Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR INFILTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Oxidation performance and limitations of additively manufactured SiC/Si-O-C composites at elevated temperatures

Here, SiC preforms were infiltrated with polycarbosiloxane preceramic polymer to create low-cost SiC—Si x O y C z matrix composites for possible high temperature application. The effect of specimen annealing conditions on the steam and air oxidation resistance was analyzed. Air exposures from 900–1500°C showed stability of the Si x O y C z matrix phase with moderate oxidation resistance. After 900°C exposures, oxidation of the composite is primarily limited to the matrix phase, and only at 1200 and 1500°C was SiC consumption visualized. Steam cycle exposures at 1200°C resulted in rapid linear oxidation of the composites with induced specimen swelling from volume expansion associated with internal oxidation. Specimens annealed in argon were found to be the most oxidation resistant due to increased matrix crystallinity and carbon retention. The results of this work were used to develop clear strategies for improving the high-temperature properties of SiC—Si x O y C z composites.

36 MATERIALS SCIENCE↗

Relating land surface, water table, and weathering fronts with a conceptual valve model for headwater catchments

Knowing little about how porosity and permeability are distributed at depth, we commonly develop models of groundwater by treating the subsurface as a homogeneous black box even though porosity and permeability vary with depth. One reason for this depth variation is that infiltrating meteoric water reacts with minerals to affect porosity in localized zones called reaction fronts. We are beginning to learn to map and model these fronts beneath headwater catchments and show how they are distributed. The subsurface landscapes defined by these fronts lie subparallel to the earth-air interface but with lower relief. They can be situated above, below, or at the water table. These subsurface landscapes of reaction are important because porosity developed from weathering can control subsurface water storage. In addition, porosity often changes at the weathering fronts, and when this affects permeability significantly, the front can act like a valve that re-orients water flowing through the subsurface. We explore controls on the positions of reaction fronts under headwater landscapes by accounting for the timescales of erosion, chemical equilibration, and solute transport. One strong control on the landscape of subsurface reaction is the land surface geometry, which is in turn a function of the erosion rate. In addition, the reaction fronts, like the water table, are strongly affected by the lithology and water infiltration rate. We hypothesize that relationships among the land surface, reaction fronts, and the water table are controlled by feedbacks that can push landscapes toward an “ideal hill”. In this steady state, reaction-front valves partition water volumes into shallow and deep flowpaths. Furthermore, these flows dissolve low- and high-solubility minerals, respectively, allowing their reaction fronts to advance at the erosion rate. This conceptualization could inform better models of subsurface porosity and permeability, replacing the black box.

54 ENVIRONMENTAL SCIENCES↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unraveling the conundrum of electronic leakage in protonic ceramic cells: Operation-specific insights and rational design strategies

Electronic conduction through proton-conducting electrolytes significantly impairs the efficiency of protonic ceramic cells (PCCs). Here, in this study, we explore the electron and ion mixed transport properties of four common protonic ceramics, BaZr 0.8 Y 0.2 O 3-δ (BZY82), BaZr 0.7 Ce 0.2 Y 0.1 O 3-δ (BZCY721), BaZr 04 Ce 0.4 Y 0.1 Yb 0.1 O 3-δ (BZCYYb4411), and BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ (BZCYYb1711). It marks the first instance of investigating these properties under operation-specific scenarios: fuel side of electrolysis cell, air side of electrolysis cell, fuel side of fuel cell, and air side of the fuel cell. BZCYYb1711 exhibits the highest ionic conductivity, but two to three times higher electronic leakage when exposed to oxygen-containing environments than the others. BZY82 exhibits approximately two times higher electronic leakage in a hydrogen-containing environment. BZCY721 demonstrates excellent ion transport numbers (~0.95) across these four operating conditions. BZCYYb4411 behaves quite similarly to BZCY721. The most challenging operating environment for all candidates is the air side of fuel cell mode. This mode leads to a high initial electronic leakage, followed by a significant increase with polarization. The probable cause for this behavior is a H 2 -free, polarization-induced reduction that leads to the formation of V$^•_O$. The electron small polaron associated with V$^•_O$ is released by the electrical field due to the Poole-Frenkel effect. ZnO and NiO sintering aids are found to be detrimental to the ionic conductivity of the electrolytes. In particular, NiO substantially lowers the ion transport number. The correlation of the operation-specific electronic leakage to full cells is discussed. It is suggested that a rational PCC design should synergistically couple BZCYYb1711 at fuel side with BZCY4411 at air side to deliver a well-balanced performance and faradaic efficiency simultaneously, and the high temperature sintering process with a NiO fuel electrode should be shortened or replaced by ultra-fast sintering techniques or using a fuel electrode scaffold-infiltration fabrication strategy.

