Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electrochemical Flow Reactor Design Allows Tunable Mass Transport Conditions for Operando Surface Enhanced Infrared Absorption Spectroscopy

Abstract In situ attenuated total reflection surface enhanced infrared absorption spectroscopy (ATR‐SEIRAS) is often used to investigate the near‐surface electrocatalytic reaction environment. However, there is a gap in directly correlating the near‐surface reaction environment with electrocatalytic reaction rates. To that end, we designed an electrochemical flow reactor for operando electrochemical ATR‐SEIRAS and demonstrate its capability with the CO 2 reduction reaction (CO 2 RR). Roughened gold catalyst thin films are prepared on ATR silicon crystals as a model system to probe local species under CO 2 RR conditions in 0.1 M KHCO 3 . We measured changes in the interfacial CO 2 concentration as a function of applied potential and electrolyte flow rate in operando , allowing us to correlate the changes in reaction rates with the observed CO 2 concentration. Including the choice of the catalyst and electrolyte, coupling hydrodynamic control with ATR‐SEIRAS in this platform enables investigations of how the local microenvironment affects the activity and selectivity of electrochemical reactions.

Avilés Acosta, Jaime E.↗

Simulated sulfur K-edge X-ray absorption spectroscopy database of lithium thiophosphate solid electrolytes

X-ray absorption spectroscopy (XAS) is a premier technique for materials characterization, providing key information about the local chemical environment of the absorber atom. In this work, we develop a database of sulfur K-edge XAS spectra of crystalline and amorphous lithium thiophosphate materials based on the atomic structures reported in Chem. Mater., 34, 6702 (2022). The XAS database is based on simulations using the excited electron and core-hole pseudopotential approach implemented in the Vienna Ab initio Simulation Package. Our database contains 2681 S K-edge XAS spectra for 66 crystalline and glassy structure models, making it the largest collection of first-principles computational XAS spectra for glass/ceramic lithium thiophosphates to date. This database can be used to correlate S spectral features with distinct S species based on their local coordination and short-range ordering in sulfide-based solid electrolytes. The data is openly distributed via the Materials Cloud, allowing researchers to access it for free and use it for further analysis, such as spectral fingerprinting, matching with experiments, and developing machine learning models.

36 MATERIALS SCIENCE↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Hyperfine structure and isotope shifts of xenon measured for near-infrared transitions with Doppler-free saturated absorption spectroscopy

Hyperfine structure and isotope shifts of Xe were investigated with Doppler-free saturated absorption spectroscopy for all transitions in the 820-841 nm spectral interval. The Xe samples were commercial gases of natural isotopic abundances. The measurements were performed by employing a widely tunable narrow line Ti:sapphire laser. The hyperfine structures for 129 Xe and 131 Xe were well resolved. For the transitions with the wavelengths in vacuum near 820.860 nm and 841.150 nm also isotope shifts of the even isotopes were clearly observed. The modeling of the shapes of the observed absorption lines qualitatively reproduces experimental spectral profiles. The measured absorption peaks of the hyperfine structure and isotope shifts of Xe isotopes present characteristic spectral fingerprints for their identification. Eventually, quantitative spectral analysis will provide isotopic abundances of natural, as well as radioactive Xe gas samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-shot X-ray absorption spectroscopy at X-ray free electron lasers

X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method for studying electronic and structural properties of matter. At first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of X-ray Free Electron Lasers (XFEL) sources seem to require accumulation over many shots to achieve high data quality. To date the best approach to implementing XAS at XFEL facilities has been using monochromators to scan the photon energy across the desired spectral range. While this is possible for easily reproducible samples such as liquids, it is incompatible with many important systems. Here, we demonstrate collection of single-shot XAS spectra over 10s of eV using an XFEL source, with error bars of only a few percent. We additionally show how to extend this technique over wider spectral ranges towards Extended X-ray Absorption Fine Structure measurements, by concatenating a few tens of single-shot measurements. Our results pave the way for future XAS studies at XFELs, in particular those in the femtosecond regime. This advance is envisioned to be especially important for many transient processes that can only be initiated at lower repetition rates, for difficult to reproduce excitation conditions, or for rare samples, such as those encountered in high-energy density physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of lattice excitations on transient near-edge x-ray absorption spectroscopy

Here, time-dependent and constituent-specific spectral changes in soft near-edge x-ray absorption spectroscopy (XAS) of an [Fe/MgO] 8 metal/insulator heterostructure after laser excitation are analyzed at the O K-edge with picosecond time resolution. The oxygen absorption edge of the insulator features a uniform intensity decrease of the fine structure at elevated phononic temperatures, which can be quantified by a simple simulation and fitting procedure presented here. Combining XAS with ultrafast electron diffraction measurements and ab initio calculations demonstrates that the transient intensity changes in XAS can be assigned to a transient lattice temperature. Thus, the sensitivity of transient near-edge XAS to phonons is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Antimony stable isotope fractionation during adsorption onto birnessite: A molecular perspective from X-ray absorption spectroscopy and density functional theory

