Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Hanford single-shell tank sidewall coring Project - 15548

As part of an enhanced Single-Shell Tank (SST) integrity project, Washington River Protection Solutions, the US DOE Hanford site Tank Operations Contractor, established an expert panel to provide recommendations for implementation of the project. In one of the main areas of interest, structural integrity, the panel recommended obtaining and testing a vertical core from the entire depth of the sidewall for SSTs that have leaked and have been operated at high temperatures for extended periods. Due to concerns over handling contaminated samples, the panel later recommended that the evaluation focus only on thermal degradation. SST 241-A-106 was selected as the best choice for sidewall coring based on heat exposure and other factors. During site preparation activities, nondestructive testing and evaluation of the exposed tank dome and sidewall was performed using impact echo, spectral analysis of surface waves, and sonic echo/impulse response acoustic wave test methods. Good results were observed in the tests performed on the dome, but results were inconclusive for the full wall height due to signal damping. Results indicated that no cracking was predicted in the upper wall. Sidewall coring of tank A-106 was completed over two weeks in May 2014. Over 38 feet of concrete core was successfully removed, to a depth approximately halfway through the tank footing. Nondestructive and destructive physical testing of the concrete core specimens was successfully performed and included visual examination and determination of transverse and longitudinal resonant frequency and dynamic modulus of elasticity; pulse velocity; static modulus of elasticity; Poisson's ratio; and compressive strength. The testing indicated favorable results with values generally greater, and in many cases significantly greater, than expected in comparison with the values originally specified and those used in the current structural analysis of record. Petrographic analysis was performed to assess the quality and condition of the concrete and the extent of any deterioration or deleterious reactions occurring within the concrete, and determined that the concrete within the examined core segments is in overall good condition, with a minor amount of microcracking and minor evidence of deleterious mechanisms that do not appear to have significantly affected the overall quality and integrity of the concrete. The results of the testing performed on the concrete core removed from the sidewall of SST 241-A-106 do not reveal any deficiencies with the structural integrity of the tank. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COSMIC TRANSPARENCY: A TEST WITH THE BARYON ACOUSTIC FEATURE AND TYPE Ia SUPERNOVAE

Conservation of the phase-space density of photons plus Lorentz invariance requires that the cosmological luminosity distance be larger than the angular diameter distance by a factor of (1 + z){sup 2}, where z is the redshift. Because this is a fundamental symmetry, this prediction-known sometimes as the 'Etherington relation' or the 'Tolman test'-is independent of the world model, or even the assumptions of homogeneity and isotropy. It depends, however, on Lorentz invariance and transparency. Transparency can be affected by intergalactic dust or interactions between photons and the dark sector. Baryon acoustic feature (BAF) and type Ia supernovae (SNeIa) measures of the expansion history are differently sensitive to the angular diameter and luminosity distances and can therefore be used in conjunction to limit cosmic transparency. At the present day, the comparison only limits the change {delta}{tau} in the optical depth from redshift 0.20 to 0.35 at visible wavelengths to {delta}{tau} < 0.13 at 95% confidence. In a model with a constant comoving number density n of scatterers of constant proper cross section {sigma}, this limit implies n{sigma} < 2 x 10{sup -4} h Mpc{sup -1}. These limits depend weakly on the cosmological world model. Assuming a concordance world model, the best-fit value of {delta}{tau} to current data is negative at the 2{sigma} level. This could signal interesting new physics or could be the result of unidentified systematics in the BAF/SNeIa measurements. Within the next few years, the limits on transparency could extend to redshifts z {approx} 2.5 and improve to n{sigma} < 1.1 x 10{sup -5} h Mpc{sup -1}. Cosmic variance will eventually limit the sensitivity of any test using the BAF at the n{sigma} {approx} 4 x 10{sup -7} h Mpc{sup -1} level. Comparison with other measures of the transparency is provided; no other measure in the visible is as free of astrophysical assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

Field testing of modular borehole monitoring with simultaneous distributed acoustic sensing and geophone vertical seismic profiles at Citronelle, Alabama: Field testing of MBM

