Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Comparison under a simulated sun of two black-nickel-coated flat-plate solar collectors with a nonselective black-paint-coated collector

A performance evaluation was made of two, black nickel coated, flat plate solar collectors. Collector performance was determined under a simulated sun for a wide range of inlet temperatures, including the temperature required for solar powered absorption air conditioning. For a basis of comparison a performance test was made on a traditional, two glass, nonselective, black paint coated, flat plate collector. Performance curves and performance parameters are presented to point out the importance of the design variables which determine an efficient collector. A black nickel coated collector was found to be a good performer at the conditions expected for solar powered absorption air conditioning. This collector attained a thermal efficiency of 50 percent at an inlet temperature of 366 K (200 F) and an incident flux of 946 watts/sq m (300 Btu/hr-sq ft).

Simon, F. F.↗

Instrumentation, control and data management for the MIST (Modular Integrated Utility System) Facility

An appendix providing the technical data required for computerized control and/or monitoring of selected MIST subsystems is presented. Specific computerized functions to be performed are as follows: (1) Control of the MIST heating load simulator and monitoring of the diesel engine generators' cooling system; (2) Control of the MIST heating load simulator and MIST heating subsystem including the heating load simulator; and (3) Control of the MIST air conditioning load simulator subsystem and the MIST air conditioning subsystem, including cold thermal storage and condenser water flows.

Celino, V. A.↗

Heat pipes for terrestrial applications in dehumidification systems

A novel application of heat pipes which greatly enhances dehumidification performance of air-conditioning systems is presented. When an air-to-air heat pipe heat exchanger is placed between the warm return air and cold supply air streams of an air conditioner, heat is efficiently transferred from the return air to the supply air. As the warm return air precools during this process, it moves closer to its dew-point temperature. Therefore, the cooling system works less to remove moisture. This paper discusses the concept, its benefits, the challenges of incorporating heat pipes in an air-conditioning system, and the preliminary results from a field demonstration of an industrial application.

Khattar, Mukesh K.↗

1D modeling of plasma streamers at ammonia-air flame conditions

Abstract Self-consistent 1D modeling of streamers in ammonia-oxygen-nitrogen-water mixtures has been performed in this work. A fluid model that includes species transport, electrostatic potential, and detailed chemistry was developed and verified. This model is then used to simulate the avalanche, streamer formation and propagation phases, driven by a nanosecond voltage pulse, at different thermochemical conditions derived from a 1D laminar premixed ammonia-air flame. The applicability of the Meek’s criterion in predicting the streamer inception location was successfully confirmed. Streamer formation and propagation duration were found to vary significantly with different thermochemical conditions, due to the difference in ionization rates. The thermochemical state also affected the breakdown characteristics which was tested by maintaining the background reduced electric field constant. Detailed kinetic analyses revealed the importance of O ( 1 D ) in the production of key radicals, such as O, OH, and NH 2 . Furthermore, the contributions of the dissociative electronic excitation of NH 3 towards the production of H and NH 2 radicals have also been reported. Spatial and temporal evolution of the electron energy loss fractions for various inelastic collision processes at different thermochemical states uncovered the input plasma energy spent of fuel dissociation and the large variability in the dominant processes during the avalanche and streamer propagation phases. The methodology and analyses reported in this work are key towards developing effective strategies for controlled nanosecond-pulsed non-equilibrium plasma sources used for ammonia ignition and flame stabilization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of a fuel cell on-site integrated energy system for a residential complex

The energy use and costs of the on-site integrated energy system (OS/IES) which provides electric power from an on-site power plant and recovers heat that would normally be rejected to the environment is compared to a conventional system purchasing electricity from a utility and a phosphoric acid fuel cell powered system. The analysis showed that for a 500-unit apartment complex a fuel OS/IES would be about 10% more energy conservative in terms of total coal consumption than a diesel OS/IES system or a conventional system. The fuel cell OS/IES capital costs could be 30 to 55% greater than the diesel OS/IES capital costs for the same life cycle costs. The life cycle cost of a fuel cell OS/IES would be lower than that for a conventional system as long as the cost of electricity is greater than $0.05 to $0.065/kWh. An analysis of several parametric combinations of fuel cell power plant and state-of-art energy recovery systems and annual fuel requirement calculations for four locations were made. It was shown that OS/IES component choices are a major factor in fuel consumption, with the least efficient system using 25% more fuel than the most efficient. Central air conditioning and heat pumps result in minimum fuel consumption while individual air conditioning units increase it, and in general the fuel cell of highest electrical efficiency has the lowest fuel consumption.