42 ENGINEERING↗

Data and scripts associated with the manuscript evaluating the hydrologic responses of the Pacific Northwest watersheds to wildfires (v2)

This data package is associated with the publication “Evaluating Post-fire Watershed Response to Varying Burn Severity and Precipitation Regimes Using Fully-distributed and Integrated Hydrologic Models” submitted to Journal of Hydrology (Li et al. 2025). In this study, we employed the Advanced Terrestrial Simulator (ATS), an integrated watershed model that couples surface flow, subsurface flow, and canopy biophysical processes, to investigate post-fire hydrologic responses in a few selected watersheds with varying burn severity.The data package contains the required input data (meteorological forcing, Leaf Area Index, wildfire burn severities, etc.) to run the model, configuration files, the Jupyter notebooks in Python to pre-process and post-process data, the figures in the manuscript, and the modeling output files. The variables include watershed-averaged evapotranspiration, watershed-averaged surface/subsurface/canopy water content, and river discharge at watershed outlet.The data package contains a file-level metadata that lists and describes all the files contained in the data package (ATS_flmd.csv), a data dictionary file that defines columns headers across all csv files contained in the data package (ATS_dd.csv), a data package level readme file (the current file), and four zipped folders.The ‘data’ folder provides data needed to run the model in .h5, .i2s, .xyz, .shp, and .exo formats. The sub-folders are for each data types. The ‘model’ folder provides input files (.xml format) and essential model outputs. Each sub-folder provides the files from each simulated watershed. The ‘notebooks’ folder provides the Jupyter notebooks (.ipynb format) for pre- and post- processing model files, and for producing the figures in the manuscript. The ‘figures’ folder provides the figures associated with manuscript in .pdf and .png formats.The ‘model’ folder and the ‘data’ folder have been split into 5GB-large pieces using the Linux command ‘split -b 5120m model.zip model.zip.’ and ‘split -b 5120m data.zip data.zip.’, respectively. They can be merged back using the Linux command ‘cat model.zip.* > model.zip’ and ‘cat data.zip.* > data.zip’, respectively.

54 ENVIRONMENTAL SCIENCES↗

Intermediate Temperature Proton‐Conducting Solid Oxide Electrolysis Cells with Improved Performance and Durability

Technical understanding: A high-performance and stable intermediate temperature proton-conducting solid oxide electrolysis cell (PCEC) will add significantly to the hydrogen roadmap of EERE. However, the low electrocatalytic activity of the air electrode and the instability of the electrolyte are technical barriers. In this research, we utilized computational fluid dynamic modeling and materials/microstructure engineering to investigate the complex reaction chain and to improve the performance and reliability of the protonic ceramic electrochemical cells. An active and stable Pr 1.8 Ba 0.2 NiO 4+δ -BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ (BZCYYb) scaffold conformal coating electrode was rationally designed where the robust Pr 1.8 Ba 0.2 NiO 4+δ functions both as a catalytic active and a protective layer. The PCECs with porosity-optimized scaffold conformal coating electrodes demonstrate 1.46 Acm -2 under 1.3 V at 600°C, which is among the highest in recent years. The final optimization by computational fluid dynamic modeling and conformal coating technique was applied to evolve the PCEC air electrode from Pr 2 NiO 4+δ to Pr 1.8 Ba 0.2 NiO 4+δ -BaZr 0.1 Ce 0.7 Y 0.1 Yb 0.1 O 3-δ scaffold conformal coating. The electrolysis current was boosted from 0.445A/cm 2 to 1.46A/cm 2 at 600°C and 1.3V. A superior low degradation rate of 1mV/kh was achieved in a 5000-hour of operation. Technical effectiveness and economic feasibility: The effectiveness of this TCO conformal coating on electrolyte backbone as air electrode has been proven by long-term demonstration. Based on the highly conductive BZCYYb electrolyte and the TCO steam electrode PNO, this project rationally took advantage of the existent materials to structure a PCEC device with high TRL and low risk. The solution infiltration method used to structure the conformal coating is a standard method used by the solid oxide cell community. Very minimal adoption is needed in the current SOC fabrication process. It is a cost-effective, scalable method for manufacturing, and brings up remarkable impact on the current technical status of PCEC. Benefit to the public: The findings in the research showed the industry that the severe challenge in PCEC can be overcome in a practical way. A various energy-hydrogen ecosystem is not beyond reach. The success of this technology provides sustainable and affordable H 2 to society. It will stimulate investment from the governmental and private sectors in response to the device manufacture and deployment, and the related infrastructure construction. It will generate high-pay domestic jobs and environmental benefits to the general public in the United States.

