Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - COMPRESSIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Heat-transfer coefficients for air flowing in round tubes, in rectangular ducts, and around finned cylinders

Report reviews published data and presents some new data on heat transfer to air flowing in round tubes, in rectangular ducts, and around finned cylinders. The available data for heat transfer to air in straight ducts of rectangular and circular cross section have been correlated in plots of Stanton number versus Reynolds number to provide a background for the study of the data for finned cylinders. Equations are recommended for both the streamlined and turbulent regions, and data are presented for the transition region between turbulent and laminar flow. Use of hexagonal ends on round tubes causes the characteristics of laminar flow to extend to high Reynolds numbers. Average coefficients for the entire finned cylinder have been calculated from the average temperature at the base of the fins and an equation which was derived to allow for the effectiveness of the fins. The available results for each finned cylinder are correlated herein in terms of graphs of Stanton number versus Reynolds number. In general, for a given Reynolds number, the Stanton number increases with increases in both spacing and width of the fins, and is apparently independent of cylinder diameter and temperature difference. For a given coefficient of heat transfer improved baffles and rough or wavy surfaces give a substantial reduction in pumping power per unit of heat transfer surface and a somewhat smaller decrease in pressure drop. (author)

Drexel, Rober E↗

Pyrolysis of polymeric materials. I - Effect of chemical structure, temperature, heating rate, and air flow on char yield and toxicity

Various polymeric materials, including synthetic polymers and cellulosic materials, were evaluated at different temperatures, heating rates and air flow rates for thermophysical and toxicological responses. It is shown that char yields appeared to be a function of air access as much as of the chemical structure of the material. It is stated that the sensitivity of the apparent thermal stability of some materials to air access is so marked that thermogravimetric studies in oxygen-free atmospheres may be a consistently misleading approach to comparing synthetic polymers intended to increase fire safety. Toxicity also appeared to be a function of temperature and air access as much as of the chemical structure of the material. Toxicity of the gases evolved seemed to increase with increasing char yield for some polymers.

Hilado, C. J.↗

Methods of Visually Determining the Air Flow Around Airplanes

This report describes methods used by the National Advisory Committee for Aeronautics to study visually the air flow around airplanes. The use of streamers, oil and exhaust gas streaks, lampblack and kerosene, powdered materials, and kerosene smoke is briefly described. The generation and distribution of smoke from candles and from titanium tetrachloride are described in greater detail because they appear most advantageous for general application. Examples are included showing results of the various methods.

Gough, Melvin N↗

An Experimental Investigation of Several Low-Drag Wing-Nacelle Combinations with Internal Air Flow

The results of an experimental investigation of several low-drag wing-nacelle combinations, incorporating internal air-flow systems, are presented. The external-drag increments due to these nacelles are between one-half and two-thirds of those of conventional nacelle forms. This improvement is accomplished with only minor effects on the lift and moment characteristics of the wing. The procedure employed to determine the external shape of such low-drag nacelles is considered in detail. The design of an efficient internal-flow system with or without a blower or throttle, presents no serious problems. The energy losses in the expansion before the engine and the contraction thereafter can be kept small. It is believed that these nacelles have a wide application in housing engine pusher-propeller units and, with some alteration, jet-propulsion devices. It is probable that the low external drags may not be realized if such nacelles are used with a tractor propeller because of the high level of turbulence in the propeller slipstream.

Allen, H. Julian↗

An Air-flow-direction Pickup Suitable for Telemetering Use on Pilotless Aircraft

A free-swiveling vane-type pickup for measuring air flow direction in both the angle-of-attack and angle-of-sideslip directions is described. The device, which is intended to telemeter flow direction from pilotless aircraft, has variable-inductance outputs suitable for use in the 100 to 200 kcps subcarrier frequency range of the NACA FM-AM telemetering system. Preliminary test results indicate that it can also be adapted for use with the audio subcarrier frequencies of the Research and Development Board standard FM-FM telemetering system. Test results are presented which indicate that the pickup is aerodynamically stable and has an accuracy, obtained from a bench calibration, of better than 0.3 degrees under conditions including acceleration up to 20g in any direction, Mach numbers from 0.5 to 2.8, and dynamic pressures up to at least 65 psi. Equations and curves which can be used to obtain flow direction at the center of gravity of a maneuvering model are presented.