Sorption of antimony (Sb) onto birnessite significantly influences the fate of Sb in oceanic and terrestrial environments and fractionates Sb isotopes. Nevertheless, little is known about Sb isotopic fractionation during its adsorption on birnessite. Here, in this study, we show the value of Δ 123 Sb adsorbed-aqueous increases from −0.398 to −0.332 ‰ in 1 h and then decreases and stabilizes at −0.384 ‰ in 72 h. The enrichment of the light Sb isotope is predominantly due to the distortion of the octahedral symmetry. X-ray absorption spectroscopy results indicate Sb first forms a double-corner-sharing complex on birnessite and then transforms to a double-edge-sharing complex during adsorption. The optimized bond distances for double-corner-sharing (3.37 Å) and double-edge-sharing (2.90 Å) complexes calculated using density functional theory (DFT) fits well with the structure (3.41 and 3.00 Å) revealed by X-ray absorption spectroscopy, respectively. The fractionation derived from reduced partition function ratios calculated using DFT aligns well with the experimental results. Therefore, the variation in Sb isotopic fractionation during adsorption is attributed to the evolving structure of Sb complexes on birnessite. Our results demonstrate the isotopic fractionation of Sb during adsorption on birnessite and provide a molecular-scale understanding of Sb behavior, contributing to the correct reconstruction of the Sb isotope composition of ancient seawater using ferromanganese crusts and nodules, and efforts to trace Sb migration in epigenetic mining environments.

Adsorption↗

Uranium Dust Cloud Combustion: Burning Characteristics and Absorption Spectroscopy Measurements

This study characterized uranium metal dust cloud combustion using absorption spectroscopy, imaging, and broadband emission measurements. Other metals were similarly combusted to establish correlations between results from this study and those found in the literature. It was determined that the burn temperature of uranium was limited to the volatilization temperature of uranium dioxide. Combustion behavior was similar to that of other refractory metals in terms of burn time and the observation of exploding particle behavior.

42 ENGINEERING↗

Feed-forward spectral calibration methodology for line-scanned tunable laser absorption spectroscopy

A generalized feed-forward method for accurate tunable laser absorption spectroscopy includes generating a laser beam. The generated laser beam is directed down a reference path and a test/sample path. One or more parameters are extracted from the reference path. The one or more parameters, extracted from the reference path, are used as feed-forward, to adjust spectral analysis of the test/sample path to detect a composition and/or concentration of an analyte gas within the test/sample path. The extraction of the one or more parameters from the reference path and the spectral analysis of the test/sample path are performed substantially concurrently.

Green, William↗

Beyond the electric-dipole approximation in simulations of x-ray absorption spectroscopy: Lessons from relativistic theory

Herein we present three schemes to go beyond the electric-dipole approximation in x-ray absorption spectroscopy calculations within a four-component relativistic framework. The first is based on the full semi-classical light–matter interaction operator and the two others on a truncated interaction within the Coulomb gauge (velocity representation) and multipolar gauge (length representation). We generalize the derivation of the multipolar gauge to an arbitrary expansion point and show that the potentials corresponding to different expansion points are related by a gauge transformation, provided that the expansion is not truncated. This suggests that the observed gauge-origin dependence in the multipolar gauge is more than just a finite-basis set effect. The simplicity of the relativistic formalism enables arbitrary-order implementations of the truncated interactions, with and without rotational averaging, allowing us to test their convergence behavior numerically by comparison to the full formulation. We confirm the observation that the oscillator strength of the electric-dipole allowed ligand K -edge transition of TiCl 4 , when calculated to the second order in the wave vector, becomes negative but also show that inclusion of higher-order contributions allows convergence to the result obtained using the full light–matter interaction. However, at higher energies, the slow convergence of such expansions becomes dramatic and renders such approaches at best impractical. When going beyond the electric-dipole approximation, we therefore recommend the use of the full light–matter interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗

X-ray absorption spectroscopy study of Mn reference compounds for Mn speciation in terrestrial surface environments