Simons, S. N.↗

Un-Alerted Smoke and Fire: Checklist Content and Intended Crew Response

An in-flight smoke or fire event is an emergency unlike almost any other. The early cues for un-alerted conditions, such as air conditioning smoke or fire, are often ambiguous and elusive. The checklists crews use for these conditions must help them respond quickly and effectively and must guide their decisions. Ten years ago an industry committee developed a template to guide the content of Part 121 checklists for un-alerted smoke and fire events. This template is based upon a new philosophy about how crews should use the checklists and respond to the events. To determine the degree to which current un-alerted checklists of in-flight smoke or fire comply or are consistent with the guidance outlined in the template, I collected and analysed checklists from North American air carriers.

smoke and fire↗

Comparison of chemical lateral boundary conditions for air quality predictions over the contiguous United States during pollutant intrusion events

The National Air Quality Forecast Capability (NAQFC) operated in U.S.’s National Oceanic and Atmospheric Administration (NOAA) provides the operational forecast guidance for ozone and fine particulate matters with aerodynamic diameters less than 2.5μm (PM2.5) over the contiguous 48 U.S. states (CONUS) using the Community Multi-scale Air Quality (CMAQ) model. The existing NAQFC uses climatological chemical lateral boundary conditions ( CLBCs), which cannot capture pollutant intrusion events originating outside of the model domain. In this study, we developed a model framework to use dynamic CLBCs from the Goddard Earth Observing System Model, version 5 (GEOS) to drive NAQFC. A mapping of the GEOS chemical species to the CMAQ’s Carbon Bond 5 (CB05)-Aero6 species was developed. The utilization of the GEOS dynamic CLBCs in NAQFC showed the best overall performance in simulating the surface observations during the Saharan dust intrusion and Canadian wildfire events in summer 2015.The simulated PM2.5 was improved from 0.18 to 0.37 and the mean bias was reduced from -6.74 μg/m3 to -2.96 μg/m3 over CONUS. Although the effect of CLBCs on the PM2.5 correlation was mainly near the inflow boundary, its impact on the background concentrations reached further inside the domain. The CLBCs could affect background ozone concentrations through the inflows of ozone itself and its precursors, such as CO. It was further found that the aerosol optical thickness (AOT) from satellite retrievals correlated well with the column CO and elemental carbon from GEOS. The satellite-derived AOT CLBCs generally improved the model performance for the wildfire intrusion events during a summer 2018 case study, and demonstrated how satellite observations of atmospheric composition could be used as an alternative method to capture the air quality effects of intrusions when the global model CLBCs, such as GEOS CLBCs, are not available.

Community Multi-scale Air Quality (CMAQ) model↗

2D Modeling of Plasma Streamer and Glow Phases at Ammonia-Air Flame Conditions

Streamer and glow plasma phases have been modeled at two thermochemical states of an ammonia-air flame: fresh reactants and burnt products. A new AMReX-based solver has been verified against benchmarks in the literature and has been used to perform these simulations. A Helmholtz-equation based photoionization model with parameters accounting for the presence of NH3 in air has been coupled with the solver to accurately model the streamer propagation phase. A detailed plasma kinetics mechanism has been compiled and used to predict the evolution of electrons, excited states, ions, and radicals during streamer propagation and glow formation. The propagation velocity of streamers was found increase by almost two-fold when the mixture was changed from the fresh reactants to the burnt products. Moreover, vibrational excitation was found to be limited to the streamer body, whereas ionization predominantly occurred at the streamer head, as is expected. Finally, the differences in the pathways of O and H radical production during the streamer propagation and glow phases have been briefly discussed.

ammonia-air flame↗

Pilot retrofit test of refrigerant R-134a for GDSCC

NASA has issued an interim policy requiring all of its Centers to eliminate consumption (purchase) of stratospheric ozone-depleting substances, including chlorofluorocarbons (CFC's), by 1995. Also, plans must be outlined for the eventual phase out of their usage. The greatest source of CFC consumption and usage at the Goldstone Deep Space Communications Complex is refrigerant R-12, which is used in many of the facility's air-conditioning systems. A pilot retrofit test shows that retrofitting R-12 air-conditioning systems with hydrofluorocarbon R-13a would be a workable means to comply with the R-12 portion of NASA's policy. Results indicate acceptable cost levels and nearly equivalent system performance.

Albus, J.↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Heat pipes for low-humidity applications

A novel application of an air-to-air heat pipe heat exchanger (HPHX) in a cooling and dehumidification process of an air-conditioning system is described which provides significant energy savings in applications requiring reheat of cold supply air to maintain low humidity. The efficiency of the system has been demonstrated in an application requiring a humidity of 40 percent. The use of the HPHX and fine tuning of the air-conditioning system and controls has resulted in significant energy savings. The technology can be advantageously used in many low-humidity applications commonly encountered in high-tech and aerospace facilities.

Khattar, Mukesh K.↗

Fault Diagnosis in HVAC Chillers

Modern buildings are being equipped with increasingly sophisticated power and control systems with substantial capabilities for monitoring and controlling the amenities. Operational problems associated with heating, ventilation, and air-conditioning (HVAC) systems plague many commercial buildings, often the result of degraded equipment, failed sensors, improper installation, poor maintenance, and improperly implemented controls. Most existing HVAC fault-diagnostic schemes are based on analytical models and knowledge bases. These schemes are adequate for generic systems. However, real-world systems significantly differ from the generic ones and necessitate modifications of the models and/or customization of the standard knowledge bases, which can be labor intensive. Data-driven techniques for fault detection and isolation (FDI) have a close relationship with pattern recognition, wherein one seeks to categorize the input-output data into normal or faulty classes. Owing to the simplicity and adaptability, customization of a data-driven FDI approach does not require in-depth knowledge of the HVAC system. It enables the building system operators to improve energy efficiency and maintain the desired comfort level at a reduced cost. In this article, we consider a data-driven approach for FDI of chillers in HVAC systems. To diagnose the faults of interest in the chiller, we employ multiway dynamic principal component analysis (MPCA), multiway partial least squares (MPLS), and support vector machines (SVMs). The simulation of a chiller under various fault conditions is conducted using a standard chiller simulator from the American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE). We validated our FDI scheme using experimental data obtained from different types of chiller faults.

