Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR QUALITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Air Quality Changes after Implementation of Mitigation Measures during a Pandemic: A Scoping Review of Literature in the United States

Traffic-related emissions continue to be a significant source of air pollution in the United States (US) and around the globe. Evidence has shown that previous policies implemented to restrict-traffic flows have affected air pollution levels. Thus, mitigation strategies associated with the COVID-19 pandemic that modified population-level mobility patterns provide a unique opportunity to study air pollution change across the US. For instance, to slow the spread of the pandemic, state and local governments started implementing various mitigation actions, including stay-at-home directives, social distancing measures, school closures, and travel restrictions. This scoping review aimed to summarize the existing evidence about how air quality changed through mitigation practices throughout the pandemic in the US. We found 66 articles that fit our inclusion criteria. Generally, the consolidated results revealed that nitrogen dioxide (NO 2 ) and carbon monoxide (CO) decreased across the country. Studies observed mixed directions and magnitudes of change for fine and coarse particulate matter (PM 2.5 , PM 10 ), ozone (O 3 ), and sulfur dioxide (SO2). Few articles tried to explain this notable heterogeneity in air quality changes by associating contextual factors, such as mobility, traffic flow, and demographic factors. However, all studies agreed that the change in air pollution was nonuniform across the US and even varied within a city.

54 ENVIRONMENTAL SCIENCES↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Modeling the impact of COVID-19 on air quality in southern California: implications for future control policies

Abstract. In response to the coronavirus disease of 2019 (COVID-19), California issued statewide stay-at-home orders, bringing about abrupt and dramatic reductions in air pollutant emissions. This crisis offers us an unprecedented opportunity to evaluate the effectiveness of emission reductions in terms of air quality. Here we use the Weather Research and Forecasting model with Chemistry (WRF-Chem) in combination with surface observations to study the impact of the COVID-19 lockdown measures on air quality in southern California. Based on activity level statistics and satellite observations, we estimate the sectoral emission changes during the lockdown. Due to the reduced emissions, the population-weighted concentrations of fine particulate matter (PM2.5) decrease by 15 % in southern California. The emission reductions contribute 68 % of the PM2.5 concentration decrease before and after the lockdown, while meteorology variations contribute the remaining 32 %. Among all chemical compositions, the PM2.5 concentration decrease due to emission reductions is dominated by nitrate and primary components. For O3 concentrations, the emission reductions cause a decrease in rural areas but an increase in urban areas; the increase can be offset by a 70 % emission reduction in anthropogenic volatile organic compounds (VOCs). These findings suggest that a strengthened control on primary PM2.5 emissions and a well-balanced control on nitrogen oxides and VOC emissions are needed to effectively and sustainably alleviate PM2.5 and O3 pollution in southern California.

54 ENVIRONMENTAL SCIENCES↗

Stakeholder analysis for designing an urban air quality data governance ecosystem in smart cities

Cities, the world over, are fuelling economic growth. At the same time, rapid urbanization is a root cause of serious environmental damage. Recent WHO global air pollution guidelines highlight air pollution as a critical environmental threat along with climate change. To address these threats, smart cities and clean air programs are on a rise. In smart cities, data and Information and Communication Technologies (ICT) are major drivers of city transformations. The 4th Industrial Revolution (4IR) technologies such as the Internet of Things (IoT), big data, artificial intelligence (AI), and cloud computing have the potential to accelerate these transformations toward urban resilience. However, the success of smart cities and clean air programs depends on cohesive multi-sector stakeholder contributions. This study conducted interdisciplinary participative stakeholder analysis to understand the data, and sectorial challenges, to outline the technological opportunities to facilitate clean air programs in Indian smart cities. The research highlights gaps due to siloed stakeholder operations, lack of data calibration, non-alignment of smart city and air quality management services, non-availability of health exposure data, and difficulty in translating scientific data into implementable actions. Stakeholders expressed potential ‘fit for the purpose’ use of IoT devices, satellites, smartphones, and mobility data augmented by AI methods in bridging these gaps. In conclusion, the analysis points toward a need to develop an easily accessible and ubiquitous urban data governance ecosystem enabling seamless cross-sector data exchanges to build trusting relationships among the stakeholders across the air quality management value chain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating air quality and health considerations into power sector decarbonization strategies