Abstract X-ray absorption spectroscopy (XAS) offers great potential to identify and quantify Mn species in surface environments by means of linear combination fit (LCF), fingerprint, and shell-fit analyses of bulk Mn XAS spectra. However, these approaches are complicated by the lack of a comprehensive and accessible spectrum library. Additionally, molecular-level information on Mn coordination in some potentially important Mn species occurring in soils and sediments is missing. Therefore, we investigated a suite of 32 natural and synthetic Mn reference compounds, including Mn oxide, oxyhydroxide, carbonate, phosphate, and silicate minerals, as well as organic and adsorbed Mn species, by Mn K-edge X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS) spectroscopy. The ability of XAS to infer the average oxidation state (AOS) of Mn was assessed by comparing XANES-derived AOS with the AOS obtained from redox titrations. All reference compounds were studied for their local (<5 Å) Mn coordination environment using EXAFS shell-fit analysis. Statistical analyses were employed to clarify how well and to what extent individual Mn species (groups) can be distinguished by XAS based on spectral uniqueness. Our results show that LCF analysis of normalized XANES spectra can reliably quantify the Mn AOS within ~0.1 v.u. in the range +2 to +4. These spectra are diagnostic for most Mn species investigated, but unsuitable to identify and quantify members of the manganate and Mn(III)-oxyhydroxide groups. First-derivative XANES fingerprinting allows the unique identification of pyrolusite, ramsdellite, and potentially lithiophorite within the manganate group. However, XANES spectra of individual Mn compounds can vary significantly depending on chemical composition and/or crystallinity, which limits the accuracy of XANES-based speciation analyses. In contrast, EXAFS spectra provide a much better discriminatory power to identify and quantify Mn species. Principal component and cluster analyses of k2-weighted EXAFS spectra of Mn reference compounds implied that EXAFS LCF analysis of environmental samples can identify and quantify at least the following primary Mn species groups: (1) Phyllo- and tectomanganates with large tunnel sizes (2 × 2 and larger; hollandite sensu stricto, romanèchite, todorokite); (2) tectomanganates with small tunnel sizes (2 × 2 and smaller; cryptomelane, pyrolusite, ramsdellite); (3) Mn(III)-dominated species (nesosilicates, oxyhydroxides, organic compounds, spinels); (4) Mn(II) species (carbonate, phosphate, and phyllosilicate minerals, adsorbed and organic species); and (5) manganosite. All Mn compounds, except for members of the manganate group (excluding pyrolusite) and adsorbed Mn(II) species, exhibit unique EXAFS spectra that would allow their identification and quantification in mixtures. Therefore, our results highlight the potential of Mn K-edge EXAFS spectroscopy to assess bulk Mn speciation in soils and sediments. A complete XAS-based speciation analysis of bulk Mn in environmental samples should preferably include the determination of Mn valences following the “Combo” method of Manceau et al. (2012), EXAFS LCF analyses based on principal component and target transformation results, as well as EXAFS shell-fit analyses for the validation of LCF results. For this purpose, all 32 XAS reference spectra are provided in the Online Materials1 for further use by the scientific community.

Geochemistry & Geophysics↗

Reduction and Agglomeration of Supported Metal Clusters Induced by High-Flux X-ray Absorption Spectroscopy Measurements

Supported metal clusters are widely used in catalysis for many important reactions. To understand the catalytic properties, in situ/operando characterization techniques, such as X-ray absorption spectroscopy (XAS), provide essential details of the size, shape, and chemical composition of the cluster and the nature of the active sites. New-generation synchrotrons combined with focusing beamlines provide high-flux-density X-rays for improved detection sensitivity as well as higher time and spatial resolution. Understanding the effects of a high-flux-density X-ray beam on the catalyst during the actual measurement, whether XAS or another synchrotron-based technique, is crucial. This is especially important for in situ and operando studies where both the high flux density and reaction conditions can affect the catalyst structure. In this work, we investigated the effect of the flux density on rhodium clusters supported on Al 2 O 3 at two different beamlines: National Synchrotron Light Source II beamline 08-ID and Stanford Synchrotron Radiation Light Source (SSRL) beamline 4-1. We show that the higher flux density at beamline 08-ID causes the reduction of the highly dispersed RhO x /Al 2 O 3 catalyst, even at room temperature. Additionally, exposure to the higher flux density X-rays at beamline 08-ID during in situ reduction results in significant agglomeration of the Rh clusters. The final size of the Rh nanoparticles reduced at 310 °C is equivalent to that of particles formed after the reduction at 600–650 °C in the absence of the beam. Significant beam-induced reduction and agglomeration is also shown for Ni supported on beta zeolite during in situ reduction at an intermediate-flux-density beamline 9-3 at SSRL, indicating that beam-induced changes in heterogeneous catalysts could be common at intermediate- and high-flux-density beamlines. We provide precautions and recommendations for detecting and minimizing beam damage during in situ/operando XAS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural modeling of high-entropy oxides battery anodes using x-ray absorption spectroscopy

High-entropy oxides (HEOs) are single phase solid solutions where five or more metals share the same sublattice, giving rise to unexpected features in various fields of applications. Recently, HEOs have emerged as an alternative conversion electrode anode material for next-generation Li-ion batteries, where the combination of several different elements in a single solid solution can synergistically act to overcome some of its main drawbacks, improving performance. Due to their chemical complexity, x-ray absorption spectroscopy (XAS) emerges as an appropriate technique to study the electronic (x-ray absorption near edge structure, XANES) and local structure (extended x-ray absorption fine structure, EXAFS) of these compounds as a function of cycling. This work aims to highlight the capabilities of XAS as an element-specific probe to understand a material’s structure at the atomistic level through EXAFS modeling of (MgFeCoNiCuZn)O high-entropy system and how to extract valuable information about the bond distance, number of near neighbors, and local disorder, which are crucial to a full understanding of the electrochemical reaction mechanisms of such battery electrodes.

