Search NASASearch

SEARCH · Search NASA

Results for “ADHESION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Improved Mechanical Adhesion Enabled by Bilayer Hole Transport Layers in Perovskite Solar Cells

We investigate buried-interface mechanical integrity in metal-halide perovskite half-cells using carbazole-based self-assembled monolayers (SAMs) and bilayer hole transport layers composed of metal oxide underlayers and SAMs. Combining macroscopic and microscopic characterization, we quantify interfacial fracture energy (Gc) and identify delamination pathways. SAM deposition on NiOx increases Gc by approximately 10-fold compared with ITO, highlighting the importance of oxide underlayer selection. To isolate the effect of removing noncovalently bonded SAM molecules, we use vapor-deposited perovskite as a solvent-free model system, decoupling the rinse step inherent to solution processing. Removing loosely bound SAM molecules increases Gc from 0.94 +- 0.08 J.m-2 to 4.82 +- 0.79 J.m-2. These results show that oxide selection and SAM binding quality are both critical for strengthening buried interfaces and designing mechanically robust perovskite solar cells.

14 SOLAR ENERGY

Catalytic Borylation of Poly(vinyl chloride) Produces Adhesive Materials

Postpolymerization functionalization of polymers can create new applications for existing materials, while retaining their most favorable, intrinsic properties. Polyvinyl chloride (PVC) is a widely used, commodity polymer that is particularly challenging to modify. We report a copper-catalyzed protocol that replaces a small fraction of the C-Cl bonds in PVC with C-B bonds to boronic esters. The reaction occurs with an inexpensive catalyst comprising copper(II) chloride and an NHC ligand derived from a common ionic liquid that is distinct from the N-heterocyclic carbene (NHC) used for the borylation of small alkyl halides. The resulting materials adhere strongly to common surfaces, such as glass and metals, even more strongly than do commercial glues.

D’Angelo, Kyan A

Biofouling and Corrosion Study for a Novel Linear Guided Wave Energy Converter (Post Access Report)

The overall objective of this project was to examine the reliability and performance of antibiofouling coatings used for a wave energy converter (WEC) developed by E-Wave Technologies. The particular coatings were selected for their low toxicity and potential compatibility with aquaculture. The aim of this work was to 1) test coating solutions to prevent biofouling growth and saltwater corrosion on the static (paddle and attachment frame surface) components of the WEC that are submerged, 2) determine adhesion of the coatings to system components, and 3) assess the ease and effectiveness of biofouling cleaning to insure long term performance of the system. An analysis of commercial coatings was performed using methods to examine the prevention of biofouling and coating adhesion properties on two key materials of the WEC, which were 316L low carbon marine grade stainless steel (SS) and Ultra High Molecular Weight Polyethylene (PE). Three marine antifouling paints were selected based on their unique properties to test how different paint styles perform on different materials. The selected paints were ePaint Ecominder self-polishing paint with Zinc Omadine for slime control, Pettit ECO HRT Copper-Free ablative antifouling with Econea biocide, and Intersleek 1100SR foul release. Pacific Northwest National Laboratory (PNNL) prepared PE and SS substrates coated with the three paints and compared the performance against uncoated substrates when submerged in raw seawater for 3-, 6-, and 9-month (m) time periods. Results in adhesion testing indicated that Pettit and ePaint materials clearly bonded strongly to SS, but did not bond comparably well to PE. It was noted during adhesion testing that the Intersleek surfaces were especially difficult to test as the paint highly resists bonding to the epoxy adhesives used with the adherence testing platform. The wear rate of the coatings was not measured under this study; however, based on adhesion testing, coatings in the sliding regions of the Ewave device are expected to wear rapidly. Sandia National Laboratories (SNL) evaluated the adhesion of three different paints to PE and SS substrates which were exposed to a marine environment for time intervals of 0, 3, 6, and 9 months. From qualitative visual analysis of the 3 in2 coupons when pulled from the tank, the 3 in2 coupons generally only appeared to have biofouling consisting of filamentous algae or diatoms, which all have relatively low mass and can be easily wiped from the surface of coupons. Qualitative visual analysis indicated that ECO HRT and Unpainted were consistently worse than Intersleek and Ecominder at all time points. Results provide insight to aid with down-selection of commercial coatings under static conditions to support reliability of the WEC and potential maintenance schedules. This investigation was conducted using small coupon samples suspended in seawater and the development of testing rigs for dynamic component level testing is needed for future work. In addition, the potential toxicity of these commercial coatings on aquaculture has not been determined by this study. One recommendation is to conduct toxicity investigations at the Environmental Toxicity Laboratory at Oak Ridge National Laboratory.

16 TIDAL AND WAVE POWER

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond.

36 MATERIALS SCIENCE

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts.

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Investigation of Debonding Effect in Internal Replacement Pipe System Under Lateral Loading

The aging pipeline infrastructure around the world necessitates immediate rehabilitation. Internal replacement pipe (IRP) is a trenchless system offering a versatile and cost-effective solution across a variety of industries, including oil, natural gas, water, and wastewater. As a structural pipeline repair system, IRPs are subject to lateral deformation because of surface traffic loading. The present study evaluates the impact of adhesion between the host pipe and the IRP, with a focus on assessing the debonding effect on the behavior of the repair system under lateral deformation and bending. This was achieved using a comprehensive approach, including experimental, numerical, and analytical techniques. Varying levels of adhesive strength resulting from different methods of surface preparation were considered. The effectiveness of the IRP system on both discontinuous host pipes with various crack widths and continuous host pipes was also investigated. The results demonstrate that adhesive strength exerts a significant influence on the repair system, especially in the case of narrow circumferential cracks, while its impact on the continuous system is minimal. For optimal performance, it is essential to choose adhesives that possess sufficient shear strength while also accounting for the required debonding length. This approach ensures that minor discontinuities are effectively controlled, thereby enhancing the system′s fatigue life. The reliable determination of the maximum allowable shear strength for the adhesive or the debonding length can ensure that it does not negatively affect fatigue life. The findings presented in this study offer new insights into the development of trenchless repair techniques that can enhance system performance and extend service life.

Tien, Tri C. M.