08 HYDROGEN↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced oxygen-electrode-supported solid oxide electrochemical cells with Sr(Ti,Fe)O 3–δ -based fuel electrodes for electricity generation and hydrogen production

Sr(Ti 0.3 Fe 0.7 )O 3–δ (STF) and the associated exsolution electrodes Sr 0.95 (Ti 0.3 Fe 0.63 Ru 0.07 )O 3–δ (STFR), or Sr 0.95 (Ti 0.3 Fe 0.63 Ni 0.07 )O 3–δ (STFN) are alternatives to Ni-based cermet fuel electrodes for solid oxide electrochemical cells (SOCs). They can provide improved tolerance to redox cycling and fuel impurities, and may allow direct operation with hydrocarbon fuels. However, such perovskite-oxide-based electrodes present processing challenges for co-sintering with thin electrolytes to make fuel electrode supported SOCs. Thus, they have been mostly limited to electrolyte-supported SOCs. Here, we report the first example of the application of perovskite oxide fuel electrodes in novel oxygen electrode supported SOCs (OESCs) with thin YSZ electrolytes, and demonstrate their excellent performance. The OESCs have La 0.8 Sr 0.2 MnO 3–δ –Zr 0.92 Y 0.16 O 2–δ (LSM–YSZ) oxygen electrode-supports that are enhanced via infiltration of SrTi 0.3 Fe 0.6 Co 0.1 O 3–δ , while the fuel electrodes are either Ni-YSZ, STF, STFN, or STFR. Fuel cell power density as high as 1.12 W cm –2 is obtained at 0.7 V and 800 °C in humidified hydrogen and air with the STFR electrode, 60% higher than the same cell made with a Ni-YSZ electrode. Electrolysis current density as high as –1.72 A cm –2 is obtained at 1.3 V and 800 °C in 50% H 2 O to 50% H 2 mode; the STFR cell yields a value 72% higher than the same cell made with a Ni-YSZ electrode, and competitive with the widely used conventional Ni-YSZ-supported cells. The high performance is due in part to the low resistance of the thin YSZ electrolyte, and also to the low fuel electrode polarization resistance, which decreases with fuel electrode in the order: Ni-YSZ > STF > STFN > STFR. The high performance of the latter two electrodes is due to exsolution of catalytic metal nanoparticles; the results are discussed in terms of the microstructure and properties of each electrode material, and surface oxygen exchange resistance values are obtained over a range of conditions for STF, STFN, and STFN. Furthermore, the STF fuel electrodes also provide good stability during redox cycling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additively Manufactured Carbon Fiber-Reinforced Siliconized Silicon Carbide Composites Using Carbon Fiber-Reinforced Poly-Ether-Ether-Ketone (PEEK) as a Precursor

Herein, we report a method to additively manufacture carbon fiber-reinforced siliconized silicon carbide composites. The process involves the pyrolysis of a 3D-printed carbon fiber-reinforced poly-ether-ether-ketone (PEEK) composite to produce a porous carbon fiber-reinforced carbon matrix composite preform, which is subsequently infiltrated with molten silicon to obtain a carbon fiber-reinforced siliconized silicon carbide composite. A key aspect of the method is limiting polymer melt flow during pyrolysis of PEEK, which is achieved by thermally annealing the 3D-printed carbon fiber-reinforced PEEK preform in air at a temperature below PEEK’s melting temperature. Rheological and differential scanning calorimetry (DSC) measurements demonstrate that the thermal annealing treatment altered the melting behavior of PEEK, while NMR and FTIR measurements provided a mechanistic explanation for the structural changes responsible for the behavior. It was also found that dimensional changes during pyrolysis were anisotropic with greater shrinkage in the stacking direction of the material.

Yoon, Bola [ORNL] (ORCID:0000000260875373)↗

Accelerating Optimal Integration of Energy Efficiency Strategies with Industrialized Modular Construction: Preprint