25 ENERGY STORAGE↗

Advancing AI-Driven Analysis in X-ray Absorption Spectroscopy: Spectral Domain Mapping and Universal Models

In recent years, rapid progress has been made in developing artificial intelligence (AI) and machine learning (ML) methods for X-ray absorption spectroscopy (XAS) analysis. Compared to traditional XAS analysis methods, AI/ML approaches offer dramatic improvements in efficiency and help eliminate human bias. To advance this field, we advocate an AI-driven XAS analysis pipeline that features several interconnected key building blocks: benchmarks, workflows, databases, and AI/ML models. Specifically, we present two case studies for XAS ML. In the first study, we demonstrate the importance of reconciling the discrepancies between simulation and experiment using spectral domain mapping (SDM). Our ML model, which is trained solely on simulated spectra, predicts an incorrect oxidation state trend for Ti atoms in a combinatorial zinc titanate film. After transforming the experimental spectra into a simulation-like representation using SDM, the same model successfully recovers the correct oxidation state trend. In the second study, we explore the development of universal XAS ML models that are trained on the entire periodic table, which enables them to leverage common trends across elements. Looking ahead, we envision that an AI-driven pipeline can unlock the potential of real-time XAS analysis to accelerate scientific discovery.

36 MATERIALS SCIENCE↗

Total absorption spectroscopy measurement on neutron-rich 74,75 Cu isotopes

This paper reports on the first β-decay study of 74,75 Cu isotopes using the technique of total absorption spectroscopy (TAS). The experiment was performed at the National Superconducting Cyclotron Laboratory at Michigan State University using the Summing NaI(Tl) (SuN) detector. The Cu isotopes are good candidates to probe the single-particle structure in the region because they have one proton outside the Z = 28 shell. Comparing the β-decay intensity distributions in the daughter Zn isotopes to the theoretical predictions provides a stringent test of the calculations. The nuclei in this region are also identified as playing an important role in the astrophysical r-process. Furthermore, the measured β-decay intensity distributions provide essential nuclear physics inputs required to better understand heavy element nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Addition of transient kinetics capabilities to an infrared reflection absorption spectroscopy system through synchronized gas pulsing and data acquisition

Surface science methodologies for understanding thermodynamic aspects of surface processes are at an advanced level. However, instrumentation and approaches for extracting kinetic parameters from elementary steps are far less accessible. In this work, we present an approach combining the use of a fast gas pulsing valve synchronized with data acquisition to enable surface transient kinetics studies using infrared reflection absorption spectroscopy. This methodology applies to the study of reversible processes and borrows concepts and ideas from molecular beam scattering and temporal analysis of products. Here, a temporal resolution of ~67 ms is achieved, and this is illustrated through the study of CO adsorption and desorption on a Pd(111) crystal in the presence and absence of background O 2 . The same approach can be extended to other surface spectroscopies, such as X-ray photoelectron spectroscopy, to obtain spectra with high temporal resolution and signal-to-noise ratio and enable future multimodal surface transient kinetic studies aiming at elucidating reaction mechanisms.

36 MATERIALS SCIENCE↗

Measurement of coherent vibrational dynamics with X-ray Transient Absorption Spectroscopy simultaneously at the Carbon K- and Chlorine L 2,3 - edges

X-ray Transient Absorption Spectroscopy (XTAS) is a powerful probe for ultrafast molecular dynamics. The evolution of XTAS signal is controlled by the shapes of potential energy surfaces of the associated core-excited states, which are difficult to directly measure. Here, we study the vibrational dynamics of Raman activated CCl 4 with XTAS targeting the C 1s and Cl 2p electrons. The totally symmetric stretching mode leads to concerted elongation or contraction in bond lengths, which in turn induce an experimentally measurable red or blue shift in the X-ray absorption energies associated with inner-shell electron excitations to the valence antibonding levels. The ratios between slopes of different core-excited potential energy surfaces (CEPESs) thereby extracted agree very well with Restricted Open-Shell Kohn-Sham calculations. The other, asymmetric, modes do not measurably contribute to the XTAS signal. The results highlight the ability of XTAS to reveal coherent nuclear dynamics involving < 0.01 Å atomic displacements and also provide direct measurement of forces on CEPESs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