratory airflow test chamber and their fan curves were generated.Field evaluation of refrigerated display case evaporator fan motors was accomplished by performing side-by-side comparisons of 6–12 W PMS motors to 6–12 W shaded-pole and EC evaporator fan motors. It was found that, on average, a PMS motor consumes 79% less power and draws 82% less current than a shaded pole motor, and on average, 34% less power and 49% less current than an EC motor. In addition, the PMS motor exhibits an average power factor of approximately 0.82, which is on average 40% greater than that of existing evaporator fan motors.Two field test sites were selected to evaluate the performance of the larger 38 to 50 W PMS evaporator fan motors in walk-in cooler/freezer applications. At each supermarket, two walk-in units were selected for investigation: one walk-in dairy cooler and one walk-in freezer. A 61% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in cooler. In addition, a 48% decrease in fan motor power was measured when retrofitting existing evaporator fan motors with PMS motors in the walk-in freezer.The culmination of the field evaluation of fan motor technologies was a whole-store retrofit conducted at a supermarket. Pre- and post-retrofit measurement of evaporator fan motor power in medium- and low-temperature refrigerated display cases and walk-in coolers/freezers was performed. Overall for the whole-store retrofit, the current supplied to all monitored evaporator fan motors was reduced by 52%, the real power was reduced by 46% and the apparent power was reduced by 51% following the retrofit of the 262 evaporator fan motors that w

42 ENGINEERING↗

ADEPT Final Report: Dynamic Control of Grid Assets Using Direct AC Converter Cells

Seedling funding was secured through the ARPA-E program to develop a robust, utility-scale Power Converter Augmented Transformer (PCAT). The project designed, fabricated, and tested two 13 kV, 1 MW PCATs operating at an effective switching frequency of up to 50 kHz and at an efficiency of greater than 99%. Two versions of the PCAT were fabricated – one using an imputed DC link (IDCL) topology and the other using a back-to-back (BTB) topology. The IDCL avoids the use of electrolytic capacitors for bulk energy storage, thus improving the lifetime and decreasing the size of the converter, while the BTB topology uses an industry-proven topology that is more commercially viable in the short term. To give the PCAT a lifetime and maintenance profile compatible with typical existing utility assets, a novel Passive Thermal Management System (PTMS) was designed and integrated into both PCATs. The PTMS uses a thermosiphon to remove heat from the power electronic devices without forced cooling and reject it to the ambient environment. In addition, a fail-normal feature was implemented to ensure that in the event of PCAT failure the functionality of the underlying transformer is retained. Attainment of project objectives was verified through testing at the Georgia Tech National Electrical Energy Testing Research and Applications Center (NEETRAC). The IDCL-based PCAT had an efficiency of more than 99.10% and the BTB-based PCAT had an efficiency of more than 99.75%. During testing, the PTMS exceeded project requirements by rejecting the 5 kW output of the converters to a 40 °C environment while keeping devices junction temperatures within their tolerances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time evaluation of cybersecurity threats to DER inverter grid-support functions

In this project we aim to contribute to the understanding of the type and severity of potential cybersecurity attacks to the grid-support functionalities of DER systems interconnected to the AC distribution grid via inverters. Our preliminary work focused on developing a small-scale testbed allowing to study cybersecurity threats to an isolated photovoltaic-battery system using a real-time simulator (Typhoon HIL602+) with a real DNP3 communication connection over TCP/IP, allowing for safe and efficient monitoring and manipulation of data traffic between the simulated hardware and supervisory control and data acquisition (SCADA) system. In this project we propose to expand upon this development by utilizing a) a recently acquired NovaCor RTDS (Real Rime digital Simulator) to emulate the DER-inverter-grid topology including main grid-support functions as defined by IEEE Std. 1547-2018, and b) an industrial control and automation device to enable realistic evaluation of control functions and utilization of communication protocols for real-time data transmission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mass spectrometer has wide angular acceptance

Higher mass resolution is achieved by replacing conventional mass/velocity spectrometers with system of planar ac-modulated grids. System gives focusing for all angles of incidence. Ac-modulation and detection scheme minimizes sensitivity to light and other types of radiation.

Neugebauer, M. M.↗

Thermionic triode generates ac power

Electrostatic grid controls conduction cycle of thermionic diode to convert low dc output voltages to high ac power without undesirable power loss. An ac voltage applied to the grid of this new thermionic triode enables it to convert heat directly into high voltage electrical power.

Kniazzeh, A. G. F.↗

Root Cause Analysis of AC Overcurrent in July 2020 San Fernando Disturbance

On July 7 2020, approximately 1,000 MW reduction in solar photovoltaic (PV) output was experienced by the bulk power system in Southern California after a three-phase fault. Disturbance analysis indicates that instantaneous AC current caused inverter tripping. The projection of the root cause of AC overcurrent from the NERC report is that inverter current control is not tight. This letter provides a quantitative analysis on ac overcurrent and addresses the following questions: (i) what type of current controls may lead to ac overcurrent; and (ii) how controller parameters and grid strength influence ac overcurrent. Here, the letter provides frequency-domain analysis and time-domain simulation results of a grid-integrated inverter to illustrate the effect of control parameters and grid strength on ac overcurrent.

14 SOLAR ENERGY↗