A modular borehole monitoring concept has been implemented to provide a suite of well-based monitoring tools that can be deployed cost effectively in a flexible and robust package. The initial modular borehole monitoring system was deployed as part of a CO 2 injection test operated by the Southeast Regional Carbon Sequestration Partnership near Citronelle, Alabama. The Citronelle modular monitoring system transmits electrical power and signals, fibre-optic light pulses, and fluids between the surface and a reservoir. Additionally, a separate multi-conductor tubing-encapsulated line was used for borehole geophones, including a specialized clamp for casing clamping with tubing deployment. The deployment of geophones and fibre-optic cables allowed comparison testing of distributed acoustic sensing. We designed a large source effort (>64 sweeps per source point) to test fibre-optic vertical seismic profile and acquired data in 2013. The native measurement in the specific distributed acoustic sensing unit used (an iDAS from Silixa Ltd) is described as a localized strain rate. Following a processing flow of adaptive noise reduction and rebalancing the signal to dimensionless strain, improvement from repeated stacking of the source was observed. Conversion of the rebalanced strain signal to equivalent velocity units, via a scaling by local apparent velocity, allows quantitative comparison of distributed acoustic sensing and geophone data in units of velocity. We see a very good match of uncorrelated time series in both amplitude and phase, demonstrating that velocity-converted distributed acoustic sensing data can be analyzed equivalent to vertical geophones. We show that distributed acoustic sensing data, when averaged over an interval comparable to typical geophone spacing, can obtain signal-to-noise ratios of 18 dB to 24 dB below clamped geophones, a result that is variable with noise spectral amplitude because the noise characteristics are not identical. With vertical seismic profile processing, we demonstrate the effectiveness of downgoing deconvolution from the large spatial sampling of distributed acoustic sensing data, along with improved upgoing reflection quality. finally, we conclude that the extra source effort currently needed for tubing-deployed distributed acoustic sensing vertical seismic profile, as part of a modular monitoring system, is well compensated by the extra spatial sampling and lower deployment cost as compared with conventional borehole geophones.

58 GEOSCIENCES↗

Testing the neutrality of matter by acoustic means in a spherical resonator

Measurements to test the neutrality of matter by acoustic means are reported. The apparatus is based on a spherical capacitor filled with gaseous SF{sub 6} excited by an oscillating electric field. The apparatus has been calibrated measuring the electric polarizability. Assuming charge conservation in the {beta} decay of the neutron, the experiment gives a limit of {epsilon}{sub p-e} < or approx. 1x10{sup -21} for the electron-proton charge difference, the same limit holding for the charge of the neutron. Previous measurements are critically reviewed and found to be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal modulation of nonlinear ultrasonic wave for concrete damage evaluation

A nonlinear ultrasonic test is proposed for material damage evaluation using thermal modulation. Temperature change excites and modulates nonlinear behavior of ultrasonic waves in concrete. Coda wave interferometry was used to analyze the relative velocity change of ultrasonic wave with temperature variations. On concrete samples with different levels of thermal damage, experimental results indicate that the samples with a higher damage level demonstrated higher sensitivity to temperature variations. In addition, a slow dynamics nonlinear behavior was observed. When the temperature changed and then remained constant, the wave velocity gradually approached to its equilibrium value.

Acoustic spectroscopy↗

Langasite Surface Acoustic Wave Sensors: Fabrication and Testing

We report on the development of harsh-environment surface acoustic wave sensors for wired and wireless operation. Surface acoustic wave devices with an interdigitated transducer emitter and multiple reflectors were fabricated on langasite substrates. Both wired and wireless temperature sensing was demonstrated using radar-mode (pulse) detection. Temperature resolution of better than ±0.5°C was achieved between 200°C and 600°C. Oxygen sensing was achieved by depositing a layer of ZnO on the propagation path. Although the ZnO layer caused additional attenuation of the surface wave, oxygen sensing was accomplished at temperatures up to 700°C. The results indicate that langasite SAW devices are a potential solution for harsh-environment gas and temperature sensing.

47 OTHER INSTRUMENTATION↗

Distributed Acoustic Sensing (DAS) Data for Periodic Hydraulic Tests

California State University Long Beach evaluated hydraulic connectivity among geothermal wells using Periodic Hydraulic Testing (PHT) and Distributed Acoustic Sensing (DAS). The principal was to create a pressure signal in one well and observe the responding pressure signals in one or more observation wells to assess the permeability and storage of the fracture network that connects the two wells. DAS measured strain at mHz frequency in monitoring wells in response to PHT.

15 GEOTHERMAL ENERGY↗

DEVELOPMENT OF ASME SECTION X CODE RULES FOR HIGH PRESSURE COMPOSITE HYDROGEN PRESSURE VESSELS WITH NON-LOAD SHARING LINERS

The Boiler and Pressure Vessel Project Team on Hydrogen Tanks was formed in 2004 to develop Code rules to address the various needs that had been identified for the design and construction of up to 15000 psi hydrogen storage vessel. One of these needs was the development of Code rules for high pressure composite vessels with non-load sharing liners for stationary applications. In 2009, ASME approved new Appendix 8, for Section X Code which contains the rules for these vessels. These vessels are designated as Class III vessels with design pressure ranging from 20.7 MPa (3,000 ps)i to 103.4 MPa (15,000 psi) and maximum allowable outside liner diameter of 2.54 m (100 inches). The maximum design life of these vessels is limited to 20 years. Design, fabrication, and examination requirements have been specified, included Acoustic Emission testing at time of manufacture. The Code rules include the design qualification testing of prototype vessels. Qualification includes proof, expansion, burst, cyclic fatigue, creep, flaw, permeability, torque, penetration, and environmental testing.