Ikard, Wallace L↗

Heat transfer from high-temperature surfaces to fluids II : correlation of heat-transfer and friction data for air flowing in inconel tube with rounded entrance

A heat transfer investigation, which was an extension of a previously reported NACA investigation, was conducted with air flowing through an electrically heated inconel tube with a rounded entrance,an inside diameter of 0.402 inch, and a length of 24 inches over a range of conditions, which included Reynolds numbers up to 500,000, average surface temperatures up to 2050 degrees R, and heat-flux densities up to 150,000 Btu per hour per square foot. Conventional methods of correlating heat-transfer data wherein properties of the air were evaluated at the average bulk, film, and surface temperatures resulted in reductions of Nusselt number of about 38, 46, and 53 percent, respectively, for an increase in surface temperature from 605 degrees to 2050 degrees R at constant Reynolds number. A modified correlation method in which the properties of air were based on the surface temperature and the Reynolds number was modified by substituting the product of the density at the inside tube wall and the bulk velocity for the conventional mass flow per unit cross-sectional area, resulted in a satisfactory correlation of the data for the extended ranges of conditions investigated.

Lowdermilk, Warren H↗

Experimental Investigation of Average Heat-Transfer and Friction Coefficients for Air Flowing in Circular Tubes Having Square-Thread-Type Roughness

An investigation of forced-convection heat transfer and associated pressure drops was conducted with air flowing through electrically heated Inconel tubes having various degrees of square-thread-type roughness, an inside diameter of 1/2 inch, and a length of 24 inches. were obtained for tubes having conventional roughness ratios (height of thread/radius of tube) of 0 (smooth tube), 0.016, 0.025, and 0.037 over ranges of bulk Reynolds numbers up to 350,000, average inside-tube-wall temperatures up to 1950deg R, and heat-flux densities up to 115,000 Btu per hour per square foot. Data The experimental data showed that both heat transfer and friction increased with increase in surface roughness, becoming more pronounced with increase in Reynolds number; for a given roughness, both heat transfer and friction were also influenced by the tube wall-to-bulk temperature ratio. Good correlation of the heat-transfer data for all the tubes investigated was obtained by use of a modification of the conventional Nusselt correlation parameters wherein the mass velocity in the Reynolds number was replaced by the product of air density evaluated at the average film temperature and the so-called friction velocity; in addition, the physical properties of air were evaluated at the average film temperature. The isothermal friction data for the rough tubes, when plotted in the conventional manner, resulted in curves similar to those obtained by other investigators; that is, the curve for a given roughness breaks away from the Blasius line (representing turbulent flow in smooth tubes) at some value of Reynolds number, which decreases with increase in surface roughness, and then becomes a horizontal line (friction coefficient independent of Reynolds number). A comparison of the friction data for the rough tubes used herein indicated that the conventional roughness ratio is not an adequate measure of relative roughness for tubes having a square-thread-type element. The present data, as well as those of other investigators, were used to isolate the influence of ratios of thread height to width, thread spacing to width, and the conventional roughness ratio on the friction coefficient. A fair correlation of the friction data was obtained for each tube with heat addition when the friction coefficient and Reynolds number were defined on the basis of film properties; however, the data for each tube retained the curve characteristic of that particular roughness. The friction data for all the rough tubes could be represented by a single line for the complete turbulence region by incorporating a roughness parameter in the film correlation. No correlation was obtained for the region of incomplete turbulence.

Sams, E. W.↗

Theoretical Evaluation of Electroactive Polymer Based Micropump Diaphragm for Air Flow Control

An electroactive polymer (EAP), high energy electron irradiated poly(vinylidene fluoride-trifluoroethylene) [P(VDFTrFE)] copolymer, based actuation micropump diaphragm (PAMPD) have been developed for air flow control. The displacement strokes and profiles as a function of amplifier and frequency of electric field have been characterized. The volume stroke rates (volume rate) as function of electric field, driving frequency have been theoretically evaluated, too. The PAMPD exhibits high volume rate. It is easily tuned with varying of either amplitude or frequency of the applied electric field. In addition, the performance of the diaphragms were modeled and the agreement between the modeling results and experimental data confirms that the response of the diaphragms follow the design parameters. The results demonstrated that the diaphragm can fit some future aerospace applications to replace the traditional complex mechanical systems, increase the control capability and reduce the weight of the future air dynamic control systems. KEYWORDS: Electroactive polymer (EAP), micropump, diaphragm, actuation, displacement, volume rate, pumping speed, clamping ratio.

Xu, Tian-Bing↗

Heat Transfer from High-Temperature Surfaces to Fluids III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperatures up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R.

Sams, Eldon W.↗

Calibration of Air-Flow Meters for J33 Compressor Investigation

Flow-metering devices used by the NACA and by the manufacturer of the J33 turbojet engine were calibrated together to determine whether an observed discrepancy in weight flow of approximately 4 percent for the two separate investigations might be due to the different devices used to meter air flow. A commercial adjustable orifice and a square-edge flat-plate orifice used by the NACA and a flow nozzle used by the manufacturer were calibrated against surveys across the throat of the nozzle. It was determined that over a range of weight flows from 18 to 45 pounds per second the average weight flows measured by the metering device used for the compressor test would be 0.70 percent lower than those measured by the metering device used in the engine tests and the probable variation about this mean would be +/- 0.39 percent. The very close agreement of the metering devices shows that the greater part of the discrepancy in weight flow is attributable to the effect of inlet pressure.