Climate change and public health are two interconnected societal challenges. Curbing fossil-based electricity generation reduces the emissions of both CO 2 and air pollutants, which brings tangible health benefits from improved air quality. The potential health benefits from decarbonizing the grid are enormous, immediate, and widespread. From renewable portfolio standards to carbon market, the health co-benefits from clean electricity policies often outweigh their policy costs. As climate action goes local, framing decarbonization around health benefits also makes it more personally relevant and economically attractive. Yet, to date, the health impacts have largely been viewed as ancillary benefits from decarbonization, rather than as a core consideration when energy strategies are formed, assessed and implemented. When strategic choices are made about retiring old infrastructure and building new ones, bringing public health to the center of the discussion can generate greater health benefits with more equitable distribution. Here we identify concrete ways to incorporate air quality and health considerations into power sector decarbonization strategies. We draw insights mainly from empirical and modeling evidence for the United States. These insights are generally applicable and could guide health-oriented decarbonization efforts in other countries as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Interconnection and Renewables Deployment Related Air Quality and Human Health Benefits in Southeast Asia

The Association of Southeast Asian Nations (ASEAN) has increasingly focused on multilateral electricity trade, improved grid resiliency and modernization. These opportunities in the power sector have been studied through the ASEAN Interconnection Masterplan Studies, the most recent of which is the ASEAN Interconnection Masterplan Study III (AIMS III). AIMS III assessed four different scenarios of power system in the ASEAN countries that include a base scenario and three additional scenarios (called optimum RE, ASEAN RE, and High RE) considering different levels of deployment of renewable energy (RE) and cross-border generation and trade of electricity for three years (2025, 2030, 2040). In this work, we quantify the potential air quality and public health co-benefits of AIMS III scenarios. For a rapidly expanding, energy hungry region like SE Asia generation is power generation is expected to increase significantly. The AIMS III scenarios' capacity expansion modeling suggest that: 1) Generation nearly doubles from 2025 to 2040 in all four AIMS III scenarios; 2) Most of the increased generation is met by coal in all four AIMS III scenarios; 3) While renewables generation increases in all four AIMS III scenarios, the fraction of total generation (its share) generally decreases because of the much greater increase in non-renewable sources, mostly coal. Only in the High RE Target scenario do renewables represent a higher share in 2040 than in 2025, though even here it is at the expense of natural gas rather than coal; 4) As a result, emissions of gaseous and aerosol pollutants increase significantly in all scenarios. Because emissions increase in 2040 compared to 2025 for all four AIMS III scenarios, so do PM2.5 concentrations. Even for the High RE Target scenario (the scenario with highest share of renewable energy), compared to the Base scenario in 2025, in 2040 PM2.5 concentrations are higher. Compared to the Base scenario in the same years, the Optimum RE and ASEAN RE Target scenarios do not differ very much from the Base in terms of PM2.5 concentration. The High RE Target scenario, on the other hand, yields noticeably lower PM2.5 concentration. For example, in 2040 the population-weighted decrease in annual average PM2.5 concentration in the High RE Target scenario relative to the Base scenario is 0.5 ug m-3. Compared to the Base scenario in 2040, each of the alternative AIMS III scenarios is estimated to result in net reductions in power-sector air quality-related excess mortality in the ASEAN region. Yet there are a few countries for which the Optimum RE and ASEAN RE Target result in increases in PM2.5-related excess mortality (Thailand and Vietnam for the ASEAN RE Target scenario and Thailand for the Optimum RE scenario). However, for the High RE Target scenario, all countries benefit and find reductions in excess mortality resulting from the power sector scenarios modeled in AIMS III with regionwide mortality decreasing by 16,000 compared to the Base scenario in 2040. In summary, our analysis finds that changing power generation emissions is a crucial lever for improving public health in ASEAN member countries and provides a pathway for policymakers to make decision backed by a realistic power sector expansion and air quality analyses.

air quality↗

A Succession of Cloud, Precipitation, Aerosol and Air Quality Field Experiments in the Coastal Urban Environment