08 HYDROGEN↗

DAISY Variant and Tether Tests, Admirality Inlet, WA

Acoustic data and metadata from Drifting Acoustic Instrumentation SYstem (DAISY) testing in Admiralty Inlet (connecting Puget Sound to the Strait of San Juan de Fuca) in July 2022. Tests focused on occurrences of flow noise for three hydrophone package variants and on the potential for alternative tether materials.

16 TIDAL AND WAVE POWER↗

Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m{sup -2}.K{sup -1} and 130 μC.N{sup -1} for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in order to investigate their reliability towards neutron fluence. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Concrete Core Testing Report for the Single-Shell Tank 241-A-106 Sidewall Coring Project.

This report provides the results from inspection, physical testing, and petrographic examination of the concrete core removed from the sidewall of Single Shell Tank (SST) 24 l-A-106. The results of physical testing provide engineering mechanics properties that are compared to those used to perform the structural Analysis of Record (AOR) for the type of tanks in A-Farm. Additional results are provided from the nondestructive testing and evaluation (NDE) of the exposed tank dome and sidewall performed using acoustic wave test methods prior to coring. This report implements SST Integrity Project Expert Panel Recommendation SI-3, "Obtain and Test Sidewall Core."

36 MATERIALS SCIENCE↗

Acoustic emission monitoring for assessment of steel bridge details

Acoustic emission (AE) testing was deployed on details of two large steel Interstate Highway bridges: one cantilever through-truss and one trapezoidal box girder bridge. Quantitative measurements of activity levels at known and suspected crack locations were made by monitoring AE under normal service loads (e.g., live traffic and wind). AE indications were used to direct application of radiography, resulting in identification of a previously unknown flaw, and to inform selection of a retrofit detail.

42 ENGINEERING↗

Microcracking Study of Carbon Fiber Composite Materials for Starshade Petals

We have conducted materials tests of representative carbon composite materials for starshade petals. The principal goal of these tests is to assess whether the level of microcracking of the materials as the petals are stowed or deployed (or even as they are handled during assembly) is likely to cause a problem with meeting the tight dimensional tolerances required for starlight suppression. Cracking can cause unexpected deformation, and the cracks can act as reservoirs for gases. It may also lead to roughening of the optical edge whose sharpness minimizes undesirable scattering of light. We use mechanical tests, microscopy, acoustic tomography and small‐angle x‐ray scattering to characterize the microcracking. These tests have found no large cracks (>100 microns) at bending strains up to 0.005, the strain at which audible popping occurred. The stress‐strain curves did not display any anomalies until a precipitous drop in stress at a strain of ~0.012 due to the formation of a transverse crack. Analysis of SAXS data is on‐going which will quantify microcrack distributions at the sub‐micron level. We find no large cracks (>100 microns) at the design strain tolerance for non‐critical structural elements (0.005); analysis is on‐going to quantify nanoscale cracking at the strains of critical structural elements (0.0005).

36 MATERIALS SCIENCE↗

A calibration procedure for sonic infrared nondestructive evaluation

Sonic infrared is potentially a very attractive nondestructive evaluation technique offering the possibility of rapid testing of complex components. However, at present it is difficult to be sure that sufficient excitation has been applied so that a null (no defect present) result can be trusted. This paper presents a calibration method to improve the reliability of the technique. The method uses a measurement of the vibration of the component during the test, the vibration signal being processed to give a 'heating index' which is a measure of the ability of the vibration field to generate heat at any defects of interest that are present. The calculation of the heating index and the rationale for its formulation are described. The method is then applied on two sets of beamlike specimens with cracks of different sizes. The maximum temperature rise in successive tests on a given specimen is shown to correlate well with the maximum heating index, so validating the method. The threshold heating index required to reliably detect cracks as a function of crack size is discussed and practical calibration and test procedures are proposed.

42 ENGINEERING↗

Testing the Technique for the Cluster Analysis of Acoustic Emission Pulse Arrays under the Formation of a Conical Glass Granulate Pile

The technique for the cluster analysis and the classification of registered acoustic emission (AE) data arrays was used for the determination of the isolated phases upon the transition from the regular to the avalanche process of damage accumulation in a physical simulation model. The damage accumulation phases were modeled in the process of formation of a conical glass granulate pile. Their registration was performed by an AE control system synchronized with a high-speed video camera.

36 MATERIALS SCIENCE↗