Kovach, Karl↗

Effect of Air-Flow Distribution and Total-Pressure Loss on Performance of One-Sixth Segment of Turbojet Combuster

An investigation has been conducted on a one-sixth segment of an annular turbojet combustor to determine the effects of modification in air-flow distribution and total-pressure loss on the performance of the segment. The performance features investigated during this series of determinations were the altitude operational limits and the temperature-rise efficiency. Altitude operational limits of the combustor segment, for the 19XB engine using the original combustor-basket design were approximately 38,000 feet at 17,000 rpm and 26,000 feet at 10,000 rpm. The altitude operational limits were approximately 50,000 feet at 17,000 rpm and 38,000 feet at 10,000 rpm for a combustor-basket design in which the air-passage area in the basket was redistributed so as to admit gradually no more than 20 percent of the air along the first half of the basket. In this case the total pressure loss through the combustor segment was not appreciably changed from the total-pressure loss for the original combustor basket design. Altitude operational limits of the combustor segment for the 19XB engine were above 52,000 feet at 17,000 rpm and were approximately 23,000 feet at 10,000 rpm for a combustor-basket design in which the distribution of the air-passage area in the basket was that of the original design but where the total-pressure loss was increased to 19 times the inlet reference kinetic pressure at an inlet-to-outlet density ratio of 2.4. The total-pressure loss for the original design was 14 times the inlet kinetic reference pressure at an inlet-to-outlet density ratio of 2.4.

Hill, Francis U.↗

A method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations due to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainty in the temperature and density measurements can be less than 2 and 3 percent, respectively, if the signal uncertainties are dominated by photon-statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Method for measuring temperatures and densities in hypersonic wind tunnel air flows using laser-induced O2 fluorescence

Laser-induced fluorescence in oxygen, in combination with Raman scattering, is shown to be an accurate means by which temperature, density, and their fluctuations owing to turbulence can be measured in air flows associated with high-speed wind tunnels. For temperatures above 60 K and densities above 0.01 amagat, the uncertainties in the temperature and density measurements can be less than 2 percent, if the signal uncertainties are dominated by photon statistical noise. The measurements are unaffected by collisional quenching and can be achieved with laser fluences for which nonlinear effects are insignificant. Temperature measurements using laser-induced fluorescence alone have been demonstrated at known densities in the range of low temperatures and densities which are expected in a hypersonic wind tunnel.

Laufer, Gabriel↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

Pitot tube↗

Defining the Operational Envelope for Air Flows in the Miniature Arc-Jet Research Chamber (mARC II)

The second-generation 30 kW miniature Arc-jet Research Chamber (mARC II) at NASA Ames Research Center produces high enthalpy flows relevant for entry systems ground testing. The mARC II facility has recently undergone upgrades, including the installation of a new vacuum system to address the issues preventing it from maintaining underexpanded flow under test conditions. In this work, we present data obtained from an Integrated Systems Testing campaign and provide an initial assessment of arc-jet performance following the upgrades. Air is used as the working gas for the standard mARC II arc-heater configuration with two constrictor disks. Seven runs were investigated for five test conditions to assess the lowest achievable stagnation point heat fluxes for air flow rates of 0.15 or 0.25 g s −1 . The heat flux was measured using a water-cooled Gardon gauge (Ø4.76 mm, 3/16" hemispherical) at 70 mm from the nozzle exit plane. The new vacuum system produced test box pressures in the medium (fine) vacuum range (~0.03 torr, 4 Pa) prior to gas addition and successfully maintained underexpanded flow after gas addition. The upgrade yielded a ~4X reduction in heat flux relative to the previous system for the same set test conditions. We report the lowest heat fluxes measured in mARC II to date, ranging from 26 to 81 W cm −2 , for sonic flow enthalpies of 4–14 MJ kg −1 . Bulk enthalpies estimated using an energy balance method (EB 2 ) are reported for the first time using mARC II.Initial data suggests EB 2 generally estimates lower enthalpies than sonic flow methods for mARC II. Lastly, laminar axisymmetric Navier–Stokes simulations were performed using the NASA DPLR code. Numerical heat flux results show good agreement with experiments at low arc powers (3–15% difference at the minimum set arc current), but discrepancy increases with arc power (49% difference at the maximum set arc current).

arc-jet↗

Exploratory investigation of the use of area suction to eliminate air-flow separation in diffusers having large expansion angles

Tests were made at a mean inlet Mach number of 0.2 with area suction applied to conical diffusers with expansion angles of 30 degrees and 50 degrees and exit to inlet area ratios of 2. Air-flow separation was eliminated with suction mass flows of 3 and 4 percent of the inlet mass flows for the 30 degrees and 50 degrees diffusers, respectively.

DIFFUSERS, SUBSONIC↗