The interactions and feedbacks among clouds, aerosols, pollutants, and the thermodynamic and kinematic environment remains an area of active research with important implications for our understanding of climate, weather and air quality. These linkages are further complicated in coastal and urban environments where local circulations and anthropogenic influences impact each of these components and their interactions. Within this context, fundamental questions regarding the lifecycle of convective clouds, aerosols and pollutants have brought together a diverse, integrated, and interagency collaboration of scientists to collect and analyze measurements, in the Houston, Texas, area, from the summer of 2021 through the summer of 2022, with subsequent modeling studies to address these important research objectives. Herein, the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Facility and Atmospheric System Research (ASR) Program, the National Science Foundation’s (NSF) Physical and Dynamic Meteorology Program, the National Aeronautic and Space Administration’s (NASA’s) Tropospheric Composition Research and Health and Air Quality Applied Sciences Programs and the Texas Commission on Environmental Quality (TCEQ) are collaborating on a joint set of field campaigns to study the interactions of cloud, aerosol, and pollutants within the coastal, urban environment. In the Houston area, onshore flow from the Gulf of Mexico and the associated sea breeze circulation generates numerous isolated convective cells, particularly in the summer months, that interact with a variety of urban and industrial emissions.

54 ENVIRONMENTAL SCIENCES↗

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

EBSD seed LDRD project: Does Corona Virus – 2019 (COVID-19) and Seasonal Flu have similar meteorology and air quality controls driving their spread?

Seasonal influenza and Influenza like Illnesses (ILI) pose a serious public health risk and in turn affect the economy. Various factors affect ILI cases and mortality, including the pathogen and its interaction with the host, as well as environmental and socioeconomic factors such as meteorology, household structure, air pollution, urbanization, and population. Despite the growing number of studies on influenza and ILI, challenges remain in forecasting the timing of seasonal onset, outbreak patterns, and key factors affecting transmission. In particular, the impacts of meteorology and air quality on ILI have been challenging to understand, with linear regression studies focused on different geographic regions producing contradictory results. For example, influenza seasonality has been associated with cold-dry conditions in temperate mid-latitudes, but with humid-rainy conditions in tropical climates. These apparently contradictory results imply that the relationships between influenza cases and atmospheric variables may be too complex to be captured by linear regression models. In this seed project, we analyze meteorology and air quality variables from numerical models to determine which atmospheric variables are most helpful in predicting weekly changes in recorded flu cases. In contrast to most previous studies that relied on linear regression analysis to predict the timing of the flu onset or peak, we employ a robust machine learning algorithm to evaluate the contribution of atmospheric variables to weekly changes in recorded ILI cases. These results may also be relevant to the spread of other respiratory illnesses such as Corona Virus Disease – 2019 (COVID-19).

60 APPLIED LIFE SCIENCES↗

Using Satellite‐Derived Fire Arrival Times for Coupled Wildfire‐Air Quality Simulations at Regional Scales of the 2020 California Wildfire Season

Abstract Wildfire frequency has increased in the Western US over recent decades, driven by climate change and a legacy of forest management practices. Consequently, human structures, health, and life are increasingly at risk due to wildfires. Furthermore, wildfire smoke presents a growing hazard for regional and national air quality. In response, many scientific tools have been developed to study and forecast wildfire behavior, or test interventions that may mitigate risk. In this study, we present a retrospective analysis of 1 month of the 2020 Northern California wildfire season, when many wildfires with varying environments and behavior impacted regional air quality. We simulated this period using a coupled numerical weather prediction model with online atmospheric chemistry, and compare two approaches to representing smoke emissions: an online fire spread model driven by remotely sensed fire arrival times and a biomass burning emissions inventory. First, we quantify the differences in smoke emissions and timing of fire activity, and characterize the subsequent impact on estimates of smoke emissions. Next, we compare the simulated smoke to surface observations and remotely sensed smoke; we find that despite differences in the simulated smoke surface concentrations, the two models achieve similar levels of accuracy. We present a detailed comparison between the performance and relative strengths of both approaches, and discuss potential refinements that could further improve future simulations of wildfire smoke. Finally, we characterize the interactions between smoke and meteorology during this event, and discuss the implications that increases in regional smoke may have on future meteorological conditions.

54 ENVIRONMENTAL SCIENCES↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

30 DIRECT ENERGY CONVERSION↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