The National Renewable Energy Laboratory's (NREL's) Industrialized Construction Innovation team first introduced the Industrialized Construction Assessment Framework to achieve affordable, net-zero energy (NZE) modular multifamily buildings in the 2020 ACEEE paper "Integrating Energy Efficiency Strategies with Industrialized Construction for our Clean Energy Future." Since then, NREL has continued to drive the ambitious plan to accelerate optimal integration of energy efficiency strategies during industrialized construction with little or no additional cost, labor, and production time. This follow-on paper introduces the Energy in Modular (EMOD) buildings method and presents NREL's research efforts over the last two years in collaboration with industry, including affordable housing partners. NREL has developed an idealized NZE modular multifamily building design that incorporates five energy efficiency strategies well suited for industrialized construction in factories: (1) envelope thermal control, (2) envelope infiltration control, (3) mechanical, electrical, and plumbing systems, (4) smart controls, and (5) solar plus storage. This paper highlights results from leveraging design for manufacturing and assembly principles, testing, and validation pilots with factory partners; demonstrating pod prototypes in test stand at NREL; and performing simulations. Overall, these research efforts address barriers to whole-building system integration, such as poor installation quality of thermal and air barriers; lack of unitized systems for space conditioning, energy recovery and ventilation, and water heating; problematic on-site installation, commissioning, and configuration of controls; and lack of cost-effective integration for grid-friendly design and emerging technologies. Conclusively, the paper delineates next steps for future work with NREL's partners toward developing a transformational pathway for our clean energy future.

affordable housing↗

Seismic Ambient Noise Analyses Reveal Changing Temperature and Water Signals to 10s of Meters Depth in the Critical Zone

The critical zone sustains terrestrial life, but we have few tools to explore it efficiently beyond the first few meters of the subsurface. Using analyses of high-frequency ambient seismic noise from densely spaced seismometers deployed in the forested Shale Hills subcatchment of the Susquehanna Shale Hills Critical Zone Observatory (SSHCZO), we show that temporal changes in seismic velocities at depths from ~1 m to tens of m can be detected. Furthermore, these changes are driven by variations at the land surface. The Moving-Window Cross-Spectral (MWCS) method was employed to measure seismic-velocity changes in coda waves at hourly resolution in 10 different frequency bands. We observed a diurnal signal, a seasonal signal, and a meteorological-event-based signal. These signals were compared to time-series measurements of precipitation, well water levels, soil moisture, soil temperature, air temperature, latent heat flux, and air pressure in the heavily instrumented catchment. Most of the velocity changes can be explained by variations in temperature that result in thermoelastic strains that propagate to depth. But some double minima in seismic velocity time-series observed after large rain events were attributed in part to the effects of water infiltration. These results show that high-frequency ambient noise data may in some locations be used to detect changes in the critical zone from ~1 to ~100 m or greater depth with hourly resolution. But interpretation of such data requires multiple environmental data sets to deconvolve the complex interrelationships among thermoelastic and hydrological effects in the subsurface critical zone.

54 ENVIRONMENTAL SCIENCES↗

Design, Fabrication and On-Sun Performance Evaluation of SiC Receiver Feature Specimens for CST Applications Using Additively Manufactured SiC Materials

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Successful development of CST systems to generate heat for industrial applications requires significant increase in temperature capability and techno-economically viability of the receiver systems. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Aerospace Research in collaboration with Heliogen Holdings Inc and Sandia National Lab, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to demonstrate SiC receiver with air exit temperatures up to 1100 oC and high thermal efficiencies. We report design, fabrication and on-sun test results of SiC components of a prototype 50kW (thermal) HOTSSTAR module. The receiver module architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around a SiC center absorber. The SiC components are fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the reliability and to minimize the risk of cracking damage of SiC test articles in thermal gradient and thermal shock environment of the application, the components were laminated with GE’s MI SiC-SiC CMC. Following extensive design and lab test analyses, selected SiC component designs are tested at Heliogen Lancaster Solar field under highly concentrated solar fluxes around 2000 suns to assess the thermal performance characteristics under realistic field conditions. We report on the test results and compare the thermal performances of different HOTSSTAR SiC absorbers. Finally, we discuss fabrication and initial assembly of a 50kW prototype test module in preparation of on-sun field tests to assess the performance of our final design.

CST, CSP, high temperature, air receiver, SiC, add↗

Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.

14 SOLAR ENERGY↗

Insight on electrolyte infiltration of lithium ion battery electrodes by means of a new three-dimensional-resolved lattice Boltzmann model

Electrolyte filling takes place between sealing and formation in Lithium Ion Battery (LIB) manufacturing process. This step is crucial as it is directly linked to LIB quality and affects the subsequent time consuming electrolyte wetting process. Although having fast, homogeneous and complete wetting is of paramount importance, this process has not been sufficiently examined and fully understood. For instance, experimentally available data is insufficient to fully capture the complex interplay upon filling between electrolyte and air inside the porous electrode. We report here for the first time a 3D-resolved Lattice Boltzmann Method (LBM) model able to simulate electrolyte filling upon applied pressure of LIB porous electrodes obtained both from experiments (micro X-ray tomography) and computations (stochastic generation, simulation of the manufacturing process using Coarse Grained Molecular Dynamics and Discrete Element Method). The model allows obtaining advanced insights about the impact of the electrode mesostructures on the speed of electrolyte impregnation and wetting, highlighting the importance of porosity, pore size distribution and pores interconnectivity on the filling dynamics. Furthermore, we identify scenarios where volumes with trapped air (dead zones) appear and evaluate the impact of those on the electrochemical behavior of the electrodes.