Choi, Kihoon↗

EPCAPE-PT-LANL Measurements: Humidified Cavity Attenuated Phase Shift Spectroscopy

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Humidified Cavity Attenuated Phase Shift Particulate Matter Single Scattering Albedo (H-CAPS-PMSSA, Aerodyne Inc) Data Notes: The scattering truncation correction was not applied to Bsca. The Bext needs no correction. Files: data_10sec_CAPS.csv, data_10min_CAPS.csv Header: - Bext_wet_CAPS_450nm[1/Mm]: Wet aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_wet_CAPS_450nm[1/Mm]: Wet aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_wet_CAPS[K]: Temperature inside the wet CAPS measurement chamber, in Kelvin. - Bext_dry_CAPS_450nm[1/Mm]: Dry aerosol extinction coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Bsca_dry_CAPS_450nm[1/Mm]: Dry aerosol scattering coefficient measured at 450 nm by the CAPS, in inverse megameters (Mm⁻¹). - Temp_dry_CAPS[K]: Temperature inside the dry CAPS measurement chamber, in Kelvin. - Wet_RH_preCAPS[%]: Relative humidity before entering the wet CAPS, in percent. - Wet_RH_postCAPS[%]: Relative humidity after exiting the wet CAPS, in percent. - Humidifier_RH_CAPS[%]: Relative humidity inside the humidifier used with the CAPS, in percent. - dualCAPS_inlet_RH[%]: Relative humidity at the inlet of the dual (wet/dry) CAPS setup, in percent. - Wet_Temp_preCAPS[C]: Temperature before entering the wet CAPS, in degrees Celsius. - Wet_Temp_postCAPS[C]: Temperature after exiting the wet CAPS, in degrees Celsius. - Humidifier_Temp[C]: Temperature inside the humidifier used with the CAPS, in degrees Celsius. - dualCAPS_inlet_Temp[C]: Temperature at the inlet of the dual (wet/dry) CAPS setup, in degrees Celsius. - Zero_dry_CAPS: 1 is a calibration check for the dry CAPS to ensure zero reading under filter air conditions. - Zero_wet_CAPS: 1 is a calibration check for the wet CAPS to ensure zero reading under filter air conditions. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Performance Boosting Additive

Mainstream Engineering Corporation was awarded Phase I and Phase II contracts from Goddard Space Flight Center's Small Business Innovation Research (SBIR) program in early 1990. With support from the SBIR program, Mainstream Engineering Corporation has developed a unique low cost additive, QwikBoost (TM), that increases the performance of air conditioners, heat pumps, refrigerators, and freezers. Because of the energy and environmental benefits of QwikBoost, Mainstream received the Tibbetts Award at a White House Ceremony on October 16, 1997. QwikBoost was introduced at the 1998 International Air Conditioning, Heating, and Refrigeration Exposition. QwikBoost is packaged in a handy 3-ounce can (pressurized with R-134a) and will be available for automotive air conditioning systems in summer 1998.

Source record↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

Unlocking the Path to Decarbonized Building Thermal Systems: Strategies for Designers and Contractors: Preprint

The design and construction community plays a pivotal role in facilitating the transition to decarbonized thermal systems that maintain human comfort while reducing building emissions. Through the U.S. Department of Energy Better Buildings initiative's Design and Construction Allies, a cohort of leading architecture, engineering, and construction firms have identified top ranked barriers that designers and contractors face when implementing solutions for building owners. These barriers to decarbonizing thermal - especially heating - systems include equipment availability; electrical capacity constraints; space allocations; complex system configurations; and lack of experience in designing, installing, and maintaining heat pumps. These impediments significantly amplify the risk and financial burden associated with the adoption of decarbonized solutions. The barriers also decrease the likelihood that designers, contractors, and owners will adopt decarbonization strategies without clear plans and guidance on how to implement these solutions, mitigate risk, and overcome the identified barriers. The National Renewable Energy Laboratory, the Design and Construction Allies, and the American Society of Heating, Refrigerating, and Air-Conditioning Engineers have developed "how to" thermal decarbonization guidance based on best practices. The subjects covered range from the role of energy efficiency in facilitating decarbonized heating solutions to strategies for decarbonizing new and existing heating, ventilating, and air-conditioning systems. The focus is on overcoming barriers so that energy-efficient, electrified buildings - both new and retrofit - become the industry standard. This paper outlines 1) the method used to collect and organize this guidance, 2) industry barriers to decarbonization, and 3) decarbonization techniques that have broad market applicability.

building heating↗