25 ENERGY STORAGE↗

Summertime Near-Surface Temperature Biases Over the Central United States in Convection-Permitting Simulations

Convection-Permitting Model (CPM) simulations of the Central United States climate for the summer of 2011 are studied to understand the causes of warm biases in 2-m air temperature (T 2m ) and related underestimates of precipitation including that from mesoscale convective systems (MCSs). Based on 10 CPM simulations and 9 coarser-resolution model simulations, we quantify contributions from evaporative fraction (EF) and radiation to the T 2m bias with both types of models overestimating T 2m largely because they underestimate EF. The performance of CPMs in capturing MCS characteristics (frequency, rainfall, propagation) varies. The pre-summer precipitation bias has large correlation with mean summertime T 2m bias but the relationship between summertime MCS mean rainfall bias and T 2m bias is non-monotonic. Analysis of lifting condensation level deficit and convective available potential energy suggests that models with T 2m warm biases and low EF have too dry and stable boundary layers, inhibiting the formation of clouds, precipitation and MCSs. Among the CPMs with differing model formulations (e.g., transpiration, infiltration, cloud macrophysics and microphysics), evidence suggests that altering the land-surface model is more effective than altering the atmospheric model in reducing T 2m biases. In conclusion, these results demonstrate that land-atmosphere interactions play a very important role in determining the summertime climate of the Central United States.

2-m air temperature↗

Resolving the Atomic Structure of Sequential Infiltration Synthesis Derived Inorganic Clusters

Sequential infiltration synthesis (SIS) is a route to the precision deposition of inorganic solids in analogy to atomic layer deposition but occurs within (vs upon) a soft material template. SIS has enabled exquisite nanoscale morphological complexity in various oxides through selective nucleation in block copolymers templates. However, the earliest stages of SIS growth remain unresolved, including the atomic structure of nuclei and the evolution of local coordination environments, before and after polymer template removal. We employed In K-edge extended X-ray absorption fine structure and atomic pair distribution function analysis of high-energy X-ray scattering to unravel (1) the structural evolution of InO x H y clusters inside a poly(methyl methacrylate) (PMMA) host matrix and (2) the formation of porous In 2 O 3 solids (obtained after annealing) as a function of SIS cycle number. Early SIS cycles result in InO x H y cluster growth with high aspect ratio, followed by the formation of a three-dimensional network with additional SIS cycles. That the atomic structures of the InO x H y clusters can be modeled as multinuclear clusters with bonding patterns related to those in In 2 O 3 and In(OH) 3 crystal structures suggests that SIS may be an efficient route to 3D arrays of discrete-atom-number clusters. As a result, annealing the mixed inorganic/polymer films in air removes the PMMA template and consolidates the as-grown clusters into cubic In 2 O 3 nanocrystals with structural details that also depend on SIS cycle number.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of low-cost indoor air quality monitors for PM 2.5 and PM 10 from residential sources

Advances in particle sensor design and manufacturing have enabled the development of low-cost air quality monitors (LCMs). Here, the sensors use light scattering to estimate mass concentration and thus require evaluation for aerosols of varied composition and size distribution. We tested the performance of six LCMs designed for home use and having a retail price under US$300 in October 2018. We assessed their performance by comparing their output to reference PM 2.5 and PM 10 measurements from 21 common residential sources and from infiltrated outdoor PM 2.5 . Reference data were obtained by using gravimetric measurements to adjust time-resolved output from an aerosol spectrometer with both electrical mobility and optical particle sensors. Compared by linear regression to reference measurements, LCMs had negative intercepts and slopes of 1–2 for infiltrated outdoor PM 2.5 . Semi-quantitative responses (~50–200% of actual PM 2.5 ) were obtained for varied aerosols including minerals (ultrasonic humidifier, vacuuming, test dust); combustion products (incense, mosquito coil, extinguished candles); microwave popcorn; and cooking involving frying or grilling. LCMs had low or no response to sources for which all mass was in particles smaller than 0.25 μm, including steady candle flames and cooking without frying or grilling. PM 10 data from LCMs was more variable than PM 2.5 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